Test all of your cables and wirings

Similar documents
CABLE TESTER. Models CA7024, CA7026 & CA7028. Call toll free (800) or visit

Fault Mapper Cable Length Meter & Fault Locator Alphanumeric TDR Model CA7024

C.A 6115N. Safety at all costs. IEE 16th: Electrical installation IEC/EN I E C. Insulation RCD. Earth. Loop. Continuity.

C.A 8332 C.A Display your network analysis all in picture format! OBSERVE, DIAGNOSE, MONITOR... Three Phase Power Quality Analysers

C.A 8332 C.A Advanced Test Equipment Rentals ATEC (2832) Display your network analysis all in picture format!

ENERIUM. A powerful solution for energy management and the environment

Test Equipment Solutions Datasheet

The experience of the Qualistar ensuring high performance

C.A 6117 C.A 6116N C.A 6113 Multi-function installation testers

MEMO & ULYS. Submeters. Complete solution for implementing a metering plan

LAN/Length Cable Tester TCT-2690 Pro

Digital Ground Resistance Tester. Model 4610 & 4610 Kits

MTX MTX 1052 & MTX 1054 oscilloscopes with FFT analysis, harmonic analysis and recording function

C.A C.A C.A C.A 8435 Power and Energy quality Analysers

F200 - F400 - F600 Series

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

Portable Multi-Channel Recorder Model DAS240-BAT

1507/1503. Insulation Testers. Technical Data. Features and benefits:

Fluke and

MIT480/2 Insulation testers

Data Sheet: TS 54 TDR

Insulation Testers and Earth Ground Testers

The future of installation testing is here. The Fluke 1650 Series Multifunction Testers

Fluke 1623 and GEO Earth Ground Testers. Technical Data. Stakeless testing

METREL Measuring and Regulation Equipment

HT FAMILY M70 METERS. Advanced DMM with safety and LAN cables test verifies HT ITALIA

Fluke T5 Electrical Testers. Fluke T and T5-600 Voltage, Continuity and Current Testers

Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

Firmware upgrades with new features are freely available and can be easily downloaded to the LT51 in the field.

Insulation resistance testing. A complete solution for every application

Insulation resistance testing. A complete solution for every person.

Datasheet: IntelliTone Pro 200 LAN Toner and Probe Series

Applications Features

Ultrasonic level transmitter, non-contact

Fluke 345. Power Quality Clamp Meter. The ideal meter for commissioning and troubleshooting modern electrical loads

CALYS Transportable documenting multifunction calibrator with high accuracy 0.01%

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

ODEN AT Primary Current Injection Test System

Obsolete Document. Dynatel

TSA 6000 System Features Summary

Electrical measurement technology. Re-invented.

ETL-40V CABLE TEST VAN SYSTEM. tel.: +380 (57) fax: +380 (57) high voltage testing equipment

MIT400/2 CAT IV Insulation testers

GROUND TESTERS For all of your Ground Testing needs...

HT COMBI419. Innovative meter designed to perform all safety test

PV200. Why buy the PV200? The most compact I-V curve tracer around.

C.A Earth and resistivity tester. Overview E N G L I S H

ASYC IV. METRIX revolutionizes multimeters! The 1 st multimeters with graphical colour screens. ... Plus unrivalled simplicity of use, as always!

A Clamp W/TRMS

Firmware upgrades with new features are freely available and can be easily downloaded to the LT51 in the field.

MultiMaster. Base Station Test Tools. Multi Purpose Base Station Tester. Introduction. Feature

PV210. Why buy the PV210?

PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks

DOCUMENT OBSOLETE. Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

Specifications for 3M Dynatel 2273M/M-iD Cable/Pipe and Fault Locators

INSULATION TESTER SERIES

Category 7 A /Class F A Products

SureTest Circuit Analyzers

TORKEL 900-series Battery Load Unit

Single phase meter with direct connection and pulse or Modbus RS485 output

Dynatel 900 Series Subscriber Loop Test Sets

TORKEL 900-series Battery Load Unit

Network Analyzer for Low-, Medium- and High-Voltage Networks

Tested Tough. Trusted Safe.

Hand-held temperature calibrator Model CEP3000

ELECTRICAL TESTING EQUIPMENT. CLM100 Cable Length Meter. DMEG3 Digital Insulation Resistance Tester. IRT3 Analog Insulation Resistance Tester

Eurotest 61557, Instaltest 61557

Amp Clamp W/True RMS

Pince Multimètre. Multimeter Clamp. Multimeterzange. Pinza Multimetro. Pinza Multímetro MX 670 / 675 E N G L I S H. User s manual

Top-Innovator MotorAnalyzer 1. Multi-purpose testers for electric motors and windings. Made in Germany Expect more.

Application Series. SunSet xdsl: TDR Testing Techniques for DSL Circuits

Digital Migration Radio PD605. DMR Standard Radio, Feature-Rich, Innovative Design, Compact Size, Integrates with Hytera Applications

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

Dynatel Cable/Pipe and Fault Locator 2273M Cable/Pipe, Fault and Marker Locator 2273M-iD

HT FAMILY 400 METERS. Innovative meter designed to perform all safety test and power measurements on single phase system

WaveAce 1000 and 2000 Oscilloscopes

INSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13

INSULATION TESTER SERIES. Flip the Cover. A Full Line-up of Insulation Testers to Suit Any Need. From Basic Testing to High Performance Analysis

HT1000/2 Series Copper Wire Analyser

NETWORK CONNECTIVITY SYSTEMS

Digital Ultrasonic Flaw Detector

Energy Explorer PROFESSIONAL POWER & HARMONICS ANALYSER

LAN tester EASYLAN. Instruction manual

isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems

C.A 6536 Megohmmeter

TDR1000/3 TDR1000/3P CFL510G TDR500/3. Time Domain Reflectometers. User Manual. Page 1 of 1

Locator Accessories DATA SHEETS. Accessory Range for Pipe & Cable Location Equipment

Digital insulation tester

CITS500s Controlled Impedance Test System

Leading the World in PV Test Solutions

Fluke 355 and 353 True-rms 2000 A Clamp Meters Versatile and rugged tools for applications with high currents

HT FAMILY 2000 METERS. Integrated meter for test verifies on electrical installations

ISOPALM 200. Cable fault locator

Insulation Testing. Distributor Training Program

METRAClip87 and 88 Clamp Multimeters

MIT415 Insulation tester

EYL225: nova225, Compact automation station

Standalone High Accuracy Transformer Analysis. Basic 0.02dB with class leading high frequency performance. RS232, USB and LAN as standard

USER MANUAL TDR CABLE FAULT LOCATOR TDR-420

TTR 100 Single-Phase Handheld TTR

Transcription:

Test all of your cables and wirings Identify and locate their faults C.A 7024 Fault Mapper TM Alphanumeric TDR C.A 7026 Fault Mapper TM Pro Graphic TDR C.A 7028 Wire Mapper TM Pro LAN Tester Location and identification of faults Extended measuring range: up to 3.500 m All types of cables: electric, coaxial, multipair Backlit graphic or alphanumeric LCD display Compact instruments: easy to carry and use

The full range of functions offered by the le Fault Mapper TM C.A 7024, the Fault Mapper TM Pro C.A 7026 and the Wire Mapper TM C.A 7028 make them ideal for communication engineers and technicians, for the teams assigned to detect faults in the field of telecommunications, for linemen, and for enterprises in the communications sector. The Wire Mapper TM can also be of use to IT managers and administrators working to locate faults or to upgrade an existing network installation. Built-in «Cable tracer» function In addition to their TDR functions, the C.A 7024 and C.A 7026 like the C.A 7028, have a sound frequency generator (810 Hz to 1110 Hz) that can be used in conjunction with a sound probe to facilitate locating faults and identifying pairs in a harness. Rugged, practical instruments To meet the most severe requirements of outdoor use, the instruments are encased in a rugged, reinforced fireproofed ABS housing. The backlit display screen is made of impact-resistant ABS. Waterproof and dustproof (IP54), the instruments are designed and built in conformity with international quality standards. In addition, their small size makes them easy to carry and use. Battery charge level indication When powered up, the C.A 7024, C.A 7026 and C.A 7028 automatically display the remaining battery life, so the operator knows whether the instrument is ready for a long-duration test. To save power, the instrument automatically switches to standby after 3 minutes of non-use.

Professional and inexpensive, the Fault Mapper TM C.A 7024 (digital) and the Fault Mapper TM Pro C.A 7026 (graphic) are portable time-domain reflectometers (TDR) designed to detect and locate faults in shielded, coaxial, and communication cables over maximum distances of 2,000 m and 3,500 m, respectively. The Wire Mapper TM C.A 7028 is a professional wiring tester and fault identifier for dataa and voice networks and installed copper connecting wires. C.A 7024 / C.A 7026 Fault Mapper TM and Fault Mapper TM Pro Alphanumeric or graphic TDR Extended measuring range The Fault Mapper TM C.A 7024 and the Fault Mapper TM Pro C.A 7026 detect and locate common cable faults. They combine low cost with high quality and reliability. They cover their full measurement range (C.A 7024 : 2,000 m / 6,000 ft; C.A 7026: 3,500 m / 11,700 ft) on all types of cables. In other words, they make full use of their capabilities when used on high-loss cables, such as twisted pairs and telephone wires, over long distances. Coaxial cable Shielded cable Twisted pairs Multiconductor cable on all types of cables The C.A 7024 has an built-in library of common cable characteristics, which the user can easily select, so there is no need to look up the propagation velocity of each cable. For cables not catalogued in the internal library, the operator can select the relative propagation velocity manually in a range from 20 to 99%. Thanks to its automatic compensation device, there is no need to select the impedance of the cable. The C.A 7026 is suited to all types of communication cables. Their impedance can be selected from among 50, 75, and 100 Ω, typical of metallic communication cables, in particular coaxial cables and twisted pairs. The relative propagation velocity can be adjusted from 20 to 99% in 1% increments. A new technology for fast and accurate measurements The Fault Mapper TM uses the Fast Edge Step TDR technology for improved range and resolution. The short rise time of the test pulse yields better resolution for the short ranges. The energy contained in the pulse ensures maximum range in all cables. For its part, the Fault Mapper TM Pro has an automatic measurement scale linked to the position of the cursor. The instrument automatically selects the appropriate range from among its five measuring scales. This function cuts the time needed to locate a fault. Any faults detected and all messages are displayed in the language selected by the user at the time of configuration (French, English, German, Spanish, Portuguese, Italian). Check of the length of cable on a reel using the C.A 7024 In addition to short-circuits and open-circuits, the Fault Mapper TM Pro detects shunts, junctions, deterioration caused by infiltration of water, and other impedance anomalies. Effective fault detection The Fault Mapper TM clearly and directly indicates the nature of the fault detected (open-circuit or short-circuit) and the distance to the fault. An operating mode suited to the situation For simple faults, the C.A 7026 can be used in either single-pulse or continuous mode. For more complex faults, its continuous mode facilitates the detection of intermittent faults. Voltage alarm and stopping of test Before each test, the C.A 7024 and the C.A 7026 check the voltage of the cables to which they are connected. If the instrument detects a voltage greater than about 10 V AC/DC, it warns the user and stops the test. The Fault Mapper TM Pro is also protected against overvoltages up to 250 V AC/DC. Test of telephone lines using a C.A 7026 on a switchboard

C.A 7028 Wire Mapper Pro LAN Tester Cutting-edge technology Le Wire Mapper TM C.A 7028 includes a unique function called EDT (End Discrimination Technology). This function considerably reduces the costs of commissioning installations, because the wiring diagram displayed on the screen clearly indicates the nature and position of the fault detected. The instrument clearly and precisely indicates all faults in the cables, and their lengths, on its graphic screen. «ID01» means that the cable terminated by identifier n. 1 has a short-circuit on its 1-2 pair. Examples of diagrams of identification of open-circuit and crossed pairs in cables Wiring subject to many international standards The Wire Mapper TM measures the length of the cable before or after installation, identifies all common faults on horizontal wiring diagrams installed as per TIA568 A/B, ISO, EN, USOC and RNIS standards: open-circuit, short-circuited, crossed, separated or inverted pairs, and shield/screen continuity. Here the Wire Mapper TM C.A 7028 is used to locate, on a switchboard, the cable serving an office several tens of meters away. A whole network tested by a single instrument The remote identifiers of the C.A 7028 are active and inform the remote operator when a test is over and whether it is PASS/FAIL. The instrument is delivered with an identifier bearing the number «1». Using additional identifiers («2» to «9»), the Wire Mapper TM can test and identify up to 10 links from the switchboard. The Wire Mapper TM can also be used to check that a cable already installed is free of faults. Safety first Before checking an installed wiring network, the Wire Mapper TM alerts the operator if telephone services are active on the cable tested (10 Mbps, 100 Mbps, Token Ring, etc.). This prevents accidental testing of an active LAN network and eliminates the associated risk of damage to the network or to the instrument.

Type of instrument Maximum distance Types of cables tested Cable selection Relative propagation velocity Cable impedance Faults detected Measurement Test modes Resolution Accuracy Display Protection / Safety Cable location and identification Dimensions Mass Environmental conditions Protection Delivery condition Power supply / Battery life Standards C.A 7024 C.A 7026 Fault Mapper Fault Mapper Pro Alphanumeric TDR (time-domain reflectometer) Graphic TDR 2 000 m - 6000 ft 3500 m - 11700 ft shielded, coaxial, twisted pairs, multiconductor internal library Automatic impedance selection manual selection for the cable to be tested, from 0 to 99% automatic selection selected from among 50, 75, and 100 Ohm open circuits and short-circuits short-circuits, open circuits, shunts, junctions, deterioration caused by infiltration of water and other impedance anomalies open-circuit, short-circuited, crossed, or separated pairs, short-circuits between pairs, pair inversions, and shield/screen continuity end of installed link or connecting wire containing faults; fault detection display of distance to fault location with a sound-emitting probe length of cables (in m or ft) Single pulse pulse mode: one test pulse emitted for each press continuous mode: several test pulses per second Length of cable or link (in m or ft) 0.1 m up to 100 m, then 1 m Approximately 1% of range selected +/- 2% if relative propagation velocity +/- 1% of range if relative propagation velocity +/- 5% of length correctly configured correctly configured alphanumeric LCD screen 128 x 64 pixels voltage alert (> 10 V AC/DC) and test stopped graphic LCD screen 128 x 64 pixels alerting of active services on the cable built-in sound frequency generator 165 x 90 x 37 mm 350 g Storage temperature: -20 to +70 C (-4 to +158 F) Operating temperature: 0 to +40 C (32 to +112 F) IP 54 - ABS housing test wires with alligator clips / carrying case 4 AA batteries (1.5 V) / 7.5 h in continuous use; 4,000 hours on standby safety: IEC61010-1/EN 60950 - EMC: BS/EN 61326-1 - CE C.A 7028 Wire Mapper Pro LAN wiring tester 150 m - 500 ft UTP & STP (SSTP & FTP) as per TIA568 A/B, ISO, EN, USOC and RNIS standards UTP, STP emitter: 165 x 90 x 37 mm identifier: 65 x 52 x 25 mm 350 g / 40 g 2 RJ 45 cords / 1 identifier / carrying case 4 AA batteries (1.5 V) / > 100 hours in continuous use To order C.A 7024 Fault Mapper TM alphanumeric TDR P01.1296.01 C.A 7026 Fault Mapper TM Pro graphic TDR P01.1297.01 C.A 7028 Wire Mapper TM Pro LAN tester P01.1295.01 Accessories Set of identifiers n. 2 to 5 for C.A 7028 Set of identifiers n. 6 to 9 for C.A 7028 Carrying bag P01.1019.94 P01.1019.95 P01.2985.32 TEST & MEASUREMENT DIVISION 906 211 066 - Ed 1-12/03 - Characteristics subject to modifications according to technological developments - komako FRANCE 190, rue Championnet 75876 PARIS Cedex 18 tél: +33 1 44 85 44 85 Fax: +33 1 46 27 73 59 e-mail: export@chauvin-arnoux.fr www.chauvin-arnoux.fr UNITED KINGDOM Waldeck House - Waldeck Road MAIDENHEAD SL6 8BR Tél: 01628 788 888 Fax : 01628 628 099 e-mail: info@chauvin-arnoux.co.uk www.chauvin-arnoux.co.uk LEBANON P.O. BOX 60-154 1241 2020 JAL EL DIB (BEIRUT) Tél: +961 1 890 425 Fax: +961 1 890 424 e-mail: camie@chauvin-arnoux.com www.chauvin-arnoux.com