Energy Management Compact Power Transducer Type CPT-DIN Basic version

Similar documents
Energy Management Compact Power Transducer Type CPT-DIN Advanced version

Energy Management. Type WM14-DIN Basic Version. How to order WM14-DIN AV5 3 D PGX. Type Selection. Input specifications. CptBSoft

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications.

Power analyzers and Energy Meters Power Analyzer Type WM14-96

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

Energy Management. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Type Selection. Input specifications

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

Model Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output.

Energy Management Energy meters Type EM2-DIN

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN

Energy Management Modular Power Analyzers Type WM2-96

MID. Energy Management Energy Meter Type EM33 DIN. Product Description. How to order EM33 DIN AV3 3 X XS PF. Type Selection EM33 DIN

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN

Energy Management Energy Meter Type EM21 72R Retro-Fit

Energy Management Energy Analyzer Type EM210 MID

Energy Management Energy Meter GM3T E GM3T-RS485 E

Energy Management Energy Analyzer Type EM210

Energy Management Modular Smart Power Transducer Type SPT-90

Energy Management Energy Analyzer Type EM24 DIN

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40

Energy Management Modular Smart Power Quality Analyzer Type WM3-96

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

MID. Energy Management Energy Analyzer Type EM Product Description. How to order EM26 96 AV5 3 H O3 S1 PF A. Type Selection EM26 96

Energy Management Energy Meter GM3D

ENGLISH WM3-96. ISE, Inc Royalton Rd. - Cleveland, OH USA - Tel: (440) Fax: (440)

Energy Management Energy Analyzer Type EM280-72D

Energy Management Energy Analyzer Type EM270-72D

Energy Management Modular Power Quality Transducer Type PQT-90

Energy Management Energy Analyzer Type EM24 DIN

Energy Management Energy Meter Type EM111

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM4-96

Energy Management Energy Meter Type EM112

Energy Management Smart Modular Power Analyzer Type WM30 96

Energy Management Energy Meter Type EM340

Energy Management Energy Meter Type EM110

Energy Management Energy Analyzer Type EM112

EN61036 EN61268 CARLO GAVAZZI

Energy Management Energy Meter Type EM110

Energy Management Energy Analyzer Type EM111

Energy Management Energy Analyzer Type EM24 DIN

Energy Management Modular Smart Power Quality Analyzer Type WM5-96

ENGLISH WM2 - DIN / EM2 - DIN OPERATING INSTRUCTIONS. General features 2. WM2-DIN Technical features 3. EM2-DIN Technical features 9.

Energy Management Energy Analyzer Type EM24 DIN

emeter1 Single-phase energy meter emeter3 Three-phase energy meter User manual NO POWER & SIGNAL CABLES TOGETHER READ CAREFULLY IN THE TEXT!

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Energy Management Smart Modular Power Analyzer Type WM30 96

Energy Management Smart Modular Power Analyzer Type WM30 96

Multimeter 500CVD21 RTU500 series

RTU560. Multimeter 560CVD03. Power Measuring Display. Characteristics. Application. Data Sheet Multimeter 560CVD03

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

Digital Multifunction Instrument - Rish Master 3440

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

EM-72 Electricity Meters for Current Transformers

Energy Management Smart Modular Power Analyzer Type WM40 96

Energy Management Smart Modular Power Analyzer Type WM30 96

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

Energy Management Smart Modular Power Analyzer Type WM40 96

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

Energy Management Modular Smart Power Quality Analyzer Type WM5-96

ENGLISH. General features 2. Technical features 2. Installation 5. Preliminary operations 7. Front panel description 8.

DM-III Multitest & DM-III Multitest F Power Quality Recorders

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

Data Sheet. RISH Master Record %THD

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

PRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

Centrale de mesure Power Meter PM500 Merlin Gerin

DM-III MULTITEST Power Quality Recorder

PQA823 PQA824 Rel /01/2007

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

3-phase meter with direct connection and pulse or Modbus RS485 output

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID

Technical Data Sheet. x1000. kwh R Y B

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

Power Meter Series PM3200 Functions and characteristics

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

AMIK 200 / 201 Technical Data Sheet

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

PQA823 PQA824 Rel /03/2007

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Monitoring Relays 3-Phase Active power direction Types DWB03, PWB03

Monitoring Relays 3-Phase Load Guard Types DWB01, PWB01

Monitoring Relays 1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

Monitoring Relays 1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

Multimeter 560CVD11 Data sheet

Application and features

MEASURING TRANSDUCERS PROGRAMMABLE TRANSDUCERS

Integra 1560 and 1580 Digital Transducer Systems

Transcription:

Energy Management Compact Power ransducer ype CP-DI Basic version RS serial port on request Alarms (only from serial communication port) V, An Class (active energy) Class (reactive energy) Accuracy ±0..S. (current/voltage) Compact Power transducer Instantaneous variables data format: 4 digit Energies data format: 8 digit System variables and phase measurements: W, W dmd, W dmd max, var, VA, VA dmd, P, V, A, An, A dmd, A max, A dmd max, Hz Energy measurements: kwh and kvarh Hour counter ( DG) RMS meas. of distorted sine waves (voltages/currents) Power supply: 90 to 60VAC/DC and 8 to 60VAC/DC Protection degree (front): IP0 Dimensions: 4x8.x98.mm RS4/48 serial port Product Description ype Selection Range codes -phase compact power transducer. Particularly recommended for the measurements of the main electrical variables. Housing for DI-rail mounting, protection degree IP0 as standard, and RS48 or RS serial port. Parameters programmable by means of CptBSoft. System How to order Model Range code System Power supply Outputs Option How to order Power supply CP-DI AV H S BX CptBSoft-kit CptBSoft: software to program the working parameters of the transducer and to read the energy and the instantaneous variables. he kit includes the communication cable. Outputs AV: AV6: 400/(690)V -/(6)AAC V-: 8 V to 460 V V-: 0 V to 800 V 0/(08)V -/(6)AAC V-: 4 V to 4 V V-: 8 V to 0 V Phase current: 0.0A to 6A eutral current: 0.09 to 6A :, or -phase, unbalanced and balanced load, with or without neutral : --phase, balanced load (*) : 8 to 60VAC/DC H: 90 to 60VAC/DC (*) Pay attention: the -phase measurement is carried out as one current and one phase to neutral voltage measurement. S: RS48 port S: RS port Options BX: Basic features Input specifications Rated inputs Current (current transformers) Voltage 4 Accuracy (RS48/RS) with C= and V= AV: (@ C ± C, R.H. 60%) 0W-VA-var, S:0V, 400V; AV6: 8W-VA-var, S: V, 00V Current 0. to 6A: ±(0.% S DG) 0.0A to 0.A: ±(0.% S DG) eutral current 0. to 6A: ±(.% S DG) 0.09A to 0.A: ±(.% SDG) Phase-phase voltage ±(.% S DG) Phase-neutral voltage ±(0.% S 0.DG) Active and Apparent power, 0. to 6A: ±(%S DG); 0.0A to 0.A: ±(%SDG) Reactive power 0. to 6A: ±(% S DG); 0.0A to 0.A: ±(% S DG) Active energy Class (I start up: 0mA) Reactive energy Class (I start up: 0mA) requency ±0.Hz (48 to 6Hz) Additional errors Humidity 0.% S, 60% to 90% RH emperature drift 00ppm/ C Sampling rate 400 samples/s @ 0Hz 00 samples/s @ 60Hz Measurement refresh time 00ms Measurement format Instantaneous variables 4 DG (Max indication: 9999) Energies 9 DG (Max indication: 999 999 99.9) Hour counter DG (Max. indication: 9 999 9.99) Specifications are subject to change without notice CP-DIBDS08060

CP-DI Input specifications (cont.) Measurements ype Coupling type Crest factor Input impedance Current, voltage, power, power factor, frequency, energy, hour counter RMS measurement of distorted waves. Direct <, max 0A peak 400/690V - (AV) MΩ ±% 0/08V - (AV6) 4 KΩ ±% Current 0.0Ω requency Overload protection Continuos voltage/current or 00ms: voltge/current 48 to 6 Hz (max values) AV: 460V, 800V /6A AV6: 4V, 0V /6A AV: 800V, 80V /6A AV6: 0V, 46V /6A Serial Port Specifications RS4/RS48 ype Connections Addresses Protocol Data (bidirectional) Dynamic (reading only) Static (writing only) Data format RS Configuration Bus Connections Baud-rate Data format Halfduplex communication Multidrop bidirectional (static and dynamic variables) or 4 wires, max. distance 00m, termination directly on the instrument to selectable via software MODBUS/JBUS (RU) System, phase variables and energies All configuration parameters start bit, 8 data bit, RJ (-wire) for special cable 4800 bits/s start bit, 8 data bit, no parity, stop bit Baud-rate Insulation RS ype Connections Address Protocol Baud-rate Insulation no parity, stop bit 9600 bit/s By means of optocuplers, kv RMS output to measuring input. 4kV RMS output to power supply Halfduplex communication Point to point connection -wire, max. distance m to selectable via software MODBUS/JBUS (RU) 9600bits/s other characteristics like R4/RS48 port By means of optocuplers, kv RMS output to measuring input. 4kV RMS output to power supply CptBSoft: parameter programming and reading data software CptBSoft Software functions System selection -ph. with or without, unbal. -phase balanced C V -phase ARO, unbalanced -phase Single phase ransformer ratio C to 999 V/P.0 to 99,9 ilter Operating range iltering coefficient to 6 Multi language software to program the working parameters of the transducer and to read the energies and the instantaneous variables. he program runs under Windows 9/98/98SE/000/ /XP. 0 to 99.9% of the input electrical scale Working mode Data access ilter action Alarms Measurements, alarms, serial out. (fundamental var: V, A, W and their derived ones). Programmable, for the V and An (neutral current). ote: the alarm is only a status transmitted via communication port. Specifications are subject to change without notice CP-DIBDS08060 Reset wo different working modes can be selected: - management of a local RS48 network; - management of communication from a single instrument to PC (RS); By means of RS serial port, RS48 serial port or RS configuration port. Independent alarm (V, An) max: A dmd, W dmd all energies (Wh, varh) hour counter

CP-DI Specifications Auxiliary power supply 90 to 60VAC/DC 6 to 60VAC/DC Power consumption AC: 4. VA DC: 4W General Specifications ront ED s Power on Diagnostics Operating temperature Storage temperature Installation category Insulation (for minute) Dielectric strength Green Green (X data) Red (RX data) 0 to 0 C ( to ) (RH < 90% non condensing) -0 to 60 C (4 to 40 ) (RH < 90% non condensing) Cat. III (IEC 60664, E60664) 4kVAC RMS between mesuring inputs and power supply. kvac/dc between mesuring inputs and RS48/RS/programming port (RJ) 4kVAC RMS between power supply and RS48/RS/programming port. 4kVAC RMS (for min) EMC Emissions Immunity Pulse voltage (./0µs) Safety standards Measurement standards Approvals Connections (6) A Max cable cross sect. area. mm Housing Dimensions (WxHxD) Material Mounting Protection degree Weight E6000-6-, E60688 residential environment, commerce and light industry E6000-6- industrial environment. E6000-4- IEC60664, E60664 IEC60688, E60688 CE, curus, ccsaus Screw-type 4 x 8. x 98. mm ABS self-extinguishing: U 94 V-0 DI-rail IP0 Approx. 00 g (pack. incl.) Measurements available on the communication port Variables that can be retrasmitted -phase system 4-wire connection Variables otes V V V V V V A A A A dmd A dmd A dmd dmd = demand (integration time selectable from to 0 minutes) An An alarm An alarm: neutral current alarm W W W P P P var var var VA VA VA VA system W system var system VA dmd W dmd Hz dmd = demand (integration time (system) (system) selectable from to 0 minutes) W dmd MAX Maximum sys power demand Wh varh V system V alarm P system V alarm: alarm status if V is not within the two set limits. A MAX max. current among the three phases A dmd max max. dmd current among the three phases h working hour counter Specifications are subject to change without notice CP-DIBDS08060

CP-DI Waveform of the signals that can be measured igure A Sine wave, undistorted undamental content 00% Harmonic content 0% A rms =.0 A Accuracy igure B Sine wave, indented undamental content 0...00% Harmonic content 0...90% requency spectrum: rd to 6th harmonic Additional error: <% S igure C Sine wave, distorted undamental content 0...90% Harmonic content 0...0% requency spectrum: rd to 6th harmonic Additional error: <0.% S Wh, accuracy (RDG) depending on the current varh, accuracy (RDG) depending on the current Error Error 4% % 6% % 0% 0% -% -4% -% -6% P= P=0. or C0.8 0.A (0.0Ib) 0.A (0.Ib) 0.A (0.Ib) A (0.Ib) A (Ib) A (Ib) Accuracy limits (Active energy) (6A) Start-up current: 0mA 6A (Imax) 6A (Imax) sinϕ= sinϕ=0. 0.A (0.0Ib) 0.A (0.0Ib) 0.A (0.0Ib) 0.A (0.Ib) A (Ib) A (Ib) Accuracy limits (Reactive energy) (6A) Start-up current: 0mA 6A (Imax) 6A (Imax) Used calculation formulas Phase variables Instantaneous effective voltage System variables Equivalent three-phase voltage Energy metering Instantaneous active power Instantaneous power factor Instantaneous effective current Instantaneous apparent power Instantaneous reactive power hree-phase reactive power eutral current An = A A A hree-phase active power hree-phase apparent power hree-phase power factor (P) Where: i = considered phase (, or ) P = active power Q = reactive power t, t =starting and ending time points of consumption recording n = time unit t = time interval between two successive power consumptions n, n = starting and ending discrete time points of consumption recording 4 Specifications are subject to change without notice CP-DIBDS08060

CP-DI Wiring diagrams system type selection: -ph, -wire ig. -ph, -wire ig. -ph, -wire ig. 8 8 8 0 6 Direct connection C connection C connection = 60 ma (8 to 60VAC/DC) ma (90 to 60VAC/DC) -ph, 4 wire, unbalanced load ig. 4 -ph, -wire, unbalanced load ig. -ph, -wire, unbalanced load ig. 6 8 0 8 0 0 6 8 6 8 6 8 Direct connection ARO connection ARO and V/P connection Specifications are subject to change without notice CP-DIBDS08060

CP-DI Wiring diagrams system type selection: (cont.) -ph, 4-wire, unbalanced load ig. -ph, 4-wire, unbalanced load ig. 8 -ph, -wire, unbalanced load ig. 9 8 0 8 0 0 6 8 6 8 6 8 C connection C and V/P connection C connection = 60 ma (8 to 60VAC/DC) ma (90 to 60VAC/DC) -ph, -wire, unbalanced load ig. 0 -ph, -wire, balanced load ig. -ph, 4-wire, balanced load ig. 0 0 8 6 8 C and V/P connection C connection C and V/P connection 6 Specifications are subject to change without notice CP-DIBDS08060

CP-DI Wiring diagrams system type selection: -ph, -wire ig. -ph, -wire ig. 4 -ph, 4-wire, balanced load ig. Direct connection C connection C connection = 60 ma (8 to 60VAC/DC) ma (90 to 60VAC/DC) -ph, 4-wire, balanced load ig. 6 C and V/P connection Specifications are subject to change without notice CP-DIBDS08060

CP-DI RS48 Serial port connection RX - X - X- RX- X- RX- X- RX- SIU-PC RS48 RS X RX GD ast instrument X RX GD X RX GD...n Instrument GD X RX 4-wire connection of RS48 serial port, the terminalization must be carried out only on the last instrument of the network RX - X - X- RX- X- RX- X- RX- SIU-PC RS48 RS X RX GD ast instrument X RX GD X RX GD...n Instrument GD X RX -wire connection of RS48 serial port, the terminalization must be carried out only on the last instrument of the network Easy programming RS Serial port connection RJ communication port for parameters programming. he configuaration of the transducer can be easily performed by means of CptBSoft. CptBSoft-kit includes also a connection cable (RJ 6 pole RS 9 pole female). RX X GD 9 6 8 Specifications are subject to change without notice CP-DIBDS08060

CP-DI Outputs connections RS48 X- RX- RS RX X GD X RX GD 4 6 Power O V 9 () () () () 8 0 () () () I 6 8 Compact Power ransducer Diagnostics CP-DI ront Panel Description ~ - ~. ront panel. Power O ED 4 6 Power O V 9 () () () () 8 0 () () () I 6 8. Diagnostics ED 4. Configuration bus (RJ connector). Connections screw terminals Compact Power ransducer Diagnostics CP-DI 4 Dimensions and Panel Cut-out 8.mm 4 6 Power O V 9 () () () () 8 0 () () () I 6 8 Compact Power ransducer Diagnostics CP-DI 6.mm 4mm 98.mm Specifications are subject to change without notice CP-DIBDS08060 9