Panel Mount "Hockey Puck" Relays and DIN Rail Mounted Solid State Relays up to 120 Amps

Similar documents
NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays

GTT 25A - 40A - 60A - 90A - 120A POWER SOLID STATE RELAYS WITH ANALOG CONTROL

77 Series - Modular Solid State Relay 5 A. Features. Timers and Monitoring relays

3.6. Control Relays and Timers D A M D 2. Contents. Product Overview. Catalog Number Selection. Solid-State Relays

Industrial, 2-Pole ZS Type RA2A

38 Series - Relay interface modules A

38 Series - Relay interface modules A

Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink

Control Input. Status Ouputs. 0 to 24VDC 1A AC/DC. Fig. 1 TYPICAL APPLICATIONS Fig. 2 WIRING DIAGRAM

celduc SIM Phase angle controller Output : VAC 40A(*) Input : Analog 0-10V r e l a i s celpac

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

celduc SILD r e l a i s celpac PATENTED! AC Semiconductor Contactor pitch 22,5mm with Diagnostic compact size and DIN rail mounting.

celduc SILD Output : VAC 32A(*) Input : 3-32VDC - I<10mA Diagnostic : 30VDC - 100mA r e l a i s celpac P roud to serve you

Semiconductor contactors, Solid-state relays

Type CP-S, CP-C & CP-A Switch mode

Features. Regulated Converters. RAC01-C RAC02-C 1-2 Watt Single Output RAC0_- C. AC/DC Converter

Status Ouputs. Control Input. 0 to 24VDC 1A AC/DC. 4-20mADC. Fig. 1 TYPICAL APPLICATIONS Fig. 2 WIRING DIAGRAM

Subject to changes 11/2003 Page 1/7

Solid State Relays 1-Phase, Zero Cross or Instant On Switching 25 AAC, 230 VAC with LED and Built-in Transil Types RF1A, RF1B

Rated power VA (50 Hz)/W 0.6/ / / /0.3 Operating range V AC (50/60 Hz)

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

celduc SIL Phase angle controller Output : VAC 32A(*) Input : Analog 0-10V celpac r e l a i s Proud to serve you

SOLID STATE RELAY RATINGS

RP1A, RP1B. 1-phase PCB mount solid state relays. Main features. Description

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

QUINT-PS/ 3AC/24DC/10

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

QUINT-PS-24DC/24DC/10

QUINT-PS AC/24DC/40

83 Series - Modular timers 16 A. Features

Solid State Relay. Zero Switching Types RGC Solid State Contactor 'U' Connection. Product Description RGC 1 A 60 A 40 K G U _.

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

Multi-voltage Multi-function. Wiring diagram (without control signal)

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

Zelio Control Measurement Relays

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

RP1A, RP1B. 1-phase PCB mount solid state relays. Main features. Description

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

QUINT-PS/ 1AC/24DC/20

High precision measurement system for current and voltage IHC-A/B-RM01/03

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

38 Series - Relay interface modules A. Features /

RN Thyristor Controllers

Power Supplies 3. SDN-C Compact DIN Rail Series

Solid-state Contactor Specifications

38 Series - Relay Interface Modules A

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

Electronic timer CT-SDD.22

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

To be automatically connected to the nearest North American Technical Sales Office:

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

CCH400 & CCH600 Series

celduc SIM Phase angle controller Output : VAC 40A(*) Input : Analog 0-10V celpac r e l a i s Proud to serve you

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

TE200S Solid State Relays. Two-phase control of three-phase loads. User manual

Semiconductor contactors, Solid-state relays

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

CI-tronic Analogue Power Controller ACI 30-1 and ACI 50-1

Energy Management Energy Meter Type EM110

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Three-phase monitoring relays CM-PFE and CM-PFE.2

QUINT-PS/ 3AC/24DC/40

Characteristics 5 TeSys k contactors and reversing contactors

PRELIMINARY DATA MOSFET BASED DC SOLID-STATE RELAY. In & case / Out Insulation VDC 2.5kV Screw terminals 45 x 58.5 x 30 80g. Fig.

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

IGBT BASED DC SOLID-STATE RELAY. In & case / Out Insulation. Fig. 2. Please consult us to select the right protective components C1, D1 & D2.

MasterINTERFACE 39 Series - Relay interface modules

05/09/2012

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

Solid-state Timer H3DS

MOSFET BASED DC SOLID-STATE RELAY. In & case / Out Insulation. Fig. 2. Please consult us to select the right protective components C1, D1 & D2.

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

MasterINTERFACE 39 Series - Relay interface modules

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

MOSFET BASED DC SOLID-STATE RELAY. In & case / Out Insulation VDC 2.5kV Screw terminals 45 x 58.5 x 30 80g. Fig. 2

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

IGBT BASED DC SOLID-STATE RELAY. In & case / Out Insulation. Fig. 2. Please consult us to select the right protective components C1, D1 & D2.

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

Installation and Operational Instructions for ROBA -switch Type 017._00.2

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

Electronic timer CT-SDS.22

08/07/2015

Switching Power Supply Type SPP1 60W Enclosed type

MINI-PS AC/24DC/1.3

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Transcription:

Panel Mount "Hockey Puck" elays and DIN ail Mounted Solid State elays up to 120 Amps Common Applications Heating controls Injection molding machines Semiconductor manufacturing equipment lass processing Welding controls Food processing Industrial & commercial ovens Soldering machines Medical equipment Office machinery obotics With over forty years of experience, efran is the world leader in the design and production of solutions for measuring, controlling, and driving industrial production processes. efran s know-how and experience guarantee continuity and tangible solutions. efran s line of solid state relays are the ideal solution for applications where high speed switching and long life are essential. In specific applications, solid state relays offer many advantages over electromechanical devices including no moving parts or contact arcing. In addition, solid state relays are directly compatible with logic components such as microprocessors and PLCs. Broad selection for many applications The efran Q solid state relays are available in single phase hockey puck models up to 90 amps and the TS DIN-rail single phase units with integral heatsink up to 120 amps. The TZ three phase models with integral heatsink up to 55 amps are also available. Opto-isolated input limits current leakage All efran solid state relays feature opto-isolated inputs where an internal LED signals a photosensitive element when output switching is to occur. This provides up to 4,000V isolation between the input voltage and the output voltage and also limits current leakage. This feature is important in certain medical, residential and industrial applications. The efran solid state relays also include built-in metal oxide varistor (MOV) protection to protect against internal damage to the solid state relay. Output Circuit Features The efran solid state relays feature zero voltage turn-on, which means they are designed to turn on at the next zero crossover after application of the control voltage. This limits electromagnetic interference, reducing the chance of damage to downstream equipment. A built-in MOV reduces the likelihood of damage to the relay from rapid changes in voltage (dv/dt) and transient voltages. Many safety and convenience features All efran solid state relays come standard with an LED to indicate when the relay is in an operational state. This increases safety and speeds troubleshooting. In addition, all Q hockey puck type relays come standard with a load side cover that provides touch protection. The TS DIN-ail mounted relays also offer touch protection through the use of a removable protective cover plate. 80

Solid State elays Integral heatsink with DIN-rail mounting A complete selection of solid state relays are available with a built-in heatsink (TS/TZ models). This eliminates the hassle of selecting and installing a properly sized heatsink, or mounting to a panel mount relay directly on the back pan with silicone thermoconductive grease. ➌ ➎ ➋ ➍ ➋ ➍ ➊ ➏ ➐ ➊ Finger Safe Protection Covers ➋ AC or DC Input Connections ➌ AC Output Connection Models ➍ LED Status Indicator ➎ Internal MOV protection ➏ Integrated or optional heatsinks Approvals The Series Q and TZ solid state relays are cuus approved and CE marked. The TZ DIN-rail solid state relays are culus Listed and CE marked. ➎ ➌ ➑ ➏ ➐ cuus, CE ➑ culus, CE Catalog Number Quick uide Q- 1 5-2 4 - D - 1-4 Hockey Puck 1-Phase Panel Mount Nominal Current Nominal Voltage Control Voltage Overvoltage Connectors 15 15A AC 24 230V AC D 3 32V DC 1 Internal 4 Two-pin screw 25 25A AC 60 600V AC A 20 260V AC protection connector, low profile 50 50A AC enclosed 90 90A AC TS- 2 5 / 6 0 - D - 0 - VEN-91 1-Phase DIN ail mount ated Current ated Voltage Control Voltage Alarm Output Fan 60 600V AC D 6 32V DC A 20 260V AC/DC 15 15A AC 25 25A AC 40 40A AC 50 50A AC 60 60A AC 75 75A AC 90 90A AC 120 120A AC 0 None VEN-90 230V 14W 80x80x40 VEN-91 115V 14W 80x80x40 equired on 120A models only TZ 4 0 / 6 0 - D - 0 - VEN-91 3-Phase DIN ail mount Nominal Current Nominal Voltage Control Voltage Alarm Output Fan 25 25A AC 60 600V AC D 5 32V DC 0 None VEN-90 230V 14W 40 40A AC A 20 260V AC/DC 80x80x40 55 55A AC VEN-91 115V 14W 80x80x40 equired on 40A & 55A models only 81

Solid State elays Series Q Panel Mount elays 1 Pole Panel Mount elay, 3-32V DC Control, 230V AC Output Specifications 15 Amp 25 Amp 50 Amp 90 Amp Catalog Number Price Catalog Number Price Catalog Number Price Catalog Number Price Q-15-24-D-1-4 35.71 Q-25-24-D-1-4 39.68 Q-50-24-D-1-4 62.70 Q-90-24-D-1-4 82.54 Input Voltage ange 3-32V DC 3-32V DC 3-32V DC 3-32V DC Turn-on Voltage (min.) 2.7V DC 2.7V DC 2.7V DC 2.7V DC Turn-off Voltage (max.) 1V DC 1V DC 1V DC 1V DC Consumption 13mA @ 32V 13mA @ 32V 13mA @ 32V 13mA @ 32V everse Voltage < 36V DC < 36V DC < 36V DC < 36V DC Output Amp ating AC51 15 25 50 90 Nominal Voltage 24 230V AC 24 230V AC 24 230V AC 24 230V AC Maximum Voltage 20 253V AC 20 253V AC 20 253V AC 20 253V AC Zero Switching Voltage 20V 20V 20V 20V Frequency ange 45 65 Hz 45 65 Hz 45 65 Hz 45 65 Hz Dimension (mm) 58 (H) x 45 (W) x 30.5 (D), from base to top of control terminal 45 (D) 1 Pole Panel Mount elay, 20-260V AC Control, 230V AC Output Specifications 15 Amp 25 Amp 50 Amp 90 Amp Catalog Number Price Catalog Number Price Catalog Number Price Catalog Number Price Q-15-24-A-1-4 42.06 Q-25-24-A-1-4 43.65 Q-50-24-A-1-4 69.84 Q-90-24-A-1-4 88.89 Input Voltage ange 20 260V AC 20 260V AC 20 260V AC 20 260V AC Turn-on Voltage (min.) 15V AC 15V AC 15V AC 15V AC Turn-off Voltage (max.) 6V AC 6V AC 6V AC 6V AC Consumption 8mA @ 260V AC 8mA @ 260V AC 8mA @ 260V AC 8mA @ 260V AC Output Amp ating AC51 15 25 50 90 Nominal Voltage 24 230V AC 24 230V AC 24 230V AC 24 230V AC Maximum Voltage 20 253V AC 20 253V AC 20 253V AC 20 253V AC Zero Switching Voltage 20V 20V 20V 20V Frequency ange 45 65 Hz 45 65 Hz 45 65 Hz 45 65 Hz Dimension (mm) 58 (H) x 45 (W) x 30.5 (D), from base to top of control terminal 45 (D) 82

Solid State elays Series Q Panel Mount elays 1 Pole Panel Mount elay, 3-32V DC Control, 600V AC Output Specifications 50 Amp 90 Amp Catalog Number Price Catalog Number Price Q-50-60-D-1-4 76.19 Q-90-60-D-1-4 106.35 Input Voltage ange 3-32V DC 3-32V DC Turn-on Voltage (min.) 2.7V DC 2.7V DC Turn-off Voltage (max.) 1V DC 1V DC Consumption 13mA @ 32V 13mA @ 32V everse Voltage < 36V DC < 36V DC Output Amp ating AC51 50 90 Nominal Voltage 48 600V AC 48 600V AC Maximum Voltage 40 660V AC 40 660V AC Zero Switching Voltage 40V 40V Frequency ange 45 65 Hz 45 65 Hz Dimension (mm) 58 (H) x 45 (W) x 30.5 (D), from base to top of control terminal 45 (D) 1 Pole Panel Mount elay, 20-260V AC Control, 600V AC Output Specifications 50 Amp 90 Amp Catalog Number Price Catalog Number Price Q-50-60-A-1-4 82.54 Q-90-60-A-1-4 115.08 Input Voltage ange 20 260V AC 20 260V AC Turn-on Voltage (min.) 15V AC 15V AC Turn-off Voltage (max.) 6V AC 6V AC Consumption 8mA @ 260V AC 8mA @ 260V AC Output Amp ating AC51 50 90 Nominal Voltage 48 600V AC 48 600V AC Maximum Voltage 40 660V AC 40 660V AC Zero Switching Voltage 40V 40V Frequency ange 45 65 Hz 45 65 Hz Dimension (mm) 58 (H) x 45 (W) x 30.5 (D), from base to top of control terminal 45 (D) Q elays are cu (E243386). Not CSA. 83

Solid State elays Series TS DIN-rail Mounted elays 1 Pole DIN-ail Mount elay, 6-32V DC Control, 600V AC Output Specifications 15 Amp 25 Amp 40 Amp 50 Amp Catalog Number Price Catalog Number Price Catalog Number Price Catalog Number Price TS-15/60-D-0 86.51 TS-25/60-D-0 96.83 TS-40/60-D-0 116.67 TS-50/60-D-0 211.11 Input Voltage ange 6-32V DC 6-32V DC 6-32V DC 6-32V DC Turn-on Voltage (min.) > 5.1V DC > 5.1V DC > 5.1V DC > 5.1V DC Turn-off Voltage (max.) < 3V DC < 3V DC < 3V DC < 3V DC Consumption 10mA @ 32V 10mA @ 32V 10mA @ 32V 10mA @ 32V everse Voltage < 36V DC < 36V DC < 36V DC < 36V DC Output Amp ating AC51 15 25 40 50 Nominal Voltage 24 600V AC 24 600V AC 24 600V AC 24 600V AC Maximum Voltage 20 660V AC 20 660V AC 20 660V AC 20 660V AC Zero Switching Voltage < 20V < 20V < 20V < 20V Frequency ange 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz Dimension (mm) 100 (H) x 24 (W) x 107 (D) 108 (H) x 35 (W) x 142 (D) 108 (H) x 60 (W) x 142 (D) 108 (H) x 60 (W) x 142 (D) 1 Pole DIN-ail Mount elay, 20-260V AC Control, 600V AC Output Specifications 15 Amp 25 Amp 40 Amp 50 Amp Catalog Number Price Catalog Number Price Catalog Number Price Catalog Number Price TS-15/60-A-0 94.44 TS-25/60-A-0 102.38 TS-40/60-A-0 128.57 TS-50/60-A-0 218.25 Input Voltage ange 20 260V AC/DC 20 260V AC/DC 20 260V AC/DC 20 260V AC/DC Turn-on Voltage (min.) 15V AC/DC 15V AC/DC 15V AC/DC 15V AC/DC Turn-off Voltage (max.) 6V AC/DC 6V AC/DC 6V AC/DC 6V AC/DC Consumption 8mA @ 260V AC/DC 8mA @ 260V AC/DC 8mA @ 260V AC/DC 8mA @ 260V AC/DC Output Amp ating AC51 15 25 40 50 Nominal Voltage 24 600V AC 24 600V AC 24 600V AC 24 600V AC Maximum Voltage 20 660V AC 20 660V AC 20 660V AC 20 660V AC Zero Switching Voltage < 20V < 20V < 20V < 20V Frequency ange 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz Dimension (mm) 100 (H) x 24 (W) x 107 (D) 108 (H) x 35 (W) x 142 (D) 108 (H) x 60 (W) x 142 (D) 108 (H) x 60 (W) x 142 (D) 84

Solid State elays Series TS DIN-rail Mounted elays 1 Pole DIN-ail Mount elay, 6-32V DC Control, 600V AC Output Specifications 60 Amp 75 Amp 90 Amp 120 Amp Catalog Number Price Catalog Number Price Catalog Number Price Catalog Number Price without integrate fan (not required) TS-60/60-D-0 262.70 TS-75/60-D-0 312.70 TS-90/60-D-0 552.38 with integrated fan 230V TS-120/60-D-0-VEN-90 654.76 with integrated fan 115V TS-120/60-D-0-VEN-91 654.76 Input Voltage ange 6-32V DC 6-32V DC 6-32V DC 6-32V DC Turn-on Voltage (min.) > 5.1V DC > 5.1V DC > 5.1V DC > 5.1V DC Turn-off Voltage (max.) < 3V DC < 3V DC < 3V DC < 3V DC Consumption 10mA @ 32V 10mA @ 32V 10mA @ 32V 10mA @ 32V everse Voltage < 36V DC < 36V DC < 36V DC < 36V DC Output Amp ating @ 40ºC 60 75 90 120 Nominal Voltage 24 600V AC 24 600V AC 24 600V AC 24 600V AC Maximum Voltage 20 660V AC 20 660V AC 20 660V AC 20 660V AC Zero Switching Voltage < 20V < 20V < 20V < 20V Frequency ange 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz Dimension (mm) 108 (H) x 80 (W) x 107 (D) 108 (H) x 127 (W) x 142 (D) 108 (H) x 127 (W) x 142 (D) 108 (H) x 127 (W) x 158 (D) 1 Pole DIN-ail Mount elay, 20-260V AC Control, 600V AC Output Specifications 60 Amp 75 Amp 90 Amp 120 Amp Catalog Number Price Catalog Number Price Catalog Number Price Catalog Number Price without integrate fan (not required) TS-60/60-A-0 276.19 TS-75/60-A-0 319.84 TS-90/60-A-0 564.29 with integrated fan 230V TS-120/60-A-0-VEN-90 672.22 with integrated fan 115V TS-120/60-A-0-VEN-91 672.22 Input Voltage ange 20 260V AC/DC 20 260V AC/DC 20 260V AC/DC 20 260V AC/DC Turn-on Voltage (min.) 15V AC/DC 15V AC/DC 15V AC/DC 15V AC/DC Turn-off Voltage (max.) 6V AC/DC 6V AC/DC 6V AC/DC 6V AC/DC Consumption 8mA @ 260V AC/DC 8mA @ 260V AC/DC 8mA @ 260V AC/DC 8mA @ 260V AC/DC Output Amp ating @ 40ºC 60 75 90 120 Nominal Voltage 24 600V AC 24 600V AC 24 600V AC 24 600V AC Maximum Voltage 20 660V AC 20 660V AC 20 660V AC 20 660V AC Zero Switching Voltage < 20V < 20V < 20V < 20V Frequency ange 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz Dimension (mm) 108 (H) x 80 (W) x 107 (D) 108 (H) x 127 (W) x 142 (D) 108 (H) x 127 (W) x 142 (D) 108 (H) x 127 (W) x 158 (D) TS elays are cul (E243386) 85

Solid State elays Series TZ DIN-rail Mounted elays 3 Pole DIN-ail Mount elay, 5-32V DC Control, 600V AC Output Specifications 25 Amp 40 Amp 55 Amp Without integrated fan (not required) TZ25/60-D-0 242.06 Catalog Number Price Catalog Number Price Catalog Number Price with integrated fan 230V AC TZ40/60-D-0-VEN-90 277.78 TZ55/60-D-0-VEN-90 325.40 with integrated fan 115V AC TZ40/60-D-0-VEN-91 277.78 TZ55/60-D-0-VEN-91 325.40 Input Voltage ange 5-32V DC 5-32V DC 5-32V DC Turn-on Voltage (min.) > 4.5V DC > 4.5V DC > 4.5V DC Turn-off Voltage (max.) 3V DC 3V DC 3V DC Consumption 18 ma @ 5V DC - 22mA @ 32V DC 18 ma @ 5V DC - 22mA @ 32V DC 18 ma @ 5V DC - 22mA @ 32V DC everse Voltage < 36V DC < 36V DC < 36V DC Output Amp ating AC51 40 40 55 Nominal Voltage 24 600V AC 24 600V AC 24 600V AC Maximum Voltage 24 660V AC 24 660V AC 24 660V AC Zero Switching Voltage < 20V < 20V < 20V Frequency ange 50/60 Hz 50/60 Hz 50/60 Hz Dimension (mm) 100 (H) x 24 (W) x 107 (D) 108 (H) x 35 (W) x 142 (D) 108 (H) x 60 (W) x 142 (D) 3 Pole DIN-ail Mount elay, 20 260V AC Control, 600V AC Output Specifications 25 Amp 40 Amp 55 Amp Without integrated fan (not required) TZ25/60-A-0 271.43 Catalog Number Price Catalog Number Price Catalog Number Price with integrated fan 230V AC TZ40/60-A-0-VEN-90 311.11 TZ55/60-A-0-VEN-90 364.29 with integrated fan 115V AC TZ40/60-A-0-VEN-91 311.11 TZ55/60-A-0-VEN-91 364.29 Input Voltage ange 20 260V AC/DC 20 260V AC/DC 20 260V AC/DC Turn-on Voltage (min.) 15V AC/DC 15V AC/DC 15V AC/DC Turn-off Voltage (max.) 6V AC/DC 6V AC/DC 6V AC/DC Consumption 8mA @ 260V AC/DC 8mA @ 260V AC/DC 8mA @ 260V AC/DC Output Amp ating @ 40ºC 60 60 55 Nominal Voltage 24 600V AC 24 600V AC 24 600V AC Maximum Voltage 24 660V AC 24 660V AC 24 660V AC Zero Switching Voltage < 20V < 20V < 20V Frequency ange 50/60 Hz 50/60 Hz 50/60 Hz Dimension (mm) 100 (H) x 24 (W) x 107 (D) 108 (H) x 35 (W) x 142 (D) 108 (H) x 60 (W) x 142 (D) TZ elays are cu (E243386). Not CSA. 86

Solid State elays Accessories Accessories Heatsinks Description Catalog Number Price Heatsink Extruded aluminum DIN-rail mount for mounting one Q relay. Includes PAN-1 kit attachment for panel mounting. - For use with Q 15A & 25A relays - 100 x 24 x 65mm - Thermal esistance th > 2.8 K/W DIS-25D 76.98 DIS-25D DIS-50 - For use with Q 25A & 50A relays - 100 x 60 x 100mm DIS-50 76.98 - Thermal esistance th > 8.3 K/W Heatsink Extruded aluminum DIN-rail mount for mounting one Q relay. Includes PAN-1 kit attachment for panel mounting. - For use with Q 50A relays - 100 x 80 x 100mm - Thermal esistance th > 0.66 K/W Heatsink Extruded aluminum DIN-rail mount for mounting one Q relay. Includes PAN-1 kit attachment for panel mounting. - For use with Q 90A relays - 100 x 126 x 100mm - Thermal esistance th > 0.56 K/W Kit Attachment Allows for panel mounting the TS Series and DIS heat sinks. Includes 2 plastic supports, 2 screws, and 2 washers. Silicone thermoconductive paste for coupling the Q elay power module to the heat sink. 100 g tube. DIS-60 91.27 DIS-90 115.08 PAN-1 15.08 SIL-1 65.08 raphite Film 35 x 55 mm graphite film for Q relays. - 0.12 mm thick, 2.1 W (m*k). - 200 x 240 mm sheet with 25 adhesives SIL-Q 62.70 Accessory Description Catalog Number Price DIN-rail - 2 meter lengths (6 6 ) Top Hat, low profile (price per rail) Top Hat, high profile (package of 20, price per rail) 3F 3AF See page N30 87

Solid State elays Cross eference Cross eference Series SA/SAS to Sprecher+Schuh efran Catalog Number Catalog Number efran Product Status SA Series DIN-ail Mount SA6-25-1D TS-25/60-D-0 SA6-25-1 TS-25/60-A-0 SA6-40-1D TS-40/60-D-0 SA6-40-1 TS-40/60-A-0 SA6-50-1D TS-50/60-D-0 SA6-50-1 TS-50/60-A-0 SA6-75-1D TS-75/60-D-0 SA6-75-1 TS-75/60-A-0 SA6-100-1D TS-90/60-D-0 Select TS-120/60-D... For above 90A+ SA6-100-1 TS-90/60-A-0 Select TS-120/60-A... For above 90A+ ~ TS-120/60-D-0-VEN* New 120A offering ~ TS-120/60-A-0-VEN* New 120A offering SA6-30-3D TZ25/60-D-0 Select TZ40/60-D-0-VEN* for above 25A+ SA6-30-3 TZ25/60-A-0 Select TZ40/60-A-0-VEN* for above 25A+ ~ TZ40/60-D-0-VEN* New 40A offering ~ TZ40/60-A-0-VEN* New 40A offering ~ TZ55/60-D-0-VEN* New 55A offering ~ TZ55/60-A-0-VEN* New 55A offering SAS Series Panel Mount SAS3-10-1D Q-15-24-D-1-4 SAS3-10-1 Q-15-24-A-1-4 SAS3-25-1D Q-25-24-D-1-4 SAS3-25-1 Q-25-24-A-1-4 SAS3-50-1D Q-50-24-D-1-4 SAS3-50-1 Q-50-24-A-1-4 SAS3-75-1D Q-90-24-D-1-4 SAS3-75-1 Q-90-24-A-1-4 SAS6-50-1D Q-50-60-D-1-4 SAS6-50-1 Q-50-60-A-1-4 SAS6-75-1D Q-90-60-D-1-4 SAS6-75-1 Q-90-60-A-1-4 * Suffix code for selected fan voltage 88

Application Notes eneral Application Notes Heatsinks Different models of heatsinks have been designed and tested to meet size and dimension needs. How to choose a heatsink Set max. air temperature inside the panelboard (Tmax a ) Set max. operating current: Imax = Inom. load + 10% Draw on the graphs Tmax a, Imax points. Choose the smallest heatsink (starting from upwards), which point [Tmax a Imax] is in the gray working area of dissipation curves espect installation distances Installation In order to obtain best reliability, it is important to install a heatsink correctly inside the panel, to reach an adequate thermal exchange between the device and the surrounding air in natural convection conditions. How to install it correctly: Mount it vertically ( max. 10 inclination from the vertical axis) Vertical distance between a heatsink and the panel wall: 100 mm at leas. Horizontal distance between a heatsink and the panel wall: 20 mm at least. Vertical distance between two heatsinks: 300 mm at least. Horizontal distance between two heatsinks: 40 mm at least. MAX 10 MAX Check that cable channels do not 10 reduce these distances; should it happen, mount the relays overhanging from the panel, so that the air can flow vertically on the heatsink without obstables (see Fig.1). > 20 > 20 > 20 > 20 > 20 > 20 > 20 > 20 Fig. 1 > 20 > 20 > 20 > 20 > 20 Channel > 100 > 100 AI FAN > 40 > 40 Channel > 40 > 100 > 100 AIA AI FAN Channel Channel Channel Channel Channel Channel > 300 > 300 > 100 Channel Channel FAN > 20 VFAN AI 89

Application Notes eneral Application Notes (continued) Dissipation Curves Effective current controllable based on room temperature DIS 25D Controlled effective current (A) 25 20 15 10 5 0 20 30 40 50 60 70 80 90 100 oom temperature ( C) h = 100mm th = 2.8 C/W (*) 35 54.5 DIS 50 DIS 60 Controlled effective current (A) Controlled effective current (A) 50 40 30 20 10 0 20 30 40 50 60 70 80 90 100 oom temperature ( C) 80 60 40 20 0 20 30 40 50 60 70 80 90 100 oom temperature ( C) h = 100mm th = 0.83 C/W (*) h = 100mm th = 0.66 C/W (*) 60 80 100 100 With fans DIS 90 Controlled effective current (A) 120 100 80 60 40 20 0 20 30 40 50 60 70 80 90 100 oom temperature ( C) h = 100mm th = 0.56 C/W (*) 126.6 100 90

Application Notes eneral Application Notes (continued) Varistors (MOV) If your application is located near inductive loads, or shares power sources with large inductive loads that are creating transients in excess of the blocking voltage of the efran solid state relay, then you must install a metal oxide varistor (MOV) to protect the solid state relay. It is up to the installation company to properly size the MOV to the application! Ideally, the MOV protection is near the noise generating inductive load (such as a motor, drive, or other large inductive coil) or you can place MOVs directly across the output terminals of the SS. ecommended MOVs from EPCOS: Part Number S20K300 S20K420 S20K510 Working Voltage (V) 120-290 V AC 291-400 V AC 401-500 V AC The efran solid state relays include technology that dramatically reduces your need to install an external MOV except in extremely noisy environments or inductive load applications. Fuses and Fuse Holders These fuses ensure the maximum safety in solid state relay applications. Fuses with a very high cutoff power are used for this kind of applications. See Table 1. Table 1. Type relay ecommended Fuses (by others) for Q, TS & TZ elays i²t Q 15A 450 TS 25A Q 25A 645 450 TS 40A 1010 TS 50A Q 50A 6600 TS 60A 6600 TS 75A 8000 TS 90A Q 90A 11200 TS 120A 11200 TZ 25A 450 645 TZ 40A 1010 TZ 55A 6600 Nominal voltage 230 480 230 480 600 230 480 230 480 600 230 480 600 230 480 230 480 600 230 480 600 400 480 480 600 480 600 Size Dimensions (mm) Bussman Part No. 16A 10x38 FWC16A10F 25A 10x38 FWC25A10F 40A 14x51 FWP40A14 63A 22x58 FWP63A22F 80A 22x58 FWP80A22F 80A 22x58 FWP80A22F 100A 22x58 FWP100A22F 125A 0-0-0-TN/80 100x51x30 17OM1418000- TN/80 25A 12x32 FWC25A10F 40A 14x51 FWP40A14 63A 22x58 FWP63A22F (*) PF for fuseholders: LEAND, PFI for fuseholders: ITALWEBE 91

Application Notes eneral Application Notes (continued) Series Q Installation notes The heat sink must be grounded. Power controllers are designed to assure a switching function that does not include protection of the load line or of devices connected to it. The customer must provide all necessary safety and protection devices in conformity to current electrical standards and regulations. Protect the solid state relay by using an appropriate heat sink (accessory). The heat sink must be sized according to room temperature and load current. Dissipated Power Calculation Single-phase relay Pd Q..15/25 = 1.45 * IMS [W] Pd Q..50/90 = 1.35 * IMS [W] IMS = single-phase load current Heatsink Thermal esistance Calculation th = (90 C - max amb. T) / Pd where Pd = dissipated power Max. amb. T = max air temperature inside the electrical cabinet. Use a heatsink with thermal resistance inferior to the calculated one (th). Maximum surrounding air temperature 40 C suitable for use in pollution degree 2 or better. Procedure for mounting on heat sink: The module-heat sink contact surface must have a maximum planarity error of 0.05mm. and maximum roughness of 0.02mm. The fastening holes on the heat sink must be threaded and countersunk. Attention: spread 1 gram of thermoconductive silicone (we recommend DOW CONIN 340 HeatSink) on the dissipative metal surface of the module. The surfaces must be clean and there must be no impurities in the thermoconductive paste. As alternative it is also possible to use the graphite film SIL-Q available as accessory. Alternately tighten the two fastening screws until reaching a torque of 0.4...0.6 Nm. Wait 5 minutes for any excess paste to drain. Alternately tighten the two fastening screws until reaching a torque of 1.2...1.4 Nm. Installation on sink: 92

Application Notes eneral Application Notes (continued) Series TS Installation notes Power controllers are designed to assure a switching function that does not include protection of the load line or of devices connected to it. The customer must provide all necessary safety and protection devices in conformity to current electrical standards and regulations. To assure maximum reliability, it is essential to install the unit correctly in the panel in order to guarantee adequate heat exchange between the heat sink and the room under natural convection conditions. Maximum surrounding air temperature 40 C Open Type Equipment suitable for use in pollution degree 2 or better. Install the unit vertically (max 10 inclination from vertical axis). Vertical distance between unit and panel wall >100 mm Horizontal distance between unit and panel wall at least 20 mm Vertical distance between one unit and the next at least 300 mm Horizontal distance between one unit and the next at least 20 mm Make sure that the wire raceways do not reduce such distances. If they do, install the units cantilevered to the panel so that air can flow vertically onto the heat sink without obstruction. Equipment should be short circuit protected by semiconductor fuse type: Model TS 15/230 TS 25/60 TS 40/230, TS 40/60 TS 50/230, TS 50/60 TS 60/230, TS 60/60, TS 75/230, TS 75/60 TS 90/230, TS 90/60 TS 120/230, TS 120/60 Fuse manufacturer Bussmann Div Cooper (UK) Ltd Bussmann Intn'l Inc. USA Fuse Model size FWC16A10F 10x38 FWC25A10F 10x38 FWP40A14F 14x51 FWP63A22F 22x58 FWP80A22F 22x58 FWP100A22F 22x58 170M1418 000-TN/80 Series TZ Installation notes Power controllers are designed to assure a switching function that does not include protection of the load line or of devices connected to it. The customer must provide all necessary safety and protection devices in conformity to current electrical standards and regulations. To assure maximum reliability, it is essential to install the unit correctly in the panel in order to guarantee adequate heat exchange between the heat sink and the room under natural convection conditions. Install the unit vertically (max 10 inclination from vertical axis). Vertical distance between a heatsink and panel wall >100 mm Horizontal distance between a heatsink and panel wall at least 20 mm Vertical distance between two heatsink at least 300 mm Horizontal distance between two heatsink at least 20 mm Make sure that the cable raceways do not reduce such distances. If they do, install the TZ overhanging from the panel, so that the air can flow vertically on the heatsink without obstruction. Warnings During continuous operation, the heat sink can reach very high temperatures, and keeps a high temperature even after the unit is turned off due to its high thermic inertia. DO NOT work on the power section without first cutting out electrical power to the panel. Follow the instructions in the technical manual. 93

Technical Information Series Q Solid State elays Technical Information Q-15-24-... Q-25-24-... Q-50-24-... Q-90-24-... Q-50-60-... Q-90-60-... Amp ating AC51 [A rms] 15 25 50 90 50 90 AC53 [A rms] 3 5 15 20 15 20 Min. load current [A rms] 0.1 0.3 0.3 0.5 0.3 0.5 epetitive overcurrent (t = 1s) [A rms] 35 60 125 150 125 150 Non-repetitive overcurrent (t = 20 s) [A p] 200 300 600 1500 600 1500 Current drop at nominal voltage and frequencies [ma rms] 8 8 8 10 8 10 I 2 t for fusing (t = 1-10 ms) [A 2 s] 200 450 1,800 11,200 1,800 11,200 Critical dl/dt [A/µs] 100 100 100 100 100 100 Voltage drop at nominal current [V rms] 1.45 1.45 1.35 1.35 1.35 1.35 Critical dv/dt off state [V/µs] 1000 1000 1000 1000 1000 1000 I th [A] 15 25 50 90 50 90 Input DC Control Voltage ange 3-32V DC Turn-on Voltage (min.) Turn-off Voltage (max.) Consumption everse Voltage 2.7V DC 1V DC 13mA @ 32V < 36V DC AC Control Voltage ange 20 260V AC/V DC Output Turn-on Voltage (min.) Turn-off Voltage (max.) Consumption 15V AC/V DC 6V AC/V DC 8mA ac/cc @ 260V AC/V DC Nominal Voltage 24 230V AC 48 600V AC Maximum Voltage 20 253V AC 40 660V AC Non-repetitive Voltage 600Vp 1200Vp Zero Switching Voltage 20V 40V Frequency ange 45 65 Hz 45 65 Hz Insulation Nominal voltage input/output [V ac] 4000 output/case [V ac] 2500 esistance input/output [Ω] 10 10 output/case [Ω] 10 10 Capacity input/output [pf] 8 output/case [pf] 100 Ambient Conditions Ambient temperature -25 +80ºC [-13 176ºF] Storage temperature -55 +100ºC [-67 212ºF] Maximum relative humidity 50% at 40ºC Maximum installation altitude 2000 m above sea level Pollution level 3 Thermal Features Junction temperature 125ºC [257ºF] th junction/ambient [K/W] 12 12 12 12 12 12 junction/case [K/W] 1.25 1.25 0.65 0.30 0.65 0.30 Heatsink th = (90ºC - max amb. T / Pd ) Where Pd = dissipated power Max. amb. T = max. air temperature inside the electrical cabinet Use a heatsink with thermal resistance less than the calculated th value 94

Technical Information Series Q Solid State elays Terminals and Leads Power Terminals Command Terminals Terminal Type Screw (m4) contact area (LxP) 13 x 11 mm screw M2.5 MOS4 (22 16 AW) ecommended Fuses (by others) Model Q15... Q25... Q50... Q90... Size I 2 T 16A 150A 2 S 25A 390A 2 S 375A 2 S 50A 1800A 2 S 50A 1600A 2 S 80A 6600A 2 S 100A 12500A 2 S HIH SPEED FUSES Bussman Part No. FWC16A10F 338470 FWC25A10F 338474 FWC25A14F 338130 FWC50A14F 338079 FWC50A22F 338127 FWP80A22F 338199 FWP100A22F 338478 Dissipated power @ In 3,5W 6W 7W 9W 9,5W 14W 16W 95

Technical Information Series Q Solid State elays Heatsink / Thermal esistance Model Q15... Q25... efran Heatsink (see accessories) DIS 25D DIS 50 Thermal esistance th 2,8 K/W th 0,83 K/W Q50... DIS 50 th 0,83 K/W Q90... DIS 90 th 0,56 K/W Data relating to 40 C ambient temperature, heatsink in vertical position with 15 cm of free air above and below. Section Cable Model Q15... Q25... Q50... Q90... Section 2.5mm 2 / 14 AW 6mm 2 / 10 AW 12mm 2 / 7 AW 25mm 2 / 4 AW Minimum allowed rated section based on the rated currents of the power solid state relays, for copper leads isolated in PVC in continuous use and at room temperature of 40 C, according to standards CEI 44-5, CEI 17-11, IEC 408 pursuant to standard EN60204-1. Power terminals in compliance with standard EN60947-1 EMC Emission EN 61000-6-4 Emissions conducted at radiofrequency Class A (Industrial devices) EN 61000-6-4 Emissions irradiated at radiofrequency Class A (Industrial devices) The product is designed for type A environments. Use of the product in type B environments may cause undesired electromagnetic noise. In this case, the user should take appropriate steps for improvement. EMC Immunity EN 61000-6-2 Immunity for industrial environments EN 61000-4-2 Electrostatic discharges 4kV by contact; 8 kv in air. Performance criterion 2 EN 61000-4-6 Electromagnetic field at radiofrequency Test level 3. Performance criterion 1 0.15-80MHz EN 61000-4-3 Electromagnetic field at radiofrequency Test level 10V/m. Performance criterion 1 80-1000MHz EN 61000-4-4 Immunity to burst Test level 2kV/100 KHz. Performance criterion 2 EN 61000-4-5 Immunity to surge Test level: 2kV (Phase-ground); 1kV (Phase-phase). Performance criterion 2 Safety EN 61010-1 Safety requirements 96

Technical Information Series TS Solid State elays Technical Information Amp ating TS-15 TS-25 TS-40 TS-50 TS-60 TS-75 TS-90 TS-120 ated Current @ 40ºC (continuous service) [A rms] 15 25 40 50 60 75 90 120 Non-repetitive overcurrent (t = 20 ms) [A] 400 400 600 1150 1150 1300 1500 1500 I 2 t for blowout [A 2 s] 450 645 1010 6600 6600 8000 11,200 11,200 dv/dt critical with output deactiviated [V/µs] 1000 1000 1000 1000 1000 1000 1000 1000 Input DC Control Voltage ange 6-32V DC Output Turn-on Voltage (min.) Turn-off Voltage (max.) Consumption everse Voltage > 5.1V DC < 3V DC 10mA @ 32V < 36V DC AC Control Voltage ange 20 260V AC/DC Turn-on Voltage (min.) Turn-off Voltage (max.) Consumption Nominal Voltage Maximum Voltage Non-repetitive Voltage Zero Switching Voltage Frequency ange 15V AC/DC 6V AC/DC 8mA @ 260V AC/DC 24 600V AC 20 660V AC 500Vp for 230V models, 1200Vp for 480V models < 20V 50/60 Hz Isolation ated voltage input/output [V ac] 4000 Ambient Conditions Ambient temperature 0º +80ºC [32º +176ºF] according to dissipation curves Storage temperature -20 +85ºC [-4º +185ºF] Maximum relative humidity 50% at 40ºC Maximum installation altitude 2000m above sea level Pollution level 3 Dissipation Curves I (A) 40 35 30 25 20 15 10 TS 15-25 TS 40-50 - 60 TS 75-90 - 120 25 15 30 25 10 I (A) 70 60 50 40 30 20 10 60 50 40 50 40 30 20 15 I (A)( 120 90 75 90 50 30 0 40 80 T(C ) 0 40 80 T(C ) N.B.: Curves for the TS 120 refer to the device complete with standard running. 0 40 80 T(C ) 97

Technical Information Series TS Solid State elays Technical Information Terminal and Conductors Size 15/20A 25A 40A 50/60A 75-90A 120A Terminal Terminal: C = Control, P = Power, = round Terminal Types Contact area (WxD) screw type Type of preisolated terminal ➋ Max section. ➊ conductor tightening torque C 6.4x9 M3 1, 2, 4 6mm 2 / 10AW 0.6Nm max P 6.4x9 M3 1, 2, 4 6mm 2 / 10AW 0.4-0.6Nm 9x12 M5 1 6mm 2 / 10AW 1.3-1.8Nm C 6.4x9 M3 1, 2, 4 6mm 2 / 10AW 0.6Nm max P 6.4x9 M3 1, 2 6mm 2 / 10AW 0.4-0.6Nm 9x12 M5 1 6mm 2 / 10AW 1.3-1.8Nm C 6.3x9 M3 1, 2, 3 2.5mm 2 / 14AW 0.6Nm max P 12x12 M5 1, 2 16mm 2 / 6AW 1.5-2.2Nm 11.5x12 M5 1 16mm 2 / 6AW 1.5-2.2Nm C 6.3x9 M3 1, 2, 3 2.5mm 2 / 14AW 0.6Nm max P 16x18 M6 1, 2 50mm 2 / 0AW 3.5-6Nm 14x16 M5 1 50mm 2 / 0AW 1.8-2.5Nmm C 6.3x9 M3 1, 2, 3 2.5mm 2 / 14AW 0.6Nm max P 16x18 M6 1, 2 50mm 2 / 0AW 3.5-6Nm 14x16 M5 1 50mm 2 / 0AW 1.8-2.5Nmm C 6.3x9 M3 1, 2, 3 2.5mm 2 / 14AW 0.6Nm max P 16x18 M6 1, 2 50mm 2 / 0AW 3.5-6Nm 14x16 M5 1 50mm 2 / 0AW 1.8-2.5Nm 1. Eyelet 2. Fork 3. Tip 4. Faston ➊ The max. sections specified refer to unipolar copper wires isolated in PVC.. ➋ The screw terminals must be suitable for field wiring connection only when the wire is provided with eyelet tube terminal type 1. 98

Technical Information Series TZ Solid State elays Technical Information Amp ating TZ-25/60 TZ-40/60 TZ-55/60 TZ-40/60 TZ-55/60 Category AC51, AC53a [A rms] 25 40 55 40 55 Nominal current (Imax) [A rms] 3x25 3x40 3x55 3x40 3x55 Non-repetitive overcurrent (t = 20 ms) [A] 400 600 1150 600 1150 I 2 t for blowout [A 2 s] 645 1010 6600 1010 6600 DC Control Input Voltage Command Circuit (Uc) 5 32V DC Turn-on Voltage (min.) Turn-off Voltage (max.) Consumption > 4.5V DC < 3V DC 18mA @ 5V DC - 22mA @ 32V DC everse Voltage < 36V DC AC Control INPUT Voltage ange 20 260V AC/DC Activation Time Deactivation Time Turn-on Voltage (min.) Turn-off Voltage (max.) Consumption Frequency ange 15V AC/DC 6V AC/DC 8mA @ 260V AC/DC 50/60 Hz 1/2 cycle 1/2 cycle Critcal dv/dt OFF-state [V/µs] 1000 Potential drop at rated current [Vrms] 1.4 Peak Voltage Protection >1200V DC Isolation Nominal voltage (Ui) [V ac] 600 Insulation Nominal voltage input/output [KV ac] 4 Nominal inpulse withstand (Uimp) [V AC] 2500 Ambient Conditions Working temperature -20 +80ºC [-4º 176ºF] Storage temperature -20 +85ºC [-4º 185ºF] Maximum relative humidity 50% at 40ºC Maximum installation altitude 1000m asl Pollution level 3 (suitable for use in degree 2 environment) Class A (industrial device) IP20 Dissipation Curve TZ 25-40 - 55 I (A) 70 60 50 40 30 20 10 55 40 25 0 40 80 T ( C) 99

Technical Information Series TZ Solid State elays Technical Information Terminals and Conductors Size Nominal ➋ Section Cable mm 2 25A 6 40A 10 55A 16 Contact area (WxD) screw type 6.3x9 M3 Control Terminal (A1, A2, B1, B2 Type of preisolated terminal Eye / fork / tip Section conductor tightening torque ➊ min. 0.35 mm 2 max. 2.5 mm 2 0.6 Nm Max Contact area (WxD) screw type 12 x 12 M5 Power Terminal (L1, L2, L3, T1, T2, T3) Type of preisolated terminal Eye / fork / tip Max. section conductor tightening torque Tip Terminal min. 1mm 2 (17AW) max. 10mm 2 (7AW) Eye or Fork Terminal min. 1mm 2 (17AW) max. 16mm 2 (5AW) 1.5 2.2Nm round Terminal ➊ Contact area (WxD) screw type 12x12 self-tapping screw 3.9x12 DIN7981 12x12 M5 Max. section conductor tightening torque min. 1mm 2 (17AW) max. 16mm 2 (5AW) 1.5 1.8Nm min. 1mm 2 (17AW) max. 16mm 2 (5AW) 2.5Nm ➊ Note: The maximum sections specified refer to unipolar copper wires isolated in PVC. For the ground terminal, a eye wire terminal is required. (WxD) = Width x depth ➋ The minimum acceptable nominal section based on the nominal currents of the power solid state units is given for copper conductors isolated in PVC, under continuous operating conditions and at 40ºC ambient temperature according to standards CEI 44-5, CEI 17-11, IEC 408 in accordance with EN60204-1. Connection Examples L1 L2 L3 Alarm L1 L2 L3 A1+ TZ 40/60-D-0- VEN-90 fan:230vac AC51: 40A 600Vac T1 T2 T3 A2- AC53a: 8A 50/60Hz T1 T2 T3 On B1 B2 A1 5..32 Vdc A2 L1 : Phase 1 input L2 : Phase 2 input L3 : Phase 3 input T1 : Phase 1 output T2 : Phase 2 output T3 : Phase 3 output A1 : Control signal (+) A2 : Control signal (-) B1 : Alarm output (+) (Special unit) B2: Alarm output (-) (Special unit) Led1: ed led signal indicator Led2: Yellow led (alarm overtemperature junction) 100

Wiring Diagrams Solid State elays Series Q Solid State elays Connection of 3-phase load and 2-phase control Connection of single-phase load Heatsink (accessory) Connection of 3-phase load with closed/open triangle or star Digital output on/off elay output Series Q Fuse Connections The solid state group must be connected using proper fuses against short circuits 101

Wiring Diagrams Solid State elays Single-phase connection Series TS Solid State elays Three-phase Star connection with neutral Digital output Digital output + 6 32Vcc ON/OFF Control + - + 6 32Vcc ON/OFF Control + 6 32Vcc ON/OFF Control + 6 32Vcc ON/OFF Control + - ON AL Controller ON AL ON AL ON AL TS 60A/480 Vac TS 60A/480 Vac TS 60A/480 Vac Controller AC1 50/60 Hz AC1 50/60 Hz AC1 50/60 Hz TS 60A/480 Vac AC1 50/60 Hz Star Connection Load Line Load Line Load Line Load Line Fuse Fuse Fuse Load Fuse Phase Neutral round Neutral L1 L2 L3 round Three-phase Triangle or Star connection without neutral on two phases + 6 32Vcc ON/OFF Control ON AL + 6 32Vcc ON/OFF Control ON AL Digital output + - TS 60A/480 Vac AC1 50/60 Hz TS 60A/480 Vac AC1 50/60 Hz Controller Triangle connection Star connection Load Line Load Line Fuse Fuse L1 L2 L3 round 102

Wiring Diagrams Solid State elays Series TZ Solid State elays Three-phase Triangle or Star connection (with and without neutral) L1 L2 L3 Neutral round F1 F2 F3 I < 150mA * V < 30V Load L1 L2 L3 Alarm TZ 25/400-0-1 AC51: 25A AC53a: 5A 400Vac 50/60Hz L1 L2 L3 A1+ T1 T2 T3 A2- T1 T2 T3 On B1 B2 A1 5..32 Vdc A2 5-32Vdc Digital input >110 C Controller * Only in the version with option overtemperature alarm output 103

Dimensions Solid State elays Q Panel Mount elays Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. (*) See installation notes *Apply thermoconductive paste aise the guard to access the fastening hole or the terminals 104

Dimensions Solid State elays TS 1-Pole DIN-ail Mount elays Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. TS 15 TS 25 TS 40 TS 50 TS 60 TS 75 (without fan) TS 90 (without fan) TS 120 (with fan) 24 (0.95) 35 (1.38) 60 (2.36) 80 (3.15) 127 (5.0) + 6 32Vcc ON/OFF Contro l ON + 6 32Vcc ON/OFF Contro l ON + 6 32Vcc ON/OFF Contro l ON + 6 32Vcc ON/OFF Contro l ON + 6 32Vcc ON/OFF Contro l ON 30 (1.18) 108 (4.25) 100 (3.94) TS 25A/600 Va c AC1 50/60 Hz TS 40A/600 Va c AC1 50/60 Hz TS 50A/600 Va c AC1 50/60 Hz TS 60A/600 Vac AC1 50/60 Hz TS 60A/600 Va c AC1 50/60 Hz Load Line Load Line Load Line Load Line Load Line 14 (0.55) Depth = 107 (4.21) Weight = 320 g. Depth = 142 (5.59) Weight = 540 g. 18 (0.71) Depth = 142 (5.59) Weight = 900 g. The ON LED is red during operation, yellow if the thermal protection trips TS 1-Pole elays Depth = 142 (5.59) Weight = 1200 g. PAN-1 Panel Mount Accessory for TS - Hole Template Length mm (inches) Width mm (inches) Depth = 142 (5.59) Weight TS 75-90 = 1300 g. Weight TS 120 = 1700 g. 50 (1.97) max. TS-15 25 112 (4.41) 0 (0.00) TS-40 112 (4.41) 25 (0.98) TS-50 60 112 (4.41) 44 (1.73) TS-90 120 112 (4.41) 113 (4.45) 105

Dimensions Solid State elays TZ 3-Pole DIN-ail Mount elays 8 (0.31) 127 (5.0) 127 (5.0) 8 (0.31) 80 (3.14) 30 (1.18) L1 L2 L3 L1L2 L3 A1+ TZ 25/60-A-0-1 AC51: 25A 600Vac T1 T2 T3 A2- AC53a: 5A 50/60Hz T1 T2 T3 Alarm On B1 B2 A1 5..32 Vdc A2 L1 L2 L3 L1L2 L3 A1+ TZ 40/60-D-0- VEN-90 fan:230vac AC51: 40A 600Vac T1 T2 T3 A2- AC53a: 8A 50/60Hz T1 T2 T3 Alarm On B1 B2 A1 5..32 Vdc A2 30 (1.18) 100 (3.94) TZ25 TZ40 & TZ55 50 (1.97) Max 106