ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Similar documents
DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Power supply CP-E 24/20.0

Type CP-S, CP-C & CP-A Switch mode

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Power supply CP-E 24/2.5

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

QUINT-PS/ 3AC/24DC/10

CP-T range Product group picture

Power supply CP-D 24/4.2 Primary switch mode power supply

Power Supplies 3. SDN-C Compact DIN Rail Series

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

Power supply CP-D 12/2.1

Power supply CP-D 24/1.3

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

MINI-PS AC/24DC/1.3

SPECIFICATION. Online UPS 3000VA

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

Output Voltage* (nom.)(adjustable)

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

Watts HCP Series

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

CP-E range Benefits and advantages

CCH400 & CCH600 Series

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

CP-T range Benefits and advantages

QUINT-PS AC/24DC/40

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Switching Power Supply Type SPP1 60W Enclosed type

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

POWERBOX Defense Line 1200 DBA Series 1200W AC/DC Conduction Cooled Manual. 2. Features. 1. Introduction

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

Power supply CP-E 24/0.75

CB Scheme UL508 UL ATEX II3G

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-E 24/2.5

LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies.

Resilient 3000 EP3000AC48IN Rectifier 3000W Output at 48 58Vdc

PDAM500 Series 500W Power Supply

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply

Primary switch mode power supplies Product group picture

LDC480 Series is a single phase, extremely compact Power Supply with active PFC specially designed for space sensitive and demanding applications.

Power supply CP-T 24/10.0 Primary switch mode power supply

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

TB65 65W Single Output Test and Measurement/Industrial Series

QUINT-PS/ 3AC/24DC/40

LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications.

SPECIFICATIONS. Input Output Approvals

MINI-PS AC/2X15DC/1

Switching power supplies CP range, Linear power supplies CP-L range. Content

Output Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W

General. Environmental. EMC & Safety

Power supply CP-T 48/5.0 Primary switch mode power supply

C B. Models. Models 2MOPP

Electrical Specifications

X Series Data Sheet 375, 500 Watt AC-DC and DC-DC DIN-Rail Converters

AC/DC Power Supply Series APPLICATION NOTE

solo Ultra-high efficiency 1U size Xsolo Single Output Power Supply 500W W 2 FEATURES APPLICATIONS INCLUDE

RSP-2400 series. 2400W Power Supply with Single Output. File Name:RSP-2400-SPEC Sicherheit ID

TRC ELECTRONICS, INC AC/DC Power Supply Built-In Fan PFC 2400W MEAN WELL RSP-2400 Series

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 115VAC to 78% at 90VAC)

TRC ELECTRONICS, INC AC/DC Power Supply Built-In Fan PFC 3000W MEAN WELL RSP-3000 Series

TRC ELECTRONICS, INC

Industrial Serie +600S

ECC100 Series. -40 ºC to +75 ºC Operation. 100 W - Baseplate Cooled. High Efficiency Resonant Topology. Screw Terminals Available.

POWERBOX Defense Line 1200 DBA Series 1200W AC/DC Conduction Cooled. Preliminary

RSD-30 series. 30W Reliable Railway DC-DC Converter. (reinforced isolation) File Name:RSD-30-SPEC

SM2000 TECHNICAL DESCRIPTION

CLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby

DRC-100 series. 100W Single Output with Battery Charger (UPS Function) File Name:DRC-100-SPEC Sicherheit ID

Compliance. Safety Approvals USA Canada Europe. Isolation: General. Dimensions. AC Input CN1 Output CN2 Optional CN3. Weight

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

60W Reliable Railway DC-DC Converter. RSD-60 series. File Name:RSD-60-SPEC

QUINT-PS-24DC/24DC/10

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms. 100mVp-p 200mVp-p 120mVp-p 240mVp-p -25 C - 70 C 48Vout 240mVp-p

AC/DC Power Supply Series APPLICATION NOTE

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

RSP-3000 series. 3000W Power Supply with Single Output. File Name:RSP-3000-SPEC Sicherheit ID

Electrical Specifications. Adjustment range Main output ± 5% Total regulation (line and load) ± 2.0% ± 5.0% Turn-on 120 Vac Input 2.0 s max.

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

1500W Programmable Single Output AK V. 48V Rated Current. 31.3A Current Range 100A. 0~31.3A Rated Power 0~100A 1500W

Electrical Specifications

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

300W Railway Single Output DC-DC Converter

RSP-1500 series. 1500W Single Output Power Supply. File Name:RSP-1500-SPEC Sicherheit ID

LPS TRC ELECTRONICS, INC

RSP-1500 series. 1500W Single Output Power Supply

1000 ~ 3000W 1U Distributed Power System RCP-1U Rack System

60W Reliable Railway DC-DC Converter. RSD-60 series. File Name:RSD-60-SPEC

RSP-1500 series. 1500W Single Output Power Supply. File Name:RSP-1500-SPEC Sicherheit ID

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Model Vnom Power Description Set Point Dynamic Vtrim Imax Remote Power (V) (W) Adjust Range (V) Range (V) (A) Sense Good

Transcription:

ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000 000 hours Built in output series diode Temperature compensated battery charging Wide output adjustment range Efficiency 82 90% Operating temperature 40 C +70 C (see derating) EMC EN55022B (telecom) MULTI PURPOSE APPLICATIONS (EXAMPLES) (A) (B) (C) (D) Battery back-up systems Temperature compensated charging Low voltage disconnecting unit Special features with external control: - Boost charging - Battery test possibility - Shut down by external 4-15V voltage - Controllable output voltage Redundant n+1 systems with built in series diode and module fail Series connection ± s Sales & R&D Martinkyläntie 43, FI-01720 VANTAA, Tel. +358 10 2890 700 E-mail marketing@powernet.fi, service@powernet.fi Internet www.powernet.fi

POWER SUPPLY MODELS DIN/WALL Type *) xy Available xy selection codes (others on request) Input Adjustment Current Power Mechanical Dimensions (W x H x D) Note ADC56xy xy = 21, 23 90 264 VAC 12 VDC 10.5...15 VDC 5 A 60 W 51 x 121 x 81 mm ADC50xy xy = 23 230/115 VAC 12 VDC 9...15 VDC 10 A 120 W 66 x 148 x 113 mm ADC53xy xy = 23 230/115 VAC 12 VDC 9...15 VDC 20/18 A 240 W 75 x 173 x 122 mm **) ***) ADC53xyP On request 230/115 VAC 12 VDC 9...15 VDC 20/18 A 240 W 75 x 173 x 122 mm ***) ADC57xy xy = 21, 23 90 264 VAC 24 VDC 21...29 VDC 2.5 A 60 W 51 x 121 x 81 mm ADC51xy xy = 21, 23 230/115 VAC 24 VDC 21...29 VDC 5 A 120 W 66 x 148 x 113 mm ADC54xy xy = 21, 23 230/115 VAC 24 VDC 21...29 VDC 10 A 240 W 75 x 173 x 122 mm **) ADC54xyP On request 230/115 VAC 24 VDC 21...29 VDC 10 A 240 W 75 x 173 x 122 mm ADC59xy On request 90 264 VAC 36 VDC 33...44 VDC 1.7 A 60 W 51 x 121 x 81 mm ***) ADC58xy xy = 23 90 264 VAC 48 VDC 45...58 VDC 1.25 A 60 W 51 x 121 x 81 mm ADC52xy On request 230/115 VAC 48 VDC 45...58 VDC 2.5 A 120 W 66 x 148 x 113 mm ADC55xy xy = 23 230/115 VAC 48 VDC 45...58 VDC 5 A 240 W 75 x 173 x 122 mm **) ADC55xyP On request 230/115 VAC 48 VDC 45...58 VDC 5 A 240 W 75 x 173 x 122 mm 8750230A Finger protected power cord for ADC5000-series models RECTIFIER MODELS DIN/WALL, FLOAT OUTPUT VOLTAGE LEVEL (See Application (A) page 1) Type *) xy Available xy selection codes (others on request) Input Adjustment Current Power Mechanical Dimensions (W x H x D) Note ADC56xy xy = 83 90 264 VAC 13.7 VDC 10.5...15 VDC 4.4 A 60 W 51 x 121 x 81 mm ADC50xy xy = 83 230/115 VAC 13.7 VDC 9...15 VDC 10 A 137 W 66 x 148 x 113 mm ADC53xy xy = 83 230/115 VAC 13.7 VDC 9...15 VDC 20/18 A 274 W 75 x 173 x 122 mm **) ***) ADC53xyP On request 230/115 VAC 13.7 VDC 9...15 VDC 20/18 A 274 W 75 x 173 x 122 mm ***) ADC57xy xy = 83 90 264 VAC 27.4 VDC 21...29 VDC 2.2 A 60 W 51 x 121 x 81 mm ADC51xy xy = 83 230/115 VAC 27.4 VDC 21...29 VDC 5 A 137 W 66 x 148 x 113 mm ADC54xy xy = 83 230/115 VAC 27.4 VDC 21...29 VDC 10 A 274 W 75 x 173 x 122 mm **) ADC54xyP xy = 83 230/115 VAC 27.4 VDC 21...29 VDC 10 A 274 W 75 x 173 x 122 mm ADC59xy On request 90 264 VAC 41.4 VDC 33...44 VDC 1.5 A 60 W 51 x 121 x 81 mm ***) ADC58xy xy = 83 90 264 VAC 54.8 VDC 45...58 VDC 1.1 A 60 W 51 x 121 x 81 mm ADC52xy On request 230/115 VAC 54.8 VDC 45...58 VDC 2.5 A 137 W 66 x 148 x 113 mm ADC55xy xy = 83 230/115 VAC 54.8 VDC 45...58 VDC 5 A 274 W 75 x 173 x 122 mm **) ADC55xyP xy = 93 230/115 VAC 54.8 VDC 45...58 VDC 5 A 274 W 75 x 173 x 122 mm 8750230A Finger protected power cord for ADC5000-series models *) y selection code: Standard features: All models 1 = Module fail alarm relay + over voltage protection (OVP), 3 = series diode + Module fail alarm relay + OVP Optional features: 125/250W models 0 = Alarm relay + Shut down, 2 = series diode + Alarm relay + Shut down, (No OVP) 125/250W rectifiers 4 = remote control for battery test + alarm relay + OVP, 5 = remote control for battery test + alarm relay + OVP + series diode Marking plate sticker See type number and serial number details here Letter P models include passive power factor correction coil **) Marked model does not comply with EN61000-3-2 harmonics standard. These can be used in following applications: the unit is not directly connected to the public mains network, or if the unit is installed in a professional equipment with a total rated power greater than 1kW, or if the input current of the equipment is greater than 16A per phase ***) Marked models are not UL508 listed, 12V/ 20A model max current with series diode 18A Optional: ADC5000 R-versions for rugged environment, Type number for example ADC5183R

SPECIFICATION INPUT Input voltage Frequency 60W 125W 250W 12V 24V 36V 48V 12V 24V 48V 12V 24V 48V 90...264 VAC / 85 200 VDC (DC input is not UL60950-1 approved) 45...65Hz 94...132 VAC or 184...264 VAC selectable by switch Input current, 100% load, 230VAC 0.8A 1.4A ADC5xxx 2.5A, ADC5xxxP 1.9A Input current, 100% load, 115VAC 1.4A 2.4A ADC5xxx 4.5A Efficiency, typical (230 VAC, 100% load) >82% >83% >83% >84% >85% >88% >89% >85% >89% >90% Isolation Input / ground 1500 VAC RMS 50Hz, 1min, Input / output 3000 VAC RMS 50Hz, 1min. / ground 500 VDC Inrush current (25Cº), 230VAC <25A <5ms <45A <5ms <35A <5ms Inrush current (25Cº), 115VAC <12A <10ms <22A <10ms <17A <10ms Input fuse T3.15A, high breaking T4A, high breaking T6.3A, High breaking Overvoltage transient protection VDR 300VAC 77J OUTPUT voltage, PSU models (50% load) 12V 24V 36V 48V 12V 24V 48V 12V 24V 48V voltage, rectifiers (50% load) 13.7V 27.4V 41.1V 54.8V 13.7V 27.4V 54.8V 13.7V 27.4V 54.8V adjustment (typical) 10,5...15V 21...29V 33 44V 45...58V 9...15V 21...29V 45...58V 9...15V 21...29V 45...58V Ripple voltage (20Hz...300kHz, 25 C) <15mVrms <15mVrms <15mVrms <15mVrms <15mVrms <15mVrms <15mVrms Load regulation (without series diode) <1.0 % <0.5 % <0.5 % <0.5 % <1.0 % <0.5 % <0.5 % <1.0 % <0.5 % <0.5 % Line regulation < 0.15 %, Uinmin...Uinmax Temperature coefficient < 0.02 % / C Current limit (refer curve page 5) <8A <4A <3A <2A <11A <6A <3A <22/20A <11A <6A Short circuit current (refer curve page 5) <14A <9A <8A <6A <16A <10A <6A <27A <14A <9A Hold-up time (230V, 100% load) >50ms >50ms 50ms 50ms >20ms >20ms >20ms >20ms >20ms >20ms ALARMS AND INDICATIONS OK Power Fail relay alarm Green LED Relay contacts Normally Open and Closed, Activated at AC fail and module fail cases Relay contact rating: 24VDC/0.3A or 30VAC/0.5A Undervoltage alarm threshold level 10.2V ±0.5V 20V ±1V 28V ±1V 41V ±2V 8.3V ±0.5V 19V ±1V 39V ±2V 8.3V ±0.5V 19V ±1V 39V ±2V overvoltage protection level 16V 30,5V 46V 61V 16V 31V 60V 16V 31V 60V Series diode at output can be equipped with internal series diode, diode in 125/250W models, FET circuit in 60W models Optional Shutdown Shutdown by external voltage 4 15VDC to RC pin Optional battery test control Float charge voltage can be reduced by external 4 15VDC control to allow battery test by using external measurement circuit Temperature compensation (rectifiers) By external NTC resistor 2.2 kohm, included in rectifier models delivery MECHANICAL Dimensions (w x h x d) 51 x 121 x 81 mm 66 x 148 x 113 mm 75 x 173 x 122 mm Can be installed both horizontally and vertically (3 different installation choices) Weight 360 g 840 g ADC5xxx 1.3kg, ADC5xxxP 1.5kg Enclosure Connectors ENVIRONMENTAL Storage temperature Operation temperature Cooling Humidity Steel / aluminium enclosure IP20 Removable 2.5 mm² screw terminals -40 C...+85 C -40 C...+70 C, full power up to +55C (expect 250W/12VDC models), See derating curves Natural convection 85% RH 95% RH coated PCBs in R-versions Do not energize while condensation is present. Shock and vibration ETS 300 019-2-4, class 4M5, Vibration, sin, IEC60068-2-6, 2gn 9-200m/s 2, Vibration, broad-band random, IEC60068-2-64 STANDARDS, APPROVALS Safety standards EN 60950-1 class 1 including CB certificate and U.S. deviations according to UL60950-1 class 1 UL508 industrial control equipment (not all models, refer page 2) EMC emissions EN61000-6-3 EMC Immunity EN61000-6-2 EN 55022 class B conducted and radiated emissions EN61000-3-2 harmonics (not 250W models without P in type number) EN61000-3-3 Flickering EN 61000-4-2 Electrostatic Discharge EN 61000-4-3 Radiated Immunity EN 61000-4-4 Fast Transients EN 61000-4-5 Surge EN 61000-4-6 Conducted Immunity EN 61000-4-8 Power frequency magnetic field immunity EN 61000-4-11 dips and interruptions, immunity Approvals CE-marking, CB certificate EN60950-1/UL60950-1, UL508 cul listing (not all models, refer page 2)

PIN CONFIGURATION 60W MODELS 3 INPUT L N 1 OUT ADJ. TEMP COMP OFF ALARM COM NO NC OUT + - 8 1 ON INPUT CONNECTOR OUTPUT CONNECTOR 1: Protective Earth 1: 2: N (+ if used at DC network) 2: + 3: L (- if used at DC network) 3: Not in use (Y selection code 1 or 3) OR Remote control input in shut down models (Y selection code 0 or 2) 4,5: Temperature compensation NTC sensor 6: Alarm relay, normally closed (relay not energized) 7: Alarm relay, normally open (relay not energized) 8: Alarm relay, common Use 60/70 or 75 C copper (CU) wire only. The recommended terminal tightening torque is 0.5Nm. PIN CONFIGURATION 125W MODELS INPUT CONNECTOR OUTPUT CONNECTOR 1: Protective Earth 1: 2: N 2: + 3: L 3,4: Temperature compensation NTC sensor 5: Alarm relay, normally closed (relay not energized) 6: Alarm relay, normally open (relay not energized) 7: Alarm relay, common 8: Not in use (Y selection code 1 or 3) OR Remote control input in shut down (Y=0 or 2) or battery test models (Y=4 or 5) Use 60/70 or 75 C copper (CU) wire only. The recommended terminal tightening torque is 0.5Nm. PIN CONFIGURATION 250W MODELS INPUT CONNECTOR OUTPUT CONNECTOR 1. Protective Earth 1, 2: Note: Rated current 12A / pin 2: N 3, 4,5: + Note: Rated current 12A / pin 3: L 6: Temperature compensation NTC sensor 7: Alarm relay, normally closed (relay not energized) 8: Alarm relay, normally open (relay not energized) 9: Alarm relay, common 10: Temperature compensation NTC sensor 11: Not in use (Y selection code 1 or 3) OR Remote control input, shut down (Y=0 or 2) or battery test (Y=4 or 5) models Use 60/70 or 75 C copper (CU) wire only. The recommended terminal tightening torque is 0.5Nm.

DIMENSIONS 60W 125W 250W W 51 mm 66 mm 75 mm H 121 mm 148 mm 173 mm D 81 mm 113 mm 122 mm FREE INSTALLATION CHOICE Due to movable DIN rail connectors 5000- series modules can be flexibly installed to the available space CURRENT LIMITING CURVES 60W models 125W and 250W models Please note that curves present the current limiting principle only. Exact values and shape of curves varies between different models, refer specification. POWER DERATING CURVES ADC53xy 250W/12VDC Other ADC5000 models TEMPERATURE COMPENSATION EFFECT TO FLOAT CHARGE VOLTAGE Temperature Compensation Curve ADC5000 series 12VDC models Temperature Compensation Curve ADC5000 series 48VDC models voltage [VDC] 15,0 14,5 14,0 13,5 13,0 12,5 12,0-40 -30-20 -10 0 10 20 25 30 40 50 Ambient temperature [ C] voltage [VDC] 62 60 58 56 54 52 50 48-40 -30-20 -10 0 10 20 25 30 40 50 Ambient temperature [ C] Temperature Compensation Curve ADC5000 series 24VDC models voltage [VDC] 30 29 28 27 26 25 24-40 -30-20 -10 0 10 20 25 30 40 50 Temperature compensation sensor 2.2k ohm NTC resistor is included in rectifier models (x =7, 8 or 9) delivery Ambient temperature [ C]

INTENDED USE The power supply shall only be installed and put into operation by qualified personnel. This power supply is designed for building purposes in an enclosure and is intended to be used in industrial and telecom applications. Units can be used as a power supply or for float charging batteries in standby battery back-up solutions. For safety reasons external fuse or circuit breaker must be installed between the rectifier and battery. R-version units also fulfill demanding environmental requirements like shocks, vibration, humidity and wide ambient temperature range. 250W units without P in the end of type number do not comply with EN61000-3-2 harmonics standard. These units are intended to be used in non-public networks only. SAFETY PRECAUTIONS Do not use the unit without proper earth connection (Protective Earth). Turn power off from AC input wires before working with the power supply. Units are intended to be used as permanently connected equipment (excluding bench models with fixed power cord). Readily accessible disconnection device shall be incorporated in building installation wiring. If unit is used for charging batteries, external fuse or circuit breaker must be installed between the rectifier and battery. WARNING! Dangerous voltages, capable of causing death, are present in this equipment. Do not remove the cover. No operator serviceable parts inside. Refer servicing to qualified service personnel. 115/230V INPUT VOLTAGE SELECTION 125/250W models: The unit is factory set to operate with a 230V nominal input voltage. The nominal input voltage can be selected via the internal 115/230 voltage selector on the PCB. Access to the selector is through the ventilation holes of the unit cover. Always disconnect power before selecting. 60W models: The unit is wide input type and will work without modification from 90VAC to 264VAC. USING UNIT WITH DC INPUT 60W units can be operated also by DC input voltage. See voltage range from specification and connection from pin configuration. Note! DC input is not UL60950-1 approved. OUTPUT VOLTAGE ADJUSTMENT AND BATTERY CHARGING APPLICATIONS The output voltage of the module can be adjusted with the multi-turn potentiometer located on the front panel. All models can be used either as a power supply or a standby battery charger by correct adjustment. Please note that the output of the unit is not reverse voltage protected and wrong battery polarity will break the unit. So pay attention to the correct polarity. Note! For safety reasons external fuse or circuit breaker must be installed between the rectifier and battery. 125W and 250W models: Maximum output current is available within the full voltage adjustment range. 60W models: Maximum output power is available within the full voltage adjustment range ALARM RELAY The potential free alarm output indicates if the output of the unit is healthy. Alarm relay contacts, both normally open and normally closed, are presented on the unit connector. If the output is healthy, the NO and COM pins are short circuited. If the unit fails the relay contacts will changeover and NC and COM pins will be short circuited. Word normal in relay pins means that mode when relay is not energized. SERIES / PARALLEL CONNECTION Reserve 2cm space on both sides for proper cooling. Parallel operation: Passive load sharing. Do not chain the outputs, rated current 12A / pin. Recommended cable size: 2.5mm 2, length > 0.5m for optimum load sharing. External series diodes are needed for parallel connection of 60W models (FET type built in series diode circuit does not work properly in parallel connection). 125/250W models can be connected in parallel with or without series diodes. Redundant n+1 system can be made only with series diodes. Series operation: Up to 500V total voltage. TEMPERATURE COMPENSATION Temperature compensated charging provides the optimum float charge voltage when batteries are being used. To utilize this feature it is necessary to install a NTC sensor across the temperature compensation pins on the output connector. It is also necessary to set the jumper on the front panel to ON position. The output voltage should be adjusted when the jumper is in the OFF position. This will simulate room temperature and ensure accuracy. The recommended sensor type is a 2.2k ohm NTC resistor, e.g. Epcos B57164-K222-K. The sensor should be installed local to the batteries. The sensor is galvanically connected to the + output. Temperature compensation sensor is included in rectifier models (x =7, 8 or 9) delivery LED A green LED indicates that the output of the module is healthy. OUTPUT OVERCURRENT PROTECTION Automatic, self-resetting electronic current limiting is included and the output is short circuit proof. OUTPUT OVER VOLTAGE PROTECTION (OPTION) of the unit will shut down if the output voltage rises above protection level. (16Volts/12V models, 31Volts/24V models and 58 Volts/48V models). Protection must be manually resetted by disconnecting the AC mains voltage. OUTPUT VOLTAGE REMOTE SHUT DOWN AND BATTERY TEST OPTIONAL MODELS of the unit will shut down, when a +4 15VDC signal is applied to the remote control input (RC) with reference to negative output. In battery test models output voltage drops 15-25% when a +4 15VDC signal is applied to the RC pins as above. The output voltage will return to the original level, when +4 15VDC signal is removed from RC pins. INTERNAL OUTPUT SERIES DIODE OPTION (125/250W series diode, 60W FET circuit) The internal diode is placed in series with the positive output. The benefits of having the diode fitted are: - Improved redundancy if the modules are connected in parallel (not for 60W models, external series diode needed) - Power OK signal and LED work independently regardless battery or parallel connections - The parallel connected modules can be Hot Plug replaced without the system output power interruption (60W models need external series diode) - The reverse current bleed is low if a battery is connected to the output of the rectifier The disadvantages of having the diode fitted are lower efficiency, deration to the output voltage regulation and load sharing. Note: The output series diode does not protect against reverse polarity connection of the battery.