OPERATING MANUAL PROGRAMMABLE DPM. Size: 48 x 96 Size: 96 x 96

Similar documents
OPERATING MANUAL Rish Eine. Size: 48 x 96 Size: 96 x 96

Programmable DPM RISH EINE

Application: Salient Features: Products Features:

RS Pro ENGLISH. Datasheet

Jewell DPM EINE BEST IN CLASS

Alpha 50. Technical Data Sheet. Special Features

RS Pro ENGLISH. Datasheet

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

AMIK 200 / 201 Technical Data Sheet

Data Sheet. RISH Master Record %THD

Data Sheet. Earth Leakage Relay RISH ELR/ELR+/ELR VI/ELR VI(NE) A V RISH ELR VI. Record. Digital Protection Relay RESET TEST ENTER

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

AMIK Three Phase Digital Panel Meters

Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

RISH ELR Earth Leakage Relay Preliminary Datasheet True RMS Measurement Trip relay cum DPM CBCT Open Detection 4 digit 7 segment LED display

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

Technical Datasheet. True RMS Digital Protection Relay. Voltage Protection Relay

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

Digital Multifunction Instrument - Rish Master 3440

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Relay. Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

RISH Delta Energy / Demand (Multifunction instrument) Data Sheet

Technical Data Sheet AMIK 300 / 301

Technical Data Sheet

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Technical Data Sheet. x1000. kwh R Y B

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

Application: Product Features: On site programmable PT/CT ratios: User selectable CT Secondary 5A/1A. User selectable PT Secondary

SUBJECT TO CHANGE WITHOUT NOTICE

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

ZIEGLER PRO-P Power / Phase Angle / Power Factor Transducer

Integra 1560 and 1580 Digital Transducer Systems

GIMA Multi-Function Electricity Meter OPERATOR S MANUAL

Operating Manual RISH EM 1320/30/ _Rev. C - 9/2014

POWER SERIES Plus. Volt / Amp / Hertz. Digital Switchboard Meter. User s Manual IM2493VAF-3

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

EA3012 TRANSCONDUCTANCE AMPLIFIER OPERATION MANUAL

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

51-54 Series II. Thermometer

PKT 512A-RO High Impedance Passive Cable Divider

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

USER S MANUAL EMPOWER POWER METER TRINITY. Empower Operational Manual

36 AC/DC True RMS. Clamp Meter. P Read First: Safety Information

Theta 20A / 20V. Technical Data Sheet. Special Features

SULTANATE OF OMAN METERING AND DATA EXCHANGE CODE

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

PRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

BDD-UM 3023 Digital Display

HAWK5000 Operators Manual

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

Installation and Operating Instructions

MultiCube Multi-Function Electricity Meter. Installation and Operation

Smart-UPS On-Line Isolation and Step-Down Transformer SRT5KTF

MODEL 8080PR3 Released on 11th Mar 2013

Phase-sequence Phase-loss Relay

Addendum to Instructions for Installation, Operation and Maintenance of Digitrip 3000 Protective Relays

Ziegler EM 1320/30/40

Computer-14d - xx - 144a

INSTRUCTION MANUAL LM192 LIGHT METER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING CONTENTS. Precautions 1. SAFETY INFORMATION

Operating instructions Fail-safe delay timer AZS About this document. Content

DM-45 Digital Multimeter

Opus 21 s80 Integrated Amplifier Owner's Manual

Model Number Structure

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator

Instantaneous Overcurrent Relay

Installation- / Monitoring technique

USER S MANUAL VAF POWER METER TRINITY. VAF Operational Manual

N. TEST TEST DESCRIPTION

INSTRUCTION MANUAL MARTINDALE EZ150 / EZ650 SOCKET TESTER 1. INTRODUCTION. ELECTRIC Trusted by professionals

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

Preset counters, electronic

Oberebenestrasse Bremgarten Switzerland Tel Fax

User s Guide. 400A AC/DC Clamp Meter. Model MA220

MHz FUNCTION GENERATOR INSTRUCTION MANUAL

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

PHV RO High Voltage Passive Probe. Instruction Manual

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

USER'S MANUAL TIS 859, TIS 849 & TIS 839 Voltage Tester

XP2-R Power and Reverse Power Relay

INSTRUCTION MANUAL. MODEL: Vintage 60R. Vintage Series Guitar Amplifi er

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

ENCORE 300 SERIES INSTALLATION AND OPERATING INSTRUCTIONS

712B. Users Manual. RTD Calibrator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Taurus CP-300 Single Pump

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

BATTERY SENSOR. User Manual. Manual Version: BMS

Application and Commissioning Manual for Numerical Over & Under Voltage Protection Relays Type MVT181 CONTENTS PAGE APPLICATION 2-7 INSTALLATION 8-16

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.

TETRIS 1000 High Impedance Active Probe. Instruction Manual

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

Transcription:

PERTING MNU PRGRMMBE PM Size: 48 x 96 Size: 96 x 96 15001059 Rev_G 10/2013

2

Section Eine PRGRMMBE PM C Volt Meter (3 Φ) : Eine - 3V C mmeter (3 Φ) : Eine - 3 C Volt Meter (1 Φ) : Eine - V C mmeter (1 Φ) : Eine - Installation & perating Instructions Contents 1. Introduction 2. Measurement Reading Screens 3. Programming 3.1 Set Up Screens 3.1.1 System Type 3.1.2 Potential Transformer Primary value 3.1.3 Current Transformer Primary value 3.1.4 uto Scrolling 4. Installation 4.1 EMC Installation Requirements 4.2 Case imensions and Panel Cut-out 4.3 Wiring 4.4 uxiliary Supply 4.5 Fusing 4.6 Earth / Ground Connections 5. Connection iagrams 5.1 Connection iagrams for EINE 96 x 96 PM 5.2 Connection iagrams for EINE 48 x 96 PM 6. Specifications 3

vailable Models : 1. Eine 3V 2. Eine 3 3. Eine V V V V 4. Eine V 1. Introduction The Eine Series is a panel mounted 96 x 96mm & 48 x 96mm igital Panel Meters for the measurement of C Voltage and current in three phase or single phase systems. The instrument integrates accurate measurement technology. The parameters are displayed with Ultra high brightness E display with 14mm igit height. Programmable PM can be configured and Programmed at site for the following : PT Primary, CT Primary. The front panel has two push buttons for userinterface to scroll through the available parameters the two keys has function as follow: 1. : Scrolls through parameter in upward sequence. isplay sequence Eine 3V : voltage, voltage, voltage, - voltage, - voltage, - Voltage, System voltage and back V to voltage. isplay sequence Eine 3 : current, current current, System current and back to current. 2. V : Scrolls the parameters in Reverse of above sequence. These PMs come with 14mm height 7 segment isplay, which enables to take readings from long distance. 4

TBE 1: Parameters isplayed with Eine 3V model TBE 2: Parameters isplayed with EINE 3 models Measured Parameters Unit of measurement Measured Parameters Unit of measurement Voltage volt Current mpere Voltage volt Current mpere Voltage volt Current mpere - Voltage volt System Current mpere - Voltage volt 3- Voltage volt System Voltage volt 2. Measurement Reading Screen In normal operation the user is presented with the measurement reading screens. These screens may be scrolled through one at a time in incremental order by pressing the key and in decrementing order by pressing key.. isplay Screens of Eine 3V Models : Screen 1 : Voltage Screen 2 : System Voltage (value displayed after Sys flashing on isplay) V V 5

B. Screens of EINE 3 Models : Screen 1 : Current Screen 2 : System Current (Value displayed after Sys flashing on isplay) V V 3. Programming The following sections comprise step by step procedures for configuring the EINE 3/ and EINE 3V/V for individual user requirements. To access the set-up screens press and hold the and Keys Simultaneously. This will take the User into the Sys Type Screen (in case of Eine-3/3V) Followed by Sys on isplay (Section 3.1) or directly into the CT/PT Primary Screen (in case of Eine- / V respectively). 3.1 Set Up Screens 3. 1. 1. System type(for EINE 3V & EINE 3) V This screen is used to set the system type. System type 3 for 3 phase 3 wire & 4 for 3 phase 4 wire system. Pressing the down key accepts the present value and advances to the PT primary (in case of Eine-3V) or CT primary (in case of Eine - 3) value Edit menu (see section 3.1.2 for PT primary and 3.1.3. for CT primary). Pressing the up key the system type edit mode and scroll the values through will enter values available. Pressing the down key advances to the system type confirmation menu. 6

System Type Confirmation This screen will only appear following the edit of system type. If system type is to be edit again, Pressing the up key will scroll between 3 for 3 phase 3 Wire and 4 for 3 Phase 4 Wire. V Pressing the down key sets the displayed value and will advance to Potential Transformer Primary Value Edit menu. (See section 3.1.2 for Eine 3V & Eine V) and current transformer primary value for Eine 3 (see section 3.1.3) 3. 1. 2. Potential Transformer Primary Value (for Eine 3V & Eine V) This screen displays PtPr message followed by previously set PT primary value on display. For Eine 3V (3 phase) user can set PT primary value from 100V to 999kV & for Eine V (single phase), user can set PT primary from nominal input voltage(vn) of meter to 999 kvn. Pressing the key accepts the present value and advances to the uto scrolling or Fixed screen selection menu. (See Section 3.1.4 for Eine-3V) for V advances to measurement screen V Pressing the key will enter the Potential transformer Primary Value Multiplier Selection. For Eine-3V: Initially the multiplier must be selected. Pressing the Key will move the decimal point position to the right Side and show # # #., after which it will again Shift to #.# #, # #.#, # # #. with nnunciation of x1000, which indicates the value in kv. Eine-V: Initially the multiplier must be selected. Pressing the Key will move the decimal Point position to the right Side and show # #.# #, # # #.# after which it will again shift to #.# # #, # #.# #, # # #.# With annunciation of x1000, which indicates the value in kv. Pressing the key accepts the present multiplier (ecimal Point position) and advances to the Potential Transformer value Edit menu with decimal flashing to indicate cursor position. Potential Transformer value Edit Pressing the key will scroll the value of the most significant digit. Pressing the key accepts the present value at the cursor position and advances the cursor to the next ess significant digit. When the least significant digit has been set, 7

V pressing the key will advance to the Potential transformer Primary Value Confirmation screen. For Eine-3 V: when PT primary is set < 100V then meter shows Err & again goes to PT primary edit stage with the minimum PT primary value i.e. 100V Eine-V: When PT primary is set less than Nominal input voltage Value of meter, then meter shows Err & again goes to PT primary edit stage with the minimum PT primary value i.e. Nominal input voltage value of that meter. Note : the flashing decimal point indicates the cursor position, a steady decimal point will be present to identify the scaling of the number until the cursor position coincides with the steady decimal point position. t this stage the decimal point will be flashing. Potential Transformer Primary Value Confirmation This screen will only appear following an edit of the Potential Transformer Primary Value If the set value is to be corrected, V pressing the key will return to the Potential Transformer Primary Value Edit stage. Pressing the key sets the value and then advance to the uto scrolling or fixed screen Selection menu. (See section 3.1.4. for Eine-3V) for Eine-V it will advances to measurement screen. 3. 1. 3 Current Transformer Primary Value (for Eine-3 & Eine-) This screen displays CtPr message followed by previously set CT primary value on display. This screen enables user to set CT primary from Nominal input current of meter to 999k. Pressing the key accepts the present value and advances to the uto Scrolling or Fixed Screen Selectlion menu. (See Section 3.1.4 for Eine-3) for Eine- it will advances to measurement screen. Pressing the key will shift decimal V point position to right s ide and show #.# #, # #.#, # # #., after which it It will again shift to #. # #, # #.#, # # #. with nnunciation of x1000,. It indicates the value in k. Pressing the key accepts the decimal point position and enters into Current Transformer Primary value edit. 8

Current Transformer Primary value Edit Pressing the key will scroll the value of the most significant digit. Pressing the key accepts the present value at the cursor V position and advances the cursor to the next ess significant digit. When the least significant digit has been set, pressing the key will advance to the Current transformer Primary Value confirmation screen. When CT primary is set less than Nominal input current value of meter, then meter shows Err and again goes to CT primary edit state with minimum CT primary value i.e Nominal input current value of meter. Note : the flashing decimal point indicates the cursor position, a steady decimal point will be present to identify the scaling of the number until the cursor position coincides with the steady decimal point position. t this stage the decimal point will be flashing. Current Transformer Primary Value Confirmation This screen will only appear following an edit of the Current Transformer Primary Value. If the set value is to be corrected, pressing the key will V return to the Current Transformer Primary Value Edit stage. Pressing the key sets the value and then advance to the uto Scrolling or Fixed screen Selection menu for Eine-3. (See section 3.1.4) for Eine- it will exit from setup and goes to measurement reading screen. 3.1.4 Selection of uto Scrolling or fixed Screen (only for Eine-3V/Eine-3) V Pressing the key will accept the display value and exit from set up and enter into measurement mode. Pressing the key will scroll between Yes and No. Select Yes for uto scrolling of parameter display and Select No for fixed display screen. Pressing the key will enter into Screen selection Confirmation screen. 9

V uto / Fixed Screen Confirmation Pressing the key set the selected option and Exit set up with entering into measurement mode. Pressing the key re-enter Screen selection menu. 4. Installation Mounting of EINE is featured with easy Clip- in mounting (only for 96 x 96 model). Push the meter in panel solt (size 92 x92 mm), it will click fit into panel with the four integral retention clips on two sides of meter. If required dditional support is provided with swivel screws (optional) as shown in figure. Easy Clip - in mounting s the front of the enclosure conforms to IP 50. additional protection to the panel may be obtained by the use of an optional panel gasket. The terminals at the rear of the product should be protected from liquids. The EINE V/ should be mounted in a reasonably stable ambient temperature and where the operating 0 temperature is within the range 0 to 50 C. Vibration Swivel screw should be kept to a minimum and the product should not be mounted where it will be subjected to excessive direct sunlight. Caution 1. In the interest of safety and functionality this product must be installed by a qualified engineer, abiding by any local regulations. 2. Voltages dangerous to human life are present at some of the terminal connections of this unit. Ensure that all supplies are de-energised before attempting any connection disconnection. 3. These products do not have internal fuses therefore external fuses must be used to ensure safety under fault conditions. 10

96mm 9 2 m m +0. 8 4.1 EMC Installation Requirements This product has been designed to meet the certification of the EU directives when installed to a good code of practice for EMC in industrial environments, e.g. 1. Screened output and low signal input leads or have provision for fitting RF suppression components, such as ferrite absorbers, line filters etc., in the event that RF fields cause problems. Note: It is good practice to install sensitive electronic instruments that are performing critical functions, in EMC enclosures that protect against electrical interference which could cause a disturbance in function. 2. void routing leads alongside cables and products that are, or could be, a source of interference. 3. 4. To protect the product against permanent damage, surge transients must be limited to 2kV pk. It is good EMC practice to suppress differential surges to 2kV at the source. The unit has been designed to automatically recover in the event of a high level of transients. In extreme circumstances it may be necessary to temporarily disconnect the auxiliary supply for a period of greater than 5 seconds to restore correct operation. ES precautions must be taken at all times when handling this product. 4.2 Case imensions and Panel Cut ut 4.2.1 for 96X96 models 96 mm 27 mm 92mm+0.8 Front isplay rea 6 mm 11 Panel Cutout 35 mm MX PNE THICKNESS 0.18,5mm

4.2.2 for 48X96 models Mounting Position Installation Cutout 4.3 Wiring Input connections are made directly to screw-type terminals for 96 x 96mm PM and Plugable connector type for 48 x 96mm PM. Numbering is clearly marked on the connector. Choice of cable should meet local regulations. Terminal for inputs will accept wire up to 2 2 4mm (12 WG) or 2.5mm (12WG)Standard Note : 1) It is recommended to use wire with lug for connection with meter. 2) For disconnecting the device a switch or circuit-breaker shall be included at the site and shall be within easy reach of the operator. The specification are as below. For aux. = t least 1.5 times of applied Power supply. For Measuring Input = t least 1.5 times of applied measuring inputs. 4.4 uxiliary Supply EINE should ideally be powered from a dedicated supply, however it may be powered from the signal source, provided the source remains within the limits of the chosen auxiliary voltage. 4.5 Fusing It is recommended that all voltage lines are fitted with 1 amp HRC fuse. 4.6 Earth/Ground Connections For safety reasons, panels and accesoriess should be grounded in accordance 12

5. Connection iagrams 5.1 For 96x96 PM Connections For EINE V 96 x 96mm Connections For EINE 96 x 96mm 1 2 13 14 1 2 13 14 N UX SUPPY SINGE PHSE 2-WIRE IGIT PNE METER (External ux.) UX SUPPY N SINGE PHSE 2-WIRE IGIT PNE METER (External ux.) Connections for EINE 3V 96 x 96mm 1 2 3 4 13 14 1 2 3 4 13 14 N UX SUPPY 3-PHSE 4-WIRE UNBNCE IGIT METERING SYSTEM (WITH EXTERN UX.) NC UX SUPPY 3-PHSE 3-WIRE UNBNCE IGIT METERING SYSTEM (WITH EXTERN UX.) 13

Connections for EINE 3 96 x 96mm 1 2 3 4 5 6 13 14 1 2 5 6 13 14 N UX SUPPY 3-PHSE 4-WIRE UNBNCE IGIT PNE METER (External ux.) UX SUPPY 3-PHSE 3-WIRE UNBNCE IGIT PNE METER (External ux.) 5.2 For 48x96 PM Connections for EINE 3V 48 x 96mm 8 6 3 1 B 8 6 3 B N UX SUPPY 3-PHSE 4-WIRE UNBNCE IGIT METERING SYSTEM (WITH EXTERN UX.) UX SUPPY 3-PHSE 3-WIRE UNBNCE IGIT METERING SYSTEM (WITH EXTERN UX.) 14

Connections for EINE 3 48 x 96mm 1 3 6 7 9 10 B 1 3 9 10 B UX SUPPY 3-PHSE 4-WIRE UNBNCE IGIT PNE METER (External ux.) UX SUPPY 3-PHSE 3-WIRE UNBNCE IGIT PNE METER (External ux.) Connections For EINE V 48 x 96mm Connections For EINE 48 x 96mm 1 3 B 1 3 B N UX SUPPY SINGE PHSE 2-WIRE IGIT PNE METER (External ux.) N UX SUPPY SINGE PHSE 2-WIRE IGIT PNE METER (External ux.) 15

6. Specifications : Input voltage (Eine-3V / Eine-V) : Nominal Input Voltage Ranges ine - Neutral ine - ine 57 V - 70 V -N 100 V - 120 V - 71 V - 139 V -N 121 V - 240 V - 140 V - 277 V -N 241 V - 480 V - 600 V -N (pplicable for single phase only) Max continuous input voltage 120% of rated value Nominal input voltage burden <0.3V approx. per phase System PT Primary values Eine-3 V: 100V- to 999kV - Programmable onsite Eine-V: 60V-N to 999kV -N Programmable onsite Input current (Eine-3 / Eine-) : Nominal Input Current Ranges 1 or 5 C System CT Primary values 1 to 999k(for 1 or 5) Programmable onsite Max continuous input current 120% of rated value (optional : 150% of rated value) Nominal input current burden <0.3V approx. per phase verload Indication : -o- For continuous input current 120% (If input is greater than 125% of secondary value) For continuous input current 150% (If input is greater than 155% of secondary value) uxiliary Supply : C-C uxiliary Supply 40V to 300V C/C (+/- 5%) C uxiliary Supply 80V to 300V C Frequency Range for C ux. Supply 45 to 65 Hz V Burden <3 V at 240V,50Hz. 16

verload Withstand : Voltage 2 X Rated Value for 1 Second, repeated 10 times at 10 second interval. Current 4 X Rated Value for 1 Second, repeated 5 times at 5 min interval. perating Measuring Ranges Voltage Range 10... 120 % of Rated Value Current Range 10... 120 % of Rated Value (ptional: 10... 150 % of Rated Value) Frequency 45... 65 Hz Reference conditions for ccuracy : 0 0 Reference temperature 23 C + 2 C Input waveform Sinusoidal (distortion factor 0.005) uxiliary supply voltage Rated Value + 1 % uxiliary supply frequency Rated Value + 1 % Input Frequency 50 Hz / 60 Hz Voltage Range 20...100% of Nominal Value Current Range 10...100% of Nominal Value ccuracy Voltage (Eine-3V / Eine-V) + 1.0% (0.5% on request) of Nominal value. Current (Eine-3 / Eine-) + 1.0% (0.5% on request) of Nominal value. Measurement error is normally much less than errors specified in the above. Variation due to influence quantity is less than twice the error allowed for reference condition. 17

Temperature Coefficient Voltage Current 0 (For Rated value range of use 0... 50 C ) isplay E igit height nnunciator Es Controls User Interface pplicable Standards EMC Safety IP for water & dust Safety Pollution egree Installation Category High Voltage Test 0 0.025% / C 0 0.05% / C 1 line 4 digits. 14mm For isplaying Units and Parameter 2 Keys IEC 61326-1:2005 10V/m min-evel 3 industrial low level Electromagnetic radiation environment IEC 61010-1: 2001,Permantly Connected use IEC 60529 2 III 2.2 kv C, 50 Hz for 1 minute 18

Environmental conditions perating temperature 0 0 to 50 C Storage temperature -25 to 70 C Relative humidity 0.. 90 % (Non condensing) Warm up time Minimum 3 minute Shock 15g in 3 planes Vibration 10.. 55 Hz, 0.15mm amplitude Enclosure Front IP50 Back IP20 Material Polycarbonate Housing, Terminals Screw-type terminals imension and weight: 96x96 models Bezel Size (IN 43718) 96mm X 96mm (IN 43718 ) Panel Cut-ut 92 + 0.8mm X 92 + 0.8mm verall epth 40mm Weight 310g pprox. 48x96 models 48mm X 96mm 43.5 + 0.6mm X 92 + 0.8mm 68mm 250g pprox. The Information contained in these installation instructions is for use only by installers trained to make electrical power installations and is intended to describe the correct method of installation for this product. However, Manufacturer has no control over the field condition which influence product installation. It is the user's responsibility to determine the suitability of the installation method in the user's field conditions. Manufacturer only obligations are those in Manufacturer standard Conditions of Sale for this product and in no case will Manufacturer be liable for any other Incidental, indirect or consequential damages arising from the use or misuse of the products. 19

WRRNTY ear Customer, You are now the privileged owner of PM, a product that ranks the first of its kind in the world. Company provides 12 months warranty from the original date of Purchase against defective material and workmanship. In the unlikely event of failure of the instrument / accessories within the warranty period. Company will repair meter / accessories free of charge. Please hand over the meter / accessories to the dealer / stockist from whom you have purchased along with this card and relevant Cash Memo / Invoice. This warranty entitles you to bring the meter / accessories at your cost to the nearest stockist / dealer and collect it after repairs. N TRNSPRTTIN CHRGES WI BE REIMBURSE. The warranty is not valid in following cases: 1. Warranty card duly signed and stamped and original Cash Memo / Invoice is not sent along with PM. 2. Complete warranty card is not presented to authorised person at the time of repairs. 3. Meter / accessories is not used as per the instructions in the instruction manual. 4. efect caused by misuse, negligence, accidents, tampering and cts of God. 5. Improper repairing by any person not authorised by the company. 6. ny sort of Modification, lteration of any sort is made in electrical circuitry. 7. Seal provided inside/outside is broken. In case of dispute to the validity of the warranty, the decision of Company service center will be final. If you bought this PM directly from the company, and if you notice transit damage, then you must obtain the insurance surveyors report and forward it to Company. Thank you. (To be filled by authorized dealer) Model No.: Serial No. : ate of Purchase : Cash Memo / Invoice No. : ealer s Signature : ealer s Stamp :