EPS AUSTRALIA SERVICES HV TESTING & COMMISSIONING CAPABILITY

Similar documents
Substation Preventive Maintenance

Specialists in HV and MV test and diagnostics. Testing in Substations

Chapter 7 Conclusion 7.1 General

ELE-CMOS-E-2001 Electrical Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

EI HIGH VOLTAGE INSULATION TESTING POLICY

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

ECP HV INSULATION TESTING

PME specialises in developing, implementing and maintaining solutions to the Mining industry.

ECP HV INSULATION TESTING

RESIDUAL LIFE ASSESSMENT OF GENERATOR TRANSFORMERS IN OLD HYDRO POWER PLANTS

Shunt Reactors. Global Top Energy, Machinery & Plant Solution Provider

OMICRON Seminar on Substation Testing and Diagnosis. October 23, 2017 Dubai, United Arab Emirates. October 24, 2017 Abu Dhabi, United Arab Emirates

Africa Utility Week Focus Day Substation Condition Monitoring Benefits of Ultrasound

Condition Assessment of High Voltage Insulation in Power System Equipment. R.E. James and Q. Su. The Institution of Engineering and Technology

Course No: 1 13 (3 Days) FAULT CURRENT CALCULATION & RELAY SETTING & RELAY CO-ORDINATION. Course Content

Innovative Test Techniques and Diagnostic Measurements to Improve the Performance and Reliability of Power System Transformers

Electrical Switchgear & Power Transformer Testing. H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

Benefits of SFRA - Case Studies

Shortcomings of the Low impedance Restricted Earth Fault function as applied to an Auto Transformer. Anura Perera, Paul Keller

MEDIUM & HIGH VOLTAGE

Training Fees 3,300$ per participant including Materials/Handouts, Tea/Coffee Refreshments & International Buffet Lunch.

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

Report on investigation of failure of 315 MVA Auto transformer at 400 kv Bawana Substation of Delhi Transco Ltd.(DTL)

OFFER OF SERVICE / Cité 1200 Logts, Coopérative Granitex Bt. 05, N 01-Bab Ezzouar Alger Algerie

A Review Comprehension: Guideline for Testing of HV, EHV and UHV Substation Equipment

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS. IR Values are to be read on the megger by meggering the Power transformer

7. INSPECTION AND TEST PROCEDURES

CONTENTS. 1. Introduction Generating Stations 9 40

POWER TRANSFORMER. Failure Analysis & Troubleshooting. H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

Monitoring Solutions For Power Transformers, Reactors, Bushings and Instrument Transformers

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

Understanding the Value of Electrical Testing for Power Transformers. Charles Sweetser - OMICRON

TRANSFORMER OPERATIONAL PRINCIPLES, SELECTION & TROUBLESHOOTING

OMICRON Academy Hong Kong. Excellence through Education

The Advantages and Application of Three Winding Transformers

ABB Power Products Service

CASE STUDY- FAULT IN POWER TRANSFORMER AT LOKTAK POWER STATION. - S K Mishra & S K Das NHPC Ltd O&M Division

REPORT ON INVESTIGATION OF FAILURE OF 100 MVA, 220/66-33/11 KV POWER TRANSFORMER AT 220KV GEETA COLONY SUBSTATION OF DELHI TRANSCO LTD.

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

Transformer Testing & Maintenance Fundamentals. AVO Training Institute, Inc. 2018

COURSE PLANNER. Subject: TESTING AND COMMISSIONING OF ELECTRICAL EQUIPMENTS ( ) B.E. Fourth Year (8 th Sem) Branch Electrical Engineering

ELECTRICAL EQUIPMENT. Inspection. H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

Understanding and Extracting Valuable Information from Basic and Advanced Power Transformer Testing Techniques

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

UTILITY & SUBSTATION TESTING

CP CU1. Coupling unit for line and ground testing

Transformer Protection

IN ELECTRICAL ENGINEERING - I C M E T CRAIOVA

Section L5: PRE-ENERGIZATION TEST PROCEDURES FOR LOAD-ONLY ENTITIES AND TRANSMISSION-ONLY ENTITIES

Transformer condition assessment with an integrated test van

Phase Shifting Transformers. Presented by

Hamdy Faramawy Senior Application Specialist ABB Sweden

Discipline Electrical Testing Issue Date Certificate Number T-2837 Valid Until Last Amended on - Page 1 of 6 LOCATION 1

Testing and Diagnostic of Power Transformers & Distribution Transformers

Primary Test Manager (PTM) Testing and management software for primary assets

SERVICE OFFERINGS FOR POWER SYSTEM STUDY & CONDITION MONITORING FOR STATIC EQUIPMENT

TRANSFORMER OPERATIONAL. Principles, Selection & Troubleshooting

TRAX Transformer and Substation Test System

Understanding the Value of Electrical Testing for Power Transformers. Charles Sweetser, OMICRON electronics Corp. USA

ADVANCED CIRCUIT BREAKERS OPERATION AND MAINTENANCE SECTOR / ENGINEERING TECHNICAL & CERTIFICATE OF ATTENDANCE TRAINING COURSE

Končar TMS - Bushing monitoring

TRAX Transformer and Substation Test System

About us. Vision. To lead our field in innovation, quality and customer service.

CPC 100. Multi-functional primary test system for substation commissioning and maintenance

TECHNICAL SPECIFICATION FOR POWER TRANSFORMER

GENERATOR TESTING APPLICATION GUIDE. reliable. precision.

Technical Questionnaire 9.101/6 Transformer Test System. Personal Data. Application. Test of. Delivery scope

Problems connected with Commissioning of Power Transformers

PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS

TRAX Transformer and Substation Test System

Automatic Transformer Winding Analyser

Basic Principles and Operation of Transformer

CPC 100. Multi-functional Primary Test System for Substation Commissioning and Maintenance

ECP GROUND-MOUNTED SWITCHGEAR WITH PROTECTION RELAYS COMMISSIONING PROCEDURE

Transformer Protection Principles

PROTECTION of electricity distribution networks

GIS Instrument Transformers: EMC Conformity Tests for a Reliable Operation in an Upgraded Substation

Transformer Protection

EE223D: Distribution Power Transformer

MSR Series. Modular Series Resonant Systems kV; 500kVA...60,000kVA FEATURES BENEFITS APPLICATIONS 1/6

Hands-On Transformer Testing and Maintenance

CPC 100. Multi-functional primary test system for substation commissioning and maintenance

EE059: Transformer Operation, Maintenance, Diagnosis & Testing

Pomona, CA May 24 & 25, LTC Applications - Location, Series & Preventative Auto Transformers

Application for A Sub-harmonic Protection Relay. ERLPhase Power Technologies

Operational Management of Grid Transformers An Experience of POWERGRID

Continuous Monitoring on the SSE Networks Transmission System

Single Line Diagram of Substations

STS Fully automatic. Large graphic display. Primary injection testing capabilities: up to 3000 A, with the optional module BUX 3000

This webinar brought to you by The Relion Product Family Next Generation Protection and Control IEDs from ABB

Form-IV. Form of Inspection/Test Report. (Under Regulation 43)

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

Protection of Electrical Networks. Christophe Prévé

Effective maintenance test techniques for power transformers

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

Onsite Mobile AC High Voltage Test System

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

ECP GROUND-MOUNTED SWITCHGEAR COMMISSIONING PROCEDURE

Jason Harchick, P.E. Sr. Manager, System Planning and Protection Ryan Young Manager, Substation Engineering

Transcription:

EPS AUSTRALIA SERVICES HV TESTING & COMMISSIONING CAPABILITY

EPS AUSTRALIA SERVICES COMPANY OVERVIEW EPS is a recognised company specialising in Electrical, Instrumentation, Structural, Mechanical and Piping services. We have an appreciation for client and top tier provider expectations and the commitment required in completing technically challenging projects. Our extensive experience has provided us insight into projects to allow us to manage construction verification, Quality Assurance, Completions (Handover & Turnover), Pre-commissioning, Commissioning, Start Up and Operations efficiently. Offering our services as an integrated solution enables complex projects to be completed and managed by a single service provider, leading to a seamless solution for all of your electrical needs.

HV COMMISSIONING SERVICES EPS Group Australia has been involved in numerous projects throughout Australia working on a wide range of electrical systems. These projects have included installation and commissioning of complex protection and control schemes for high voltage electrical generation, transmission and distribution installations. EPS can also assist with investigative works for fault identification and maintenance of existing installations to ensure compliance with relevant standards and codes. Our commissioning team has extensive experience and expertise in the installation, testing and commissioning of all facets of ELV, LV, MV and HV electrical installations, including, but not limited to: Commissioning, planning and progress reporting Test procedure development Inspection and test plan development Inspection and test record development High Voltage Protection Schemes, including Generation, Transmission and Distribution systems as well as communication assisted protection schemes. High Voltage Transformers, with experience in larger units up to 500MVA Earth grid and Earthing system testing Witnessing hold points on vendor deliverables Factory Acceptance Testing and Site Acceptance Testing Construction documentation and operational readiness assessment Supervisory Control and Data Acquisition (SCADA) System Commissioning Circuit Breakers LV & HV (GIS, ACB, VCB and SF6) Current Transformers and Voltage Transformers High Voltage Switchboards High Voltage MCC Switchboards High Voltage Ring Main Units (RMU s) High Voltage Earthing Systems Harmonic Filter Units + Power Factor Correction Units Variable Speed Drives

HV COMMISSIONING SERVICES HV Electrical Field Services Field services include all aspects of testing and commissioning. EPS Group have the full range of test equipment to service all of our customer requirements. General Testing Cable Testing Protection relay & scheme testing and upgrades SCADA System Commissioning High Voltage Transformers up to 500MVA High Voltage Ring Main Units High Voltage EarthingSystems High voltage substation testing Thermography (Thermal imaging) Very Low Frequency Testing (VLF) Dielectric Loss Angle Testing (DLA) Insulation Resistance (IR) and PolarisationIndex (PI) HV Switchboard and Switchgear Testing Current Transformers Voltage Transformers Circuit Breakers (LV and HV) DC Insulation Resistance and Polarization Index Recurrent Surge Oscillograph(RSO) tests Primary Current Injection (up to 800A AC) Primary High Voltage Injection (up to 120kV AC) HV/LV Circuit Breakers Current Transformers Voltage Transformers HV Cable Testing (Paper/Lead, XLPE) Power Factor (Tan Delta) Thermo-graphic imaging Earth Grid Performance Testing Automated and manual single and three phase secondary with GPS time synchronizing capability

HV COMMISSIONING SERVICES Transformer Testing Transformer Testing Partial Discharge tests (PD) Sweep Frequency Response Analysis (SFRA) Current Transformer (CT) testing Oil Quality Analysis Very Low Frequency (VLF) Electromagnetic Core Imperfection Detection test Transformer Ratio tests Air Gap (Rotor) Flux tests Insulation Resistance Polarisation Index Core Grounding Insulation On Load Tap Changer (OLTC) Operation Buchholz relay operation Pressure Relief Device (PRD) operation OLTC Pressure trip operation Gas detector alarm operation DC Winding Resistance Short Circuit Impedance Windings Power Factor Dissipation Test Bushings Power Factor Dissipation Test Excitation Current Test Internal CTs Tests Bushings DLA (Dielectric Loss Angle) measurement Winding insulation DLA (Dielectric Loss Angle) measurement Leakage Reactance measurement HV Connections Contact Resistance Tests Transformer protection secondary injection and integration tests Differential Stability using portable generator: Through faults In zone faults Restricted Earth Fault Stability using portable generator or current injection set as required by the scheme: Through faults In zone faults

HV COMMISSIONING SERVICES EPS Group Australia has the capability to provide technical staff, proven project management systems and technical services for any project progression from commissioning, completions to operation requirements. Our team will ensure a seamless transition from construction to commissioning and on to operations. EPS Group have the capability to mobilise Commissioning Managers, Senior Commissioning Engineers, Commissioning Engineers, Senior HV Testers, HV Testers, HV Technicians, Hv Operators and Electricians to suit any project requirement. CURRENT & RECENT PROJECTS EPS Group Australia specialise in multi-disciplined verification, testing, commissioning and completion services on Oil & Gas, Mining and Metals, Utility and Infrastructure projects throughout Australia. We have more than 30 years experience in successfully supporting and delivering major projects in a timely fashion. In this time we have developed and refined the resource requirements needed for any project. QCLNG Project High Voltage Commissioning EPS Group Australia provided specialised primary and secondary High Voltage and Low Voltage testing and commissioning services for the 132kV/33kV/11kV/6.6kV/3.3kV network on multiple sites in the Surat Basin. Solomon Hub 132KV Scheme Commissioning EPS Group Australia provided Commissioning Management, High Voltage and Low Voltage Testing and all required commissioning support for the 132KV Scheme in the Solomon mining hub

EPS AUSTRALIA SERVICES Solomon Project High Voltage Terminations and Testing EPS Group Australia has provided specialist testing services to RCR on the FMG Solomon Port Expansion Project Christmas Creek OPF Shutdowns High Voltage Testing EPS Group Australia provides High Voltage support required for the operation of the FMG Solomon mine in the Pilbara Kings Valley OPF High Voltage Testing & Commissioning EPS Group Australia provided High Voltage and Low Voltage testing and all required commissioning support for the 132KV Scheme Solomon Project High Voltage Terminations and Testing EPS Group Australia has provided specialist testing services to RCR on the FMG Solomon Port Expansion Project

Sydney Suite 1702, Tower 2, 101 Grafton St, Melbourne Suite 1509-1512, Level 15, 401 Docklands Drive, Docklands VIC 3008 Brisbane Level 5, 320 Adelaide Street, Brisbane QLD 4000 Darwin Suite 4, Level 9, 9 Cavenagh Street, Darwin NT 0800