Circuit diagram. Applications. Function. Function (Continued) Page 23 SNO 4062K /K-A /KM /KM-A

Similar documents
NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

P RODUCT C ATALOGUE 1/2002

02/11/2015

E-STOP relays, safety gate monitors

02/11/2015

New Products Catalogue 2009 Safety Relays ESR5

Online data sheet UE48-3OS2D2 UE48-3OS SAFETY RELAYS

Online data sheet UE48-2OS2D2 UE48-2OS SAFETY RELAYS

E-STOP relays, safety gate monitors

Safety relays - PSR-SCP- 24DC/ESD/4X1/

Safety Technique. Emergency Stop Module With Time Delay BH 5928, BI 5928

Safety Technique. SAFEMASTER Emergency Stop Module With Time Delay BH 5928, BI 5928

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

Phase sequence and phase failure monitor

Online data sheet UE45-3S13D33 UE45-3S1 SAFETY RELAYS

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

Online data sheet UE43-3AR3D2 UE43-3AR SAFETY RELAYS

Transformers, Power Supply Units and Socket Outlets

E-STOP relays, safety gate monitors

Datasheet - PROTECT-IE-02

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

PSR-SCP- 24DC/ESD/5X1/1X2/300

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

02/11/2015

Type CP-S, CP-C & CP-A Switch mode

Components for safety applications Preventa safety modules

Controls Contactors and Contactor Assemblies Special Applications

Switching power supplies CP range, Linear power supplies CP-L range. Content

PHOENIX CONTACT - 09/2009

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

For Immediate Delivery call KMParts.com at (866)

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

02/11/2015

Safety Technique. SAFEMASTER Emergency Stop Module LG 5925

Supplemental Motor Protection Devices Specifications

DZD 92 L. Wiring diagram. Time domains. Function. Dimensional drawing. Indicators. Accessories

Safety switches with slotted hole lever

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Relais und Automatisierungssysteme JUST IN TIME. with the. New Generation NGG. from Schleicher NGG CATALOGUE

Thermistor motor protection relays

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Supplemental Motor Protection Devices Specifications

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

EMD-FL-3V Phase Voltage Monitoring Relay INTERFACE. Data Sheet. Description

SINEAX B 811 Power Pack with additional Functions

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

MINI-PS AC/24DC/1.3

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Electronic Circuit Protector ESX10-T

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

QUINT-PS/ 3AC/24DC/10

Bulletin 100S-C/104S-C Safety Contactors. Bulletin 700S-CF Safety Control Relays. Table of Contents. Selection Guide

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

CM-IWM.11 Insulation monitoring relay

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

QUINT-PS-24DC/24DC/10

Easy measuring, reliable monitoring and flexible planning - the EMR, ETR and EMT relays

27/04/2015

Series P. Applications

S1 Minor (usually reversible) injury S2 Serious (normally irreversible) injury including death

CP-T range Product group picture

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

02/11/2015

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Subject to changes 11/2003 Page 1/7

RENF22R2MMW Zelio Timer Relay - Modular

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

Electronic timer CT-TGD.22

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

08/07/2015

3 - Protection components Circuit-breakers

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

QUINT-PS/ 3AC/24DC/40

Thermistor motor protection relays

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

02/11/2015

FM series position switches

Online data sheet UE10-3OS3D0 UE10-3OS SAFETY RELAYS

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Description Basic devices with positive operation contacts

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Solid-state Timer H3DS

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

QUINT-PS AC/24DC/40

PNOZ X3. } Safety relays. Operating Manual EN-08

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

IMPULSE SWITCH, REMOTE SWITCH

Transcription:

SNO 4062K Basic unit for emergency stop and guard door applications Basic unit as per DIN EN 60204-1 and EN ISO 13849-1 for single or twin channel emergency stop monitoring. PL e and category 4 as per EN ISO 13849-1 SILCL 3 as per DIN EN 62061 Stop category 0 as per DIN EN 60204-1 Manual or automatic start With/without cross short detection Feedback circuit for external contactor monitoring 2 enable circuits, 1 signal circuit For processing signals from the output signal switching devices (OSSD) of a light curtain, according to DIN EN 61496-1 For post-switching a switching mat according to DIN EN 1760-1 () Input debouncing () SNO 4062K /K-A /KM /KM-A Circuit diagram Applications Monitoring of separating protective equipment Monitoring of rollup gates For processing signals from the output signal switching devices (OSSD) of a light curtain according to DIN EN 61496-1 For connecting to a safety mat according to DIN EN 1760-1 () Function (Continued) Synchronous monitoring with twin-channel control, both safety channels are mutually monitored with synchronous time t S. Safety channel CH1 must close before CH2 and the bridge S33/S35 must be switched. If CH2 closes before CH1 the synchronous time t S =, the synchronous monitoring is switched off. The function corresponds to that of the SNO 4062K without synchronous monitoring. The unit is suitable for attaching to short-circuit forming switching mats, switching bars or switching corners in 4-conductor technology (without monitoring resistance). The unit must be operated in a twin-channel manner with cross short detection. At a resistance < 50 Ω / channel and a short-circuit between the channels (S11/S12 and S21/S22), the enable circuits open and the LED SUPPLY flashes. Input debouncing prevents rapid switching one after the other of the enable circuits if the safety inputs are opened shorter than t ASP. If the safety inputs are open longer than t ASP, this leads to opening the enable circuits after t R. Restarting is blocked for the period t SP. With applications for tactile operating modes (rapid off/on cycles, e.g. with manual feeding) we recommend input debouncing for the. Also, please observe the information provided by your professional association! Function SNO 4062K The unit is a twin-channel safety switch unit that is self-monitoring at every ON-OFF cycle, for emergency stop devices as per DIN EN 60204-1, which is fitted with a positively guided relay. Basic function: After application of the power supply to the terminals A1/A2 and closed safety inputs, actuation of the reset button (manual start) causes the enable circuits to be closed. The enable circuits are opened by opening/de-excitation of the safety inputs. Operating modes / system functions Single or twin channel control with single channel control the two safety channels CH1 and CH2 are in parallel and with twin channel control they are switched separately. Without cross short detection both safety channels are switched to plus potential (S12 and S31 to S11). With cross short detection the safety channel CH1 is switched to plus potential (S11 to S12) and the safety channel CH2 against minus potential (S21 to S22). Manual start Using a button, with the safety inputs closed, the reset input S34 is opened (triggering with falling flank) or the reset input S35 is closed (triggering with rising flank). Automatic start the reset input S35 is combined with S33. The unit starts with the rising flank of the signal at the safety input S12. Start blocking when applying the power supply and closed safety inputs, the enable circuits are not closed. The start can only be achieved after actuation of the reset button. For the start blocking, as with the manual start operating mode, the reset inputs must be actuated using a button. Restart blocking after opening and closing the safety inputs, no restart takes place. The restart can only be achieved after actuation of the reset button. For the restart blocking, as with the manual start operating mode, the reset inputs must be actuated using a button. OSSD compatible Output switch elements (OSSD) of a light curtain or other light sensors with semi-conductor outputs can be processed. Test pulses < t TP, do not influence the function of the unit. Test pulses > t TP the unit can interlock. Page 23

Function diagram Notes Proper use The devices are safety switching devices. They must only be used as components of safety equipment on machines for the purpose of protecting people, material and machines. The safety category according to EN 954-1 depends on the external circuitry, the choice of control devices and their placement on the machine. The indicated times must be observed when the device is operated, otherwise the device could lock. Locking can be released by properly opening the safety inputs. SNE expansion devices or external contactors with positively driven contacts can be used to multiply the enabling current paths. The device and the contacts must be protected with max. 6 A utilization category gg or through circuit breakers with trigger characteristic B or C. The devices are equipped with overload protection (for short circuit). After the cause of the malfunction has been removed, the device is operational again after approx. 3 s. Control output S11 is exclusively for connecting control devices as defined in the operating instructions and not for connecting external field devices such as lamps, relays or contactors. The devices must be installed in a control cabinet with a protection degree of at least IP 54. Please also note the information provided by your trade association. Connection circuit diagramm Dimension diagram SNO 4062K / SNO 4062K-A / -A Page 24

Installation Please consult the circuit diagram during installation. 1 Emergency stop single channel, manual start 1.1 RESET (with reset button monitoring S34) 1.2 Bridge 2 OSSD control two-channel, without cross monitoring, 2.1 Bridge, RESET with automatic start 2.2 Bridge, CH2-3 Emergency stop two-channel, with cross monitoring and manual start 3.1 RESET (with reset button monitoring S34) 3.2 Bridge, CH2 + 4 Safety gate applications two-channel, with cross monitoring, synchrocheck (S1 must be operated before S2) 4.1 RESET with automatic start 4.2 Bridge, CH2 + 5 2 enabling current paths 1 signaling contact 6 Supply voltage SNO 4062K Two-channel sliding safety gate monitoring with manual start Position switch LSE-02 from the company Moeller is used. Two-channel light curtain monitoring with manual start. Page 25

Two-channel sliding safety gate application (with cross monitoring) with manual start Channel 1 (S12) and channel 2 (S22) monitor the position of the sliding safety gate. The automatic start through terminal S35 activates the SNO 4062K /. If the sliding safety gate opens, K1 and K2 switch back into the OFF position (enabling current paths 13/14, 23/24 are opened). If the safety gate is closed again, the automatic start at terminal S35 activates the device again. Two-channel emergency stop application (with cross monitoring) with manual start and reset button monitoring The two-channel emergency stop application switches off the device even if one of the two contacts of emergency stop button does not open. If an error occurs (for example when the emergency stop contact connected to terminal S12 does not open), the second (redundant) contact S22 will activate safety circuit. The enabling current paths 13/14 and 23/ 24 open. In case of a short circuit in the lines leading to the emergency stop button, the voltage applied to S11, S21 is shortcircuited (cross monitoring). The relays K1, K2 switch back into the OFF position and the electronic fuse is triggered. If a line short circuit occurs in the reset button after the relay has been activated, this will be recognized by the cyclical self test when reactivating the device. This will inhibit the enabling current paths from closing again. Two-channel safety mat application (with cross monitoring) with manual start and reset button monitoring The safety mat connected to terminals S21, S22 and S11, S12 is monitored by means of cross monitoring. If the safety mat is not actuated (no one is stepping on it), the can be activated with the reset button. The enabling current paths 13/14, 23/24 close and the signaling current path 31/32 opens. If a person steps onto the safety mat, a short circuit is generated causing the immediate release of the K1 and K2 relays. The enabling current paths open and the signaling current path closes. Overview of devices / Part numbers Type Rated voltage Terminals Part no. SNO 4062K AC/DC 24 V 50-60 Hz screw terminals, fixed R1.188.0699.2 SNO 4062K-A AC/DC 24 V 50-60 Hz screw terminals, pluggable R1.188.0709.2 AC/DC 24 V 50-60 Hz screw terminals, fixed R1.188.0719.2 -A AC/DC 24 V 50-60 Hz screw terminals, pluggable R1.188.0729.2 Page 26

Technical data Power supply circuit SNO 4062K Nominal voltage U N AC/DC 24 V Rated power DC 2.0 W 2.1 W Rated power AC 2.4 W / 4.4 VA 2.5 W / 4.6 VA Ripple 2.4 V pp Nominal frequency 50... 60 Hz Operating voltage range 0.85... 1.1 x U N Fusing for control circuit supply short-circuit resistant (PTC resistance) short-circuit resistant (electronic fuse) Control circuit Nominal output voltage S11, S33 against S21 DC 22 V Output current / peak current 100 ma / 2000 ma 100 ma / 300 ma Input voltage range High DC 17.4 V to DC 26.4 V Low DC -3.0 V to DC +5.0 V Nominal current / peak current S12, S31/S22 40 ma / 100 ma Nominal current / peak current S34, S35 5 ma / 50 ma Permissible test pulse time t TP / test frequency 1000 s and 10 s -1 Response time t A1 S34 20 ms to 40 ms Response time t A2 S35 200 ms to 500 ms 20 ms to 80 ms Minimum switch-on duration t M S34, S35 > 50 ms Blocking time t SP --- 70 ms to 130 ms Block response time t ASP --- > 7 ms Reavailability time t W 40 ms 150 ms Fallback time t R K1, K2 < 25 ms Synchronous monitoring time t S approx. 200 ms -- Maximum resistance for short-circuit forming switching mats --- 50 inclusive connection lines Line resistance 70 Output circuit Enable circuits Contact allocation 2 NO, positively guided; B300; R300 Nominal switching voltage U n AC 240 V / DC 300 V Max. continuous current I n per circuit 240 V AC / 6 A; 24 V DC / 5 A Max. total current of all circuits 12 A Use category as per DIN EN 60947-5-1 AC-15: Ue 230 V, Ie 4 A (360 h -1 ) DC-13: Ue 24 V, Ie 4 A (360 h -1 ) AC-15: Ue 230 V, Ie 3 A (3600 h -1 ) DC-13: Ue 24 V, Ie 2.5 A (3600 h -1 ) Fused short-circuit current as per DIN EN 60947-5-1 1000 A Mechanical service life 10 x 10 6 cycles Signal circuits Contact allocation 1 NC, parallel, positively guided Nominal switching voltage U n AC 240 V / DC 300 V Max. continuous current I n per circuit 6 A Use category as per DIN EN 60947-5-1 AC-15: U e 230 V, I e 4 A (360 h -1 ) DC-13: U e 24 V, I e 4 A (360 h -1 ) AC-15: U e 230 V, I e 3 A (3600 h -1 ) DC-13: U e 24 V, I e 2.5 A (3600 h -1 ) Mechanical service life 10 x 10 6 cycles General data Air and creepage distances between the current circuits as per DIN EN 60664-1 Rated surge voltage 4 kv Contamination level of the unit: internal/external 2/3 Rated voltage AC 300 V Protection rating as per DIN EN 60529: housing/terminals IP 40 / IP 20 Ambient/bearing temperature -25... +55 C / -25... +75 C Weight 0.21 kg Terminal and connection data Single core or fine wire 1 x 0.14 mm² to 2.5 mm² 2 x 0.14 mm² to 0.75 mm² Stripped length max. 8 mm Fine wire with core ferule as per DIN 46228 1 x 0.25 mm² to 2.5 mm² 2 x 0.25 mm² to 0.5 mm² Maximum tightening torque 0.5 to 0.6 Nm For UL and CSA Approvals Connection cross-sections AWG 26-14 use copper conductors only; 60 C / 75 C (140 F / 167 F) Maximum tightening torque 5 7 in-lbs (0,56 0,79 Nm) Page 27