Type Nominal voltage (V) Code HSV V

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv


QUINT-PS-24DC/24DC/10

AI-517-B1. Analog Input Module (open < 3.8 ma)

Temperature Input Module for Zone 1 Series 9482/32

02/11/2015

Speed and Key Monitor Specifications

08/07/2015

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

AI 043 S-DIAS Analog Input Module

Coupling Relays and Converters

02/11/2015

MINI-PS AC/24DC/1.3

Contactors and Contactor Assemblies

Analog Universal Module HART for Zone 2 Series 9468/33

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

22/10/2012

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

NI REM Remote I/O Overview DATASHEET. Temperature Input Module for Remote I/O

Electronic Thermostat TE-1 Version according to EN

02/11/2015

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

C series Product brief

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

05/09/2012

27/04/2015

08/07/2015

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

CP-T range Product group picture

Shaft Absolute Vibration Monitor Specifications

CP-E range Benefits and advantages

Electronic timer CT-TGD.22

02/11/2015

Type CP-S, CP-C & CP-A Switch mode

Isolators A3/1.

Electronic timer CT-SDD.22

Thermistor motor protection relays

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

QUINT-PS AC/24DC/40

Zelio Control Measurement Relays

Output of three-phase motors at 50 Hz and 400 V

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

02/11/2015

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

CP-T range Benefits and advantages

EN 50178, IEC

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

UniStream Uni-I/O Modules

02/11/2015

PART NUMBERING SYSTEM

02/11/2015

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

20 General technical data XI/ON

s Climatix extension module 26 I/Os POL985.00/XXX

APPENDIX APPENDIX A 1

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Custom "Compact" range with display CD20 Custom Part number

Theta 20A / 20V. Technical Data Sheet. Special Features

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

PART NUMBERING SYSTEM

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Three-phase monitoring relays CM-PFE and CM-PFE.2

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

02/11/2015

This data sheet is only valid in association with the IL SYS INST UM E user manual.

Digital Input Output Module for Zone 2 Series 9470/33

CM3-SP04EAO CM3-SP04EAA CM3-SP04EOAI CM3-SP04EOAV

Digital Input Output Module for Zone 2 Series 9470/33

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

CSI 9330 Vibration Transmitter

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

Temperature transmitter itemp PCP DIN rail TMT 121

QUINT-PS/ 3AC/24DC/10

9330 Vibration Transmitter

Analog amplifier RA. RE Edition: Replaces:

Power Electronics. POWERSWITCH Semiconductor Contactor BF 9250, BH 9250

2-channel speed sensor GEL 247 Compact sensor for harsh applications

24/07/2012

POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL

Insulation Guard IW 1000 Monitoring of ungrounded AC- and DC voltage systems up to 690V

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Transcription:

, 4-channel Subject to technical modification 716218 Identification Type TR-1-6218 4-channel Part-No. 716218 Use/Area of application Description The temperature controller has 4 separate channels. The semiconductor outputs are clocked to the set setpoint value (pulse width modulation). The sensors are monitored via a centralised alarm for sensor break and short circuit. The status output is an isolated semiconductor output. One LED per channel lights up when the controller is operational (no malfunction present). Access (analog) Measurement input PT1000 (DIN EN 60751) Sensor current 0.5 ma Measuring range -40 C to 85 C Protection device Varistor, low-pass Load Side Switching voltage AC 230 V ± 40 % DC 250 V ± 20 % clocked max. 10 A per canal Varistor Function The output is clocked to the setpoint value (pulse width modulation) Switching frequency with duty factor 01:01 1.2 Hz Varistor Setpoint value, channel 1 8 C (setpoint-value clocking -2K to +2K) Setpoint value, channel 2 8 C (setpoint-value clocking -2K to +2K) Setpoint value, channel 3 26 C (setpoint-value clocking -2K to +2K) Setpoint value, channel 4 26 C (setpoint-value clocking -2K to +2K) Input digital (positive clocking) Signal characteristic curve "0" signal: DC 0... 6 V "1" signal: DC 10... 30 V Protection device Input Varistor Part-No. 716218 page 1 of 3

, 4-channel Status output Output Switching voltage Status Indication The output is switched through when there are no sensor malfunctions. DC 5-30 V max. 50 ma 1 yellow LED per channel sensor operational 1 green LED supply voltage General Supply voltage DC 24 V Voltage range DC 16.8 30.0 V Current Consumption per LED max. 20 ma Installation postition Horizontal Distance to next device: min. 100 mm Ventilation slots: top and bottom Termination spring terminal: single stranded 0.5 2.5 mm 2 ; fine stranded 0.5 2.5 mm 2 Protection class IP 20 Galvanic isolation I/O AC 2.5 kv to outputs AC 1.5 kv to all other circuits Clearance/creep. dist. 1.6 mm (contol/load side) Dimensions (w h d) 210.0 120.0 74.0 mm Weight (kg/piece) 1.100 (kg/piece) Operation temperature range -40 C 70 C (+85 C 10 min) Storage temperature range -40 85 C Relative humidity 100 % brief condensation Miscellaneous Standards Electronic equipment on railway vehicles: EN 50155 Electromagnetic compatibility: EN 50121-3-2 Insulation coordination: EN 50124-1 Vibrations and shocks: EN50155/61373 The standard applicable to this product is dependent on the version available for development. The standards applicable to this product are available on request. Comments The temperature controller may only be operated with a protective conductor connected. In the event of a fault (short circuit, sensor break) the channel affected is deactivated and the status output disabled. The other channels continue to operate. Dimensions Part-No. 716218 page 2 of 3

, 4-channel Circuit diagram Part-No. 716218 page 3 of 3

Subject to technical modification 762029 Identification Type TR-6-2029 Part-No. 762029 Use/Area of application Description The temperature controller has 4 separate channels. The semiconductor outputs are clocked to the set setpoint value (pulse width modulation). The sensors are monitored via a centralised alarm for sensor break and short circuit. The status output is an isolated semiconductor output. One LED per channel lights up when the controller is operational (no malfunction present). Access (analog) Measurement input PT1000 (DIN EN 60751) Sensor current 1.0 ma Protection device Load Side Switching voltage Channel 1-4: DC 16.8 30 V (supplied by U B ) max. 50 ma Function The output is clocked to the setpoint value (pulse width modulation) Switching frequency with duty factor 01:01 25 Hz Setpoint value, channel 1 Setpoint value, channel 2 Setpoint value, channel 3 26 C (setpoint-value clocking 24 C to 28 C) Setpoint value, channel 4 26 C (setpoint-value clocking 24 C to 28 C) Status output Output Switching voltage Status Indication The output is switched through and the LED lights up when there are no sensor malfunctions. DC 5-30 V max. 50 ma LED yellow Part-No. 762029 page 1 of 3

General Supply voltage Voltage range Current Consumption per LED Termination DC 24 V DC 16.8 30.0 V 45 ma spring terminal single stranded 0.8 2.5 mm 2 ; fine stranded 0.8 2.5 mm 2 Protection class IP 20 Galvanic isolation I/O DC 500 V Dimensions (w h d) 22.5 80.0 84.0 mm Weight (kg/piece) 0.072 (kg/piece) Operation temperature range -40 70 C Storage temperature range -40 80 C Rated insulation voltage 50 V Contamination level 2 Over voltage category I Miscellaneous Standards Electronic equipment on railway vehicles: EN 50155 Electromagnetic compatibility: EN 50121-3-2 Insulation coordination: EN 50124-1 Vibrations and shocks: EN50155/61373 The standard applicable to this product is dependent on the version available for development. The standards applicable to this product are available on request. Comments In the event of a fault (short circuit, sensor break) the channel affected is deactivated (output 0 V) and the status output disabled. The other channels continue to operate. Dimensions Part-No. 762029 page 2 of 3

Circuit diagram Part-No. 762029 page 3 of 3

Subject to technical modification 762031 Identification Type TR-6-2031 Part-No. 762031 Use/Area of application Description The temperature controller has 4 separate channels. The semiconductor outputs are clocked to the set setpoint value (pulse width modulation). The sensors are monitored via a centralised alarm for sensor break and short circuit. The status output is an isolated semiconductor output. One LED per channel lights up when the controller is operational (no malfunction present). Access (analog) Measurement input PT1000 (DIN EN 60751) Sensor current 1.0 ma Protection device Load Side Switching voltage Channel 1-4: DC 16.8 30 V (supplied by U B ) max. 50 ma Function The output is clocked to the setpoint value (pulse width modulation) Switching frequency with duty factor 01:01 25 Hz Setpoint value, channel 1 Setpoint value, channel 2 Setpoint value, channel 3 Setpoint value, channel 4 Status output Output Switching voltage Status Indication The output is switched through and the LED lights up when there are no sensor malfunctions. DC 5-30 V max. 50 ma LED yellow Part-No. 762031 page 1 of 3

General Supply voltage Voltage range Current Consumption per LED Termination DC 24 V DC 16.8 30.0 V 45 ma spring terminal single stranded 0.8 2.5 mm 2 ; fine stranded 0.8 2.5 mm 2 Protection class IP 20 Galvanic isolation I/O DC 500 V Dimensions (w h d) 22.5 80.0 84.0 mm Weight (kg/piece) 0.072 (kg/piece) Operation temperature range -40 70 C Storage temperature range -40 80 C Rated insulation voltage 50 V Contamination level 2 Over voltage category I Miscellaneous Standards Electronic equipment on railway vehicles: EN 50155 Electromagnetic compatibility: EN 50121-3-2 Insulation coordination: EN 50124-1 Vibrations and shocks: EN50155/61373 The standard applicable to this product is dependent on the version available for development. The standards applicable to this product are available on request. Comments In the event of a fault (short circuit, sensor break) the channel affected is deactivated (output 0 V) and the status output disabled. The other channels continue to operate. Dimensions Part-No. 762031 page 2 of 3

Circuit diagram Part-No. 762031 page 3 of 3

Subject to technical modification 762088 Identification Type TR-6-2088 Part-No. 762088 Use/Area of application Description The temperature controller has 4 separate channels. The semiconductor outputs are clocked to the permanently set setpoint value (pulse width modulation). The sensors are monitored via a centralised alarm for sensor break and short circuit. The status output is an isolated semiconductor output. An LED lights up when the controller is operational (no malfunction present). Access (analog) Measurement input PT1000 (DIN EN 60751) Sensor current 1.0 ma Protection device Load Side Switching voltage (Channel 1 4 DC 16.8 30 V (supplied by U B ) (Channel 1 4) max. 50 ma Function The output is clocked to the setpoint value (pulse width modulation) Switching frequency with duty factor 01:01 0.6 Hz Setpoint value, channel 1 Setpoint value, channel 2 Setpoint value, channel 3 26 C (setpoint-value clocking 24 C to 28 C) Setpoint value, channel 4 26 C (setpoint-value clocking 24 C to 28 C) Status output Switching voltage Status Indication DC 5-30 V max. 50 ma LED yellow - The output is switched through and the LED lights up when there are no malfunctions. General Part-No. 762088 page 1 of 3

Voltage range Nominal voltage U N Rated current (at U N ) Termination DC 16.8 30.0 V DC 24 V 45 ma spring terminal single stranded 0.8 2.5 mm 2 ; fine stranded 0.8 2.5 mm 2 Protection class IP 20 Galvanic isolation I/O DC 500 V Dimensions (w h d) 22.5 80.0 84.0 mm Weight (kg/piece) 0.072 (kg/piece) Operation temperature range -40 70 C Storage temperature range -40 80 C Rated insulation voltage 50 V Contamination level 2 Over voltage category I Miscellaneous Standards Electronic equipment on railway vehicles: EN 50155 Electromagnetic compatibility: EN 50121-3-2 Insulation coordination: EN 50124-1 Vibrations and shocks: EN50155/61373 The standard applicable to this product is dependent on the version available for development. The standards applicable to this product are available on request. Comments In the event of a fault (short circuit, sensor break) the channel affected is deactivated (output 0 V) and the status output disabled. The other channels continue to operate. Dimensions Part-No. 762088 page 2 of 3