Comparison of vario. ous cables & channels

Similar documents
bedea bedea EMC of Cables & Connectors & Test methods EMC of Cables & Connectors & Test methods Test set-up CoMeT

EMC-PERFORMANCE OF BALANCED (SYMMETRICAL) CABLES

technical bulletin UTP vs STP Shielded data cables make the grade Unshielded data cables reach the limits of their performance

Measuring the EMC on RF-connectors and connecting hardware. Tube in tube test procedure

Qualification testing of 100 ohm shielded channel, Class EA. Performed for Tyco Electronics Raychem N.V.

Screening Attenuation of Long Cables

EFFECT OF SHIELDING ON CABLE RF INGRESS MEASUREMENTS LARRY COHEN

This specification describes termination procedures of AMP Netconnect Cat.6 Compact Patch Panel 0.5U:

EMC of Connectors & Assemblies. Bernhard Mund, bedea Berkenhoff & Drebes GmbH, Herbornerstrasse 100, D Asslar,

Independent 3rd Party Test Study for 10GBE. New insights for end users and consultants

Independent Testing - For End User Confidence

Install & Go SMARTen (Cat.6A) STP Trunk Cable Assembly General

Install & Go Cat.8 STP Trunk Cable Assembly Description

Install & Go Cat.8 S/FTP Trunk Cable Assembly Description

Category 6 A F/FTP Euroclass C ca Cables

125 Eugene O Neill Drive 6120 Powers Ferry Road New London, CT Suite 150 Ph (860) Atlanta, GA Fax (860)

Coupling attenuation and EMC considerations Draft 1.2 Comments #363 and #364

125 Eugene O Neill Drive 6120 Powers Ferry Road New London, CT Suite 150 Ph (860) Atlanta, GA Fax (860)

Higher order mode suppression in Triaxial cells. Overview. Higher order Mode Suppression in Triaxial Cells (Improvement of Triaxial Cell procedure)

Test Report based on DIN EN ISO/IEC 17025

NETWORK CONNECTIVITY SYSTEMS

INTERNATIONAL STANDARD

10GBASE-T. Channel Model Proposal

Field Testing Update

Category 7 A /Class F A Products

MEASUREMENTS OF COUPLING THROUGH BRAIDED SHIELD VIA NEW CONDUCTED IMMUNITY TECH- NIQUE

bedea Mess-System CoMeT Measuring of EMC Characteristics on Cables for Information & Communication Technics 1-1

Test Report based on DIN EN ISO/IEC 17025: 2005

Test report number CRT-001b Project number CRT-001b

IEEE RTPGE Automotive Datalinks over Twisted Quad Cabling

COPPER + LWL RAW CABLES

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

Test Report based on DIN EN ISO/IEC 17025:2005

Physical Test Setup for Impulse Noise Testing

Requirements for Industrial Cabling Supporting Gigabit Applications for Control, A study of Noise

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

UC DATA CABLES - CAT 5,6, 7 & 8

INTERNATIONAL STANDARD

TEST REPORT. DANAK Reg. no. 19. Electrical performance testing of: Connecting Hardware according to IEC

Superiorr Essex. Suite 150

- Characteristic impedance of cabling links is characterised by Return Loss

Bulk Current Injection instead of Radiated immunity testing, in the range from 1 MHz upto 1 GHz: Measuring results

INTERNATIONAL STANDARD

Coupling- / Decoupling Network. 150 khz 300 MHz. 150 khz 230 MHz. 10 khz 230 MHz. IEC and CISPR 15 / CISPR 22 IEC

10 Mb/s Single Twisted Pair Ethernet Conducted Immunity Steffen Graber Pepperl+Fuchs

XX.7 Link segment characteristics

This is a preview - click here to buy the full publication

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft

Information technology. Generic cabling systems, General requirements

Influence of Aging Effects on Cables. Influence of Aging Effects on RF behavior Including Mode Conversion of STP and UTP Cables

SERIES K: PROTECTION AGAINST INTERFERENCE

This document is a preview generated by EVS

Composite Data, Audio, Video, Security and Control Cables Banana Peel Jacketless Cables Category 5e

a fast, reliable and ubiquitous part of the Draka Office Network Solution

Data sheet Patch cord Cat.6 A AWG m yellow

AMP NETCONNECT Category 6 System

Data sheet C6 A modul K 180 jack - Keystone style

Category 6 UTP EuroClass C ca Cables

INTERNATIONAL STANDARD

CABLE.

Some considerations concerning alien crosstalk Dr.-Ing. J.-H. (Jo) Walling Consultant Beaconsfield, P.Q. Canada

Chapter 12: Transmission Lines. EET-223: RF Communication Circuits Walter Lara

TECHNICAL SPECIFICATION

CHAMBER EXIT FILTERS FOR EMC TESTING

ISO/IEC JTC 1/SC 25/WG 3 N 755 Date: Replaces ISO/IEC JTC 1/SC 25/WG 3 N n/a

This document is a preview generated by EVS

Data sheet C6 A modul K 90 jack - keystone style

UC Data Cable a fast, reliable and ubiquitous part of the Draka Office Network Solution

William Stallings Data and Computer Communications. Bab 4 Media Transmisi

Data sheet C6 A RJ45 field plug pro 360

Data sheet. E-DAT modul Cat.6A 8(8) jack, T568B. Illustrations P/N I-B1 EAN Product specification. Page 1/

Nexans Industrial Solutions PRODUCT CATALOG

Data sheet C6 A RJ45 field plug pro

Methods for Testing Impulse Noise Tolerance

Use and abuse of screened cables

INSTRUCTIONS MODEL AVC MONOCYCLE GENERATOR MODULE SERIAL NUMBER:

Marshall Tufflex. Cable Management. Data Compliant Trunking Systems

YRS01 York Reference Source

ACR (Attenuation to Crosstalk Ratio) ACR-F. Alien Crosstalk. Attenuation (signal attenuation, conductor attenuation)

AESA TECHNOLOGY OF LAN CABLE

This is a preview - click here to buy the full publication INTERNATIONAL ELECTROTECHNICAL COMMISSION

PHY PMA electrical specs baseline proposal for 803.an

Link budget for 40GBASE-CR4 and 100GBASE-CR10

INTERNATIONAL STANDARD

R&S RSC Step Attenuator Specifications

A GTEM BEST PRACTICE GUIDE APPLYING IEC TO THE USE OF GTEM CELLS

Semi Anechoic Chamber (SAC)

Vector Network Analyzers ZVB

n Proper pin termination at each end n Continuity to the remote end n Shorts between any two or more conductors n Transposed pairs: n Crossed pairs.

Special testing of 100 ohm unshielded channel, Class E. Performed for HCS KABLOLAMA SISTEMLERI SAN.VE TIS.A.S.

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

Actual Cable Data update

ORBIS RELIABLE CONFERENCING

EMC aspects associated to 5G networks

10 Mb/s Single Twisted Pair Ethernet Evaluation Board Noise Measurements Marcel Medina Steffen Graber Pepperl+Fuchs

Alternative Coupling Method for Immunity Testing of Power Grid Protection Equipment

Data sheet. C5 RJ45 field plug pro 2P 360 PROFINET. Illustrations P/N 130E405042PE EAN Product specification. Page 1/

DELTA Test Report. Certification testing of generic cabling products: Unscreened channel, Class E, 4 connector model. Performed for Sterling

EMC Test Report. Report Number: M030826

Coupling/Decoupling Networks (CDN)

Transcription:

Noise Immunity Performance Analysis of Screened Cab bling Systems Comparison of vario ous cables & channels Martin Rossbach, Nexans Cabling Solutions Victoria, BC, Canada May 16, 2013

Overview Definition Current Specifications in ISO/IEC an nd TIA Test Data Cables Test Data Channels Conclusions and Recommendations May 2013 2

Definition of Coupling attenuation What is Coupling Attenuation? Coupling Attenuation is a measure of both emission and immunity of twisted pair cabling. It is defined as the ratio of the power transmitted into the pair to the power coupled into its environment. For balanced cables it combines unbalance attenuation (a u ) and screening attenuation (a s ) a c = a u + a s May 2013 3

IEC Standards for Coupling Attenuation Full Set of Test Standards is developed 2 Methods comparable results (~3 db deviation 1 ) IEC 62153-4-5: Metallic communication cable test methods Part 4-5: Electromagnetic Compatibility (EMC) Coupling or screening attenuation Absorbing clamp method Absorbing Clamp Triaxial Frequency Range covered : 1 1GHz Note 1: O. Breitenbach, T. Hähner, B. Mund, "Screening of cables in the MHz to GHz frequency range extend ed application of a simple measuring method", Colloquium on screening effectiveness measurements, Savoy Place London, 6 May 1998, Reference No:1998/452; T. Hähner, B. Mund, Background, content and future of the EMC measurement standard pren 50289-1-6, T. Hähner, B. Mund, EMC Symposium Wroclow 2000, TEST METHODS FOR SCREENING AND BALANCE OF COMMUNICATION CABLES, EMC Symposium Zürich, 1999 May 2013 4

Current Specifications: Cable ISO/IEC Cable standard (IEC61156-5) know 3 different cable grades in terms of Noise Immunity Like U/UTP : No Shield Like F/UTP : One Shield Like S/FTP: Double Shield May 2013 5

Current Specifications: Channel ISO/IEC 11801 has one requirement for all cabling channels and does not make a difference between various cabling types Some difference in Noise immunity is recognised in combination with Alien Crosstalk testing : +10dB an + 25 db leads to Met by design rule TIA recently added Coupling attenuation and now defines a requirement for Cat. 8 ISO 40GReport uses also +10dB line May 2013 6

CA and PSANEXT Met by Design Rules of ISO11801 imply pythat Alien Crosstalk assumed to be at least 15dB better then Coupling attenuation May 2013 7

TEST DATA CABL LE May 2013 8

Test Description All measurements done during 2009 and 2010 Testmethod: EN50289-1-6 Frequency Range : 30-1000MHz 7 cable types tested Name CAT6 F/UTP Cat6A F/UTP Cat6A U/FTP Cat6A F/XT TP Cat6A F/FTP Cat7A S/FTP low Cat7A S/FTP High Outer Shield Foil Foil No Foil Foil Loose Braid Tight Braid Pair Shield No No Foil Half Alu Cross Foil Foil Foil May 2013 9

Worst Case: Cat6A UFTP Cable May 2013 10

Best Case: Cat7A Cable 1200MHz SFTP Cat7A 1200MHz May 2013 11

Comparison of Cabling Types Observations 1 Shield = Enables Grade 2 1 Shield and Good Balance enables almost Grade 1 (not at extremes of freq range) 2 Good Shields = Enable Grade 1 Current Spec of ISO/TIA not very ambitious May 2013 12

Comparison of Screened Cable Types Same test results but presented in form of limit lines / envelopes Significant Improvement compared to Grade 2 / Cat.8 spec is possible Single Shield Double Shield May 2013 13

TEST DATA CHANNEL Historic Data made in 20 09 Frequency Range 30-1000 MHz 3Types of Cables : F/UTP; F/FTP; S/FTP 2 Types of Connectors IEC60603-7-51 (RJ45); IEC60603-7-71 (GG45) May 2013 14

Coupling Attenuation Cat6A Connectivity with F/UTP Cable Cat6A Connectivity with F/FTP Cable May 2013 15

Coupling Attenuation of Cat7A Channel May 2013 16

Comparison of Channel Types New limits challenging for U/UTP Influence of Connectors clearly visible Channels ~ 15-20dB below cable RJ45 GG45 IEC60603-7-71 Connector shows room for tighter specification May 2013 17

Data from March 2013 up to 2GHz Measurement data provided by indepen- dant testlab GMHT using S/FTP cable 2 Connector Channel 45M May 2013 18

Current Specifications re-visited Alien Crosstalk Spec was increased in TIA Draft Cat.8 and ISO Channel I and diit to match hbackground noise Coupling attenuation has been increased, but not yet to this extent Met by Design Rule of ~ 15dB indicates another 10dB increase could be needed But any increase should follow not considerations for Field testing of cabling systems but the demand of the application May 2013 19

Conclusion Second Shield seems to be more effective than Balance for Noise Immunity First test indicates that frequency extension for Double Foil products is possible Historic Data for Coupling attenuation of screened cables and channels indicate that current CA specfications can be tightened, if needed for 40GBase-T Next Steps: Task Group shall give guidance to cabling commitees which level of Coupling attenuation is appropiate for 40GBase-T (how much increase?) Measure Single Shielded cable and channels above 1 GHz Explore poeways to improve po eca of Connectors/Assemblies sse es May 2013 20