Frequency Response Initiative Industry Advisory Generator Governor Frequency Response

Similar documents
NARUC. Summer Committee Meetings. Staff Subcommittees on Electricity & Electric Reliability

Robert W. Cummings - NERC Director of System Analysis and Reliability Initiatives William Herbsleb - Chairman of Frequency Response Standard Drafting

Demonstration of PFR Improvement September ERCOT Operations Planning

Harmonizing the Changing Resource Mix Keeping the Grid Together

Frequency Response Characteristic Survey Training Document

Table of Contents Error! Bookmark not defined.

Frequency Response Standard Background Document November, 2012

Lessons Learned in Model Validation for NERC Compliance

Using Synchrophasors for Frequency Response Analysis in the Western Interconnection. Bonneville Power Administration -- WECC JSIS Chair

Minutes Frequency Response Initiative Meeting

NERC Training Document Understand and Calculate Frequency Response

generation greater than 75 MVA (gross aggregate nameplate rating) Generation in the ERCOT Interconnection with the following characteristics:

Reliability Guideline: Generating Unit Operations During Complete Loss of Communications

Reliability Guideline: Generating Unit Operations During Complete Loss of Communications

11/4/2013. NERC RS Meeting October 28, 2013 Sullivan s Island, SC. Troy Blalock SERC NERC RS Representative

Forward Looking Frequency Trends Technical Brief ERS Framework 1 Measures 1, 2, and 4: Forward Looking Frequency Analysis

Market mechanisms for frequency control

UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION

Keeping it up to Speed Off-Nominal Frequency Operations. CETAC 2018 San Ramon

Lessons Learned in Model Validation for NERC Compliance

Knowledge-based Adaptive Frequency Control of Gas Turbine Generator Model for Multi-machine Power System

NPCC Regional Reliability Reference Directory # 12. Underfrequency Load Shedding Program Requirements

Frequency Response Standard Whitepaper

Informational Filing, Frequency Response Annual Analysis Docket No. RM

AORC Technical meeting 2014

Industry Webinar. Reactive Power Planning. NERC System Analysis and Modeling Subcommittee (SAMS) March 2017

Recently, the SS38 Working Group on Inter-Area Dynamic Analysis completed two study reports on behalf of the UFLS Regional Standard Drafting Team.

MARKET ANCILLARY SERVICE SPECIFICATION

Frequency Response Initiative Report

Procedure for ERO Support of Frequency Response and Frequency Bias Setting Standard. Event Selection Process

EH2741 Communication and Control in Electric Power Systems Lecture 2

Post-Event Analysis of a Compound Event in the ERCOT System Using Synchrophasor Data

TESTING GUIDANCE FOR PROVIDERS OF FIRM FREQUENCY RESPONSE BALANCING SERVICE

Table of Contents. NERC 2016 Frequency Response Annual Analysis September 2016 ii

EE 742 Power System Components. Y. Baghzouz ECE Department UNLV

Attachment B to Primary Frequency Response Reference Document Sustained Primary Frequency Response Methodology for BAL-001-TRE-1

Real-time Monitoring of Power Oscillations and Modal Damping in the European ENTSO-E System

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Wind Aggregated Generating Facilities Technical Requirements

Generation and Load Interconnection Standard

2015 Frequency Response Annual Analysis

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements

1200 MW Fault Induced Solar Photovoltaic Resource Interruption Disturbance Report

EE 742 Chapter 9: Frequency Stability and Control. Fall 2011

CHAPTER 1 INTRODUCTION

Generation and Load Interconnection Standard

Endorsed Assignments from ERS Framework

Lecture 15 EMS Application II Automatic Generation Contol. Davood Babazadeh

2018 Frequency Response Annual Analysis

UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION

Proposed Language in BAL-003-1/Comments New Standard or Other Action R1. Each Balancing Authority shall This. Attachment A.

Texas Reliability Entity Event Analysis. Event: May 8, 2011 Loss of Multiple Elements Category 1a Event

Deleted: 9 4 anuary ... [1] Deleted: much more. Formatted ... [2] Formatted Table. Formatted: Indent: Left: 0.06 cm

Step-Response Tests of a Unit at Atatürk Hydro Power Plant and Investigation of the Simple Representation of Unit Control System

System Protection and Control Subcommittee

VOLTAGE STABILITY OF THE NORDIC TEST SYSTEM

Study of Frequency Response in Power System with Renewable Generation and Energy Storage

Indication of Dynamic Model Validation Process

NERC Protection Coordination Webinar Series June 23, Phil Tatro

AUTOMATIC VOLTAGE REGULATOR AND AUTOMATIC LOAD FREQUENCY CONTROL IN TWO-AREA POWER SYSTEM

OPERATING CODE NO. 5 (OC5)

IEEE Major Revision of Interconnection Standard

Standard BAL Frequency Response and Frequency Bias Setting

TECHNICAL SPECIFICATIONS AND OPERATING PROTOCOLS AND PROCEDURES FOR INTERCONNECTION OF LARGE GENERATION FACILITIES. Document 9020

Document C-29. Procedures for System Modeling: Data Requirements & Facility Ratings. January 5 th, 2016 TFSS Revisions Clean Open Process Posting

PJM Regulation Study Update

Forced Oscillation Event Analysis

TESTING GUIDANCE FOR PROVIDERS OF ENHANCED FREQUENCY RESPONSE BALANCING SERVICE

Agenda Item 3h Attachment 9

INITIAL RfG FREQUENCY PARAMETER SELECTION. BASED ON DRAFT RfG VALUES. Requirement Range Suggested GB Value Comments

Simulation of Synchronous Machine in Stability Study for Power System: Garri Station as a Case Study

Alberta Reliability Standard Frequency Response and Frequency Bias Setting BAL-003-AB-1.1

A New Approach Applied to Adaptive Centralized Load Shedding Scheme

LOAD FREQUENCY CONTROL FOR A TWO-AREA INTERCONNECTED POWER SYSTEM BY USING SLIDING MODE CONTROLLER

BPS-Connected Inverter-Based Resource Performance

Performance Analysis of PSO Optimized Fuzzy PI/PID Controller for a Interconnected Power System

BAL Standard Project Frequency Response and Frequency Bias Setting Industry Webinar

Integration of Variable Renewable Energy

Automatic Generation control of interconnected hydrothermal power plant Using classical and soft computing Technique

Informational Filing Regarding 2017 Frequency Response Annual Analysis Report Docket No. RM

GUIDELINES FOR UTILIZATION OF FREQUENCY AND TIME ERROR DEVICES AND CALIBRATING TIE LINE SIGNAL

NORTH CAROLINA INTERCONNECTION REQUEST. Utility: Designated Contact Person: Address: Telephone Number: Address:

Comparative Analysis Between Fuzzy and PID Control for Load Frequency Controlled Power

Standard Development Timeline

Standard BAL b Automatic Generation Control

Load-Frequency Control Service in a Deregulated Environment

Reducing the Effects of Short Circuit Faults on Sensitive Loads in Distribution Systems

Under-Frequency Load Shedding based on PMU Estimates of Frequency and ROCOF

Wide-Area Measurements to Improve System Models and System Operation

Grid codes and wind farm interconnections CNY Engineering Expo. Syracuse, NY November 13, 2017

Standard PRC Generator Frequency and Voltage Protective Relay Settings. A. Introduction. See the Implementation Plan for PRC

Authors and affiliations. Introduction. Approach

DEVELOPMENT OF SMART UNDERFREQUENCY LOAD SHEDDING SYSTEM

Reference Document Balancing Authority Area Footprint Change Tasks

Standard MOD Verification of Models and Data for Generator Excitation Control System or Plant Volt/Var Control Functions

A Topology-based Scheme for Adaptive Underfrequency Load Shedding

Transmission Interconnection Requirements for Inverter-Based Generation

Informational Filing, Frequency Response Annual Analysis Docket No. RM

ESB National Grid Transmission Planning Criteria

Geoff Brown & Associates Ltd

Advantages and Disadvantages of EHV Automatic Reclosing

Transcription:

Frequency Response Initiative Industry Advisory Generator Governor Frequency Response Troy Blalock South Carolina Electric and Gas Bob Cummings NERC Reliability Initiatives and System Analysis Rich Bauer NERC Reliability Risk Management April 7, 2015

Agenda Why Primary Frequency Response is important Define Primary Frequency Response Discuss the NERC Advisory Generator Governor Frequency Recommendations for Dead Band and Droop Coordination Requirement with Plant DCS Step vs. Linear Response Frequent Occurring Issues Questions 2

Why Primary Frequency Response Is Important Essential for Reliability of the Interconnections Cornerstone for system stability Line of defense to prevent Under Frequency Load Shedding(UFLS) Prevent equipment damage Essential for System Restoration Droop response is critical in restoration efforts Compliance with NERC Standards BAL-003-1, BAL-001 prevent future regulations related to generator frequency response performance To accurately predict system events ( Transmission Models) 3

Frequency 4

Primary Frequency Response Primary Frequency Response are actions to arrest and stabilize frequency in response to frequency deviations. Primary Response comes from generator governor response, load response (motors) and other devices that provide immediate response based on local (device- level) control. Generator Governor Response within 0-10 seconds.. Frequency Point A is the frequency prior to the event Frequency Point C is the nadir or lowest point Frequency Point B is the settling frequency 5

Classic Frequency Excursion Recovery 6

Primary Frequency Response Generator Response Generator turbine governors either mechanically or electronically control the primary control valves to the turbine. Steam, Water or Fuel is what is regulated. Graphic from GE info bulletin PSIB20150212 7

Current Interconnection Profiles 8

Current Interconnection Profiles 9

MW / 0.1 Hz Decline in Eastern Interconnection Frequency Response Eastern Interconnection Mean Primary Frequency Response 4,000 3,500 Source 1994-2009: J. Ingleson & E. Allen, "Tracking the Eastern Interconnection Frequency Governing Characteristic" presented at 2010 IEEE PES. Source 2010-2011: Daily Automated Reliability Reports * 1999 Data Interpolated * 3,000 2,500 2,000 1,500 1,000 500 10 Year

Current Eastern Interconnection Frequency Response 11

Generator Governor Frequency Response Advisory Advisory issued February 5th Prompted by NERC Resource Subcommittee Interconnections frequency response has declined Eastern Interconnection Lazy L profile 2010 and 2013 Generator Survey Data Generator Governor Frequency Response Advisory 12

What Has Been Learned Primary Frequency Response logic typically resides in the turbine controls. Dead Bands Vary Many exceed 36 mhz or 2.16 RPM Droops Settings Vary Majority Droops reported 5% Graphic from GE info bulletin PSIB20150212 13

What Has Been Learned Coordination with plant DCS is a requirement when operating in MW Set Point Coordinated Control. 14 Graphic from GE info bulletin PSIB20150212

Example Frequency 60.000 Hz 400 MW 150 MW 150 MW 100 MW Graphic from GE info bulletin PSIB20150212 15

Missing Example Frequency 59.940 Hz 400 MW 153 MW for little more than 1 second +/- Dead Band MW 153 MW for little more than 1 second 100 MW Graphic from GE info bulletin PSIB20150212 16

Example Frequency 59.940 Hz 6 MW 400 MW 153 MW 406 MW +/- Dead Band MW 153 MW 100 MW Graphic from GE info bulletin PSIB20150212 17

Example Frequency 60.000 Hz 0 MW 400 MW 150 MW 400 MW 150 MW 100 MW Graphic from GE info bulletin PSIB20150212 18

Tale of Two Tales No Frequency Algorithm in DCS 3-175 MW GE7FA Gas Mark VIe Turbine 3/3/2015 Frequency Algorithm in Plant DCS 19

The Code OR MW Pr imarycontrol HZactual 60 DB 60* Droop DB *( Frequency Re sponsivecapacity )*( 1) 20

Frequency 59.940 Hz Conventional Steam Plant 6 MW 400 MW 406 MW +/- Dead Band MW 21 Graphic from GE info bulletin PSIB20150212 406 MW

Droop Response Step vs. Linear or Proportional Source: Frequency Response Initiative Report: The Reliability Role of Frequency Response, NERC, Robert Cummings, October 30, 2012 22

Droop - Linear Response Source: Frequency Response Initiative Report: The Reliability Role of Frequency Response, NERC, Robert Cummings, October 30, 2012 23

Event Occurrence The majority of the Eastern events where frequency declines in excess of 36 mhz is when the interconnections are lightly loaded and the majority of generation is dispatch is less than Pmax. Source: MYBA_2015_FRS_FORM_19a_Eastern Interconnection_Final 24

Common Generator Frequency Response Issues Combustion Turbine Conventional Steam Unit Other issues Some units come out of AGC or MW Set Point Control when frequency response is being provided. Conventional Steam Turbines operating in sliding pressure or turbine following mode Resolution/quality of speed signal 25

A Misconception If I provide primary frequency response I will be penalized. Interconnection frequency events resulting in deviations below the recommended governor deadband settings are infrequent (about 1 / week) Primary frequency response is a relatively small amount of energy for a short period Typically provided for about 120 seconds Roughly 0.5% of capacity Tariff provisions vary but typically measure dispatch imbalance or deviation charges based on substantially longer time intervals (on the order of 30 to 60 minutes with a tolerance band of 5-10%) Tariff provisions typically allow for exemptions or recourse if a generating resource is subject to imbalance or deviation charges due to providing frequency response Contact your Transmission Provider for specific tariff information 26

Requested Next Steps Fall Outages 2015/ Spring 2016 Check and add if necessary Frequency Response Algorithm on Frame Gas Turbines Check/ Adjust Dead Bands and Droops Check Conventional Steam Unit Note: Need to make sure dead bands and droop are coordinated to be the same in the Plant DCS as Turbine. 27

Resources NERC Resource Subcommittee North American Generator Forum www.generatorforum.org Original Equipment Manufacturers Industry Trade Associations Architect /Engineering Firms Balancing Authority 28

Participating Vendors * - have developed or are developing a related technical guide 29

30

Appendix Sample Logic for GT 31