Agilent E4980A Precision LCR Meter. Dielectric Constant Measurement Program Operation Manual

Similar documents
IMD Measurement Wizard for the E5072A ENA Series Network Analyzer Operation Manual. Agilent Technologies June 2012

Keysight Technologies Solutions for Measuring Permittivity and Permeability with LCR Meters and Impedance Analyzers.

Agilent Solutions for Measuring Permittivity and Permeability with LCR Meters and Impedance Analyzers. Application Note

Getting Started. Spectra Acquisition Tutorial

Advanced Test Equipment Rentals ATEC (2832)

DMR Radio Authorization Operation Guide

Guardian Pedestrian Signal Installation Manual

GM8036 Laser Sweep Optical Spectrum Analyzer. Programming Guide

Keysight Technologies Solutions for Measuring Permittivity and Permeability with LCR Meters and Impedance Analyzers.

VT1586A Rack Mount Terminal Panel Installation and User s Manual

Agilent ParBERT Measurement Software. Fast Eye Mask Measurement User Guide

Keysight Technologies Accessories Catalog for Impedance Measurements. Catalog

Using the S5U13781R01C100 Shield Graphics Library with Atmel Studio

Agilent MOI for MIPI D-PHY Conformance Tests Revision 1.00 Dec-1, 2011

Keysight Technologies Accessories Selection Guide For Impedance Measurements. Selection Guide

UM DALI getting started guide. Document information

Flat Sample Holder Part Number

Unirac Flat Flashing INSTALLATION MANUAL

AN NFC, PN533, demo board. Application note COMPANY PUBLIC. Rev July Document information

AN PR533 USB stick - Evaluation board. Application note COMPANY PUBLIC. Rev May Document information

AN12082 Capacitive Touch Sensor Design

Keysight Technologies Accessories Catalog for Impedance Measurements. Catalog

UM DALI getting started guide. Document information

AN4014 Application Note Adjustable LED blinking frequency using a potentiometer and STM8SVLDISCOVERY Application overview

Pin Tool. Assembly Guide. For Research Use Only. Not for use in diagnostic procedures. Original Instructions

GPS140 DOS Application User s Manual Version 1.0.x

GW3-TRBO Affiliation Software Version 2.15 Module Book

ACC-6SMRP2U Data Sheet

LD2342 USWM V1.6. LD2342 V1.4 Page 1 of 18

PN7150 Raspberry Pi SBC Kit Quick Start Guide

Transmitter. User Manual. Firmware version 1.0 and greater

Large-Signal S-Parameter Simulation

UM10950 Start-up Guide for FRDM-KW41Z Evaluation Board Bluetooth Paring example with NTAG I²C plus Rev February

Agilent Technologies 355C, D, E, F VHF Attenuators. Operating and Service Manual

Agilent N7509A Waveform Generation Toolbox Application Program

FRYCORDER Power Cord Burn-in Generator

Sheet Metal Design Guidelines

Installation and Quick Start Guide

The Frequency Divider component produces an output that is the clock input divided by the specified value.

BVS RHINO PC INTERFACE SOFTWARE

Keysight MOI for MIPI D-PHY Conformance Tests Revision Oct, 2014

Internal B-EN Rev A. User Guide. Leaf Aptus.

IX Feb Operation Guide. Sequence Creation and Control Software SD011-PCR-LE. Wavy for PCR-LE. Ver. 5.5x

Agilent Accessories Selection Guide For Impedance Measurements. December 2008

AT15291: Migrating QTouch Designs from SAM D MCUs to SAM C MCUs. Scope. Features. QTouch APPLICATION NOTE

DATASHEET 4D SYSTEMS. Arduino Display Module Pack TURNING TECHNOLOGY INTO ART. Featuring a 2.4 Display Module ulcd-24-ptu-ar

Grundlagen der Impedanzmessung

USB-PWM10. User s Manual

EOS Utility Instruction Manual

UM UBA2024 application development tool. Document information

Field Device Manager Express

IB Nov User s Manual. KFM Series Application Software. FCTester. Ver. 1.1

OM29110 NFC's SBC Interface Boards User Manual. Rev May

XLR PRO Radio Frequency (RF) Modem. Getting Started Guide

User Guide. Version 1.4. Copyright Favor Software. Revised:

CPL-WB-00C2. Wide band directional coupler with ISO port. Features. Applications. Description. Benefits

GenWatch3 GW_Affiliation Software Version 2.10 Module Book

Large-Signal S-Parameter Simulation

RAZER GOLIATHUS CHROMA

DATA SHEET. E4982A LCR Meter. 1 MHz to 300 MHz/500 MHz/1 GHz/3 GHz

UIO Digital I/Os & DAQ Board User Manual

AN4313 Application note

Agilent MOI for MIPI M-PHY Conformance Tests Revision Mar 2014

ESDARF01-1BF4. ESD protection for AM and FM antenna. Features. Applications. Description. Complies with the following standards

Aimetis Outdoor Object Tracker. 2.0 User Guide

HP 86290B RF PLUG-IN GHz HEWLETT PACKARD

A-16D A-Net Distributor

Model 4105 Horn Antenna

User Manual Solenoid Controller BI-SC1001

PWRVIEW Online Help *P * ZZZ

Accessories Selection Guide For Impedance Measurements. April 2005

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

Model 3101, 3102 and 3103 Conical Log-Spiral Antennas

Digi-Stop. Installation & Operation

DPM Kit DK-1. Using the DPM Kit

Oracle Real-Time Scheduler

Hytera. PD41X Patrol Management System. Installation and Configuration Guide

Sheet Metal Design Guidelines

EchoSonic II Ultrasonic Level Transmitter LU27 Series Quick Start NEMA 4X Enclosure

Vision Sensor FH Series. Vision System. Operation Manual for Sysmac Studio FH-1 FH-1 - FH-2 FH-2 - FH-3 FH-3 - FH-5 FH-5 - Z343-E1-09

EchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure

Agilent N2902A 9000 Series Oscilloscope Rack Mount Kit

Dual 4-bit static shift register

HEF4014B. 1. General description. 2. Features and benefits. 3. Applications. 4. Ordering information. 8-bit static shift register

The ideal K-12 science microscope solution. User Guide. for use with the Nova5000

SRT Marine Technology. LD2342 V1.4 Page 1 of 22

User s Guide for: What is a SeaSonde?

PN7120 NFC Controller SBC Kit User Manual

W H I T E P A P E R. EMC Countermeasure Techniques in Hardware. Introduction

TDA W hi-fi audio amplifier. Features. Description

305 Stimulus Isolator. Description

g GETTING STARTED D PC System Requirements Computer: Pentium 90 MHz processor or equivalent.

UM Slim proximity touch sensor demo board OM Document information

User Guide. Version 1.2. Copyright Favor Software. Revised:

Agilent Technologies 8494A/B, 8495A/B, and 8496A/B Attenuators. Operating and Service Manual

Passive Component LCR Meter

USBULC6-2N4. Ultralow capacitance ESD protection for high speed interface. Features. Applications. Description. Benefits

Component Test. All Test Equipment in this category can be linked to PC. Comparison Function. Graphic Scan Function Bin Sorting Function

AN3332 Application note

User Manual January Opticom Infrared System RC790 Remote Coding Unit

Transcription:

Agilent E4980A Precision LCR Meter Dielectric Constant Measurement Program Operation Manual

Notices The information contained in this document is subject to change without notice. This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Agilent Technologies. Microsoft, MS-DOS, Windows, Visual C++, Visual Basic, VBA and Excel are registered trademarks of Microsoft Corporation. Java is registered trademark of Sum Microsystems Corporation. Copyright 2008 Agilent Technologies Sample Program The customer shall have the personal, non-transferable rights to use, copy, or modify SAMPLE PROGRAMS in this manual for the customer s internal operations. The customer shall use the SAMPLE PROGRAMS solely and exclusively for their own purpose and shall not license, lease, market, or distribute the SAMPLE PROGRAMS or modification of any part thereof. Agilent Technologies shall not be liable for the quality, performance, or behavior of the SAMPLE PROGRAMS. Agilent Technologies especially disclaims any responsibility for the operation of the SAMPLE PROGRAMS to be uninterrupted or error-free. The SAMPLE PROGRAMS are provided AS IS. AGILENT TECHNOLOGIES DISCLAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Agilent Technologies shall not be liable for any infringement of any patent, trademark, copyright, or other proprietary right by the SAMPLE PROGRAMS or their use. Agilent Technologies does not warrant that the SAMPLE PROGRAMS are free from infringements of such rights of third parties. However, Agilent Technologies will not knowingly infringe or deliver software that infringes the patent, trademark, copyright, or other proprietary right of a third party.

1. General information Overview of the program The E4980A Dielectric Constant Measurement Program assists dielectric constants measurement using the Agilent E4980A Precision LCR Meter and the 16451B Dielectric Test Fixture. This program (a VBA macro for Microsoft Excel ) provides step-by-step instruction for the measurement. It calculates dielectric constants from capacitance and dissipation factor measured by the E4980A and the 16451B. Following parameters can be calculated and listed on the spreadsheet of Microsoft Excel. Program Description Program title File Name Revision Dielectric Constant Measurement Program E4980A_Permittivity_0102.xls Rev.01.02 Supported models and firmware Models E4980A Precision LCR Meter Firmware Rev.1.00 or later Required equipments 16451B Dielectric Test Fixture External controller (external computer such as PC) * Agilent I/O Libraries Suite 14 or higher needs to be installed. Connection cable (USB cable furnished with the E4980A or GPIB cable) 1

2. Boot/Exit the program 2.1. Connecting the instruments and controller Connect the E4980A, 16451B, and the controller as shown below. Note: The Agilent I/O Libraries Suite needs to be installed in the external controller in advance. Use Agilent I/O Libraries Suite 14 or higher. For further information on I/O Libraries Suite, see the Agilent I/O Libraries Suite manual. Agilent I/O Libraries Suite may not be available for certain external controllers or OS versions. For further details, refer to the help guidance for Agilent I/O Libraries Suite. 2.2. Boot the program Open E4980A_Permittivity_xxxx.xls file. Since this file contains macros, a message box shown below appears when opening the file. Click Enable Macros to boot the program. 2.3. Exit the program Close E4980A_Permittivity_xxxx.xls file. 2

3. Setting the GPIB address or USB ID In order to control the E4980A from the external controller by using the program, GPIB address or USB ID must be set in the macro. The procedures are described below. 3.1. Open Visual Basic Editor. Tools Macro Visual Basic Editor Open the module named Module1 which is stored in Modules folder. Then, the display will be as follows. 3

3.2. Modifying the GPIB address or USB ID 3.2.1. When using GPIB cable for connecting the controller and the E4980A: Modify the code "GPIB0::17::INSTR". In other words, change the number "17", which indicates the GPIB address of the E4980A employed, to the appropriate number for your E4980A. Factory-shipped setting of the E4980A s GPIB address is 17. For the details about GPIB address of the E4980A, refer to Chapter 5 System Configurations of the E4980A User s Guide. 3.2.2. When using USB cable for connecting the controller and the E4980A: Modify the code "USB0::2391::2313::LP10000000::0::INSTR". In other words, change "LP10000000" to the serial number of your E4980A. Serial number can be checked on SYSTEM INFO page of the E4980A (see Chapter 5 System Configurations of the E4980A User s Guide) or on the rear panel of the E4980A. 4

4. Measurement procedure This section describes how to use the program. For the detail of each measurement method available with the 16451B, please refer to Chapter 3 Operation of the 16451B Operation and Service Manual. 4.1. Contacting Electrode Method 1. Boot the program and modify GPIB address or USB ID as shown in section 2 and 3. 2. Change the sheet to Contacting Electrode Method. 3. Change the Guarded/Guard Electrode to the appropriate one (Electrode-A, B, C or D). The details about how to change the electrode are described in the paragraph Changing the Guarded/Guard Electrode in Chapter 3 of the 16451B Operation and Service Manual. 4. Place the 16451B in vertical position as shown below. Then, perform a rough adjustment. For the details, refer to the paragraph Rough Adjustment to Make Electrodes Parallel in Chapter 3 of the 16451B Operation and Service Manual. Vertical Position or the 16451B 5. Fill the entry fields in the spreadsheet, which are indicated by yellow cells. A. Connection Interface Choose GPIB or USB based on the interface used. 5

B. Select the Electrode Choose appropriate one among A, B, C, or D. C. OSC Level Set the oscillator voltage level of the E4980A. Available voltage level is 0 Vrms to 2 Vrms (Standard model) or 0 Vrms to 20 Vrms (Option 001) D. OPEN/SHORT Correction Choose the correction method. Following two methods are available. Correction based on all frequency points Correction based on specified frequency points For the details of these methods, please refer to CORRECTION page in Chapter 4 of the E4980A User s Guide. Note: When you choose Correction based on specified frequency points, the correction is performed at frequency points input in Frequency field. E. Thickness Input the thickness of the MUT (Material Under Test). F. Diameter (Fill this field only when the Electrode-C or -D is used.) Input the diameter of the guarded thin film electrode. G. Parameter Choose measurement parameters. Following parameters are available. r - tan, r - tan r - r H. Frequency Set the frequency at which the dielectric constants are measured. 6. Click Cable length correction button. The subsequent step is different depending on the electrode used in the measurement. 6-1. When the Electrode-A or -B is used When the Cable length correction button is clicked, the cable length correction and measurement settings are performed after presetting the E4980A.When they are completed, the following message box appears. 6

After setting the 16451B OPEN condition as shown in the figure below, press OK. This step performs the OPEN correction for electrode adjustment. OPEN condition of the 16451B When the OPEN correction is completed, the following message box appears. After setting the 16451B SHORT condition as shown below, press OK to perform the SHORT correction for electrode adjustment. A message Done is shown in the blue area below the Cable length correction button when this step is completed. SHORT condition of the 16451B 7

6-2. When the Electrode-C or -D is used When the Cable length correction button is clicked, the cable length correction and measurement settings are performed after presetting the E4980A. A message Done is shown in the blue area below the Cable length correction button when this step is completed. 7. Click Electrode adjustment button. The following message box appears. Note: This step is necessary only when the Electrode-A or -B is used. When using the Electrode-C or D, skip the step 7 and go to the step 8. Click OK in this message box. Then, the following message box appears (this is an example when the Electrode-A is used). Adjust the Unguarded electrode by turning the three adjustment screws until the measured Cp value falls within the limit. The details about the adjustment are described in the paragraph Accurate Adjustment to Make Electrodes Parallel in Chapter 3 of the 16451B Operation and Service Manual. When the Cp value falls within the limit, click OK in the dialog box. The measured Cp value and the Pass/Fail result are displayed on the spreadsheet as follows. 8

8. Click OPEN/SHORT correction button. The following message box appears. After setting the 16451B OPEN condition as shown in the step 6, press OK to perform the OPEN correction. When the OPEN correction is completed, the following message box appears. After setting the 16451B SHORT condition as shown below, press OK to perform the SHORT correction. SHORT condition of the 16451B For the Electrode-A or -B For the Electrode-C or -D When the SHORT correction is completed, Done message is displayed in the blue area below the OPEN/SHORT correction button. 9

9. Click Measure and calculate button. The following message box appears. By clicking OK, the measurement is performed and the results are displayed in the spreadsheet. 10

4.2. Non-contacting Electrode Method 1. Boot the program and modify GPIB address or USB ID as shown in section 2 and 3. 2. Change the sheet to Non-contacting Electrode Method. 3. Change the Guarded/Guard Electrode to the appropriate one (Electrode-A or B). The details about how to change the electrode are described in the paragraph Changing the Guarded/Guard Electrode in Chapter 3 of the 16451B Operation and Service Manual. 4. Place the 16451B in vertical position as shown in the step 4 of the paragraph 4.1 Contacting Electrode Method. Then, perform a rough adjustment. For the details, refer to the paragraph Rough Adjustment to Make Electrodes Parallel in Chapter 3 of the 16451B Operation and Service Manual. 5. Fill the entry fields in the spreadsheet, which are indicated by yellow cells. A. Connection Interface Choose GPIB or USB based on the interface used. B. Select the Electrode Choose appropriate one from A or B. C. OSC Level Set the oscillator voltage level of the E4980A. Available voltage level is 0 Vrms to 2 Vrms (Standard model) or 0 Vrms to 20 Vrms (Option 001) D. OPEN/SHORT Correction Choose the correction method. Following two methods are available. Correction based on all frequency points Correction based on specified frequency points 11

For the details of these methods, please refer to CORRECTION page in Chapter 4 of the E4980A User s Guide. Note: When you choose Correction based on specified frequency points, the correction is performed at frequency points input in Frequency field. E. Thickness Input the thickness of the MUT (Material Under Test). F. Distance of Electrode Gap Input the distance between the Guarded/Guard Electrode and the Unguarded Electrode. The unit should be millimeter. G. Parameter Choose measurement parameters. Following parameters are available. r - tan, r - tan r - r H. Frequency Set the frequency at which the dielectric constants are measured. 6. Click Cable length correction button. Then, the cable length correction and measurement settings are performed after presetting the E4980A.When they are completed, the following message box appears. After setting the 16451B OPEN condition as shown in the figure below, press OK. This step performs the OPEN correction for electrode adjustment. OPEN condition of the 16451B 12

When the above operation is completed, the following message box appears. After setting the 16451B SHORT condition as shown below, press OK to perform the SHORT correction for electrode adjustment. A message Done is shown in the blue area below the Cable length correction button when this step is completed. SHORT condition of the 16451B 7. Click Electrode adjustment button. The following message box appears. Click OK in this message box. Then, the following message box appears (this is an example when the Electrode-A is used). Adjust the Unguarded electrode by turning the three adjustment screws until the measured Cs value falls within the limit. The details about the adjustment are 13

described in the paragraph Accurate Adjustment to Make Electrodes Parallel in Chapter 3 of the 16451B Operation and Service Manual. When the Cs value still falls within the limit at horizontal position, click OK in the dialog box. The measured Cs value and the Pass/Fail result are displayed on the spreadsheet as follows. 8. Click OPEN/SHORT correction button. The following message box appears. After setting the 16451B OPEN condition as shown in the step 6, press OK. The OPEN correction is performed. When the OPEN correction is completed, the following message box appears. After setting the 16451B SHORT condition as shown in the step 6, press OK. The SHORT correction is then performed. When the SHORT correction is completed, Done message is displayed below the OPEN/SHORT correction button. 9. Click Measure and calculate button. The following message box appears. Adjust the distance of the electrodes by turning the knob of the micrometer. The 14

distance should be the same value as that entered in the Distance of Electrode Gap (Tg) [mm] field. When ready, click OK button. The following message box appears. Insert the MUT between the electrodes and click OK button. This step performs capacitance and dissipation factor measurement with the MUT inserted. When this step is finished, the following message box appears. Remove the MUT and click OK button. The capacitance and dissipation factor measurements without the MUT inserted are performed. After the measurement, the calculated dielectric constants are automatically displayed in the sheet. 15

Revision Control Revision Date Description of change 01.00 01.01 01.02 2008/08/06 2011/12/20 2012/03/09 Initial revision Fixed bug on tanδ calculation Changed timeout value 16