Series OLS10KD 10kW HIGH VOLTAGE POWER SUPPLY

Similar documents
HITEK POWER OLS10KD SERIES

HITEK POWER OLS10K SERIES

Series OLH10KD 10kW HIGH VOLTAGE POWER SUPPLIES

HITEK POWER OLH10K SERIES

HITEK POWER OL1K SERIES

HITEK POWER OL3000 SERIES

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

HITEK POWER OL600W SERIES

HITEK POWER XR KW X-RAY POWER SUPPLY MODULE

HITEK POWER XR KW X-RAY POWER SUPPLY MODULE

2017 Advanced Energy Industries, Inc. HITEK POWER MH60 SERIES VERSATILE HIGH-VOLTAGE POWER SUPPLY MODULES

HITEK POWER IP100 SERIES

HITEK POWER MSP SERIES MASS SPECTROMETRY POWER SUPPLY MODULES

HITEK POWER PSM10 SERIES

HITEK POWER MSRD SERIES MASS SPECTROMETRY POWER SUPPLY MODULES

HITEK POWER EG353 SERIES HIGH-STABILITY 35 KV HIGH VOLTAGE POWER SUPPLIES FOR PRECISION SEM E-BEAM APPLICATIONS

HITEK POWER MSRZ SERIES MASS SPECTROMETRY POWER SUPPLY MODULES

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD.

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

Industrial Serie +600S

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

BumbleBee. High Voltage Differential Probe Ord.-No: Features:

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

supplies and frequency converters. BumbleBee is also very effective in fast transient measurements

ECC100 Series. -40 ºC to +75 ºC Operation. 100 W - Baseplate Cooled. High Efficiency Resonant Topology. Screw Terminals Available.

NEVO+1200M. 6 x6 x W. 1.2kg DATA SHEET MAIN FEATURES

Typical Efficiency (3) 350 ma 90~305 Vac 57~103Vdc 216 W 91.0% EUC-240H035DV(SV)(5)

50W Constant Current (700mA) Dimming LED Driver

Voltage Adjustment. Load Regulation

Model 3102D 0-2 kv H.V. Power Supply

AUM FAMILY Programmable DC Power Supplies

Watts HCP Series

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.

Max. Output Power. Efficiency (1) 110Vac 220Vac

SPECIFICATION SWITCHING POWER SUPPLY SINGLE POWER 250W BEST POWER SOLUTIONS, INC. 9F, NO.196-7, SEC.3, TA-TUNG RD SHI CHIH, TAIPEI, TAIWAN, R.O.C.

ULTRAVOLT TF SERIES HIGH VOLTAGE TEST FIXTURES

SPECIFICATION SWITCHING POWER SUPPLY BPS-300SP/2U 6-OUTPUT WITH ACTIVE PFC FUNCTION SINGLE POWER 300W BEST POWER SOLUTIONS, INC.

Typical Efficiency (2)

Sorensen HPD Series 300 W 5 20 A. 300 Watt DC Power Supply with Near-Linear Performance V. with automatic crossover and mode indication

Typical Efficiency (2) 350 ma 90 ~ 305 Vac 57~114Vdc 160 W 92.0% EUC-160Q035DT(ST)(4)

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

HEC-100RTA-48QSCA Rev A1.0

Product Specification sheet

STA3318 Series StellarMini TM 180 W, Ku-Band Antenna Mount TWTA

PHV RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

Medical / Industrial AC-DC Power Supply 1200W with 5V/2A Standby / MEB-1K2A series

Output Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W

(*) Reference the User Manual or contact the factory for parallel operation between modules plugged into slots 1/2/3/4 and slots 5/6/7/8.

HEC-30/35LTA-33TDAA Rev A

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H

HEC-35LTA-XXTSAA Rev A

HEC-45LTN-45PFAS Rev A

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE BPS-460RDX 6-OUTPUT 460W+460W BEST POWER SOLUTIONS, INC.

DECLARATION OF CONFORMITY

HITEK POWER MPM SERIES MINIATURE HIGH VOLTAGE DC-TO-DC CONVERTERS

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE 370W+370W

Low Profile. 3 Year Warranty

2601 System SourceMeter 2602 Multi-Channel I-V Test Solutions

75W Constant Current (700mA) LED Driver

SM2000 TECHNICAL DESCRIPTION

DXM 300W-1200W X-RAY GENERATOR MODULE REV. AB

Agilent N8700 Series System DC Power Supplies

Electrical Specifications

Typical Efficiency (2)

General. Environmental. EMC & Safety

These medical power supplies are ideal for, monitoring, home health equipment as well as surgical devices.

HEC-150RTN-48QSCA. A. Features. B. Description. C. Models. D. Electronic Specifications - Input Specifications

SFD550-12BG Front-End Preliminary Data Sheet DC Input, 12V Output, 550 Watts

SPECIFICATION SilverStone ST30NF for Standard Switching Power Supply With Active PFC PS/2 Fanless 300W

Sirius 250/350 Watts, Single / Multi output AC-DC, modular power solution

Typical Efficiency (1) 350 ma 90 ~ 305 Vac 38~75 Vdc 26 W 86% EUC-026S035DS(PS)(4)(8)

Supplied in carry case with additional accessories The PHV 1000-RO is a 400 MHz, standard sized, 100:1 passive probe designed for instruments

Max. Output Power. Typical Efficiency (1) 12 Vdc 90 ~ 305 Vac 0~8.33 A 100 W 91% EUV-100S012ST

High precision measurement system for current and voltage IHC-A/B-RM01/03

Max. Output Power. Typical Efficiency (2) 700 ma 90~305 Vac 54~108 Vdc 75 W 90% EUC-075S070DD(SD)

300µA max at 264Vac & 63Hz (normal condition, 500µA Single Fault Condition) Adjustment Range V V. Channel

Military (Airborne, ground-fix, shipboard), Ruggedized, Telecom, Industrial

Typical Efficiency (1) 350 ma 90 ~ 305 Vac 60~120Vdc 42 W 90.0% EUC-042S035DS(PS)(4)

ULTRAVOLT HIGH-POWER C SERIES HIGH VOLTAGE CAP-CHARGING SUPPLY

Max. Output Power. Efficiency (1) 110Vac 220Vac

19998-WK 8pp 3255/3260 6/9/00 11:57 am Page B Precision Magnetics Analyzer 3255B Inductance Analyzer 3265B 25A Bias Unit

Typical Efficiency (1) 350 ma 90 ~ 305 Vac 75~149Vdc 52 W 90% EUC-052S035DV(SV)

Power Factor (2) 600 ma 90 ~ 305 Vac Vdc 34.2 W 86% 0.95 LUC-040S060RSP. Efficiency (2) Parameter Min. Typ. Max. Notes

Industrial PSU with universal input voltage range ( VAC line to line) and configurable output voltage. North America

PHV 1000-RO. High impedance passive probe. Features: CeramCore TM hybrid probe. Modular construction. Coaxial design

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

CCH400 & CCH600 Series

Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

HP005xAA025 10V to 5kV 2mA <20mV (pk-pk) <25ppm x 98 x HP030xAA V to 30kV 0.25mA <300mV (pk-pk) <20ppm x 120 x 55 1,7

HEC-40LTN-XXPSCA Rev A

Typical Efficiency (2)

1 KW TOTALLY SOLID STATE DIFFERENTIAL GPS TRANSMITTER ( khz)

Typical Efficiency (1) 350 ma 90 ~ 305 Vac 428 Vdc 150 W 93.5% EUC-150S035DT

Photovoltaic / Solar Array Simulation Solution

Transcription:

DESCRIPTION The Series OLS10KD range of high voltage power supplies recognises the requirement for high stability and very low ripple over a wide range of output voltages. This is achieved by combining the high power, 10kW supply with a low power, 1kW supply in the same chassis. The outputs of these are coupled together so that either can be used. For high voltages, usually above 10% of the maximum, the High Energy (HE) supply is used; for voltages below 10% the Low Energy (LE) supply is used. The LE supply has superior ripple and regulation at the lower voltages and maintains this down to a few hundred Volts or less. The Series OLS10KD meets the exacting requirements found in electron and ion beam systems, ion implantation and X-ray systems. There are 3 different variants available to order, the OLS10KD (208VAC), the OLS10KDC (380VAC) and the OLS10KDE (400VAC). Designed using the latest power switching IGBTs to ensure efficient and reliable operation over the full operating range, the Series OLS10KD will give exemplary performance in the most severe of electrical environments. The Series OLS10KD achieves an exceptionally high packing density for high voltage power supplies of this power level, giving 169W/Litre, 2.7W/inch 3. The 6U construction allows operation at full power when close-mounted in a standard equipment rack, giving significant savings in rack space in large systems. Many components are common between the HE and LE supplies, minimising the space required for the dual configuration. Featuring HiTek Power s unique Arc Count and Extinguish (ACE) system for managing systems where load arcing is endemic, the Series OLS10KD protects both itself and the load from damage that may be caused by excessive arcing whilst allowing normal operation to continue. FEATURES Wide Dynamic range with dual supply configuration Voltages from 10kV to 80kV for high range Voltages from 1kV to 10kV for low range High Packing Density: 10kW output power in 6U rack mounted chassis Exceptional reliability in severe electrical enviroments High Stability Arc Count and Extinguish (ACE) Full Local & Remote control and monitoring Analogue or RS232 remote control Voltage or current control RoHS compliant to EU Directive 2011/65/EU Marked for EU LV Directive 2006/95/EC The Series OLS10KD features both analogue and remote control (optional RS232) interfaces. A full set of commands is available over the RS232 interface to control and monitor the operation of the power supply. SPECIFICATION Power: 10kW for the HE supply and 1kW for the LE supply at full rated output voltage and current. Voltage: Units available with maximum HE output voltages from 10kV to 80kV, and LE output voltages from 1kV to 10kV. Current: Up to 1A for 10kV HE & 1kV LE, and 100mA for 80kV HE & 10kV LE (see table). Input Voltage: OLS10KD: OLS10KDC: OLS10KDE: Input Current: Less than 36A per phase. 208VAC ±10% (187VAC to 229VAC) 47-63Hz 3 phase 380VAC ±10% (342VAC to 418VAC) 47-63Hz 3 phase 400VAC ±10% (360VAC to 440VAC) 47-63Hz 3 phase

Polarity: Positive or negative to order. Both HE and LE will be of the same polarity. Specification Range: Specifications apply above 5% of rated output voltage for both HE and LE supplies. The output can be controlled down to less than 0.25% of rated output voltage. Installation Category: II (BS EN61010-1) Pollution Degree: 2 (BS EN61010-1) Usage: Indoor use only. Voltage Ripple: Voltage Mode: Less than 0.05% of rated voltage +2V, peak to peak or less than 0.01% of rated voltage +1V, rms. Current Mode: Less than 0.5% of rated voltage peak to peak or less than 0.1% of rated voltage rms. Voltage Regulation: Line: Less than 0.05% +0.5V change in output voltage for a 10% change in line voltage. Load: Less than 0.05% +0.5V change in output voltage for 0 to 100% change in load current. Current Regulation: Line: Less than 0.5% of rated current for a ±10% change in line voltage. Load: Less than 0.5% of rated current for 0 to 100% change in output voltage. Calibration: Calibration between Voltage Demand, Voltage and Voltage Monitor ±0.2% of setting or ±0.05% of rating, whichever is greater. Recovery Time: Less than 200ms to within 0.1% of previous operating level following a short circuit or arc. Maximum overshoot 2% of rated output voltage. Temperature Coefficient: Less than 100ppm/oC. Drift: Less than 0.01% per hour after 1 hour s warm up, typically less than 0.02% per 8 hours after 1 hour s warm up, at constant load, line and temperature. Operating Temperature: 0 C to +40 C (32 F to 140 F). Storage Temperature: -20 C to +70 C (-4 F to 158 F). Humidity: 80% maximum relative humidity up to 31 C, reducing linearly to 50% at 40 C. Non-condensing (ref BS EN61010-1). Altitude: Sea level to 2000 metres (6500 feet). Metering: Provided as part of an alpha-numeric display. Voltages are displayed with a resolution of better than 0.5% of rated output. Current is displayed with a resolution of better than 1.5% of rated output. Voltage and current set values can be displayed by pressing the relevant control potentiometer. Status Indication: Uses the alpha-numeric display to show the reason for any trip condition. Protection: The units are fully protected against over voltage, over temperature, fan failure and current limite. Peak arc current is resistively limited to 40A at full HE output voltage. Arc Count and Extinguish (ACE): Each time the ACE system detects an arc it blanks the supply off for a brief period to extinguish the arc. The unit is then allowed to recover. If more arcs occur they are counted to determine the arc rate; if this exceeds a safe level the power supply is shut down. The parameters are factory set to 25 arcs in any 5 second period. Safety: The Series OLS10KD meets the requirements of the Low Voltage Directive, LVD, 2006/95/EC by complying with BS EN61010-1:2001 when installed as a component part of other equipment. The units are CE marked accordingly. Designed to meet the general requirements of SEMI S2 for electrical safety. Safety Class: Equipment Class 1. Cooling: The unit utilises forced air cooling. Air is drawn in via the front panel louvered opening and through side panel vents. Ensure that within the rack there is a free air opening with a minimum effective area of 195cm 2 directly in front of the unit front panel louvre. An additional free air opening with a minimum effective area of 195cm 2 is required for the side vents. Air flow from this additional free air opening to the side vents of the power converter must not be restricted. The expected air flow for each opening is approximately 50 Litres per second. The maximum temperature of the air entering the unit must not exceed 40oC. The unit can dissipate up to 2kW, therefore provision must be made to extract the exhaust air from the rack in order to prevent possible overheating.

EMC: The Series OLS10KD is intended for installation as a component of a system and is designed to meet: NOTE: See Series OLS10K for a single output voltage range that can be paralleled to give 20kW. See separate datasheet. Other voltages and combinations are available to special order. EN55022 class B for conducted and radiated emissions EN61000-4-2 ESD - levels ±4kV contact, 8kV air discharge EN61000-4-4 fast transients on mains input - levels ±2kV EN61000-4-5 surges - levels ±2kV line to earth, ±1kV line to line EN61000-4-8 magnetic fields - levels 30A/m at 50/60Hz EN61000-4-11 voltage dips, interruptions The unit will not trip and recovers to normal operation after a disturbance as defined in SEMI F47-0706. The EMC performance of the power supply can only be fully assessed when installed within, and as part of, the final system. RoHS: The Series OLS10KD meets the requirements of EU Directive 2002/95/EC on the Restriction of use of Certain Hazardous Substances in electrical and electronic equipment (RoHS). Mechanical Specification: Dimensions: See outline drawings. Weight: 45kg (99 lb). Connections: All connections are mounted on the rear panel. Mains: Harting HAN C, 3m cable provided. Safety Earth: M6 stud. HV : Proprietary coaxial connector. 3m cable provided. Front panel: Stoving enamel trimite full gloss S60/9 colour blue RAL5011 as standard. Blank front panel available to order (see below). s and Ordering Information: 208VAC 380VAC 400VAC HE Voltage LE Voltage Current OLS10KD-103* OLS10KDC-103* OLS10KDE-103* 10kV 1kV 1A OLS10KD-203* OLS10KDC-203* OLS10KDE-203* 20kV 2kV 500mA Remote Control Interface Connections: The Series OLS10KD is fitted with an analogue remote control interface as standard, control is via a 25-way D-type connector. Analogue Remote Control 25-way female D-type connector: V STATUS INDICATOR I STATUS INDICATOR HV OUTPUT VOLTAGE MONITOR FAULT INDICATOR LOCAL INDICATOR HV ON INDICATOR VOLTAGE DEMAND MONITOR HV ON/OFF CONTROL Lo HV ON/OFF CONTROL Hi VOLTAGE DEMAND Hi VOLTAGE DEMAND Lo 0V MONITOR 0V All logical indicators are open collector outputs rated at 16V (max) in the off state. An internal 100Ω resistor is connected in series with the open collector transistor. The pull down voltage is 0.9V plus the internal resistor drop. All analogue Voltage and Current Monitors are 0V to +10V ±0.5% ±20mV, with respect to pin 13, representing 0 to rated output. Signal impedance is less than 100Ω and minimum external load resistance is 2kΩ. All analogue Voltage and Current Inputs are 0V to +10V on the Hi input with respect to the Lo input representing 0V to rated output ±0.2% of setting ±0.1% of rating. Input impedance is greater than 50kΩ. Digital RS232 Remote Control 9-way male D-type connector: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 HV OUTPUT CURRENT MONITOR HV OFF INDICATOR REMOTE INDICATOR ARC MONITOR INDICATOR +10V REFERENCE VOLTAGE HV ENABLE Lo HV ENABLE Hi CURRENT DEMAND Lo CURRENT DEMAND Hi OLS10KD-303* OLS10KDC-303* OLS10KDE-303* 30kV 3kV 333mA OLS10KD-403* OLS10KDC-403* OLS10KDE-403* 40kV 4kV 250mA OLS10KD-503* OLS10KDC-503* OLS10KDE-503* 50kV 5kV 200mA OLS10KD-603* OLS10KDC-603* OLS10KDE-603* 60kV 6kV 166mA OLS10KD-803* OLS10KDC-803* OLS10KDE-803* 80kV 8kV 125mA TXD TRANSMIT DATA RXD RECEIVE DATA SIGNAL GROUND 1 2 3 4 5 6 7 8 9 * Please add the required suffixed to the part number: P N B C Positive polarity Negative polarity Blank front panel (remote control only) RS232 control interface eg OLS10KD-203PBC for a 20kV positive polarity unit with no display or front panels with an RS232 interface. For voltages not listed above, please contact our sales team. The Series OLS10KD is configured as a DCE device. To connect to a PC or other DTE device, use a pin-pin DB9 female to male serial cable. The communication is set to 9,600 Baud, one start bit, one stop bit and no parity. The connector shell can be connected to earth and cable screen. A comprehensive set of commands is available for the control and monitoring of the power supply. These component power supplies meet the requirements of EC Directive 2006/95/EC (LVD).

OVER 80kV 613.5 [24.15 in] (NTS) UP TO 80kV 515.5 [20.30 in] 265.9 [10.469 in] Series OLS10KD 482.6 [19.00 in] AIRFLOW (80kV negative) (60kV negative) EARTH STUD MAINS INPUT Drawing dimensions are in mm (inches) Design developments may result in specification changes 429.8 [16.92 in] USER INTERFACE H.V. OUTPUT

UK HiTek Power Ltd Hawthorn Road, Littlehampton West Sussex BN17 7LT UK Tel: +44 (0) 1903 712400 Fax: +44 (0) 1903 712500 e-mail: hvsales@aei.com GERMANY HiTek Power GmbH Niederlassung Warstein-Belecke Emil-Siepmann-Str. 32 D-59581 Warstein-Belecke Germany Tel: +49 (0) 2902 763 521 Fax: +44 (0) 2902 763 1201 e-mail: Karsten.Schlierenkamp@aei.com Issue 8 : 4/2015