Current transformers TI current transformers 0

Similar documents
Data Sheet. Summation Current Transformer OMEGA SUMMATION CT : SIGMA SERIES. Page 1 of 5 00 / 1213

MULTIBLOC 4a.ST8 Size 4a, 690VAC, 1600A, 690VAC, Design for Bottom Fitting, 1-, 3-pole

Single phase meter with direct connection and pulse or Modbus RS485 output

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Protection components

Current / residual current and voltage transformers. Current / residual current and voltage transformers

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Modular equipment. Presentation, standards. Standard contactors TeSys GC

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

W DATA SHEET Current Transformer 40 x 10, A

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

isw switches Control Local control IEC/EN , isw switch with indicator light. IEC/EN , isw switch without indicator light.

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Protection relays and transformers

Inductive Proximity Sensor

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

Data Sheet. Summation Current Transformer. RISH SUMMATION CT : RISH XMER Sigma. RISH XMER Sigma. Page 1 of 5 00 / 1213

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

NS..S contactor relays - with spring terminals AC operated

P2 H2 NAMEPLATE 6 HOLES M8-10 M SCREW S1 1S2 1S3 X1 X2 X3 PARALLEL HIGH RATIO

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

3-phase meter with direct connection and pulse or Modbus RS485 output

TL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Differential pressure sensors

ZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Solid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval

Three-phase monitoring relays

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Relays and associated toroids

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

Three-phase monitoring relay CM-PFS

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

MULTIBLOC 00.ST8 Size A, 690VAC Bottom Fitting, 1-,2-,4-pole

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67g environment resistance

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

Three-phase monitoring relay

Analogue temperature controllers

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

MOVING-IRON METERS EA16, EB16, EA17, EA19, EA12 TYPES

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Control module CP-A CM

DIN Rail Kilowatt Hour Energy Meters

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Electronic Installation Buzzer

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Section five. Connection systems. Isobar 4 Evo MCB pan assemblies Mulitclip busbar and Polybloc 126. Comb busbars 127

Electronic timer CT-SDS.22

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

Electronic Thermostat TE-1 Version according to EN

Electronic Step Controller

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

05/09/2012

DATA SHEET Selectable AC transducer TAS-311DG

EARTH LEAKAGE RELAY RELAY FOR PERMANENT CONTROL OF THE MCCB S TRIPPING CIRCUIT AND ACTUATOR FOR SAFETY CIRCUITS

Assembly. Front view. DIP switch. LED yellow: Relay output 1. LED yellow: Relay output Power Rail

EA16, EB16, EA17, EA19, EA12 MOVING-IRON METERS Ammeters and Voltmeters

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Transformers, Power Supply Units and Socket Outlets

DRIVIA cabinets LIMOGES Cedex France 1. DESCRIPTION, USE 3. DIMENSIONS 2. RANGE, CAT. NO. EQUIVALENCE TABLE

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

itl impulse relays IEC/EN itls: IEC/EN itls b Allows remote indication of its operating state (open/closed)

Series P. Applications

27/04/2015

EA16, EB16, EA17, EA19

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC

Liquid level monitoring relay CM-ENS.2x

Monitoring Relays 3-Phase Active power Types DWB02, PWB02

MINI MCR-SL-UI-I-LP-NC

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

Powered by technology...driven by service CURRENT TRANSFORMERS. Multifunction Meters. Transducers & Isolators. Temperature Controllers

Advantages. Applications

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

ANALOG PANEL METERS. Moving-iron meters EB16 EA16 EA17 EA19 EA12. Moving-coil meters with rectifiers MA17P MA19P MA12P. 3-phase voltmeters

TECHNICAL MANUAL FOR LOOP DETECTORS WITH POWERFAIL MEMORY Article Codes: RDET1CM & RDET2CM

CMM System - Encapsulated Modules

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

I PM. Current Transducer ITZ 5000-SB FLEX ULTRASTAB = 5000 A

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

LED Driver Compact fixed output 4,5 83,5 93. Ordering data. Type

Characteristics 5 TeSys k contactors and reversing contactors

Transcription:

Current transformers TI current transformers 0 056853NMD-2 056854NMD-2 16503. Function Current transformers with a ratio of Ip/5, for measurement devices (ammeters, kilowatt hour meters), load shedders, control relays, etc. Common technical data b Secondary current: 5 A. b Max. voltage rating Ue: 720 V. b Frequency: 50 60 Hz. b Safety factor: v 40 to 4000 A: fs y 5 v 5000 to 6000 A: fs y 10. b IP20. b Ambient installation temperature: v standard range: - 5 C to + 55 C, humidity < 95 % v tropicalised range: - 25 C to + 60 C, humidity > 95 %. b Reference standards: IEC 44-1, NFC42502, VDE 0414, BS 7626 and IEC 38-1. b Weight: 056852NMD-2 16512. Weight (g) 16500 16506 and 16451 16456 200 16509 16515 and 16459 16465 270 16518 16521 and 16468 16471 430 16523 16524 and 16473 16474 500 16526 16535 and 16476 16483 600 16537 16538 700 16540 16544 1500 16545 16547 1500 16548 16549 5000 Specific technical data PB100316 16542. 16503 + 16550. TI with let-through primary: b Secondary connection using terminals for lug, using tunnel terminals or using screws (depending on cat. no.). b Delivered with: fixing on a symmetrical rail fixing on a plate Insulated binding screw Sealable cover 16500...16506 and b b b 16451...16456 16509...16512 and b b b Optional 16459...16462 16518...16521 and b b b Optional 16468...16471 16523...16524 and b b b 16473...16474 16526...16535 and b b 16476...16483 16537...16538 b b 16540...16544 b b 16545...16547 b b 16548...16549 b b 056855MD-2 Sealable cover. b Maximum dimensions for primary circuit cable inlets: Opening Cable Ø 16500 16506 and 16451 16456 20 x 5 mm 21 16509 16512 and 16459 16462 30 x 10 mm 22 16518 16521 and 16468 16471 40 x 10 mm 35 16523 16524 and 16473 16474 64 x 11 mm and 51 x 31 mm 16526 16535 and 16476 16483 65 x 32 mm 32 16537 16538 34 x 84 mm 16540 16544 38 x 127 mm 16545 16547 52 x 127 mm 16548 16549 55 x 165 mm

Current transformers TI current transformers (cont.) 0 TI with connection of primary by screw and nut: b Secondary connection using terminals for lug or tunnel terminals (depending on cat. no.). b Cylinder Ø 8.5 mm. b Cylinder Ø 12.5 mm. b Delivered with: (1) Rigid flat. (2) Rigid vertical. (3) < 80 mm rigid. (4) 80 mm rigid. (5) 100 mm rigid. (6) 100 mm rigid triple. fixing on a symmetrical rail fixing on a plate Sealable cover 16500 16506 and 16451 16456 b b b 16511 16515 and 16461 16465 b b Optional TI with let-through primary Ratio Insulated Prisma cable vertical Insulated flexible Linergy vertical Rigid Cat. no. TI standard Cat. no. TI tropical 40/5 b 16500 50/5 b 16501 16451 75/5 b 16502 16452 100/5 b 16503 16453 125/5 b b 16504 16454 150/5 b b b 16505 16455 b 16509 16459 200/5 b b b 16506 16456 b 16510 16460 b 16526 16476 250/5 b b b 16511 16461 b 16518 16468 b 16527 16477 300/5 b 16512 16462 b b b 16519 16469 b 16528 16478 400/5 b b b b 16520 16470 b 16529 16479 500/5 b b 16521 16471 b 16523 16473 b 16530 16480 600/5 b b (1) 16524 16474 b b b (2) 16531 16481 800/5 b b b 16532 16482 1000/5 b b b 16533 16483 1250/5 b b b (3) 16534 b (4) 16537 b (5) 16540 1500/5 b (3) 16535 b (4) 16538 b (5) 16541 2000/5 b 16542 2500/5 b 16543 b (6) 16545 3000/5 b 16544 b (6) 16546 4000/5 b 16547 5000/5 b 16548 6000/5 b 16549

Current transformers TI current transformers (cont.) 0 TI with connection of primary by screw and nut Ratio Cat. no. TI standard Cat. no. TI tropical Cat. no. cylinder 40/5 16500 + 16550 50/5 16501 or 16451 + 16550 75/5 16502 or 16452 + 16550 100/5 16503 or 16453 + 16550 125/5 16504 or 16454 + 16550 150/5 16505 or 16455 + 16550 200/5 16506 or 16456 + 16550 250/5 16511 or 16461 + 16551 300/5 16512 or 16462 + 16551 400/5 16513 or 16463 + 16551 500/5 16514 or 16464 + 16551 600/5 16515 or 16465 + 16551 Accessories Type Cat. no. Cylinder Ø 8.5 mm 16550 Ø 12.5 mm 16551 Sealable cover for cat. nos. 16509 to 16515 and 16459 to 16465 16552 for cat. nos. 16518 to 16521 and 16468 to 16471 16553 Connection E56648 S1 S2 K L P1 K E56651 K P2 TI with let-through primary. E56646 E56647 S1 S2 K L P1 K S1 S2 K L P1 K TI with connection of primary by screw and nut.

Current transformers TI current transformers 0 Choice and accuracy class Choosing a current transformer 2 criteria exist for choosing a TI: b the Ip/5 A ratio b the type of installation. The Ip/5 A ratio It is recommended that a ratio immediately above the measured current (In) be chosen. Example: In = 1103 A; ratio chosen: 1250/5. Type of installation Which TI model to choose depends on the type of installation: b insulated cables b Prisma vertical b insulated flexible b Linergy vertical b rigid. Important warning Never open the secondary circuit of a current transformer while the primary circuit is energized. Before any kind of maintenance service on the secondary circuit, the secondary terminals on the tranformer must be short-circuited. Determining the accuracy class of a TI The accuracy class is a function of the transformer's power and the consumption of the measurement system. The latter takes device and cable consumption into account. For a given accuracy class, consumption of the measurement system must not exceed the power on the TI transformer. Copper cable cross-section in mm 2 Power in VA per doubled meter at 20 C 1 1 1.5 0.685 2.5 0.41 4 0.254 6 0.169 10 0.0975 For each temperation variation of 10 C, the power absorbed by the cables rises by 4 %. Merlin Gerin device Consumption in VA Ammeter 72 x 72 / 96 x 96 1.1 Analog ammeter 1.1 Ammeter Digipact IM100 0.5 Digital ammeter 0.3 PM500, PM700, PM800, CM3000, CM4000 0.15 CE tri 1.2 CEr tri 1.2 ME4zrt 0.05 PM9 0.55

Current transformers TI current transformers 0 Choice and accuracy class (cont.) Example: consumption of a measurement system at 20 C PM9 0.55 VA Digital ammeter + 0.30 VA 4 meters of doubled wire 2.5 mm 2 + 1.64 VA Measurement system consumption = 2.19 VA The accuracy class of the TI is deduced: b class 3 for a TI with a ratio of 75/5 b class 1 for a TI with a ratio of 100/5 b class 0.5 for a TI with a ratio of 125/5. Ip/5 Cat. no. Power (VA) accuracy class standard TI tropical TI 0.5 1 3 40 A 16500 16500 1 50 A 16501 16451 1.25 1.5 75 A 16502 16452 1.5 2.5 100 A 16503 16453 2 2.5 3.5 125 A 16504 16454 2.5 3.5 4 150 A 16505 16455 3 4 5 16509 16459 1.5 5.5 6.5 200 A 16506 16456 4 5.5 6 16510 16460 4 7 8.5 16526 16476 2 5 250 A 16511 16461 6 9 11 16518 16468 2.5 5 8 16527 16477 1 4 6 300 A 16512 16462 7.5 11 13.5 16519 16469 4 8 12 16528 16478 1.5 6 7 400 A 16513 16463 10.5 15 18 16520 16470 8 12 15 16529 16479 4 8 10 500 A 16514 16464 12 18 22 16521 16471 10 12 15 16523 16473 2 4 6 16530 16480 8 10 12 600 A 16515 16465 14.5 21.5 26 16524 16474 4 6 8 16531 16481 8 12 15 800 A 16532 16482 12 15 20 1000 A 16533 16483 15 20 25 1250 A 16534 16534 15 20 25 16537 16537 12 15 20 16540 16540 8 12 1500 A 16535 16535 20 25 30 16538 16538 15 20 25 16541 16541 10 15 2000 A 16542 16542 15 20 2500 A 16543 16543 20 25 16545 16545 30 50 60 3000 A 16544 16544 25 30 16546 16546 40 60 60 4000 A 16547 16547 50 60 60 5000 A 16548 16548 60 120 6000 A 16549 16549 70 120

Current transformers Dimensions 0 TI current transformers E58377 E58380 E58383 Cat. no. 16500 to 16506, 16451 to 16456 Cat. no. 16509 to 16515, 16459 to 16465 Cat. no. 16518 to 16521, 16468 to 16471 E58376 E58379 E58382 Cat. no. 16523 and 16524, 16473 and 16474 Cat. no. 16526 to 16535, 16476 to 16483 Cat. no. 16537 and 16538 E58375 E58378 E58381 Cat. no. 16540 to 16544 Cat. no. 16545 to 16547 Cat. no. 16548 and 16549 Cylinders E90390 E90391 Cat. no. 16550 Cat. no. 16551