The X-ray circuit: part II

Similar documents
Product data Remote Controlled Table

MXHF-1500RF is controlled by Digital key panel console that displays KV, ma and mas with APR menu programmed.

Ultimate DR flexibility

C501-E029C. RADspeed. GENERAL RADIOGRAPHIC SYSTEM Automatic

P R E S E N T E D B Y. K A M A R U L A M I N A B D U L L A H Dip. MED. IMG., BSc. MED. IMG. (UiTM)

MULTIX PRO/TOP VERTIX PRO/TOP VERTIX Solitaire X-ray systems for radiographic rooms that make life easier

Luminos RF Classic. Where value meets performance.

FMT18 FLOOR MOUNTED SYSTEM

Digital Radiography System

OTC18 OVERHEAD TUBE CRANE SYSTEM

X-RAY IMAGING EE 472 F2017. Prof. Yasser Mostafa Kadah

C506-E064. Full digital system. Printed in Japan A-NS

Technical data CAMARGUE CS-VH50/300. VARIABLE Height Bucky Table With Ceiling Suspension

SPRINGFIELD TECHNICAL COMMUNITY COLLEGE ACADEMIC AFFAIRS

DR General Radiography System. DR Series

INNOVATION BY DESIGN. Toshiba A History of Leadership REMOTE CONTROL R/F SYSTEM

X-RAY DIAGNOSTIC EQUIPMENT

X-RAY DIAGNOSTIC EQUIPMENT

YSF - 300/DAR i

DRX SERIES. Radiographic Systems. Division of Carestream

Fully Integrated Digital Radiography Systems

AeroDR X60. Motorized X-ray System

universal Digital Radiography (DR) System

Tomosynthesis. Energy Subtraction. Long View Imaging

MULTIX PRO/TOP, VERTIX Solitaire, VERTIX PRO/TOP

Fully Integrated Digital Radiography Systems

Beam-Restricting Devices

RADspeed Pro GENERAL RADIOGRAPHIC SYSTEM Automatic C501-E027C

RADspeed Pro GENERAL RADIOGRAPHIC SYSTEM Automatic C501-E027B

The European Manufacturer Group. The European Manufacturer Group

X-RAYS - NO UNAUTHORISED ENTRY

Maximizing clinical outcomes

X-RAY MEDICAL EQUIPMENT

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

Institutional Information:

Dedicated Veterinary Imaging Solutions Digital, CR and Analog Imaging Solutions for any size patient and any size budget.

Digital radiography. bucky table and wall stand as a dual detector or wireless system. Amadeo DR Systems

VISION V FLOOR MOUNTED ТUBE SYSTEM

Q-Rad. Radiographic Systems

X-rays. X-rays are produced when electrons are accelerated and collide with a target. X-rays are sometimes characterized by the generating voltage

X-ray Tube and Generator Basic principles and construction

Introduction to Radiography

Nuclear Associates

NJDEP Medical Physicist s Radiographic QC Survey Registration Number:

DR _ solutions. We understand that customers don t need just products, they want. solutions

Teaching Digital Radiography and Fluoroscopic Radiation Protection

Ch. 223 VETERINARY MEDICINE CHAPTER 223. VETERINARY MEDICINE GENERAL PROVISIONS X-RAYS RADIOACTIVE MATERIAL. Authority

China Resources Wandong Medical Equipment Co., Ltd. High Frequency 50kW, 150kV Radiography System - HF50-R

see thoroughly, insure safety digital C-arm system Remote Compact Fully digital

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Some operation methods show in the catalog reguire optional eguipment

you can Portable DR with High Sensitivity. Less is more. CXDI-501C DIGITAL RADIOGRAPHY SYSTEM

Medical Imaging. Digital R/F remote controlled table. radiology ahead

Seminar 8. Radiology S8 1

Overview. Professor Roentgen was a Physicist!!! The Physics of Radiation Oncology X-ray Imaging

Exposure System Selection

The digital 2-in-1 solution for fluoroscopy and radiography. AXIOM Luminos drf.

Best choice in all DR. Jumong M. SG HealthCare Jumong M Digital radiography specifications

Remote Controlled R/F System C506-E056D

siemens.com/luminos-fusion Luminos Fusion The 2-in-1 system that fits your needs and fits your budget

X o- System. Chiro- Systems. Chiropractic X-Ray Systems and Digital Solutions. Digital Radiography Computerized Radiography Chiropractic Systems

Truly flexible to meet your clinical needs

Medical Imaging. Latest generation bucky room. system. radiology ahead

ddraura Series Productivity meets versatility

Nuclear Associates

you can Portable Digital Radiography. Going places. CXDI-501G DIGITAL RADIOGRAPHY SYSTEM

SONIALVISION G4 Multi-purpose Digital R/F System C506-E075

SONIALVISION G4 Multi-purpose Digital R/F System C506-E075

Nuclear Associates

RAD. Experiences Using the RADspeed Pro EDGE Package. 1. Hospital Description. 2. Background of Adoption. Hirohito Tanaka

SONIALVISION G4 Multi-purpose Digital R/F System

R&F X-ray systsem. Savings With Every Exposure

DIGITAL TABLE C506-E049E

Digital Imaging Considerations Computed Radiography

Nuclear Associates

1. Carlton, Richard R., and Arlene M. Adler. Principles of Radiographic Imaging: An Art and a Science, 5th edition (2013).

RADspeed Pro DIGITAL RADIOGRAPHIC SYSTEM. IBD-RADProAeroDR

Nuclear Associates , , , , , ,

CHAPTER 6 QC Test For Fluoroscopic Equipment. Prepared by:- Kamarul Amin bin Abu Bakar School of Medical Imaging KLMUC

Diagnostic Imaging Equipment & Consumables. Patient Positioning

Veterinary Science Preparatory Training for the Veterinary Assistant. Floron C. Faries, Jr., DVM, MS

Get more from your images with Symphony Image Processing

Digital Radiography X-Ray System. X Twin with X Mobil Roesys GmbH [rshsmi] 1/11

ddraura Series Productivity meets versatility

Minnesota Rules, Chapter 4732 X-ray Revision

DENTAL RADIOGRAPHY KAMARUL AMIN BIN ABU BAKAR

SPRINGFIELD TECHNICAL COMMUNITY COLLEGE ACADEMIC AFFAIRS

Quality imaging, practical investment. Philips DuraDiagnost specifications

V SALAI SELVAM, AP & HOD, ECE, Sriram Engg. College, Perumalpattu 1 MEDICAL ELECTRONICS UNIT IV

SECTION I - CHAPTER 1 DIGITAL RADIOGRAPHY: AN OVERVIEW OF THE TEXT. Exam Content Specifications 8/22/2012 RADT 3463 COMPUTERIZED IMAGING

Luminos drf Max. Taking 2-in-1 to the MAX in radiography and fluoroscopy. siemens.com/luminos-drf-max

RADspeed Pro. EDGEpackage C501-E041C

ECOVIEW 9 / ECOVIEW 9 PLUS Digital Radiographic System

Redefining Ergonomics

RULES OF TENNESSEE DEPARTMENT OF ENVIRONMENT AND CONSERVATION DIVISION OF RADIOLOGICAL HEALTH CHAPTER USE OF X-RAY APPARATUS

- KiloVoltage. Technique 101: Getting Back to Basics

Basic Circuitry and X ray Production. Lynn C. Sadler, MSRS, R.T.(R)(QM) President, WCEC, Inc.

BENNETT RENAISSANCE SERIES. Dedicated to Quality, Innovation and the Chiropractic Profession

ECOVIEW 9 / ECOVIEW 9 PLUS Digital Radiographic System

Simplifying Digital X-RAY FOR Chiropractic DIGITAL X-RAY RETROFIT COMPLETE DIGITAL X-RAY ACQUISITION & IMAGE MANAGEMENT

Transcription:

The X-ray circuit: part II By Dr. Mohsen Dashti 357 Radiologic Processing & Procedure Lecture notes #2

Key issues Types of x-ray equipment. Power for x-ray generator. A basic x-ray circuit. Generators.

Medical x-ray units can be classified as???? Medical x-ray units can be classified as diagnostic or therapeutic. Diagnostic units: 1. Designed for specific procedures, such as general procedures, fluoroscopy, head procedures, cardiac catheterization, etc. 2. All of these units operate within the diagnostic range (10-1200 ma, 0.001-10 s, and 25-150 kvp). 3. Can be classified as fixed units or portable units.

Therapeutic units: 1. Operate at much higher energies, ranging from 4-40 million electron-volts (mev). 2. For that they operate at low ma ranging below 20 ma and with time settings in the range of 1-60 minutes.

X-ray tables: - The radiographic table is designed to support the patient in a position that will enhance radiographic procedure. - Foam pads may be used for lengthy examination to offer comfort. - The tabletop must be uniformly radiolucent. Why? -- To easily permit x-rays to pass through. - The tables are commonly made of bakelite or similar surface except for specialized procedures as such angiography, carbon graphite fiber is used to reduce absorption of photons.

X-ray tables: - Most x-ray tables have flat tops shaped and some have curved tops. Why? -- Curved tops are used for fluoroscopic procedures because they are more comfortable for the patients and allow the body part to be closer to the x-ray film. Any problems? -- They are considered difficult to maintain a patient accurately in an oblique or lateral position. - The table must include space for a tray to hold film cassettes and a radiographic grid.

X-ray tables: - The tray is often called?... - Many tables include automatic exposure control sensors in the tray and some use a stationary tray with a movable tabletop. - Tables are available in fixed and tilting models. Why? -- Fixed: Do not permit tilting patient s head or feet. They are designed for radiographic work only. -- Tilting: They permit tilting up to 90 degrees used mainly for fluoroscopic procedures.

- Tilting tables include a footboard for patients to stand on when the table is upright. Why? -- The footboard is often used for gastrointestinal studies when the patient begins examination in a horizontal position. - Some procedures such as myelography require the patient to be tilted head down. This requires the use of shoulder supports. -- Handgrips give the patient an added feeling of security.

Tube supports: - They are designed to permit the x-ray tube to be manipulated and hold the tube immobile during exposure. - Tube suspensions are available in five versions: overhead, floor-to-ceiling, floor, mobile & C-arm. - Overhead suspension system can be angled up to 300 o arc around the tube column. Different angles can be locked into place by..? - Different manufacturers have various types of locks and detents.

The floor-to-ceiling system is mainly used for skull procedures and chest. The main disadvantage of this system is difficulty of tube manipulation.

Head unit: is a specialized adaptation of the floor-toceiling unit and is designed to enhance radiography of the cranium (skull) and facial bones. Any advantages? - It improves head radiography by regulating tube angles, decreasing the distance from the patient to the film and minimizing time to position the patient.

Upright units: they are upright film cassette holder or Bucky used mainly for chest radiography. What else? - They are also used for some skull radiographic procedures such as acromioclavicular joints, abdominal obstructive procedures, cervical spine, etc.

Power for x-ray generation The production of x-ray photons within an x-ray tube requires accelerating electrons capable of producing necessary speed. Where does that come from? A diagnostic x-ray generator is composed of numerous basic electrical devices that are connected in a sequence capable of this speedy electrons production. The power producing electricity to the x-ray generator is known as incoming line current and is supplied in the form of a three-phase power cycle. Nearly all x-ray equipment operates from an incoming line of 210-220 volts.

A basic x-ray circuit The basic x-ray circuit can be divided into??? 1. The main circuit. 2. The filament circuit. - The main circuit: it supplies the x-ray tube with properly modified power. - Its purpose is to produce x-rays. - The main circuit has 3 major functions: 1. Boost the voltage to the necessary range of x-ray production. 2. Permit the radiographer to adjust technical factors. 3. Incorporate appropriate circuitry to increase x-ray production efficiency.

A basic x-ray circuit A sequence of devices modifies the incoming line power to produce x-rays including: main breaker, exposure switch, autotransformer, timer circuit, high-voltage step-up transformer, four-diode rectification circuit, filament circuit, filament step-down transformer, x-ray tube and rotor stator. - The main switch and main breaker are enclosed in an electrical power box. - The exposure switch acts like a remote control, allowing current to flow through the circuit. -- It only allows the exposure to begin and not end. - It must be of the dead man type? Meaning and why?...

A basic x-ray circuit - The timer circuit is designed to end the exposure at accurately measured time. - The timer circuit can be of several types including: mechanical timers (not very accurate and capable of exposure only to 0.25 second), synchronous timers (can not be used for serial exposures), impulse timers, electronic timers (most common timers and capable of exposures as short as 0.001 second), and milliamperesecond timers. - Automatic exposure controls are used and will be discussed in later lectures.

A basic x-ray circuit - The filament circuit supplies the filament of the x-ray tube with properly modified power. -- Its main purpose is to create the appropriate thermioically emitted electron cloud at the filament. - The main circuit and filament circuit are combined to form the complete basic x-ray circuit that is composed of sequence of devices to produce x-rays.

A basic x-ray circuit The complete basic x-ray circuit & its components: Main breaker Exposure switch Autotransformer Timer circuit High-voltage step-up transformer Four-diode rectification circuit X-ray tube Rotor stator Filament circuit Filament stepdown transformer

A basic x-ray circuit The operating console has common diagnostic controls:

Generators Post holiday gift.. Briefly explain the difference between singlephase generators and three-phase generators.