REVISIONS INDEX 2016 ROAD & BRIDGE STANDARDS. September 2017 Revision Letter August 2017 Revision Letter February 2017 Revision Letter

Similar documents
REVISIONS INDEX 2016 ROAD & BRIDGE STANDARDS

To: All Holders of the Virginia Department of Transportation s 2001 Road and Bridge Standards

Current Standard Plates including Transmittal Letters are available on the web at:

Ohio Department of Transportation Office of Roadway Engineering January 18, 2013

Standard Plate 7036 is discontinued. It is replaced by Standard Plan Pedestrian Curb Ramp Details.

Manhole or Catch Basin Type A & B Cone Sections Precast - Design F Manhole or Catch Basin Cover (Reducer Cone Section Precast) Design D

INSTRUCTIONS: 1. Record the transmittal letter number, date, and subject on the transmittal record sheet located in the front of the manual.

Ohio Department of Transportation Office of Traffic Engineering July 17, 2009

2. Remove from the Standard Plate manual: Standard Plate Index, Sheets 1-4 of 4, Numerical Index of Standard Plates (August 31, 2012)

SUBJECT: Standard Plate 9102 Turf Establishment Areas At Pipe Culvert Ends

Current Standard Plates including Transmittal Letters are available on the web at:

SUBJECT: Standard Plate Turf Establishment Areas (at Pipe Culvert Ends)

SUBJECT: Standard Plates 4132, 4155, Drainage Structures and Castings Info

E:\Wilmot\DGN\14018pp.dgn 3/11/2015 6:49:16 AM

Midwest Roadside Safety Facility

Midwest Roadside Safety Facility

Guide Sign Policy for Secondary State Highways Edition

Plate 8132A - Preformed Rigid PVC Conduit Loop Detector, is a new plate requested by OTST.

B " 787

3616 Old Howard Co. Airport Road Big Spring, TX

Standard 25 Wide Structure

Vertical Offset Base and Safety Rail System Installation Instructions

MH Table of Contents Standard Title/Scope Page Table of Contents SCE Public

Manholes Table of Contents

SIGNALS AND LIGHTING FIELD GUIDE

Chapter 25. Lighting Plans

Midwest Roadside Safety Facility

3616 Old Howard Co. Airport Road Big Spring, TX

TYPE J (20 FT - 40 FT) MICHIGAN DEPARTMENT OF TRANSPORTATION 10-0" 7-6" NOTE: sheet 5 & 6 of 10) DEPARTMENT DIRECTOR. Kirk T.

Midwest Roadside Safety Facility

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

Standard Plate Sheer Reinforcement for Precast Drainage Structures has been updated upon recommendation of the Bridge Office.

SKT-SP Tangent Terminal

HOENER ASSOCIATES INC. ARCHITECTS

DOCUMENT SUBMITTAL REQUIREMENTS FOR A NEW MULTI-FAMILY DWELLING

Open shipping crate and separate all of the different parts. Over The Top Shelters LLC

Standard Signs Manual

SIGN MOUNTED BEACON SIG-027-A SINGLE SIGN MOUNTED FLASHING BEACON INSTALLED ON ONE WOOD POST DETAIL "A-1"

Work Type Definition and Submittal Requirements 14.6 Signing Plan Design & Special Provisions. Work Type Definition

Midwest Roadside Safety Facility

2x6. 2x8. 2x10. Size. 2-2x10 8'-5" w/ 2 NJ 7'-3" w/ 2 NJ

SIG-032-B TRAFFIC SIGNAL MAST ARM POLE AND MAST ARM DETAILS - CATEGORY III LUMINAIRE ARM (SEE CONTRACT) 6'-0", 8'-0", 10'-0" NOMINAL SPREAD

CASS TL-3 (Utilizing C-Shaped Post) Assembly Manual

Maintenance of Traffic sequence of operations including any phasing and detour maps;

DESIGN GUIDELINES (SD) COUNTY OF ALAMEDA PUBLIC WORKS AGENCY 399 ELMHURST STREET HAYWARD, CA

This specification describes the minimum technical requirements for drawings, as applicable to all disciplines.

REVISION INFORMATION SHEET ONTARIO PROVINCIAL STANDARDS FOR ROADS AND PUBLIC WORKS

SIG-030-B TRAFFIC SIGNAL MAST ARM POLE AND MAST ARM DETAILS - CATEGORY I LUMINAIRE ARM 6'-0", 8'-0", 10'-0" NOMINAL SPREAD (SEE CONTRACT) POLE CAP

Roof-Top Applications

STANDARD DRAWINGS INDEX MODIFIED FOR CENTRAL REGION Revised August 6, 2018

6/19/2014. Milton Madison Bridge Slide. Project Partners. The Challenge. Aaron L. Stover, PE, SE Michael Baker Jr., Inc.

HEADED ANCHOR BOLT OPTION

SECTION III STANDARD DRAWINGS ROYSE CITY GENERAL CONSTRUCTION NOTES & DETAILS

MAT106: Wall Framing. AMERICAN FOREST & PAPER ASSOCIATION American Wood Council Engineered and Traditional Wood Products

Bol FEATURES: SPECIFICATIONS: 8' 24' Round Tapered and Straight Wood Poles STRUCTURA INC. FIXTURE TYPE: PROJECT NAME:

INSTALLATION INSTRUCTIONS

APPENDIX 3-CLASSROOMS (review by MB) General Guidelines- All Classrooms

Installation Instructions

A Generic Sauna Room Assembly Manual

MDOTProjectwise\Documents\Reference Documents\Traffic Reference\Statewide Special Details\Develop

General Guidelines:

Assembly Instructions for. for 31" MGS (Midwest Guardrail System) ROAD SYSTEMS, INC.

DOCUMENT SUBMITTAL REQUIREMENTS FOR A NEW SINGLE-FAMILY DWELLING

This specification describes the minimum requirements for structural steel drawings.

OREGON DEPARTMENT OF TRANSPORTATION

GENERAL ISOMETRIC LAYOUT

Lighting Design. Debra A. Kennaugh, P.E. Lighting Design by Debra A. Kennaugh, P.E. A SunCam online continuing education course

DELINEATOR REFERENCE POINT 200' TYPICAL SPACING (YELLOW DELINEATORS) END OF MERGE LANE TAPER DELINEATOR REFERENCE POINT

VPN: ISBXLR. Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

Model: SS660-PT-R Stainless Steel Poly-Top Floor Scale Series. Installation, Set-Up and Operation Manual

BVS Cable support systems

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

Track Rack. * Track Racks are not lockable

CONTENTS TOOL LIST U P S I D E I N N O V A T I O N S, L L C RAMP AND STEP SYSTEM ASSEMBLY INSTRUCTIONS. Revised: June 2013

10x12 FOUNDATION GUIDE 10x12 TRICO AND FLORA SHEDS

CITY OF WHITE PLAINS STANDARD DESIGN CRITERIA AND SPECIFICATIONS FOR SMALL WIRELESS FACILITIES

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

CITY OF STOCKTON 2016 STANDARD PLANS AND SPECIFICATIONS PROPOSED REVISIONS

CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division STREET/ALLEY IMPROVEMENT PLAN REVIEW CHECKLIST

METER - INSTALLATION Pad Mount Transformer

Installation Instructions

STEEL PIPE GUIDERAIL 01/01/

Applied ATTENTION! LA12-25 LINE ARRAY TOWER INSTRUCTIONS lb WEIGHT LIMIT

ASSEMBLY INSTRUCTIONS FOR 14 x 14 SONOMA ARCHED TOP PERGOLA : OPTIONAL SIDEWALL WINDOW LATCHES Wall Panel Batten Strip Top Cap For Wall Base Beam For

DOCUMENT SUBMITTAL REQUIREMENTS FOR AN ALTERATION OR ADDITION TO AN EXISTING SINGLE-FAMILY DWELLING OR MULTI-FAMILY DWELLING

CEILING-MOUNTED MONORAIL ANCHOR TRACK SYSTEM Assembly and Operation Instruction Manual

RAIL PANEL AT TRANSITION SECTION PLAN - POST DETAIL PLAN - TUBE SPLICE. Colorado Department of Transportation. Staff Bridge Branch

Solutions AGRICULTURAL LABORATORY & CLASSROOM FURNITURE. Education to Industry. Solutions for Your Workspace & Storage Needs

IMPULSE G2/PULSE STATIC BRIDGE & RETURN MODULE. Drill. Desk Connecting. Outside by fastening the supplied wood screws from the HK-67 kit through the

1. Show the following information with additional information necessary to indicate shop compliance with the requirements of this section.

ASSEMBLY INSTRUCTIONS TF Tent Flooring System. 125 Taylor Parkway Archbold, Ohio Phone: (419) Fax: (419)

Multi-Stage ASSEMBLY INSTRUCTIONS ST-8100 SERIES. 125 TAYLOR PARKWAY ARCHBOLD, OH PHONE: (419) FAX: (419)

(50 FT FT) MICHIGAN DEPARTMENT OF TRANSPORTATION 10-0" 7-6" 8-0" 6-0" Truss Depth. 3" sheets 5 & 6 of 10) DEPARTMENT DIRECTOR. Kirk T.

The Mind Project s Iris 1 Robotic Arm. Packing List Assembly instructions

.1 Applicability: These criteria shall be applied as follows:

Thank you for purchasing out product! *Please read these instructions and follow them step by step. *

ProStack A1 A2. Modular LED Ground Stack System. Call: Visit:

Installation Instructions for the AlphaDeck Staging System

AUXILIARY FRAMING AND ACCESSORIES

Plastibeton Trench System. Installation Packet

Transcription:

REVISIONS INDEX 2016 ROAD & BRIDGE STANDARDS September 2017 Revision Letter August 2017 Revision Letter February 2017 Revision Letter

506.08 ADDED DETAIL FOR TRANSITION FROM GR-MGS1 TO WEAK POST GUARDRAIL. If you have any questions or comments regarding the 2016 Road & Bridge Standards, please contact Charles Patterson, P.E., at (804) 786-1805, of the Standards and Special Design Section. Sincerely, Signature on file Date: 9/26/17 Susan H. Keen, P.E. State Location & Design Engineer Page 2 of 2

Section 1300: Revised index pages 1300.01, 1300.02, 1300.03, & 1300.04 1302.20 MP-2 CHANGE LUMINAIRE CALLOUT FROM TRUSS TYPE LUMINAIRE ARM TO LUMINAIRE ARM 1302.24 MP-3 CHANGE LUMINAIRE CALLOUT FROM TRUSS TYPE LUMINAIRE ARM TO LUMINAIRE ARM. CHANGED DIMENSION FROM TOP OF POLE TO CENTER OF ARM FROM 12 TO 12 MIN. 1302.27 MP-3 CHANGE CASE X LOADING CALLOUT TO LOADING CASE X 1302.50 AB-1 REVISED NOTE 4 1302.60 VS-1 REVISED NOTE 6 1307.11 PA-4 REMOVED PA-3 DETAIL FROM THE STANDARDS 1310.20 LF-1 REVISED NOTE 8 1311.10 LP-1, 2 CHANGED BRACKET ARM LENGTH TO LUMINAIRE ARM LENGTH. SHOW BOTH LP-1 AND LP-2 STRUCTURES ON TRANSFORMER BASES; CLARIFY IN NOTES THAT STRUCTURES SHALL BE ON EITHER BREAKAWAY OR NON-BREAKAWAY TRANSFORMER BASES; REVISIONS TO NOTES REGARDING TRANSFORMER BASE INSTALLATION. DELETED NOTE REGARDING WIRE SUPPORT J-HOOKS FOR HAND HOLES MORE THAN 4 FEET UP THE STRUCTURE. 1317.10 JB-R1, R2 CLARIFICATION REGARDING NUMBER OF PLACEMENT OF REQUIRED J-HOOKS; MINOR DRAFTING IMPROVEMENTS; REVISED REQUIREMENTS FOR PLACEMENT OF AGGREGATE UNDERNEATH THE JUNCTION BOX AND COMPACTED EARTH ON SIDES OF JUNCTION BOX; CONDUIT ENTRANCE DEPTH REVISED TO READ 18-24 INSTEAD OF 18 ; DELETION OF NOTES THAT ARE DUPLICATES OF REQUIREMENTS IN THE SPECIFICATIONS. 1317.11 JB-R1, R2 MINOR REVISIONS TO NOTES 1317.20 JB-S1, S2, S3, S4 ADDITION OF 48 X 48 JB-S4 STANDARD; DELETION OF REQUIREMENT THAT JB S BE ONE- OR TWO- PIECE IN DESIGN; CLARIFICATION OF AGGREGATE AND COMPACTED SOIL PLACEMENT UNDERNEATH AND AROUND BOX; REVISION TO NOTE REGARDING ACCEPTABLE METHODS OF LABELING BOXES; CLARIFICATION REGARDING NUMBER OF PLACEMENT OF REQUIRED J-HOOKS; CONDUIT ENTRANCE DEPTH REVISED TO READ 18-24 INSTEAD OF 18 ; CORRECTED ERROR IN PREVIOUS STANDARD REGARDING LABELING OF DIMENSIONS A AND B 1317.21 JB-S4 NEW SHEET WITH DETAILS FOR 48 X 48 JB-S4 JUNCTION BOX 1320.10 WSP-1 STANDARDS EXPANDED TO 7 SHEETS 1320.11 WSP-1 STANDARDS EXPANDED TO 7 SHEETS 1320.12 WSP-1 STANDARDS EXPANDED TO 7 SHEETS 1320.13 WSP-1 SOME DETAILS MOVED TO SHEET 5 Page 2 of 3

Section 1300: 1320.14 WSP-1 SQUARE TUBE POST DESIGN TABLE MOVED TO SHEET 6. SHEET 5 NOW ENCOMPASSES DETAILS FOR SIGN PANEL ATTACHMENTS TO POSTS, INCLUDING NEW ALTERNATE ATTACHMENT DETAILS AND NEW DETAILS FOR MOUNTING OF BACK-TO-BACK SIGNS. 1320.15 WSP-1 SQUARE TUBE POST DESIGN TABLE MOVED FROM SHEET 5. 1320.16 WSP-1 NEW SHEET WITH SPLICE AND CORNER BOLT DETAILS PREVIOUSLY INCLUDED ON SHEET 6. ORIENTATION OF CORNER BOLTS CHANGED SO THAT ALL CORNER BOLT HEADS ARE ON LEFT SIDE. 1321.10 STP-1 SINGLE POST MEDIAN INSTALLATION DETAIL MOVED FROM SHEET 12; ADDED NOTES 9 AND 10. 1321.17 STP-1 CORRECTED CALLOUT FOR DRIVE TUBE FOUNDATION MATERIALS TO REQUIRE 3/16, NOT 1, STEEL PLATE. 1321.19 STP-1 SOME DETAILS MOVED TO SHEET 12 OF 12 1321.20 STP-1 INCREASED ALLOWABLE MAXIMUM WIDTH OF SIGN ON A SINGLE POST FROM 5 FEET TO 6 FEET 1321.21 STP-1 DETAILS REGARDING SIGN MOUNTING HEIGHT/PLACEMENT FOR INTERCHANGE OFF-RAMPS MOVED TO NEW STANDARD ISD-1. SIGN BRACING DETAILS MOVED FROM SHEET 10 TO SHEET 12. NEW DETAILS WITH ALTERNATE SIGN PANEL MOUNTING DETAILS, AND NEW DETAILS SHOWING HOW TO ATTACH BACK-TO-BACK SIGN PANELS ON THE SAME POST. 1329.10 ISD-1 NEW STANDARD SHOWING SPECIAL SIGN PLACEMENT AND MOUNTING HEIGHT REQUIREMENTS FOR CERTAIN SIGNS ON INTERCHANGE OFF-RAMPS. Any questions related to Section 1300 should be directed to the Traffic Engineering Division. If you have any questions or comments regarding the 2016 Road & Bridge Standards, please contact Charles Patterson, P.E., at (804) 786-1805, of the Standards and Special Design Section. Sincerely, Signature on file Date: 8/31/17 Susan H. Keen, P.E. State Location & Design Engineer Page 3 of 3

The following Special Design sheets were added to the Central Office Environment on Falcon DMS and the FTP Server. RSS Reinforced Soil Slope (Sheets 1-2) If you have any questions or comments regarding the 2016 Road & Bridge Standards, please contact Charles Patterson, P.E., at (804) 786-1805, of the Standards and Special Design Section. Sincerely, Signature on File Date: 2/16/17 B. A. Thrasher, P.E. State Location & Design Engineer Page 2 of 2