Baro Transmitter PTB x1.073

Similar documents
Brightness Transmitter

Hygro-ThermoTransmitter-compact xxx

Brightness Transmitter - direction-independent xxx

Wind Transmitter First Class Advanced Classified according to IEC ( )

Precipition Sensor with analogue Intensity Output ,

Wind Direction Transmitter - compact - GMR, analogue output xxx xxx

Precipitation Monitor ,

Wind Direction Transmitter First Class analogue output x0.1xx

FINAL. Hygro-ThermoTransmitter-compact xxx xxx MEETINSTRUMENTATIE. Instruction for use /06/ x4.0xx/1xx/4xx/8xx...

Wind Transmitter - with frequency output xx.xxx

Wind Transmitter - compact

Wind Transmitter - with analogue output xxx

Wind Direction Transmitter - compact - with Poti Output xx.712

Baro Transmitter xxx

Wind Transmitter compact xx

Wind Direction Transmitter - compact - TMR, analogue output x.xxx xxx

Precipitation Transmitter / 008 / 009 / 010 / 011 / 107 / / 009

Wind Direction Transmitter First Class analogue output x0.1xx

Combined Wind Transmitter - with analogue output xxx

Digital Anemometer

Wind Transmitter First Class

Wind Transmitter First Class / 141 / / 141 / 161

Wind Direction Transmitter - compact - with Poti Output xx.712

Sensor PAR xxx

Wind Direction Transmitter - compact - GMR, analogue output xxx

Wind Direction Transmitter First Class Low Power Device with digital output, 8 Bit serial-synchronous x0.000

DPS 100 DPS 100. Gauge- / Differential- / Absolute Pressure Transmitter

Wind Direction Transmitter - compact

Wind Direction Transmitter - compact - with serial output x0.x00

Instruction for Use /05/09. Wind Transmitter - compact x0.xxx x0.xx x0.xx0

Precipitation transmitter

Flow sensor HVAC 100 (548000) Instruction for use. Imprint: Copyright all rights reserved Version Subject to modifications

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Wind Direction Transmitter First Class - Device with digital output, RS Wind velocity signal acquisition x0.400

CS105 BAROMETRIC PRESSURE SENSOR

HD 9408T BARO - HD 9408TR BARO HD 9908T BARO - HD 9408PS 50

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Operating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601

Appendix A: Specifications

Operating Instructions

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Miniature resistance thermometer Model TR33, thread-mounted

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

VariTrans P V. Safe and Sound.

Precipitation Transmitter xxx / xxx

INSTRUCTIONS MODELS AVX-CA-SEMA TEST JIG FOR USE WITH AVTECH AVR-EB2A-B REVERSE RECOVERY TEST SYSTEMS SERIAL NUMBER:

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

THM80X Series Industry degree high accuracy Temp. & humidity transmitter

Temperature Transmitters TMT 136, TMT 137

Resistance thermometer Model TR31, miniature design

Resistance thermometer Model TR30, compact design

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

Pressure transmitter for general industrial applications Model A-10

INSTRUCTIONS MODEL AVC MONOCYCLE GENERATOR MODULE SERIAL NUMBER:

Flush pressure transmitter For viscous and solids-containing media Model S-11

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

METEOROLOGICAL INSTRUMENTS

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

PRetrans Table of contents

PHOENIX CONTACT

Submersible pressure sensor For oils and fuels Model LF-1

USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2

Resistance thermometer Model TR30, compact design

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Differential pressure sensors

OEM pressure transmitter For mobile working machines Model MH-3

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

Relative and absolute pressure transmitter type 528

OPTITEMP TT 20 Technical Datasheet

Operating Manual. Differential Pressure Transmitter DPS 100

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

QPM Series Indoor Air Quality Duct Sensors

INSTRUCTIONS MODELS AVX-TFR-MELF TEST JIG FOR USE WITH AVTECH AVR-EBF6-B FORWARD RECOVERY TEST SYSTEMS SERIAL NUMBER:

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Pressure transmitter For general industrial applications Model A-10

Endress Hauser. SmarTec M CLD 133 Conductivity Measurement

Resistance thermometer Model TR30, compact design

High-quality pressure transmitter For general industrial applications Model S-10

Digital indicator for panel mounting With multi-function input Model DI25

Pressure transmitter For general industrial applications Model A-10

Indicator for panel mounting Model

Level Measurement silometer FMX 570

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Submersible pressure sensor For water and wastewater Model LW-1

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

UMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks

CDG. Carbon Dioxide - User Manual Gas Detector. 1 Intended Use. 2 Functional Description. 3 Installation. 4 Electrical Connection.

METEOROLOGICAL INSTRUMENTS

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Transcription:

THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021570/04/08 Baro Transmitter PTB 110 3.1158.x1.073 ADOLF THIES GmbH & Co. KG Hauptstraße 76 37083 Göttingen Germany Box 3536 + 3541 37025 Göttingen Phone ++551 79001-0 Fax ++551 79001-65 www.thiesclima.com info@thiesclima.com

Contents 1 Models available... 2 2 Application/Construction/Mode of Operation... 2 3 Mechanical Mounting... 2 3.1 Operating modes... 3 3.2 Maintenance... 3 4 Electrical Mounting... 4 5 Evaluation... 5 6 Technical Data... 6 7 EC-Declaration of Conformity... 7 1 Models available Description Order-No. Meas. Range Output Operating voltage Baro Transmitter PTB 3.1158.01.073 800... 1060 hpa 0... 5 V DC 10...30 V DC Baro Transmitter PTB 3.1158.11.073 600... 1060 hpa 0... 5 V DC 10...30 V DC 2 Application/Construction/Mode of Operation The Baro Transmitter is equipped with a silicon capacitive pressure sensor. The sensor has been especially designed for accurate and stable measurement of barometric pressure. The Baro Transmitter have 0...5 VDC output and they can be used in either three or four wire connection. Shutdown mode is jumper selectable. With the shutdown mode enabled the barometers can be turned on/off by using an external TTL level signal. 3 Mechanical Mounting The Baro Transmitter is used with air in non-conducting gases. Remark: The use with liquids or corrosive gases may damage the instrument! 2-8 021570/04/08

The baro transmitter is equipped with a 1/8 hose connection, and is typically installed indoors or in weatherproof housing. The baro transmitter should be installed vertically (connection clamp downwards) to prevent any ingress of condensed water. 3.1 Operating modes The Baro Transmitter have two operating modes: normal and shutdown. In the normal operating mode the barometer measures continuously when powered-up. In the shutdown operating mode the barometer is turned on/off using an external TTL level signal. The baro Transmitter is supplied from factory in the normal operating mode The selection of the respective mode of operation is carried out by setting (= standard mode) or deleting (= shutdown mode) of a POWER-ON JUMPER which is situated below the covering of the housing top side. The POWER-ON JUMPER is located on the board, on the right, beside the screw. Remark: The other jumpers are factory-set, and cannot be changed. 3.2 Maintenance The baro transmitter is factory calibrated. 3-8 021570/04/08

4 Electrical Mounting The ground connections AGND and GNG are in the same electrical potential. The connection is carried out in four- or three-wire-technology (see fig. 1 and 2). Four wire connection is recommended to avoid the voltage drop in the supply ground line, which can affect the accuracy of the pressure measurement. In normal operating mode no connection to the EXT.TRIG terminal is recommended. The barometers are protected against reverse operating voltage. Fig. 1 Four Wire Connection Fig. 2 Three Wire Connection Pin assignment of the terminal strip: Pin Nr. Terminal Strip Function 1 EXT TRIG External trigger input Pin 1 is used as a power on/off switch in shutdown mode as follows: Power off 0 VDC Power on 5 VDC 2 AGND Analogue signal ground 3 GND Ground 4 SUPPLY Supply voltage 5 VOUT Voltage output 4-8 021570/04/08

5 Evaluation The barometric pressure (P) can be calculated from measured output voltage (U) using a equation: P = P low P + U range range U out P low Lower limit of the pressure range (hpa) P range Pressure full range (hpa) U range Voltage full range (V) U out Measured output voltage (V) Example for 3.1158.01.073: Pressure range: Voltage output: Measured output voltage: 4 V 800...1060 hpa 0...5 V (1060-800)hPa P = 800 hpa + 4V = 808hPa 5V Example for 3.1158.11.073: Pressure range: Voltage output: Measured output voltage: 4 V 600...1060 hpa 0...5 V (1060-600)hPa P = 600 hpa + 4V = 968hPa 5V 5-8 021570/04/08

6 Technical Data Measuring range Electrical output Ambient temperature Humidity range Measuring element 3.1158.01.073 3.1158.11.073 800... 1060 hpa 600 1060 hpa 0... 5 V DC -40... +60 C Non condensing Accuracy Linearity ±0.25 hpa Hysteresis Repeatability Silicon capacitive sensor ±0.03 hpa ±0.03 hpa Calibration uncertainty ±0.15 hpa Total accuracy @ +15...+25 C ±0.3 hpa Long-term stability Operating voltage Supply voltage control Current consumption Load resistace Load capacitance @ 0... +40 C ±0,6 hpa @ -20... +45 C @ -40... +60 C Pressure fitting 1/8 Minimum pressure limit Maximum pressure limit Electrical connector Weight Housing classification Dimensions ±1,0 hpa ±1,5 hpa ±0.1 hpa / year 10... 30 V DC with TTL High trigger < 4 ma < 1 µa in shutdown mode 10 k Ω Minimum 47 nf Maximum 0 hpa absolut 2000 hpa absolut Removable connector for 5 wires 0,090 kg IP32 68,4 x 97,3 x 28,1 mm (WxHxD) 6-8 021570/04/08

7 EC-Declaration of Conformity Document-No.: 000111 Month: 06 Year: 08 Manufacturer: A D O L F T H I E S G m b H & C o. K G Hauptstr. 76 D-37083 Göttingen Tel.: (0551) 79001-0 Fax: (0551) 79001-65 email: Info@ThiesClima.com Description of Product: Baro Transmitter Article No. 3.1158.01.073 3.1158.11.073 3.1158.00.075 3.1158.10.075 specified technical data in the document: 021569/04/08; 021485/03/06 The indicated products correspond to the essential requirement of the following European Directives and Regulations: 2004/108/EC 2006/95/EC DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89/336/EEC DIRECTIVE 2006/95/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 12 December 2006 on the harmonisation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits 552/2004/EC Regulation (EC) No 552/2004 of the European Parliament and the Council of 10 March 2004 on the interoperability of the European Air Traffic Management network (the interoperability Regulation) The indicated products comply with the regulations of the directives. This is proved by the compliance with the following standards: Reference number IEC 61000-6-2: 2005 IEC 61000-6-3: 2006 IEC 61010-1: 2001 Specification Electromagnetic compatibility Immunity for industrial environment Electromagnetic compatibility Emission standard for residential, commercial and light industrial environments Safety requirements for electrical equipment for measurement, control and laboratory use. Part 1: General requirements Place: Göttingen Date: 26.06.2008 This declaration certificates the compliance with the mentioned directives, however does not include any warranty of characteristics. Please pay attention to the security advises of the provided instructions for use. 7-8 021570/04/08

ADOLF THIES GmbH & Co. KG Hauptstraße 76 37083 Göttingen Germany P.O. Box 3536 + 3541 37025 Göttingen Phone ++551 79001-0 Fax ++551 79001-65 www.thiesclima.com info@thiesclima.com - Alterations reserved - 8-8 021570/04/08