HPH Series J-Hook Installation Instructions

Similar documents
Beam and Purlin Clamps Beam Clamps

MPA-9000 Universal Ceiling Projector Mount Kit

SWAY BRACE PIPE ATTACHMENT FIG. 010

CSS Central Mount System

Tel: +44 (0)

mila-wall (Series100) General Operating Instructions page 1 of 15

Hang-TITE Rod Hanger Screws

Kai Installation Instructions

Installation Instructions

**MOUNTING YOUR MONITOR

Installation Guide. Mounting Kit for Mounting Philips Avalon CTS Cordless Fetal Transducer System on Wall, 2'' Post, Rail, or Slide-on Mounting Plate

Elco Construction Products 1301 Kerr Drive Decorah, IA fax:

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

ASSEMBLY AND ADJUSTMENT

Installation Instruction

INSTALLATION INSTRUCTIONS DODGE RAM 2 & 4WD 1500 PART # P5058

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

SM-RAZOR-ART2-L / SM-RAZOR-ART2-XL

Instructions and Parts List DR-12N Martin House

Track Rack. * Track Racks are not lockable

STEEL C-CLAMP WITH LOCKNUT

RBP-1215B-RX DODGE RAM QUAD CAB RX3

Copper Tubing Hangers Clevis Hangers. Copper Tubing Hangers

Jenny Legs Assembly Instructions

EDGE2 DUAL MONITOR ARM

INSTALLATION INSTRUCTIONS GRILLE GUARD RAM 1500 PART # 5058/5058-2

MAG-CONV Basic, 48, 48R & Midline Front Mount

Installation and Assembly: Ceiling mount for LCD screens up to 29"

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

BEST PRACTICE GUIDE. Socket Bases. Working with Concrete Slabs

DEPTH-KIT-785 Seat Depth Extension

Fortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards.

TITAN2-EDGE Public Access Computer Station Dual Track

Independent Containment System (ICS)

TOOLS REQUIRED: HARDWARE INCLUDED: 13MM FLAT WRENCH FOR LEVELING THE STRUCTURE RATCHET WITH 5MM HEX BIT FOR CORNER SCREWS ON TOP TRAVERSE BEAMS

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

High Performance CADDY CAT HP

KOLO SHELTER Installation Instructions Parts List

Page 1. SureMotion Quick-Start Guide: LARSACC_QS 1st Edition - Revision A 03/15/16. Standard Steel Bolt/Screw Torque Specifications

WK9 WORKTOP KIT Assembly Guide

Leveling Feet, Base Plates and Casters

Fortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards.

INSTALLATION TORSION SPRING FRONT OR REAR MOUNT LOW HEADROOM. 1 Cutting Vertical Track. 2 Fully Adjustable Jamb Brackets

WEIGHT ADJUSTABLE ESPREE. Model 2ESP-WA-C48- Model 2ESP-WA-C60- 2ESP-WA Rev B 8/17 ASSEMBLY AND OPERATION

Flooring Nails 6-D Flooring Nails $3.40 / 1# 6-D Flooring Nails $14.50 / 5# 8-D Flooring Nails $3.40 / 1# 8-D Flooring Nails $14.

Bumper Sign INSTALLATION INSTRUCTIONS

MM340 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

RH-412 STEEL DOORS INSTALLATION INSTRUCTIONS

SINGLE TRACK BYPASS (patent pending) barn door hardware

Installation Instructions for Bike Fixtation Public Work Stand and Floor Pump Manual RevH

INSTALLATION INSTRUCTIONS RH 412 STEEL DOORS

Equilibrium. Conference Table. Installation Instruction. Revision B 11/07/16

INSTRUCTIONS TS93 GSR PT RIGHT HAND ACTIVE LEFT HAND INACTIVE RIGHT HAND INACTIVE LEFT HAND ACTIVE

Calf-Tel Pen System Assembly Instructions

Fortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards.

INSTALLATION INSTRUCTIONS

Hangers. Vertical Flange. Hangers BF3 For S" Hooks, 100 Bolting Straps and Wrap Wire

Interactive Monitor Arm

Installation and Assembly - Desktop Swivel Mount For 32" - 55" Flat Panel Display

PFW 6875 Installation Guide Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d Installation, Installatie gids

It is highly recommended that you use a thread lock compound such as Loctite brand on all threads to keep them from vibrating loose.

MM540 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Installation Instructions

USSC LLC 4 ONE LLC FIELD MODIFICATION INSTRUCTIONS

AX1001. Smith/Functional training Combo-free weight ASSEMBLY INSTRUCTIONS

Installation Manual ZGuard Mounting Options

TRAILMATE METEOR ASSEMBLY MANUAL

STEP 1 STEP 2 LEVELER KIT OPTION MOBILE CASTER KIT OPTION

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

Rayport G Eco Dealer Kit

INSTALLATION INSTRUCTIONS Product No. MULTI-FIT PICK-UP

Installation and Assembly - Articulating Swivel Double-Arm for 42" - 71" Plasma Screens

Mounting a BalanceBox 400 to a brick wall

Fortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards.

Fortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards.

WARNING. Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.

Workbench Instructions for Assembly

Bike Locker Model DBL1 & DBL2

Installation Instructions - Model V4JSD 1

Installation and Assembly: Wallmount for CPA100 and Whiteboard

Setup. The Faraday Cage is available in two types of configurations. Cage for mounting to a full perimeter enclosure on series tables.

/A INSTALLATION MANUAL

PH03 Comfort XL Front Assembly Replacement Instructions

ATLANTIS RAIL Contact Information

INSTALLATION INSTRUCTIONS

Installation Instructions for: Saris Cycle Aid. Saris Cycle Air. Saris Cycle Air HD

NX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

Instruction Sheet For: SCM-2

SB-WM-ART2-L-BL SB-WM-ART2-XL-BL

INSTALLATION GUIDE. Model:B60 RECESSED IN WALL MOUNT

Showpiece Cabinet Integrated Stand For 32" - 52" LCD HDTV

MITCHELL WREATH RINGS NO-HAMMER ASSEMBLY INSTRUCTIONS

Installation Guide Philips MP40/50/60/70 Installation Kit for Penlon Anesthesia Machine

LCD LIFT Flat Panel Display System Installation Manual. Table of Contents

Attachment Illustrated Parts List

HIGH RISE Portable Restroom Assembly Instructions

INSTALLATION GUIDE Ceiling TV Mount MHP-52

IN 578. Tools Required. Torque Specification: 10mm Socket 7/16 Socket 1/2 Socket 1/2 Wrench 7/16 Wrench 1/8 Allen Wrench.

TM12 ASSEMBLY INSTRUCTIONS

Transcription:

HPH Series J- Installation Instructions 1

Mounting to a vertical surface: HPH16, HPH32, HPH48 and HPH64 Use a nail*, bolt* or screw* with a minimum head diameter of 0.329 (1-A) and an appropriate length for the substrate (1-B) to fasten the HPH J- (2) to the vertical surface (3). Insert the cables and close the latch as shown in 3. The latch must be in the closed position as shown in 4 to secure the cables and complete the installation. 1 2 3 4 Part UL Load Rating HPH16 1" 20 88.96 1 Standard HPH J-, size 16 HPH32 2 2 & 4 17 75.62 2 Standard HPH J-, size 32 HPH48 3 20 88.96 3 Standard HPH J-, size 48 HPH64 4 17 75.62 4 Standard HPH J-, size 64 2

Mounting to a rod or ceiling wire with a Multi-Function Clip-Batwing: HPH16W, HPH32W, HPH48W and HPH64W HPHXXW J-s (1) are pre-assembled to Multi-Function Clip-Batwings at the factory using a fastener such as a rivet or a zinc plated ¼-20 x 3/8 pan head Phillips machine bolt and a grade A ¼-20 hex Nylon locknut (2). A plain HPH J- may be assembled to a UL listed batwing clip in the field with the use of a similar fastener. Depress the batwing between your fingers ( 3). Attach the HPHXXW to 12 gauge ceiling wire or 1/4" threaded rod (4 and 6). Insert the cables and close the latch (5 and 7). The latch must be in the closed position as shown in 8 to secure the cables and complete the installation. 1 2 3 4 5 3

6 7 8 Part UL Load Rating HPH16W 1" 20 88.96 1 Batwing HPH J-, size 16 HPH32W 2 1 20 88.96 2 Batwing HPH J-, size 32 HPH48W 3 & 20 88.96 3 Batwing HPH J-, size 48 8 HPH64W 4 20 88.96 4 Batwing HPH J-, size 64 4

Mounting to a rod or a horizontal surface with an Angle Clip 90 : HPH16AC, HPH16AC6 HPH32AC, HPH32AC6, HPH48AC, HPH48AC6, HPH64AC & HPH64AC6 HPHXXAC and HPHXXAC6 J-s (1 and 2) are pre-assembled to Angle Clips 90 at the factory using a fastener such as a rivet or a zinc plated ¼-20 x 3/8 pan head Phillips machine bolt and a grade A ¼-20 hex Nylon locknut (3). A plain HPH J- may be assembled to a Platinum Tools Angle Clip 90 in the field using a similar fastener. Fasten the HPHXXAC or HPHXXAC6 to 1/4" or 3/8 threaded rod using two standard hex nuts (4). Thread a single nut up to the desired location of the threaded rod. Guide the HPHXXAC or HPHXXAC6 onto the threaded rod. Thread a second nut onto the threaded rod and tighten to the first nut, thereby sandwiching the Angle Clip 90 between the two nuts (5). An HPHXXAC or an HPHXXAC6 may be fastened directly to the underside of a horizontal surface using an appropriate fastener* (6). Use a fastener with an appropriate head diameter (7-A) and an appropriate length for the substrate (7-B). Place the cables in the hook and close the latch as shown in 5 and 6. The latch must be in the closed position as shown in 8 and 9 to secure the cables and complete the installation. 1 2 3 4 5 5

6 7 8 9 Part UL Load Rating Angle Clip Hole HPH16AC 1" 1 20 88.96 1/4" 1 90 Angle HPH J-, size 16 HPH16AC6 1 2 20 88.96 3/8 1 90 Angle/6 HPH J-, size 16 HPH32AC 2 1 20 88.96 1/4" 2 90 Angle HPH J-, size 32 HPH32AC6 2 2 20 88.96 3/8 2 90 Angle/6 HPH J-, size 32 HPH48AC 3 1 20 88.96 1/4" 3 90 Angle HPH J-, size 48 HPH48AC6 3 2 20 88.96 3/8 3 90 Angle/6 HPH J-, size 48 HPH64AC 4 1 20 88.96 1/4" 4 90 Angle HPH J-, size 64 HPH64AC6 4 2 20 88.96 3/8 4 90 Angle/6 HPH J-, size 64 6

Mounting to a horizontal surface with an Angle Clip 90 w/powder Actuated Nail (PAN): HPH16ACPA, HPH32ACPA, HPH48ACPA and HPH64ACPA Use a powder actuated tool* to install the 1-5/16 pin into an appropriate material such as concrete as shown in 3 & 4. 1 2 3 4 Part Load Rating HPH16ACPA 1" 20 88.96 1 90 Angle w/pan HPH J-, size 16 HPH32ACPA 2 1 20 88.96 2 90 Angle w/pan HPH J-, size 32 HPH48ACPA 3 & 20 88.96 3 90 Angle w/pan HPH J-, size 48 HPH64ACPA 4 2 20 88.96 4 90 Angle w/pan HPH J-, size 64 7

Mounting to a beam with an HOK24 or HOK58 Hammer-On Beam Clamp: HPH16HOK24, HPH16HOK58, HPH32HOK24, HPH32HOK58, HPH48HOK24, HPH48HOK58, HPH64HOK24 and HPH64HOK58 Secure a Hammer-On Beam Clamp to a flange using a hammer as shown in 5 & 6 below. Note: The HOK-24 is designed for flanges from 1/8 to 1/4" thick; the HOK-58 is designed for flanges from 5/16 to 1/2" thick. Part 1 2 3 4 UL Load Rating Designed for flanges HPH16HOK24 1" 1 & 2 20 88.96 1/8-1/4" 1 Hammer-On HPH J-, 1/8-1/4 flange, size 16 HPH16HOK58 1 3 & 4 20 88.96 5/16-1/2 1 Hammer-On HPH J-, 5/16-1/2 flange, size 16 HPH32HOK24 2 1 & 2 17 75.62 1/8-1/4" 2 Hammer-On HPH J-, 1/8-1/4 flange, size 32 HPH32HOK58 2 3 & 4 17 75.62 5/16-1/2 2 Hammer-On HPH J-, 5/16-1/2 flange, size 32 HPH48HOK24 3 1 & 2 20 88.96 1/8-1/4" 3 Hammer-On HPH J-, 1/8-1/4 flange, size 48 HPH48HOK58 3 3 & 4 20 88.96 5/16-1/2 3 Hammer-On HPH J-, 5/16-1/2 flange, size 48 HPH64HOK24 4 1 & 2 17 75.62 1/8-1/4" 4 Hammer-On HPH J-, 1/8-1/4 flange, size 64 HPH64HOK58 4 3 & 4 17 75.62 5/16-1/2 4 Hammer-On HPH J-, 5/16-1/2 flange, size 64 5 6 8

Mounting to a beam with an FM24 or FM58 Hammer-On Beam Clamp: HPH16ACFM24, HPH16ACFM58, HPH32ACFM24, HPH32ACFM58, HPH48ACFM24, HPH48ACFM58, HPH64ACFM24 and HPH64ACFM58 Secure a knock-on beam clamp to a flange using a hammer as shown in 5 & 6 below. Note: The ACFM24 is designed for flanges from 1/8" to 1/4" thick. The ACFM58 is designed for flanges from 5/16" to 1/2" thick. Both the ACFM24 & ACFM58 can be rotated 360. 1 2 3 4 Part UL Load Rating Designed for flanges HPH16ACFM24 1" 1 & 2 20 88.96 1/8-1/4" 1 Hammer-On HPH J-, Swivels 360, 1/8-1/4 Flange, size 16 HPH16ACFM58 1 3 & 4 20 88.96 5/16-1/2 1 Hammer-On HPH J-, Swivels 360, 5/16 1/2" Flange, size 16 HPH32ACFM24 2 1 & 2 20 88.96 1/8-1/4" 2 Hammer-On HPH J-, Swivels 360, 1/8-1/4 Flange, size 32 HPH32ACFM58 2 3 & 4 20 88.96 5/16-1/2 2 Hammer-On HPH J-, Swivels 360, 5/16 1/2" Flange, size 32 HPH48ACFM24 3 1 & 2 20 88.96 1/8-1/4" 3 Hammer-On HPH J-, Swivels 360, 1/8-1/4 Flange, size 48 HPH48ACFM58 3 3 & 4 20 88.96 5/16-1/2 3 Hammer-On HPH J-, Swivels 360, 5/16 1/2" Flange, size 48 HPH64ACFM24 4 1 & 2 20 88.96 1/8-1/4" 4 Hammer-On HPH J-, Swivels 360, 1/8-1/4 Flange, size 64 HPH64ACFM58 4 3 & 4 20 88.96 5/16-1/2 4 Hammer-On HPH J-, Swivels 360, 5/16 1/2" Flange, size 64 5 6 9

Mounting to a beam with a BC Beam Clamp: HPH16BC, HPH16ACBC, HPH32BC, HPH32ACBC, HPH48BC, HPH48ACBC, HPH64BC and HPH64ACBC Secure a screw-on beam clamp to a flange using a 3/8 socket driver or wrench as shown in 5, 6, 7, & 8 below. Tighten the bolt to 20 in-lb. Note: The BC & ACBC s are designed for flanges up to 1/2" thick. The ACBC can be rotated 360. 1 2 3 4 Part UL Load Rating Designed for flanges HPH16BC 1" 1 & 2 20 88.96 1 Beam Clamp HPH J-, 16 HPH16ACBC 1 3 & 4 20 88.96 1 Swivel 360 Beam Clamp HPH J-, size 16 HPH32BC 2 1 & 2 17 75.62 2 Beam Clamp HPH J-, 32 HPH32ACBC 2 3 & 4 20 88.96 1/8-1/2" 2 Swivel 360 Beam Clamp HPH J-, size 32 HPH48BC 3 1 & 2 20 88.96 3 Beam Clamp HPH J-, 48 HPH48ACBC 3 3 & 4 20 88.96 3 Swivel 360 Beam Clamp HPH J-, size 48 HPH64BC 4 1 & 2 17 75.62 4 Beam Clamp HPH J-, 64 HPH64ACBC 4 3 & 4 20 88.96 4 Swivel 360 Beam Clamp HPH J-, size 64 5 6 10

7 8 Mounting to a beam with an SSBC Spring Steel Beam Clamp: HPH16SSBC, HPH16ACSSBC, HPH32SSBC, HPH32ACSSBC, HPH48SSBC, HPH48ACSSBC, HPH64SSBC and HPH64ACSSBC Secure a screw-on beam clamp to a flange using a 3/8 socket driver, wrench or Phillips head screw driver as shown in 5, 6, & 8 below. Tighten the bolt to 20 in-lb. Note: The SSBC & ACSSBC s are designed for flanges up to 1/2" thick. The ACSSBC can be rotated 360. 1 2 3 4 11

5 6 7 8 Part Hoo k UL Load Rating Designed for flanges HPH16SSBC 1" 1 & 2 20 88.96 1 Spring Steel Beam Clamp HPH J-, size 16 HPH16ACSSBC 1 3 & 4 20 88.96 1 Swivel 360 Spring Steel Beam Clamp HPH J-, size 16 HPH32SSBC 2 1 & 2 17 75.62 2 Spring Steel Beam Clamp HPH J-, size 32 HPH32ACSSBC 2 3 & 4 20 88.96 1/8-1/2" 2 Swivel 360 Spring Steel Beam Clamp HPH J-, size 32 HPH48SSBC 3 1 & 2 20 88.96 3 Spring Steel Beam Clamp HPH J-, size 48 HPH48ACSSBC 3 3 & 4 20 88.96 3 Swivel 360 Spring Steel Beam Clamp HPH J-, size 48 HPH64SSBC 4 1 & 2 17 75.62 4 Spring Steel Beam Clamp HPH J-, size 64 HPH64ACSSBC 4 3 & 4 20 88.96 4 Swivel 360 Spring Steel Beam Clamp HPH J-, size 64 12

Mounting to a joist with an Angled Overhang (AO) or Vertical Overhang (VO) spring steel clip: HPH16AO, HPH16VO, HPH32AO, HPH32VO, HPH48AO, HPH48VO, HPH64AO and HPH64VO Secure an AO spring steel Z purlin clip or a VO14 C purlin clip to a joist using a hammer as shown in 5, 6, 7, & 8 below. Note: The AO14 is designed for flanges 1/8-1/4" thick. 1 2 3 4 5 6 13

7 8 Part UL Load Rating Designed for flanges HPH16AO 1" 1 & 2 20 88.96 1 Angled Overhang HPH J-, size 16 HPH16VO 1 3 & 4 20 88.96 1 Vertical Overhang HPH J-, size 16 HPH32AO 2 1 & 2 17 75.62 2 Angled Overhang HPH J-, size 32 HPH32VO 2 3 & 4 17 75.62 2 Vertical Overhang HPH J-, size 32 1/8-1/4" HPH48AO 3 1 & 2 20 88.96 3 Angled Overhang HPH J-, size 48 HPH48VO 3 3 & 4 20 88.96 3 Vertical Overhang HPH J-, size 48 HPH64AO 4 1 & 2 17 75.62 4 Angled Overhang HPH J-, size 64 HPH64VO 4 3 & 4 17 75.62 4 Vertical Overhang HPH J-, size 64 14

Mounting to threaded rod with a female threaded eye coupling: HPH16EH, HPH32EH, HPH48EH and HPH64EH Thread the eye coupling on to ¼-20 threaded rod as shown in 3, 4 & 5 below. 1 2 Part 3 4 5 Load Rating HPH16EH 1" 20 88.96 1 End ¼-20 HPH J-, size 16 HPH32EH 2 1 20 88.96 2 End ¼-20 HPH J-, size 32 HPH48EH 3 & 20 88.96 3 End ¼-20 HPH J-, size 48 HPH64EH 4 2 20 88.96 4 End ¼-20 HPH J-, size 64 All HPH J-s on pages 6 through 15 are special order. Call us for details and lead times. * Consult the manufacturer s instructions and load ratings before using on your application. www.platinumtools.com 15