Flex-Axiom. Nanosurf. The Most Versatile AFM System for Materials Research

Similar documents
Flex-Bio. Nanosurf. Versatile Research AFM System for Life Science

Flex-Bio Versatile Research AFM System for Life Science

Nanosurf easyscan 2 FlexAFM

Cutting-edge Atomic Force Microscopy techniques for large and multiple samples

INDIAN INSTITUTE OF TECHNOLOGY BOMBAY

Nanosurf Nanite. Automated AFM for Industry & Research.

Optical Microscope. Active anti-vibration table. Mechanical Head. Computer and Software. Acoustic/Electrical Shield Enclosure

Measurement of Microscopic Three-dimensional Profiles with High Accuracy and Simple Operation

SPM The Industry s Performance Leader High Resolution Closed-loop System Fast, Easy Tip & Sample Exchange Versatility and Value Powerful Research

Standard Operating Procedure of Atomic Force Microscope (Anasys afm+)

Lateral Force: F L = k L * x

Indian Institute of Technology Bombay

Nanosurf easyscan 2 Your Modular Scanning Probe Microscopy System

Microscopic Structures

Park NX20 The leading nano metrology tool for failure analysis and large sample research.

NanoFocus Inc. Next Generation Scanning Probe Technology. Tel : Fax:

Ionscope SICM. About Ionscope. Scanning Ion Conductance Microscopy. Ionscope A brand of Openiolabs Limited

easypll UHV Preamplifier Reference Manual

Figure for the aim4np Report

Outline: Introduction: What is SPM, history STM AFM Image treatment Advanced SPM techniques Applications in semiconductor research and industry

ATOMIC FORCE MICROSCOPY

Rebirth of Force Spectroscopy: Advanced Nanomechanical, Electrical, Optical, Thermal and Piezoresponse Studies

Atomic Force Microscopy (Bruker MultiMode Nanoscope IIIA)

Keysight 9500 AFM. Data Sheet

Constant Frequency / Lock-In (AM-AFM) Constant Excitation (FM-AFM) Constant Amplitude (FM-AFM)

Investigate in magnetic micro and nano structures by Magnetic Force Microscopy (MFM)

Nanoscale Material Characterization with Differential Interferometric Atomic Force Microscopy

Scanning Ion Conductance Microscope ICnano

attosnom I: Topography and Force Images NANOSCOPY APPLICATION NOTE M06 RELATED PRODUCTS G

Keysight Technologies 5500 AFM Controller Upgrade. Data Sheet

UNIVERSITY OF WATERLOO Physics 360/460 Experiment #2 ATOMIC FORCE MICROSCOPY

LOW TEMPERATURE STM/AFM

HybridStage - Automated, large sample-area mapping made easy

; A=4π(2m) 1/2 /h. exp (Fowler Nordheim Eq.) 2 const

Park XE7 The most affordable research grade AFM with flexible sample handling.

Basic methods in imaging of micro and nano structures with atomic force microscopy (AFM)

Asylum Research. MFP-3D Infinity. Endless Applications. Unlimited Potential. Performance / Versatility / Support

Park NX-Hivac The world s most accurate and easy to use high vacuum AFM for failure analysis.

Atomic Force Microscopes

Options and Accessories for Asylum Research MFP-3D AFMs

10 Things to Consider when Acquiring a Nanopositioning System

Advanced Nanoscale Metrology with AFM

- Near Field Scanning Optical Microscopy - Electrostatic Force Microscopy - Magnetic Force Microscopy

Standard Operating Procedure

Electric polarization properties of single bacteria measured with electrostatic force microscopy

Introduction of New Products

_active vibration isolation desktop unit halcyonics_i4 series

SIGNAL RECOVERY. Model 7265 DSP Lock-in Amplifier

Akiyama-Probe (A-Probe) guide

Akiyama-Probe (A-Probe) guide

Prepare Sample 3.1. Place Sample in Stage. Replace Probe (optional) Align Laser 3.2. Probe Approach 3.3. Optimize Feedback 3.4. Scan Sample 3.

attocube systems Probe Stations for Extreme Environments CRYOGENIC PROBE STATION fundamentals principles of cryogenic probe stations

MFP-3D-BIO. Asylum Research. The only full-capability AFM on an inverted optical microscope

The Most Accurate Atomic Force Microscope. Park NX20 The leading nano metrology tool for failure analysis and large sample research.

Description of options, upgrades and accessories for the laser beam stabilization system Compact

Suivie de résonance: méthodes à fréquences multiples. Romain Stomp Application Scientist, Zurich Instruments AG. ZI Applications

The Most Accurate Atomic Force Microscope. Park XE15 Power and versatility, brilliantly combined.

University of MN, Minnesota Nano Center Standard Operating Procedure

Agilent Technologies Scanning Probe Microscope. User s Guide. Agilent Technologies

M-041 M-044 Tip/Tilt Stage

Lecture 20: Optical Tools for MEMS Imaging

Manufacturing Metrology Team

3D Optical Motion Analysis of Micro Systems. Heinrich Steger, Polytec GmbH, Waldbronn

Spotlight 150 and 200 FT-IR Microscopy Systems

ezafm OPERATING MANUAL

contents TABLE OF The SECOM platform Applications - sections Applications - whole cells Features Integrated workflow Automated overlay

Principles of operation 5

General catalog. BESMAK Servo-hydraulic Medium-Capacity fatigue test System with Furnace. 1 BESMAK Material Testing Machines

Park NX10. The most accurate and easiest to use Atomic Force Microscope.

Nanosurf Easyscan 2 STM

Nanonics Systems are the Only SPMs that Allow for On-line Integration with Standard MicroRaman Geometries

PFM Experiments with High Voltage DC/AC Bias

Operating Instructions. easyscan 2 STM. Version 2.1

PICO MASTER 200. UV direct laser writer for maskless lithography

PicoMaster 100. Unprecedented finesse in creating 3D micro structures. UV direct laser writer for maskless lithography

GFT1504 4/8/10 channel Delay Generator

OPTICS IN MOTION. Introduction: Competing Technologies: 1 of 6 3/18/2012 6:27 PM.

Nano Beam Position Monitor

Compact Nanopositioning System Family with Long Travel Ranges

Park NX-Hivac: Phase-lock Loop for Frequency Modulation Non-Contact AFM

Keysight Technologies 9500 AFM. Data Sheet

Mass Spectrometry and the Modern Digitizer

GFT Channel Digital Delay Generator

nanovea.com PROFILOMETERS 3D Non Contact Metrology

SENSOR+TEST Conference SENSOR 2009 Proceedings II

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

Electronic Characterization of Materials Using Conductive AFM

multi-channel Potentiostat / Galvanostat / Impedance Analyzer Rev

Ion Beam Lithography next generation nanofabrication

Fiber Optic Device Manufacturing

P-736 PInano Z Microscope Scanner for Microtiter Plates

LVEM 25. Low Voltage Electron Microscope Fast Compact Powerful.... your way to electron microscopy

Module 5: Experimental Modal Analysis for SHM Lecture 36: Laser doppler vibrometry. The Lecture Contains: Laser Doppler Vibrometry

Instructions for easyscan Atomic Force Microscope

PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES MODEL 6500 SERIES. Programmable AC Power Source. Key Features:

Atomic Scale Patterning Made Easy

V2018 SPINSTAND AND NEW SERVO-8 SYSTEM

ESA400 Electrochemical Signal Analyzer

PIHera Piezo Linear Precision Positioner

Laser Speckle Reducer LSR-3000 Series

Transcription:

Flex-Axiom The Most Versatile AFM System for Materials Research Measurement capabilities in air and liquid Versatility in applications and Compatibility with inverted microscopes High precision scanning and data acquisition Nanosurf www.nanosurf.com swiss quality

FlexAFM Axiom Origami DNA on muscovite mica. 200 nm Lateral force microscopy on a PS-PB polymer blend. The most versatile AFM system for Materials Research For success in research, scientists depend on professional tools that can readily provide the information needed, regardless of the tasks at hand. By advancing key technologies and designs, Nanosurf has made the FlexAFM one of the most versatile and flexible atomic force microscopes ever, allowing a large variety of applications to be handled with ease. Together with the C3000 controller anything is possible. Key Features & Benefits Flat and linear scanning thanks to flexure-based scanner technology True flexibility with exchangeable cantilever holders that have been optimized for specialized tasks: Cantilever Holder Air Only: AFM measurements in air Cantilever Holder Liquid/Air: AFM measurements in air and liquid Cantilever Holder Scanning Thermal: Scanning thermal microscopy Cantilever Holder FluidFM: Fluid Force Microscopy applications More measurement versatility with the FlexAFM s scanning capabilities in liquid and its additional measurement : Lateral Force Microscopy Kelvin Probe Force Microscopy Scanning Thermal Microscopy Fluid Force Microscopy Compatible with inverted microscopes: FlexAFM Inverted Microscope Option provides a seamless integration with many types of inverted microscopes Readily combine AFM and optical data (fluorescence/phase contrast/bright field) Beyond images A true research AFM is only as powerful as its ability to acquire and combine sample measurement data from multiple techniques. This is where the FlexAFM can do plenty! In the experiment below, this is nicely demonstrated. On an inverted microscope, and in a single setup, the FlexAFM combines bright field analysis, immunofluorescent detection, AFM topography, and force mapping of the internal limiting membrane (ILM) of the human retina into state-of-the-art research towards methods for early tissue diagnostics: MFM on stainless steel. KPFM image of Graphene (blue) deposited on Copper (yellow). Crystal defects and differences in substrate coupling can be made visible. A 180 µm C 20 µm E Percentage observed 40 ILM 30 20 10 membrane edge 0 0 200 400 600 800 1000 Stiffness (kpa) B D F Force (nn) 1.0 0.8 0.6 0.4 0.2 glass substrate 180 µm glass substrate membrane edge ILM 20 µm ILM 0.0 0 50 100 150 200 250 Displacement (nm) (A) Bright field image of isolated ILM in a physiological buffer. (B) Fluorescence image of the same section showing antilaminin staining. (C) AFM topograph of a subsection of the ILM; also shown as overlay in B. (D) AFM stiffness map of the same subsection. The color for each point represents the local stiffness value as calculated from force curves recorded at the respective positions. (E) Histogram of the stiffness data shown in D. (F) Typical force displacement curves obtained on the ILM and on the glass substrate. These curves are converted to force indentation data, which then allows calculation of the stiffness. Stiffness distribution of biological tissues has been shown to be a marker for diseases such as agerelated macular degeneration, arthritis and cancer. Data: Marko Loparic, Marija Plodinec, Philip Oertle & Paul B. Henrich, Biozentrum/SNI/UHBS, University of Basel. 2

The Flex-Axiom system Flex-Axiom system inside the Acoustic Enclosure 300, with FlexAFM video camera, FlexAFM sample stage 204, I100 scan head interface and C3000 controller. The Cantilever Holder As central part of the AFM detection system, the cantilever holder contains cantilever alignment structures for exact cantilever positioning and all optics related to Nanosurf s top and side view technology. It is magnetically attached to the scanner unit to allow quick removal from the scan head for easy cleaning and fast cantilever exchange. Four cantilever holder models are currently available, each optimized for its own specific task. Alternative stages: The ATS 204 is an automated translation stage that allows movement of the sample in X, Y, and Z via the Nanosurf stage control unit and accompanying software. Additionally, it can optionally contain a highresolution 100-µm Z-actuator with position sensor that is ideally suited for force spectroscopy measurements. The ECS 204 allow to perform simultaneous AFM imaging and electrochemical measurements on electrodes and samples immersed in electrolyte solutions. It has in integrated micrometer stage and together with the electrochemical cell it allows to work in oxygen free atmosphere and can accommodate a true reference electrode, flat or rod type samples and allows for liquid exchange. Cantilever holder air only The cantilever holder air only is the default cantilever holder for any FlexAFM system. Its CantiClip spring provides a very convenient way to hold and exchange a cantilever. Top Side Cantilever holder liquid/air With its SureAlign optics, the cantilever holder liquid/air adds liquid measurement capabilities to your FlexAFM. In addition to measuring in air and in a liquid droplet (as illustrated in the images to the right) it can dive directly into a layer of liquid with up to 6 mm in height, e.g. in a standard cell culture dish. Cantilever holder scanning thermal Optimized for use with Anasys Instruments thermal probes, the cantilever holder scanning thermal allows scanning thermal microscopy as well as nano-ta measurements to be performed. Cantilever holder FluidFM The cantilever holder FluidFM and matching CytoClips with premounted hollow cantilevers can be coupled to a microfluidics pressure control system to allow Fluid Force Microscopy in single cell applications and beyond. Air Holder Holder Liquid Thermal Probe CytoClip 3Background image: Lead Tin Selenide

C3000 controller High-end AFM controller for more performance and precision The versatility and performance of the FlexAFM scan head is brought to its full potential by the C3000 controller. With this AFM controller s fully digital internal data processing, 24-bit ADC/DAC conversion depth, and programmable FPGA CPU, it is a huge step up from the standard Easyscan 2 controller. It allows highspeed data acquisition, dynamic filtering and analysis, and real-time signal monitoring directly from within the C3000 control software. Through soft- and firmware changes, the C3000 controller can be updated and upgraded to support new options and features at any time! Main features All digital data processing in FPGA Lateral force microscopy on mica. Using a 10-µm high-resolution FlexAFM 5 scan head and the C3000 controller, the atomic grid of mica was imaged in LFM mode. 24-bit DACs for accurate scanning with widely varying scan ranges 24-bit ADCs and adaptive filters for high-resolution and low-noise data Fast and sensitive digital Z-feedback and spectroscopy Fully equiped with integrated thermal tuning, data monitoring, user I/O and signal access, advanced operating Additional options Available C3000 controller options/packages include: advanced spectroscopy, signal modulation, advanced lithography, scripting interface, external synchronization. DNA on mica. Scan size: 300 nm. Elastic modulus. Elasticity map of a PS-PB blend (top) and corresponding histogram (bottom). 4

FlexAFM Accessories Extending The Capabilities of Your FlexAFM Research System Nanosurf Isostage Vibration-free measurements with the Nanosurf Isostage: Highly compact active vibration isolation solution Optimized for all Nanosurf AFMs Fast setup: turn on and go! Acoustic Enclosure 100 / 300 / 500 For use with FlexAFM systems with or without Isostage active vibration isolation table Provides acoustic isolation during measurements Also shields against light, electric and air flow disturbances FlexAFM Video Camera See the whole picture with the FlexAFM Video Camera option: Simultaneous top and side view: 3.1 MP, 2.0 1.5 mm, color top view and 1.3 MP, 2.4 2.4 mm, monochrome side view of sample (and cantilever) More comfortable sample positioning and approach Micrometer Translation Stage Accurately position your samples with the FlexAFM Micrometer Translation Stage: Travel: 13 mm in X and Y Repositioning precision: better than 10 µm Straight line accuracy: better than 10 µm Environmental Control Chamber Compatible with FlexAFM and Easyscan 2 AFM / STM (Isostage required) Sample measurements under controlled, dry and/or inert gas atmospheres Small Sample Heater Programmable heating from room temperature to 120 C Sample platform with heater and internal temp. sensor Connection for external temp. sensor (part of contents) Made from selected materials with minimal drift Electrochemistry Stage ECS 204 Perform in situ surface characterization under potentiostatic or galvanostatic control Sample bath constructed of chemically inert materials Thermal Measurement Options Scanning Thermal Microscopy option Nano Thermal Analysis option FlexAFM Inverted Microscope Option Combines the power of inverted and atomic force microscopy for transparent samples in Materials and Life Science: Available for a large variety of inverted microscopes Intuitive use because of parallel AFM and optical image axes, and sample movement along these axes Ability to merge optical information with AFM data FluidFM An enabling technology for micromanipulation of single cells and other small objects, surfaces and tissues: Nanofluidics through a hollow cantilever combined with the positional accuracy and force control of the Nanosurf FlexAFM Specialized application modules for different applications as injection, pickand-place, adhesion force spectroscopy, elasticity measurements, and spotting 5

Functionality and specifications of the FlexAFM 5 scan heads Integral part of the Flex-Axiom system FlexAFM 5 scan head features Y The electro-magnetically actuated flexurebased scanner ensures highly flat and linear motions in XY. X General design Laser / detector Approach Cantilever holder Laser adjustment Sample observation Operating Tripod stand-alone scan head with tip scanner; Flexure-based electromagnetically actuated XY-scanner; Piezo-based Z-actuator; Optical Z-position sensor; Closed loop Z-control High-speed, low-noise 4-quadrant photodiode detector; Choice between red and near-infrared laser; Laser on/off through software and scan head tilting; Optical filters for use with optical microscope phase contrast and fluorescence Approach with continuous DC-motor; Up/down arrows on scan head for manual approach; Software-driven automated final approach Automatic self-alignment for cantilevers with alignment grooves. Manual laser adjustment possible for special cantilevers. No adjustment required upon immersion of cantilever into liquid because of SureAlign laser optics Top and side view in air and liquid; White LEDs (brightness 0 100%); Axial illumination for top view Static Force, Lateral Force, Dynamic Force, Phase Contrast, MFM, EFM, KPFM, Piezo Force, Force Modulation, Scanning Thermal, Spreading Resistance, Multiple Spectroscopy, Lithography and Manipulation. Some may require additional hardware and/or activating of the respective C3000 controller options. FlexAFM 5 scan head specifications with C3000 controller High-speed, low-noise 4-quadrant photo detector ensures high-quality imaging and spectroscopy results. TOP SIDE Scan head type 100-µm 10-µm Sample size Maximum Petri dish height (fluid level) Manual height adjustment range Motorized approach range (at tip position) Unlimited without sample stage 100 mm on sample stage 9 mm (6 mm) 6 mm 2 mm Maximum scan range 100 µm (1) 10 µm (1) Maximum Z-range 10 µm (2) 3 µm (1) XY-linearity mean error < 0.1% XY-flatness at maximum scan range typ. 5 nm typ. 1 nm Detector bandwith DC 4 MHz Detector noise level typ. 60 pm / max. 100 pm (3,4) Z-sensor noise level (RMS) typ. 180 pm / max. 200 pm (3) Z-measurement noise level (RMS, static mode in air) Z-measurement noise level (RMS, dynamic mode in air) Scan head dimensions Scan head weight (1) Manufacturing tolerances ± 5% (2) Manufacturing tolerances ± 10% (3) Measured at 2 khz (4) Measured with XYContr cantilever typ. 100 pm / max. 200 pm typ. 35 pm / max. 50 pm 143 158 53 mm 1.25 kg Compatible cantilevers Top and side view through the FlexAFM optics provide optimal sample observation and cantilever position control. Cantilever holders exist for all commercially available cantilever types (with and without alignment grooves) 6

Functionality and specifications of the C3000 controller Additional options can be activated via software activation codes C3000 controller Standard functionality Standard imaging Imaging functions Standard spectroscopy Spectroscopy functions Standard lithography Sample approach Static force, dynamic force, phase contrast, MFM, friction force, force modulation, spreading resistance Up to 8000 8000 data points with 24-bit zoom in 8 acquisition channels with dynamic digital filters X/Y sample slope correction Force distance, amplitude distance, phase distance Tip current tip voltage Setup wizard for each spectroscopy mode XY-position table: point, line, and grid (max. 64 positions) 3 distinct spectroscopy phases Free vector objects drawing or real-time drawing by mouse Tip lift or force control during movement from point to point Fast home, retract, and advance movement Automatic approach with definable final end position Continuous or step-by-step approach mode C3000 controller Core hardware specifications X/Y/Z-axis scan and position controller X/Y/Z-axis position measurement Excitation & modulation outputs Analog signal input bandwidth Main input signal capturing Additional user signal outputs Additional user signal inputs Additional monitor signal outputs Digital synchronization FPGA module and embedded processor Communication System clock Power 3 24-bit DAC (200 khz) 3 24-bit ADC (200 khz) 4 16-bit DAC (20 MHz) 0 5 MHz 2 16-bit ADC (20 MHz) 2 24-bit ADC (200 khz) 3 24-bit DAC (200 khz) 3 24-bit ADC (200 khz) 2 24-bit ADC (200 khz) 2 digital out, 2 digital in, 2 I2C Bus ALTERA FPGA, 32-bit NIOS-CPU, 80 MHz, 256 MB RAM, multitasking OS USB 2.0 Hi-Speed to PC and scan head interface Internal quarts (10 MHz) or external clock 90 240 V AC, 70 W, 50/60Hz C3000 cantilever calibration option Spring constant calibration Deflection sensitivity calibration C3000 advanced option Additional operating Secondary lock-in amplifier Free resonance detection via thermal tuning Q-Factor calculation Spring constant calculation by Sader method FFT spectrum analyzer, many windowing, averaging Wizard for deflection sensitivity calculation from force distance measurements Automatic mode or user-defined parameters C3000 advanced spectroscopy option Additional spectroscopy functions Additional Stop by input value reached modulation mode Automatic cantilever drift recalibration Unlimited number of spectroscopy data points 5 distinct spectroscopy phases C3000 advanced lithography option Additional lithography C3000 KPFM work package Vector-based lithography with objects on layers with different lithography parameters Bitmap-based lithography Nano printing Enables advanced measurement via an additional digital 2-channel Lock-In. Measure amplitude and phase of an additional signal from many inputs. (e.g higher harmonics, higher resonances, torsional cantilever oscillations, tip voltage modulation, etc.) during imaging and spectroscopy Frequency range: 100 Hz 5 MHz Demodulation bandwidth: 11 Hz 23 khz Amplitude resolution: 20 bit; Phase range: ±180 Reference phase shift: 0 360 (digital) Excitation: tip voltage, 2 user output Extends the advanced option with the Kelvin probe force microscopy (KPFM) mode. In addition to the Lock-In, it provides a tip voltage feedback controller through a special user interface. In addition to the standard signals, contact potential can be measured during imaging and spectroscopy. C3000 signal I/O option Clock input Analog inputs Analog outputs Digital sync Input for an external digital clock (10 MHz, ±1 V) Synchronization of internal Lock-In, PLL, function generators 2 user inputs for imaging and spectroscopy 2 user outputs for spectroscopy modulation, Z-control, etc. 2 digital outputs for synchronization C3000 PFM work package Extends the advanced option with the Piezoresponse force microscopy (PFM) mode through a special user interface. In addition to the standard signals, amplitude and phase of the piezo response signal can be measured during imaging and spectroscopy C3000 scripting interface option C3000 stage control option Drivers Direct control for all supported stage controllers Manual move Via buttons in the C3000 control software Batch Manager Automated movement via position list and scripts Internal scripting COM-API Compatibility Visual Basic script editor Ribbon drop-down menu to access user scripts Control of measurement process and data analysis All applications that support the Microsoft COM Automation standard: e.g. LabVIEW, C#, etc. 7

Flex-Axiom Nanosurf AG Gräubernstrasse 12 14 4410 Liestal Switzerland +41 61 927 47 47 (phone) +41 61 927 47 00 (fax) www.nanosurf.com info@nanosurf.com Nanosurf GmbH Rheinstrasse 5 63225 Langen Germany +49 6103 202 7163 (phone) +49 6103 202 7182 (fax) www.nanosurf.de info@nanosurf.de Nanosurf Inc. 300 Trade Center, Suite 5450 Woburn, MA 01801 United States of America 781 549 7361 (phone) 781 549 7366 (fax) www.nanosurf.com info@nanosurf.com Nanosurf 中国中心 Nanosurf China, Shanghai 上海市天宝路 578 号 (200086) 飘鹰世纪大厦 703 室, 中国 +86 18621896399 ( 电话 ) +86 21 5512 7698 ( 传真 ) www.nanosurf.com info@nanosurf.com Nanosurf and the Nanosurf Logo are trademarks of Nanosurf AG Copyright 2014 Nanosurf AG, Switzerland