Getting Started. MSO/DPO Series Oscilloscopes. Basic Concepts

Similar documents
Introduction to Oscilloscopes Instructor s Guide

Faculty of Engineering, Thammasat University

Digital Debug With Oscilloscopes Lab Experiment

MSO-5000B Mixed Storage Oscilloscope User Manual

DSO5000P Series Digital Storage Oscilloscope User Manual. (Version 1.1)

DST Series B Type Digital Storage Oscilloscope User Manual

DSO1000E/F Series Digital Storage Oscilloscope User Manual. (Version 1.3)

Specifications for DS1000CA Series

User Manual Series. Digital Storage Oscilloscope 6810, 6806, March Copyright Protek Test & Measurement 2005 All Rights Reserved

DSO4000BC Series Digital Storage Oscilloscope User Manual

Chapter 5 : Specifications

Appendix A: Specifications

Reference. TDS6000 Series Digital Storage Oscilloscopes

DSO4000 Series Digital Storage Oscilloscope User Manual. (Version 1.3)

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Easy to Use Design.

Measurement Bench. Accessories. Power supply. Wave form generator. Multimetre. Oscilloscope. Dr. L.Scucchia

N acquisitions, all channels simultaneously, N is selectable from 4, 16, 64, and 128 Inputs

Oscilloscope Fundamentals. For Electrical Engineering and Physics Undergraduate Students

UNIVERSITY OF CALIFORNIA, SANTA BARBARA Department of Electrical and Computer Engineering. ECE 2A & 2B Laboratory Equipment Information

DS1000B Series Digital Oscilloscopes

EENG-201 Experiment # 4: Function Generator, Oscilloscope

ECE65 Introduction to the Function Generator and the Oscilloscope Created by: Eldridge Alcantara (Spring 2007)

TDS1000B and TDS2000B Series Oscilloscopes Operator Training Kit Manual

The oscilloscope is an essential tool if you plan to design or repair electronic equipment. It lets you "see" electrical signals.

Advanced Lab LAB 6: Signal Acquisition & Spectrum Analysis Using VirtualBench DSA Equipment: Objectives:

54645D. Mixed Signal Oscilloscope

Department of Electrical & Computer Engineering OSCILLOSCOPE GUIDE. Tektronix TDS2000 Series

DSO8000E SERIES HANDHELD OSCILLOSCOPE

LAB #7: Digital Signal Processing

Experiment #2: Introduction to Lab Equipment: Function Generator, Oscilloscope, and Multisim

XYZs of Oscilloscopes. Primer

PHYSICS 171 UNIVERSITY PHYSICS LAB II. Experiment 4. Alternating Current Measurement

Department of Electrical and Computer Engineering. Laboratory Experiment 1. Function Generator and Oscilloscope

B. Equipment. Advanced Lab

DS1102E, DS1052E, DS1102D, DS1052D

USER S MANUAL 1062S/1122S/1152S/1202S

EXPERIMENT NUMBER 2 BASIC OSCILLOSCOPE OPERATIONS

TDS1000 & TDS2000 Series Oscilloscopes Operator Training Kit Manual

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

XYZs of Oscilloscopes PRIMER

Data Sheet. Digital Storage Oscilloscope. Features & Benefits. Applications. Ease-of-Use Feature DSO5202BMT DSO5102BMT DSO5062BMT

AE Agricultural Customer Services Play-by-Play Tekscope Manual

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

How to Setup and Use an Oscilloscope

LAB I. INTRODUCTION TO LAB EQUIPMENT

Digital Fundamentals 8/25/2016. Summary. Summary. Floyd. Chapter 1. Analog Quantities

LAB 7: THE OSCILLOSCOPE

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Introduction to Lab Instruments

ENGR 210 Lab 6 Use of the Function Generator & Oscilloscope

DPO3PWR, MDO3PWR and DPO4PWR Power Analysis Modules ZZZ User Manual

Combinational logic: Breadboard adders

Getting the most out of your Measurements Workshop. Mike Schnecker

DSO 3000 Series Oscilloscope

Testing Sensors & Actors Using Digital Oscilloscopes

2 Oscilloscope Familiarization

DSOXEDK Educator s Oscilloscope Training Kit. Lab Guide and Tutorial for Agilent 4000 X-Series Oscilloscopes

Sampling and Reconstruction

How to Setup a Real-time Oscilloscope to Measure Jitter

Tektronix MDO3000 Series Oscilloscope. Demonstration Guide

WELCOME TO PHYC 307L Junior Lab II

UCE-DSO210 DIGITAL OSCILLOSCOPE USER MANUAL. FATIH GENÇ UCORE ELECTRONICS REV1

What the LSA1000 Does and How

Signal Processing for Digitizers

Sonoma State University Department of Engineering Science Spring 2017

DS1052E, DS1102D, DS1052D

Digital Fundamentals

UTD4000 Four-channel User Manual. Safety Instructions

Help Volume Agilent Technologies. All rights reserved. Instrument: Agilent Technologies 16533/34A Digitizing Oscilloscope

Exercise 4 - THE OSCILLOSCOPE

The Oscilloscope. Vision is the art of seeing things invisible. J. Swift ( ) OBJECTIVE To learn to operate a digital oscilloscope.

LABORATORY 4. Palomar College ENGR210 Spring 2017 ASSIGNED: 3/21/17

Fourier Theory & Practice, Part II: Practice Operating the Agilent Series Scope with Measurement/Storage Module

Laboratory Equipment Instruction Manual 2011

ECE 480: SENIOR DESIGN LABORATORY

OL-612 PORTABLE MIXED SIGNAL DIGITAL STORAGE OSCILLOSCOPE

User s Guide RIGOL. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Publication number UGA July 2009

Dr. Cahit Karakuş ANALOG SİNYALLER

PeakTech 1210/1215. Bedienungsanleitung / operation manual. Digital Oszilloskop mit Farbdisplay Digital Oscilloscope / with colour display

Name EET 1131 Lab #2 Oscilloscope and Multisim

Oscilloscope Operation. Visualizing Signals and Making Measurements

Cornerstone Electronics Technology and Robotics Week 21 Electricity & Electronics Section 10.5, Oscilloscope

Elizabethtown College Department of Physics and Engineering PHY104. Lab # 9- Oscilloscope and RC Circuit

EE 3302 LAB 1 EQIUPMENT ORIENTATION

Announcement. Copyright. Trademark Logo. Declaration

Multiple Instrument Station Module

Laboratory 1 Generating and viewing signals rev. 20e. Oscilloscope Settings

Sirindhorn International Institute of Technology Thammasat University at Rangsit

DSOXEDK Educator s Oscilloscope Training Kit

ENGR 1110: Introduction to Engineering Lab 7 Pulse Width Modulation (PWM)

Tektronix digital oscilloscope, BK Precision Function Generator, coaxial cables, breadboard, the crystal earpiece from your AM radio kit.

Lab 6 Instrument Familiarization

Cleverscope Model CS320A - CS328A Data Sheet

PeakTech 1190/1230. Operation manual. Digital Oscilloscope / with 16-CH logic analyzer

University of California, San Diego Department of Electrical and Computer Engineering

HDSO1000 Series Handheld Oscilloscope User Manual

OD-610 OD-620 DIGITAL OSCILLOSCOPE

Introduction to Basic Laboratory Instruments

LeCroy 9304A, 9304AM Digital Oscilloscopes 200 MHz Bandwidth, 100 MS/s. Main Features

U1571A Ni-MH Battery Pack for U1600A Handheld Oscilloscopes

Transcription:

Getting Started MSO/DPO Series Oscilloscopes Basic Concepts 001-1523-00

Getting Started 1.1 Getting Started What is an oscilloscope? An oscilloscope is a device that draws a graph of an electrical signal. In most applications, the graph shows how signals change over time: the vertical (Y) axis represents voltage and the horizontal (X) axis represents time. The intensity or brightness of a waveform is sometimes called the Z axis.

Z (intensity) Y (voltage) X (time)

Getting Started 1.2 How does a digital oscilloscope work? 1 2 3 4 5 6 The signal travels through the probe to the vertical amplifier. Next, an analog-to-digital converter (A/D) digitizes the signal by sampling the signal at discrete points in time and converting the signal s voltage at these points into digital values called sample points. The sample points from the A/D are stored in acquisition memory as waveform points. Together, the waveform points comprise one waveform record. The number of waveform points used to create a waveform is called the record length. The trigger determines the start and stop points of the record. The signal path includes a microprocessor, which measures the signal and formats it for display. The signal then passes through the display memory and is displayed on the oscilloscope display.

1 2 3 4 5 6 Amp A/D Acquisition Micro- Display Memory processor Memory Display

Getting Started 1.3 What are the differences between an MSO and a DPO Oscilloscope? Digital Phosphor Oscilloscope (DPO) A DPO has only one type of input - typically two or four analog channels. Analog inputs only Typically two or four

Mixed Signal Oscilloscope (MSO) An MSO has two kinds of inputs - typically two or four analog channels, and a larger number (typically sixteen) of digital channels for advanced digital measurements. Applications include characterization and debugging of analog-to-digital converters (ADCs), digital-to-analog converters (DACs), and control systems. Digital inputs Typically sixteen + Analog inputs Typically two or four

Getting Started 1.4 Acquisition readout Trigger status Analog baseline indicator Digital channels (MSO) Channel readout Horizontal scale readout

Expansion point Trigger position FilterVu indicator Vertical Trigger level Trigger readout Measurement readout Horizontal position readout

Vertical 2.1 Vertical What are Vertical Controls used for? You can change the vertical position of waveforms by moving them up or down on the display. To compare data, you can align a waveform above another or you can align waveforms on top of each other. You can change the vertical scale of a waveform. The waveform display will contract or expand around the ground reference level.

Vertical Controls 1 2

Vertical 2.2 1 Position knob Moves the waveform up and down on the display. Before After 2 Scale (volts-per-division) Varies the size of the waveform on the screen. Before After

The volts/div setting is a scale factor. If the volts/div setting is 5 volts, then each vertical division represents 5 volts and an entire screen of 8 divisions can display 40 volts from top to bottom. } } } } } } } } 5 volts 5 volts 5 volts 5 volts 5 volts 5 volts 5 volts 5 volts x 8div = 40 volts from top to bottom

Vertical/FFT 2.3 What is Fast Fourier Transform (FFT) used for? You can use the FFT Math mode to convert a time-domain signal into its frequency components (spectrum). You can use FFT for the following kinds of analysis: analyzing harmonics, characterizing noise, testing impulse response, and analyzing vibration. The MSO/DPO2000 Series FFT is calculated from 5000 points on the display. The resulting FFT spectrum goes from DC (0 Hz) to onehalf the sample rate.

Frequency component Horizontal Additional information in about FFT Horizontal scale in frequency per division Frequency at the center graticule Window type: Allows you to trade off the frequency resolution and amplitude accuracy that you will see in the FFT spectrum. Vertical scale in db per division (0 db = 1VRMS)

Horizontal Controls 3.1 What are Horizontal Controls used for? You can adjust the Horizontal Position control to view waveform data before the trigger, after the trigger, or some of each. Horizontal When you change the horizontal position of a waveform you are changing the time between the trigger and the center of the display. This moves the waveform to the right or left on the display.

Horizontal Controls 1 2 3

Horizontal Controls 3.2 1 Position knob Adjusts the horizontal position of all channel and math waveforms. The resolution of this control varies with the time base setting. Before Example: Post trigger acquisition After Example: Pre-trigger acquisition

2 Acquire button Determines how the oscilloscope processes the digitized signal before displaying it. There are two acquisition modes: Sample and Average. Sample mode: Samples are taken in evenly-spaced intervals to construct the waveform. This mode accurately represents signals most of the time. Average mode: Several waveforms are acquired and averaged point-by-point to obtain the average voltage at each time sample in the acquisition. This mode is used to reduce random noise.

Horizontal Controls 3.3 3 Scale knob The scale knob (sec/div) setting varies the rate at which the waveform is drawn across the screen. Before Example: 1 sec After Example: 10 sec The sec/div setting is a scale factor. If the sec/div setting is 1 second, then each horizontal division represents 1 division and an entire screen of 10 divisions can display 10 seconds from left to right.

Trigger } } } } } } } } } } 1 sec 1 sec 1 sec 1 sec 1 sec 1 sec 1 sec 1 sec 1 sec 1 sec x 10 div = 10 seconds from left to right

Trigger Controls 4.1 What are Trigger Controls used for? Trigger controls allow you to capture single-shot waveforms and stabilize repetitive waveforms. Trigger Imagine the jumble on the screen that would result if each time the waveform was drawn across the screen, the drawing began at a different part of the signal. The trigger ensures the same part of the waveform is drawn each time, making repetitive waveforms appear stationary.

Trigger Controls 1 2a 3 2b

Trigger Controls 4.2 What does a Trigger do? When the signal matches the trigger setting, the oscilloscope captures the signal and displays it around the trigger point. Edge triggering is used most often; it captures the signal as it passes through a specified voltage level on a rising or falling edge. Untriggered display Triggered display

1 Trig Menu Displays the Trigger Menu 5a 5b 5c 5f 5a Type Cycles through different trigger types Edge triggers are the simplest and most commonly used trigger type, with both analog and digital signals. An edge trigger event occurs when the trigger source passes through a specified voltage level in the specified direction. Pulse width triggering, allows you to monitor a signal indefinitely and trigger on the first occurrence of a pulse with a duration (pulse width) that is outside the specified limits. Runt triggering allows you to define two levels (or thresholds). A trigger occurs when a pulse crosses one, but not both thresholds. Logic triggering allows you to trigger on any logical combination of available input channels especially useful in verifying the operation of digital logic. Setup-and Hold triggering allows you to capture setup and hold violations. Rise/Fall Time Triggering allows you to selectively trigger on fast or slow edges. Video trigger on specified fields or lines of a composite video signal. Bus trigger is used when there are various parallel or serial bus conditions.

Trigger Controls 4.3 5b Source Determines which signal is compared to the trigger settings. Analog channels Aux In channel AC Line Digital channels (MSO) 5d

5c Coupling High frequency, low frequency, and noise rejection trigger coupling are useful for eliminating noise from the trigger signal to prevent false triggering. DC Passes all components of the signal HF Reject attenuates the high frequency components of the signal LF Reject attenuates the low frequency components of the signal Noise Reject adds hysteresis to the trigger circuitry to reduce the chance of falsely triggering on noise 5d Mode Determines whether or not the oscilloscope draws a waveform based on a signal condition. In Auto mode the scope displays a signal, even without a trigger. In Normal mode the scope only displays a signal if the input signal reaches the set trigger point; otherwise the last acquired waveform remains on the display. After a trigger is detected, the scope acquires and displays one waveform.

Trigger Controls 4.4 2a Level When you use an Edge or Pulse trigger, the Level knob sets the amplitude level that the signal must cross to acquire a waveform. Before After 2b Set to 50% (Push to Set) The trigger level is set to the vertical midpoint between the peaks of the trigger signal. Before After

3 Force Trig Completes an acquisition regardless of an adequate trigger signal. This button has no effect if the acquisition is already stopped. Before After Probing

Probing 5.1 Probing basics Choose a probe that exceeds the signal s bandwidth by 5 times for accurate reconstruction of the signal. Probing Remember to connect the probe s ground clip to a known ground in the circuit under test. Measuring a signal requires two connections: the probe tip connection and the ground connection. Don t forget to compensate passive voltage probes to the oscilloscope.

Probe connections 1 2

Probing 5.2 1 CH1 BNC To connect the probe, align the slot in the probe connector with key on the BNC, push to connect and twist to the right to lock the probe in place. 2 Probe comp connector Connect the probe tip to the bottom connector and the ground to the top connector labeled ground. Verify your probe is compensated correctly Check the shape of the displayed waveform. Overcompensated Undercompensated Compensated Correctly

Standard P2221 MSO/DPO Analog Probe Probe tip Adjustment tool Retractable hook tip BNC connector Ground lead Measurements

Measurements 6.1 Measurements The oscilloscope can help you to analyze your waveform through measurements. There are several ways to take measurements. You can use the graticule, the cursors, or automatic measurements. Automatic measurements use on-screen readouts to show measurement results. These readouts are updated periodically as the oscilloscope acquires new data. Measurements

1 Measure button

Measurements 6.2 The following automatic measurements are available: ( ) 1 Frequency (Hertz) = t Frequency is the reciprocal of Period. Frequency is measured over the first cycle. Period (seconds) = t Period is the time required to complete the first cycle. The first cycle is the time between the first two positive crossings, or the first two negative crossings, at the Mid Reference level. Rise Time (seconds) = t Rise Time is the time required for the first rising edge to rise from the Low Reference level to the High Reference level. Fall Time (seconds) = t Fall Time is the time required for the first falling edge to fall from the High Reference level to the Low Reference level.

Delay (seconds) = t Delay is the time between the first occurrences of the specified Mid Reference crossings of two waveforms. ( ) t1 Phase ( ) = t2 x 360 Phase is the ratio of the Delay between the first Mid Reference crossings of two waveforms (t1) to the Period of the source (t2) waveform. Phase is expressed in degrees. 360 degrees comprise one cycle. Positive Pulse Width (seconds) = t Positive Pulse Width is the time between the Mid Reference crossings of the first positive pulse. Negative Pulse Width (seconds) = t Negative Pulse Width is the time between the Mid Reference crossings of the first negative pulse. ( ) t1 Positive Duty Cycle (%) = t2 x 100% Positive Duty Cycle is the ratio of the Positive Pulse Width (t1) to the Period (t2). Positive Duty Cycle is measured over the first cycle.

Measurements 6.3 ( ) t1 Negative Duty Cycle (%) = t2 x 100% Negative Duty Cycle is the ratio of the Negative Pulse Width (t1) to the Period (t2). Negative Duty Cycle is measured over the first cycle. Burst Width (seconds) = t Burst Width is the time from the first Mid Reference crossing to the last Mid Reference crossing. Peak-to-peak (Volts) = a Peak-to-peak is the difference between the Max value and the Min value. Amplitude (Volts) = a Amplitude is the difference between the High value and the Low value. Max (Volts) Max is the maximum value.

Min (Volts) Min is the minimum value. High (Volts) If the High-Low Method is Histogram, High is the highest density of points above the midpoint of the waveform. If the High-Low Method is Min-Max, High is equal to Max. Low (Volts) If the High-Low Method is Histogram, Low is the highest density of points below the midpoint of the waveform. If the High-Low Method is Min-Max, Low is equal to Min. a1 Positive Overshoot (%) = ( a2) x 100% Positive Overshoot is the difference between Max and High (a1), divided by Amplitude (a2). a1 Negative Overshoot (%) = ( a2) x 100% Negative Overshoot is the difference between Min and Low (a1), divided by Amplitude (a2).

Measurements 6.4 ( S0 + S1 +... + Sn ) Mean (Volts) = n Mean is the arithmetic mean value over the entire record. ( S0 + S1 +... + Sn ) Cycle Mean (Volts) = n Cycle Mean is the arithmetic mean value. Cycle Mean is calculated over the first cycle. ( S0 2 + S1 2 +... + Sn 2 ) RMS (Volts) = n RMS is the true Root Mean Square value over the entire record. ( S0 2 + S1 2 +... + Sn 2 ) Cycle RMS (Volts) = n Cycle RMS is the true Root Mean Square value. Cycle RMS is calculated over the first cycle. Positive Pulse Count = n Positive Pulse Count is the number of positive pulses that rise above the Mid Reference level.

Negative Pulse Count = n Negative Pulse Count is the number of negative pulses that fall below the Mid Reference level. Rising Edge Count = n Rising Edge Count is the number of positive transitions from the Low Reference value to the High Reference value. Falling Edge Count = n Falling Edge Count is the number of negative transitions from the High Reference value to the Low Reference value. Area (Volt-seconds) = ( S0 + S1 +... + Sn ) x (sample interval) Area is the area under the curve, calculated by integrating the samples. The area measured above ground is positive. The area measured below ground is negative. Cycle Area (Volt-seconds) = ( S0 + S1 +... + Sn ) x (sample interval) Cycle Area is the area under the curve, calculated by integrating the samples in the first cycle. The area measured above ground is positive. The area measured below ground is negative.

For the most current information visit our website at tektronix.com/oscilloscopes Copyright Tektronix