Xcel 255 & 455 Slit Lamps

Similar documents
Beautifully Crafted Slit Lamps.

Keeler Catalogue. All Keeler products are designed to offer the ultimate in professional performance.

KTP LASER. Photocoagulation System

Ophthalmic Slit-lamp Microscope (SLM 1ER) Operation. Instruction

Manual for BMS E1 eplan series, compound microscope

Beautifully Crafted Slit Lamps

Headline. SL 130 Slit Lamp. Subline. Maximum quality for optimum performance

User manual.

Zoom Stereo Microscope NYMCS-360 Instruction Manual

Beautifully Crafted Slit Lamps

CONNECTING VISIONS. TRC-50DX Digital Ready Retinal Camera

11/10/2015. Haag Streit Topcon Zeiss Kowa Add On Systems- OIS/Escalon and Others. The Original Design. Photo Slit lamp Systems. Who Makes Them?

User Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com

SLIT LAMP BQ 900 Sophisticated microscopy

SLIT LAMPS Confidence that lasts

OMM300. Inverted Metallurgical Microscope

Stereo Viewing Systems

Basic Principles of the Surgical Microscope. by Charles L. Crain

User Manual. Trinocular Metallurgical Microscope. MicroscopeNet.com

Price catalogue. ZRS HD-M 10x42 Waterproof Monocular with dielectric prism coating ZRS HD (SUMMIT) 8x42 Waterproof Binoculars

ML7520 ML7530 DIOPTER ADJUSTMENT RING BINOCULAR BODY, INCLINED 30. (a) Field Iris Control Lever. (c) Filter Slots EYEPIECES, KHW10X

Optoliner NV. Calibration Standard for Sighting & Imaging Devices West San Bernardino Road West Covina, California 91790

Eyepieces KHW10X. Diopter Adjustment Ring. Binocular Body Inclined 30. Binocular Clamp Screw. Analyzer control Lever. Reflected Light Illuminator

Biological Microscope. Biological Microscope ECLIPSE E100

HEINE QUALITY. :- HEINE Hand-held Ophthalmic Instruments

Instruction Manual T Binocular Acromat Research Scope T Trinocular Acromat Research Scope

SLIT LAMP BI 900 Simplified operation high reliability

Instruments for refraction and diagnosis. Catalogue

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

MAGNIFIERS & TASK LAMPS FOR INDUSTRY. presented by

Marco TRS Total Refraction System

Reading: Lenses and Mirrors; Applications Key concepts: Focal points and lengths; real images; virtual images; magnification; angular magnification.

Characterization Microscope Nikon LV150

VISULAS Trion. Treatment flexibility to the power of three. Multicolor Photocoagulation Laser

25 cm. 60 cm. 50 cm. 40 cm.

Compound Microscopes Instruction Manual

Indian Institute of technology Madras Presents NPTEL NATIONAL PROGRAMME ON TECHNOLOGY ENHANCED LEARNING

Motorized Axio Observer Start-up instructions

Preface. General Requirements for Safety. Precautions

Therefore, all descriptions and illustrations in this instruction manual, including all specifications are subject to change without notice.

Stereo Viewing Systems

Lecture 2 Slit lamp Biomicroscope

TABLE OF CONTENTS. Safety notes i. Care and Maintenance. ii. 1. Components Illustration Installation of Components.. 4

UCM: The Universal Comparison Macroscope for Forensic Investigations

Optical Inspection Systems

BA310POL ADVANCED POLARIZATION MICROSCOPE

User Manual. Trinocular Infinity Compound LED Microscope. MicroscopeNet.com

MAKING SENSE OF SLIT LAMP SERVICING

Keeler Direct Ophthalmoscopes

Family of Stereo Microscopes Quality microscopes for industry and life sciences

Easy Kohler Illumination Method

A DIVISION OF FORENSIC TECHNOLOGY. UCM pia The Universal Comparison Macroscope for Forensic Investigations

Tabletop Refraction System TS-310

Versatile Functionality RT-5100 SMART REFRACTOR

Stereo Viewing Systems

1) An electromagnetic wave is a result of electric and magnetic fields acting together. T 1)

General Physics Experiment 5 Optical Instruments: Simple Magnifier, Microscope, and Newtonian Telescope

A DIVISION OF FORENSIC TECHNOLOGY. UCM pia The Universal Comparison Macroscope for Forensic Investigations

Collection Scanning Solutions. The ST ViewScan II System FILM FICHE FASTER TM

Stereo Viewing Systems

XSP-100XSP-100SM/ OF BIOLOGICAL MICROSCOPE OPERATION MANUAL READ THIS MANUAL BEFORE USING THE MICROSCOPE

TEKSCOPE MICROSCOPE. Models N2 Series USER S MANUAL

Operating Light marled V10 / V10 Ceiling

BETA Otoscopes & Ophthalmoscopes DIAGNOSTIC INSTRUMENTS

PAINT BORER 518 MC PAINTXPLORER 548

HEINE Direct Ophthalmoscopes

AMCON LENSOMETER USER S MANUAL EQ Fax

Introduction. Geometrical Optics. Milton Katz State University of New York. VfeWorld Scientific New Jersey London Sine Singapore Hong Kong

12 x 12 anti-glare screen provides a clear, detailed view of your microform.

Digital Slit Lamp Photography. A User s Primer

Systems Biology. Optical Train, Köhler Illumination

PHYS 160 Astronomy. When analyzing light s behavior in a mirror or lens, it is helpful to use a technique called ray tracing.

MANUAL MICROSCOPE SERIES. 73 Mall Drive, Commack, NY (P) (F)

Lambda 1050 / 950 UV/Vis/NIR

HEINE BETA 200S Ophthalmoscope

SLIT LAMP INSTRUCTIONS FOR USE Z Series

EXC500p-- PATHOLOGY MICROSCOPE. EXC500hd -- HD DIGITAL PATHOLOGY MICROSCOPE. EXC500r -- RESEARCH MICROSCOPE EXC500-LABORATORY SCOPE

EE119 Introduction to Optical Engineering Fall 2009 Final Exam. Name:

Operating Light marled V16 / V10 D

THE ONLY PORTABLE, AFFORDABLE INSTRUMENT OFFERING THREE-DIMENSIONAL VIEWING AND ILLUMINATION INTO A SMALL CAVITY.

Metrology Prof. Dr Kanakuppi Sadashivappa Bapuji Institute of Engineering and Technology Davangere. Lecture 24 Measurement of Screw Thread Element

OM FL400. Reflected Light Fluorescence Microscope. Instruction Manual. Please read instructions carefully before using microscope.

Table 8 Overview light sources

FLUOLED 21 the plug-and- play microscope for TB (Mycobacterium tuberculosis), based on Olympus CX 21 microscope

STEINDORFF Digital LCD Biological Microscope

MANUAL BMS SPEC5000 Spectrophotometer

Faster, Easier and More Accurate AUTO LENSMETER LM-1200/1000(P)

Phys 531 Lecture 9 30 September 2004 Ray Optics II. + 1 s i. = 1 f

There is a range of distances over which objects will be in focus; this is called the depth of field of the lens. Objects closer or farther are

Physics 1411 Telescopes Lab

Slit Lamp Instructions for use H Series

Properties of optical instruments

Stereomicroscopy. KL1500 LCD and KL 2500 LCD Cold Light Sources. Light Sources for Illumination and Contrasting. Microscopy from Carl Zeiss

Readings: Hecht, Chapter 24

Physics 102 Exam 3 Fall Last Name: First Name Network-ID

Physics 222, October 25

LM-1200 / 1000(P) AUTO LENSMETER

User instructions Metallurgical inverted microscope

CLEMENT CLARKE OPHTHALMIC

Section A Conceptual and application type questions. 1 Which is more observable diffraction of light or sound? Justify. (1)

Transcription:

Xcel 255 & 455 Slit Lamps Where performance and value converge. Advancing Eye Care. American Innovation. www.reichert.com

Xcel 255 Slit Lamp Compact design High efficiency multilayer optical coatings for enhanced light transmission Wide-field optics Halogen illumination 3 step magnification 10x, 16x, 25x Feather-touch XYZ joystick 12.5x magnification eyepieces Red free, cobalt blue, heat absorbing, neutral density filters

Xcel 455 Slit Lamp Traditional tower illumination design High efficiency multilayer optical coatings for enhanced light transmission Wide-field optics 5 step magnification 6.5x, 10x, 16x, 25x, 40x 12.5x magnification eyepieces Slit inclination up to 20 degrees Red free, heat absorbing, cobalt blue, neutral density filters Halogen illumination Smooth base movement and slit elevation with XYZ joystick

Xcel 255 Slit Lamp Specifications Catalog Numbers 15120 Xcel 255 Slit Lamp 15122 1-Port Beam Splitter 12588 6V 20W Halogen Lamp 12597 CT210 Tonometer Mount 12598 CT210 Tonometer 12596 Tonometer Prism Microscope Microscope Type Galilean Magnification Change 3 step rotation Eyepiece 12.5x Magnification Ratio 10x, 16x, 25x Fields of View 25, 15, 10 mm PD Range 48.5-80 mm Diopter Adjustment ±5 Working Distance 107.7 mm Slit Lamp Slit Illumination 6V 20W halogen Slit Width 0-13.5mm Slit Length 0-13.5 mm Slit Apertures 0.6, 5.8, 9, 13.5 mm Slit Rotation 0 180 Slit Inclination -5, -10, -15, -20 Filters Red free, cobalt blue, heat absorbing Illuminance Range 0 to >50000 lux Base Movement Ranges Longitudinal (In/Out) Lateral (Left/Right) Vertical (Up/Down) Chinrest Fixation Lamp Vertical Movement Power Voltage Power Input (max) Frequency Fuses Dimensions/Weight Height Width Depth Table Dimensions Weight, Packed 90 mm 107 mm 30 mm White LED 80 mm 90-250 VAC 56-73 VA 50/60 Hz Time-lag (1.6A, 250V), 5x20 mm 50.2 cm (19.8 in) 26.7 cm (10.5 in) 35.6 cm (14.0 in) 465 x 316 mm 23.64 kg (52 lbs.)

Xcel 255 Slit Lamp Reichert Xcel Slit Lamps utilize high quality optics, providing clarity and detail that will meet the needs of even the most discriminating operator. The feather-touch XYZ joysticks, convenient controls, and ergonomic design, combined with top quality materials and meticulous assembly, ensure years of comfortable, enjoyable use. The outstanding optical performance, features and quality make the Reichert Xcel series comparable to the world s elite slit lamps. The available CT210 Contact Tonometer can be easily mounted on the Xcel 255.

Xcel 455 Slit Lamp The Xcel 455 s precision optics incorporate lenses with high efficiency multilayer optical coating for enhanced light transmission, resulting in bright, even illumination and outstanding image clarity. A large field of view with high resolution and depth of focus offers an excellent stereo binocular view. The five step magnification changer and filter options provide flexibility in viewing different structures of the eye. Eyepieces with 12.5x magnification and converging binoculars ensure comfortable viewing. Slit inclination up to 20 allows examination in the oblique sections. The base and slit elevation can be maneuvered smoothly and easily using the joystick control. The available CT100 Contact Tonometer can be easily mounted on the Xcel 455.

Xcel 455 Slit Lamp Specifications Catalog Numbers 15140 Xcel 455 Slit Lamp 15121 Halogen Lamp 12591 CT100 Tonometer 12595 Tonometer Prism Microscope Microscope Type Galilean Magnification Change 5 step drum rotation Eyepiece 12.5x Magnification Ratio 6.5x, 10x, 16x, 25x, 40x Fields of View 37, 24, 15, 9, 6 mm PD Range 49 78 mm Diopter Adjustment ±6 D Working Distance 107.7 mm Slit Lamp Slit Illumination 6V 20W halogen Slit Width 0 12 mm Slit Length 1.5 12.5 mm Slit Apertures 0.3, 1, 3, 5, 9, 12 mm Slit Rotation 0 180 Slit Inclination -5, -10, -15, -20 Filters Red free, heat absorbing, cobalt blue, neutral density Illuminance Range 0 to >50000 lux Base Movement Ranges Longitudinal (In/Out) Lateral (Left/Right) Vertical (Up/Down) Chinrest Fixation Lamp Vertical Movement Power Voltage Power Input (max) Frequency Fuses Dimensions/Weight Height Width Depth Table Dimensions Weight, Unpacked 110 mm (4.3 in.) 110 mm (4.3 in.) 30 mm (1.2 in.) White LED 70 mm (2.8 in.) 100 240 VAC 56 73 VA 50/60 Hz Time-lag (1.6A, 250V), 5x20 mm 66.0 cm (26.0 in.) 45.7 cm (18.0 in.) 34.3 cm (13.5 in.) 46.5 x 32 cm (18.3 x 12.6 in.) 17.8 kg (39.3 lbs.)

Xcel Slit Lamps Where performance and value converge. www.reichert.com Call Reichert at +1 716-686-4500, toll-free 1-888-849-8955, or contact your Authorized Reichert Technologies Distributor. 3362 Walden Avenue, Depew, NY 14043 USA 2015 AMETEK, Inc. & Reichert, Inc. 15120-110-Rev-B