BumbleBee. High Voltage Differential Probe Ord.-No: Features:

Similar documents
supplies and frequency converters. BumbleBee is also very effective in fast transient measurements

PHV RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

Supplied in carry case with additional accessories The PHV 1000-RO is a 400 MHz, standard sized, 100:1 passive probe designed for instruments

PMT 221A. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design. Interchangeable Spring Contact Tip

PMT 211A-RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

As all PMK probes the PML 751-RO features CeramCore TM technology. The entire probe

PML 711A-RO High impedance passive probe Features:

PHV 1000-RO. High impedance passive probe. Features: CeramCore TM hybrid probe. Modular construction. Coaxial design

PML 791-RO. High impedance passive probe. Features: 2.5 mm Diameter Tip. Coaxial Design. Interchangeable Spring Contact Tip

PKT 512A-RO High Impedance Passive Cable Divider

PHV RO High Voltage Passive Probe. Instruction Manual

TETRIS 1000 High Impedance Active Probe. Instruction Manual

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

TETRIS User's Guide. High Impedance Active Probe DO177-1

400 MHz Passive High-Voltage Probe R&S RT-ZH

TK 100 Probe Calibrator. Instruction Manual


TA MHz oscilloscope probe TA MHz oscilloscope probe

TT-SI MHz Active Differential Probe

TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

TT-SI MHz DIFFERENTIAL PROBE

TT-SI 9001 / TT-SI MHz Active Differential Probes

TA MHz ±30 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT I, Pollution Degree 2.

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

TT-SI MHz Active Differential Probe

High Voltage Differential Probes HVD3605, HVD3206 HVD310x

User s Manual. Miniature Passive Probe. IM EN 3rd Edition

High Voltage Differential Probes HVD3605A, HVD3206A HVD310xA

MD 200A High voltage differential probe

Oscilloscope Probes and Accessories

Operator s Manual. PP022 Passive Probe

Operator s Manual. PP016 Passive Probe

Current clamps for AC current

9 Specifications. Specifications NOMINAL CHARACTERISTICS

Model: PR-55. High Voltage Oscilloscope Probe 10 kv, 40 MHz USER MANUAL

Digital Clamp Meter Model: &

DC MHZ PXI Differential Instrumentation Amplifier

Operator s Manual. PP017 and PP018 Passive Probes

E Series 9.00 (1/2) E series

Power Amplifier. Input Characteristics. SPECIFICATIONS NI PXIe-4610 Power Amplifier. Signal Range

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

N2792A and N2793A Differential Probes User s Guide

Quick Start RSDPB5000/RSDPB4000. High Voltage Differential Probe Series

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

Wide-band Models from DC to 100 MHz

Wide-band Models from DC to 100 MHz

NI PXI-2520 Specifications 80-Channel SPST Relay Module

Series OLS10KD 10kW HIGH VOLTAGE POWER SUPPLY

Keysight N2790A Differential Voltage Probe. User Guide

SA1500X. Operating Basics. Cautions DEVICE SPECIFICATIONS. High Impedance Active Probe

Series OLH10KD 10kW HIGH VOLTAGE POWER SUPPLIES

NI PXI-2521 Specifications 40-Channel DPST Relay Module

ISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

Wide-band Models from DC to 100 MHz

User s Manual Current Probe. IM E 2nd Edition IM E

NI SCXI Specifications

Pre-Amplifier SPA Series

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

N2790A Differential Voltage Probe

Keysight Technologies N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

Pulse Amplifier DIV 20 Instruction Manual 03/2016

For model: HVP-10R / HVP-18HF / HVP-28HF / HVP-39pro

1587/1577 Insulation Multimeters

Keysight Technologies N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes. Data Sheet

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

User s Manual Current Probe. IM E 2nd Edition. Yokogawa Electric Corporation

Keysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes. Data Sheet

INSTRUCTION MANUAL CLAMP ON PROBE

PRELIMINARY DATA. Fiber Optic Isolated Voltage Probe. GE50 Gate Explorer FEATURES

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

BENNING. CM7 Electrical Tester. Service Information

AC/DC Current Probe TCP0150 Datasheet

MDC4500-4B Amplifier/Combiner Data Sheet & User Manual. February Rev 0.95

Low Noise Variable Gain Low Frequency Voltage Amplifier

Schlöder GmbH - EMC Test and Measurement Systems Model #

SERIE E N. The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A.

8558A 8 1/2 Digit Multimeter

User s Manual Current Probe IM E. 8th Edition

USER MANUAL. Ultra-Low Noise High Voltage Amplifier WMA V to +150V output. 300µV rms output noise. 2mV output offset voltage

Current clamps for AC current

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

7051Plus / 5051Plus. Extended Specification

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

HITEK POWER OLH10K SERIES

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

10.00 (1/2) PAC series

CX1100 Series Current and Differential Sensors

AC/DC current clamps (1/2) E N series

AC/DC Current Oscilloscope Probe Model SL261

USER MANUAL. DC - 5MHz High Voltage Amplifier WMA V to +100V output. DC to -3dB large signal bandwidth. 1300V/µs slew rate typical

Low Noise Variable Gain Low Frequency Voltage Amplifier

INSTRUCTIONS MODEL AVC MONOCYCLE GENERATOR MODULE SERIAL NUMBER:

USER MANUAL. DC 13kHz High Voltage Amplifier WMA V to +175V output. Stable with all capacitive loads, generates no overshoot

HZ 115. Differential probe for oscilloscopes. C E IEC 1010 Cat III

User s Manual Current Probe IM E. 6th Edition

NI 2865A 0.3 A Matrix Cards for NI SwitchBlock

User s Guide. RP7000 Series Active Probe. Dec RIGOL Technologies, Inc.

AP034-OM-E Rev D ISSUED: January 2000 ²

Variable-Gain High Speed Current Amplifier

Transcription:

High Voltage Differential Probe Ord.-No: 880-102-501 Features: 2000 V rms Measurement Category I, 6000 V transient Overvoltage 1000 V CAT III 400 MHz Bandwidth < 1 % Deviation within Specified Operating Temperatures (0 C to +50 C) High CMRR 4 Mode Attenuation Useable with any 50 Ω Measuring Instrument BumbleBee is a 400 MHz, 2 kv Measurement Category I or 1 kv CAT III Differential High-Voltage Probe, that can be used with every instrument having 50 Ω Input Impedance. The probe is very effective at power device evaluation such as measurements in IGBT circuits used in the design of motor drives, switching power supplies and frequency converters. Especially 1700 V IGBT modules for inverters and converters. BumbleBee is also very effective at fast transient measurements with bandwidths of up to 400 MHz. Measurments at GaN and SiC modules as part of new semiconductor techniques profit from that in particular. It provides a 4 Mode Attenuation, which allows higher resolution measurements. The probe provides overload indicators for each input channel as well as for the output. That makes it easy to observe, that the differential probe is working in the specified range. The probe also provides an active offset correction in a range of ± 4 V, related to the output voltage, with a resolution of 15 Bit. These and many other functions can be remotely controlled with the free PC-Software "PMK Probe Control". The Software included in the scope of delivery of PMKs PS-02 and PS-03 Power Supplies. The intuitive grafical user interface makes all interactions with BumbleBee clear and easy.

Electrical Specifications (1) Attenuation Ratio (switchable) 50:1 100:1 250:1 500:1 Bandwidth (-3dB) Input Voltage 50 V 300 MHz 300 MHz 400 MHz 400 MHz Input Voltage 500 V n.a n.a 300 MHz 300 MHz Input Voltage 1000 V n.a n.a n.a 300 MHz Risetime (10 %- 90%) Input Voltage 50 V 1.2 ns 1.2 ns 875 ps 875 ps Input Voltage 500 V n.a n.a 1.2 ns 1.2 ns Input Voltage 1000 V n.a n.a n.a 1.2 ns Typical Noise (rms) (2) 55 mv 55 mv 75 mv 75 mv (referred to input) Typical Propagation Delay 12 ns Max. Input Voltage Measurement Category I Measurement Category III Pollution Degree 2 2000 V rms 6000 V transiente Overvoltage 1000 V CAT III Max. Differential Input Voltage ±200 V DC ± 400 V DC ± 1000 V DC ±2000 V DC (incl. AC peak) Common Mode Voltage ± 2000 V pk (± 1400 V rms) DC Gain Accuracy ± 0.7 % ± 0.7 % ± 0.35 % ± 0.35 % Offset Range (3) ± 4 V Offset Resolution (3) 15 Bit / minimum Step < 125 µv Offset Drift (3) 150 µv / C 150 µv / C 40 µv / C 40 µv / C Input Impedance Each Input to Ground Differential Input Impedance Input Coupling of the Measuring Instrument (4) 5 MΩ 4 pf 10 MΩ 2 pf 50 Ω Typical CMRR DC > 80 db 100 khz > 70 db 1 MHz > 62 db 3.2 MHz > 50 db (1) Measured at + 23 C environment connected to PS-02 Power Supply (2) Broadband Noise, Bandwidth 30 MHz (3) Referred to Output (4) Must be met to achieve best Performance and avoid Damage to the Probe 2

Voltage Derating Note that the max. input voltage rating of the probe decreases as the frequency of the applied signal increases. Amplitude AC rms [V] Sinus Amplitude AC rms [V]sinus 2000 1600 1200 800 400 Typical Voltage Derating BumbleBee 0 100K 1M 10M 100M 1G Frequency [Hz] Input Impedance Note that the input impedance of the probe decreases as the frequency of the applied signal increases. Z [Ohm] 100M 10M 1M 100K 10K 1K 100 Typical Input Impedance BumbleBee 10 10 100 1K 10K 100K 1M 10M 100M 1G Frequency [Hz] Mechanical Specifications Weight (Probe only) Cable Length Input Leads Length Input Connectors Output Connector 370 g 2 m 25 cm 2 x 4 mm (male) BNC (male) Environmental Specifications operating non- operating Altitude up to 2000 m up to 15000 m Temperature Range Probe Assembly 0 C to +50 C -20 C to +70 C Input Leads only -40 C to +85 C Maximum Relative Humidity 80 % RH for temperatures of up to +31 C, decreasing linearly to 40 % at +50 C. 3

Standard Scope of Delivery BumbleBee 890-880-105 Pair of 2-Footers (black) 890-880-116 4 mm Coupler f-f M80-102-501 Manual 890-880-115 Pair of Clamps, hook (black & red) 890-880-114 Pair of Clamps, jaws (black & red) 890-880-113 Pair of Clamps, rotating grip jaw (black & red) 890-880-109 Pair of Magnet Connectors 4 mm (black & red) 890-880-103 Pair of Probe Tip Adaptors 4 mm to 0.8 mm (black) 890-880-108 Pair of Alligator Clips, big (black & red) 890-880-111 Pair of Alligator Clips, small (black & red) 890-880-110 Pair of Spade Terminals, narrow (black & red) 890-880-107 Pair of Spade Terminals, wide (black & red) 890-880-106 Pair of Spring Tip Probes 4 mm (black & red) 890-520-900 Power Supply Cable 890-102-501 Probe 890-880-101 Set of 10 Contact Pins 0.64 mm 890-880-102 Set of 4 Spring Tips (fine) Note: All BumbleBee Models need a Power Supply to function. PMK recommends either a PS-02 or PS-03 Power Supply to ensure highest performance of BumbleBee as well as other PMK active probes. There is no Power Supply included in the standard scope of delivery. See 889-09V-PS2 and 889-09V-PS3 for more information on PMK Power Supplies available at http://www.pmk.de/en/products/ps02 Keyboard Layout - BumbleBee 4

Accessories for BumbleBee HV- Differential Probes 5

WEEE/ RoHS Directives (EC conformity marking) Your help and efforts are required to protect and keep clean our environment. Therefore return this electronic product at the end of its life either to the Service Department of PMK Mess- und Kommunikationstechnik GmbH or take care of separate WEEE collection and professional WEEE treatment yourself. Do not dispose as unsorted municipal waste. EC Directives: WEEE Directive 2002/96/EC Waste Electrical and Electronic Equipment RoHS Directive 2002/95/EC Restriction of the use of certain Hazardous Substances in Electrical and Electronic Equipment Safety Information To avoid personal injury and to prevent fire or damage to this product or products connected to it, review and comply with the safety informations stated in the manual before using this product. Be aware that if you use this probe assembly in a manner not specified the protection this product provides may be impaired. Only Qualified Personnel should use this Probe Assembly. Manufacturer PMK Mess- und Kommunikationstechnik GmbH Königsteiner Str. 98 65812 Bad Soden am Taunus, Germany Internet: www.pmk.de Tel: +49 (0) 6196 5927-930 E-Mail: sales@pmk.de Fax: +49 (0) 6196 5927-939 This datasheet supersedes all previously published material. Specifications that are not marked as guaranteed are published as general information to the user. The specifications stated are achieved with a PMK Power Supply and can vary, if BumbleBee is powered by another source. The instrument should have warmed up for at least 20 minutes and the environmental conditions must not exceed the specified limits of the probe. We recommend a calibration period of 1 year or less. Note that specifications are subject to change without notice. Revision P February 2017 6