A Noise-Temperature Measurement System Using a Cryogenic Attenuator

Similar documents
A Low Noise GHz Amplifier

A Method for Gain over Temperature Measurements Using Two Hot Noise Sources

AVN Training HartRAO 2016

Preliminary Users Manual for the Self Contained Return Loss and Cable Fault Test Set with Amplified Wideband Noise Source Copyright 2001 Bryan K.

RF Characterization Report

There is a twenty db improvement in the reflection measurements when the port match errors are removed.

Agilent AN Applying Error Correction to Network Analyzer Measurements

NATIONAL RADIO ASTRONOMY OBSERVATORY CHARLOTTESVILLE, VIRGINIA. ELECTRONICS DIVISION INTERNAL REPORT No. 275 CRYOGENIC, HEMT, LOW-NOISE RECEIVERS

Coaxial TRL Calibration Kits for Network Analyzers up to 40 GHz

On-Wafer Noise Parameter Measurements using Cold-Noise Source and Automatic Receiver Calibration

SWR/Return Loss Measurements Using System IIA

Cryogenic Systems and Receiver Maintenance

Circuit Characterization with the Agilent 8714 VNA

AGRON / E E / MTEOR 518 Laboratory

Comparison of Noise Temperature Measurements with Vector Network Analyzer (PNA-X) and Noise Figure Meter (NFA)

Micro-manipulated Cryogenic & Vacuum Probe Systems

Ku-Band Receiver System for SHAO

. /, , #,! 45 (6 554) &&7

VSWR MEASUREMENT APPLICATION NOTE ANV004.

Influence of Temperature Variations on the Stability of a Submm Wave Receiver

Noise by the Numbers

A Reduced Uncertainty Method for Gain over Temperature Measurements in an Anechoic Chamber

MASSACHUSETTS INSTITUTE OF TECHNOLOGY HAYSTACK OBSERVATORY

Design and Demonstration of a Passive, Broadband Equalizer for an SLED Chris Brinton, Matthew Wharton, and Allen Katz

VGOS MEMO #042 MASSACHUSETTS INSTITUTE OF TECHNOLOGY HAYSTACK OBSERVATORY WESTFORD, MASSACHUSETTS August 22, 2016

PA FAN PLATE ASSEMBLY 188D6127G1 SYMBOL PART NO. DESCRIPTION. 4 SBS /10 Spring nut. 5 19A702339P510 Screw, thread forming, flat head.

MASSACHUSETTS INSTITUTE OF TECHNOLOGY HAYSTACK OBSERVATORY WESTFORD, MASSACHUSETTS

MWA REVB LNA Measurements

Technical Note. HVM Receiver Noise Figure Measurements

LOW NOISE GHZ RECEIVERS USING SINGLE-DIODE HARMONIC MIXERS

CHAPTER - 3 PIN DIODE RF ATTENUATORS

Waveguide Calibration with Copper Mountain Technologies VNA

Low Noise Amplifiers with High Dynamic Range

RF power measurement in. three-mixer method

Keysight Technologies Pulsed Antenna Measurements Using PNA Network Analyzers

Swept Return Loss & VSWR Antenna Measurements using the Eagle Technologies RF Bridge

EE 3324 Electromagnetics Laboratory

Application Note: Swept Return Loss & VSWR Antenna Measurements using the Eagle Technologies RF Bridge

MICROWAVE MICROWAVE TRAINING BENCH COMPONENT SPECIFICATIONS:

Preamplifier Options for Reducing Cable-Braid Loop Error

Keysight Technologies Connector Pin Recession and its Effect on Network Analyzer Accuracy

NATIONAL UNIVERSITY of SINGAPORE

Determination of Uncertainty for Dielectric Properties Determination of Printed Circuit Board Material

Vector-Receiver Load Pull Measurement

A Low-Loss VHF/UHF Diplexer

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD

LOCALIZED LNA COOLING IN VACUUM

Noise generators. Spatial Combining of Multiple Microwave Noise Radiators NOISE ARRAY. This article reports on. experiments to increase the

Challenges and Solutions for Removing Fixture Effects in Multi-port Measurements

New Ultra-Fast Noise Parameter System... Opening A New Realm of Possibilities in Noise Characterization

Noise Calibration Systems and Accessories DATA SHEET / 4N-062

Noise Figure Definitions and Measurements What is this all about?...

Chapter 5. Array of Star Spirals

Common Types of Noise

ELEC4604. RF Electronics. Experiment 2

Noise Figure Measurement Accuracy The Y-Factor Method. Application Note 57-2

SMT Hybrid Couplers, RF Parameters and Applications

A New Noise Parameter Measurement Method Results in More than 100x Speed Improvement and Enhanced Measurement Accuracy

Shielding. Fig. 6.1: Using a Steel Paint Can

R&D White Paper WHP 066. Specifying UHF active antennas and calculating system performance. Research & Development BRITISH BROADCASTING CORPORATION

Bill Ham Martin Ogbuokiri. This clause specifies the electrical performance requirements for shielded and unshielded cables.

Keysight Technologies Vector Network Analyzer Receiver Dynamic Accuracy

FieldFox Handheld Education Series Part 3: Calibration Techniques for Precise Field Measurements

D-band Vector Network Analyzer*

772D coaxial dual-directional coupler 773D coaxial directional coupler. 775D coaxial dual-directional coupler 776D coaxial dual-directional coupler

Application Note 5525

Receiver Design for Passive Millimeter Wave (PMMW) Imaging

NATIONAL RADIO ASTRONOMY OBSERVATORY CHARLOTTESVILLE, VIRGINIA. ELECTRONICS DIVISION INTERNAL REPORT No. 262

Welcome to the Hirose MS-162A product training module. This tutorial will introduce the MS-162A series and explain its features and benefits.

NUMBER OF COPIES: 75

Hot S 22 and Hot K-factor Measurements

LOCALIZED LNA COOLING IN VACUUM

Evaluating VNA post-calibration residual errors using the ripple technique at millimetre wavelengths in rectangular waveguide

RF and Microwave Design Solutions. Bob Alman (707)

DESIGN AND CONSTRUCTION OF THE COSMIC MICROWAVE RADIOMETER

Design of a Sideband-Separating Balanced SIS Mixer Based on Waveguide Hybrids

K band Focal Plane Array: Mechanical and Cryogenic Considerations Steve White,Bob Simon, Mike Stennes February 20, 2008 COLD ELECTRONICS

BROADBAND GAIN STANDARDS FOR WIRELESS MEASUREMENTS

ALMA Band-1: Key Components, Cartridge Design, and Test Plan

Offset Waveguide Transmission Measurements

On Wafer Load Pull and Noise Measurements using Computer Controlled Microwave Tuners

Applications and Advantages of USB RF Power Sensors Richard R Hawkins, President LadyBug Technologies LLC

Impedance 50 (75 connectors via adapters)

UNDERSTANDING NOISE PARAMETER MEASUREMENTS (AN )

Holography Transmitter Design Bill Shillue 2000-Oct-03

Termination Insensitive Mixers By Howard Hausman President/CEO, MITEQ, Inc. 100 Davids Drive Hauppauge, NY

Agilent Accurate Measurement of Packaged RF Devices. White Paper

EC 1402 Microwave Engineering

ECEN 5014, Spring 2009 Special Topics: Active Microwave Circuits Zoya Popovic, University of Colorado, Boulder

RESISTIVE POWER SPLITTERS AND DIVIDERS

5G and mmwave Testing

Design, Development and Testing of RF Window for C band 250 kw CW Power Klystron

TECHNICAL INFORMATION

Keysight Technologies Making Accurate Intermodulation Distortion Measurements with the PNA-X Network Analyzer, 10 MHz to 26.5 GHz

ALMA Memo 436. Band 6 Receiver Noise Measurements using a Pre- Prototype YIG-Tunable LO

TYPE 874-GAL ADJUSTABLE ATTENUATOR

DARE!! Instruments Application Note GHz Radiated RF Immunity Testing

DESIGN AND CHARACTERISATION OF A LOW NOISE ACTIVE ANTENNA (LNAA) FOR SKA

Aperture Antennas. Reflectors, horns. High Gain Nearly real input impedance. Huygens Principle

Chapter 41 Deep Space Station 13: Venus

Transcription:

TMO Progress Report 42-135 November 15, 1998 A Noise-Temperature Measurement System Using a Cryogenic Attenuator J. E. Fernandez 1 This article describes a method to obtain accurate and repeatable input noisetemperature measurements of cryogenically cooled low-noise amplifiers using a commercial noise-figure meter in conjunction with a cryogenic attenuator co-located with the amplifier under test. The calibration techniques used also are discussed. I. Introduction Accurate and rapid noise-temperature measurements are critical to the modeling and development of high electron mobility transistor (HEMT) cryogenically cooled amplifiers. Four different techniques have been used in the laboratory to make noise-temperature measurements of cryogenically cooled amplifiers, and each of these is described below. Following this, the cryogenic pad method, the method most often used by the Cryogenics Electronics Front-End Equipment Group at JPL, is described. Although the cryogenic pad and noise-figure meter are not in and of themselves new, combining them provides an elegant, simple, and quick solution to equivalent input noise-temperature and gain measurements. A basic piece of equipment needed for cryogenic noise measurements is a cryogenic test-bed capable of cooling the amplifier under test to its operational temperature (typically or less). The testbed, shown schematically in Fig. 1, consists of a vacuum housing, a two-stage Gifford McMahon helium refrigerator, and very low loss input and output RF transmission lines. These lines are copper-plated thin-wall stainless steel to provide low insertion loss and low thermal leakage from the outside room temperature to the internal 15-K environment. II. Measurement Methods The following methods for obtaining noise temperature data all employ similar measurement techniques. All of the methods described below use the Y-factor method for obtaining noise temperature data. This method involves taking the ratio of output noise powers when two different input thermal noise powers are presented to the amplifier. The two different noise powers presented to the input of the amplifier can involve the use of a load whose temperature can be varied or two different loads whose respective temperatures are significantly different. This change in load temperature gives a corresponding change in noise power measured at the output of the low-noise amplifier (LNA). The methods differ in their techniques for producing the two different input noise powers, usually designated T h and T c. 1 Communications Ground Systems Section. 1

INPUT COPPER-PLATED STAINLESS-STEEL STAINLESS-STEEL INPUT LINE Fig. 1. The cryogenic test-bed with coaxial air line input and output. The effective input noise temperature of a device under test (), T e, is determined by the following equation: T e = T h Y T c Y 1 (1) where T h and T c are the noise temperatures of the hot and cold noise sources and Y is the ratio of the output powers obtained from the when each of the source temperatures is applied. A. Method I: Standard Hot and Cold Loads This straightforward method involves switching the input between two separate terminations that are at widely different, known physical temperatures. This method, shown in Fig. 2, has a large number of difficulties associated with achieving accurate noise measurement. One reason is that the impedances presented to the by the hot and cold paths usually differ significantly from each other. Also, the long-term repeatability of insertion loss and impedance match of the noise source switch is crucial to accurate results. The commonly limited bandwidths of practical cold loads require custom equipment. Still another difficulty is the slow speed of obtaining data due to the mechanical switch. This last limitation is a serious liability when many repetitive measurements need to be made, as when transistor bias settings are being adjusted for optimum performance on a multiple-stage amplifier. This method is still accurate and often is used when many repetitive measurements are not necessary. B. Method II: Noise-Figure Meter With Noise Diode The simplest method for making noise-temperature measurements of active devices, such as amplifiers, is to use a commercial noise-figure meter in conjunction with a calibrated diode noise source. A block diagram of this method is shown in Fig. 3. This is the standard method used to measure room-temperature transistor amplifiers, and it works very well with s that have an input noise temperature between the off (cold) and on (hot) noise temperatures presented by the diode noise source that is, between 300 kelvins and thousands of kelvins. However, as the equivalent input noise temperatures of microwave HEMT amplifiers have dropped to temperatures below 50 K for room-temperature amplifiers, and lower still for cryogenic amplifiers, the errors provided by this approach are excessive. Another significant shortcoming with this approach is that the diode noise-source impedances in the off and on states are significantly different from each other. This causes a wide variation in the values of input noise temperatures 2

INPUT COPPER-PLATED STAINLESS-STEEL STAINLESS-STEEL HOT LOAD SWITCH NOISE-FIGURE COLD LOAD INPUT LINE Fig. 2. The external hot-cold load measurement system. INPUT COPPER-PLATED STAINLESS-STEEL STAINLESS-STEEL NOISE DIODE NOISE-FIGURE INPUT LINE Fig. 3. Standard noise diode measurement with a noise-figure measurement system. measured as a function of frequency, as can be seen in Fig. 4. The data plotted as noise temperature in kelvins without a cryogenic pad clearly show the effect of these noise diode impedance changes on noise-temperature measurements. This is due not only to the variations in noise diode source impedance between the off and on states but also to the pulling of the s input noise temperature by these source impedance changes. In practice, it is difficult to achieve less than a 1- to 2-K variation from one frequency point to another when measuring a 3- to 10-K amplifier. In Fig. 4, the noise diode without a cryogenic attenuator trace not only has peak-to-peak variations higher than the cryogenic attenuator trace, but there also is an offset from the correct noise-temperature value. These errors due to mismatch are very difficult to calibrate. C. Method III: Hot and Cold Loads in the Test-Bed A third method, shown in Fig. 5, overcomes many shortcomings of the standard hot cold load method by using one thermal noise source only in the cryogenic environment along with the (this eliminates many input transmission line calibration difficulties) and attaching a controllable heater to it. When no heat is applied, the load functions as the cold load at a temperature nearly equal to that of the 3

6.5 6.0 5.5 N t NOISE-FIGURE WITHOUT PAD N t NOISE-FIGURE WITH PAD NOISE TEMPERATURE, K 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 2000 2050 2100 2150 2200 2250 2300 2350 2400 2450 2500 2550 2600 FREQUENCY, MHz Fig. 4. A comparison of S-band amplifier module noise measurements using a noise-figure meter with and without a cryogenic pad. STAINLESS-STEEL HOT-COLD LOAD TEMPERATURE SENSOR NOISE-FIGURE HEATER Fig. 5. Diagram of the internal hot-cold load measurement system. refrigerator. Heat is applied to switch the load to a higher temperature. The repeatability problems of the mechanical switch in method I are eliminated, but the slow measurement time remains. One challenge of this approach is to ensure that the impedance change of the thermal load from the cold to the hot temperatures is acceptably small. Another challenge is to ensure that the heater does not heat the input to the amplifier. D. Method IV: Cold Sky and Ambient Aperture Load The method that is still the standard for measuring ultra-low-noise amplifiers is the cold sky ambient aperture load method. Charles Stelzried and Robert Clauss developed this method at JPL for calibrations of low-noise receivers [1,2]. This method uses a calibrated test feedhorn, with a very low side-lobe pattern to minimize ambient noise pickup from the ground, placed at the room-temperature input of the LNA. A radiometer as shown in Fig. 6 is used to measure the power ratio between the sky and an ambient aperture load placed over the feedhorn. This method is accurate for frequencies in the microwave window (from 4

COLD SKY TEST FEED HORN AMBIENT APERTURE LOAD LOW-NOISE AMPLIFIER CLOSED-CYCLE REFRIGERATOR LNA OUTPUT ISOLATOR AMPLIFIER ISOLATOR BANDPASS FILTER POWER TOTAL POWER RADIO Fig. 6. The cold sky-ambient aperture load noise measurement system. about 1 to 12 GHz) where atmospheric weather effects are small, but it must be done outdoors where the sky is unobstructed. This method also has the advantage of measuring a system noise temperature, which is a measurement of the operating noise temperature when the LNA package is installed in an antenna. E. Method V: Noise-Figure Meter With a Cryogenic Attenuator The last method, the cryogenic pad technique shown in Fig. 7, is the method most often employed by the Cryogenics Electronics Front-End Equipment Group for measuring amplifier modules and will be described in the remainder of this article. In this technique, a cold load is provided when the diode noise source is off. In this state, the source noise temperature applied to the is equal to the physical temperature of the cryogenic pad (about ) plus a small contribution (about 3 K) from the ambient temperature noise diode as attenuated by the cryogenic input transmission line and a 20-dB cryogenic attenuator. Turning the 9000-K noise diode on provides the hot load. The noise power then is attenuated by the cryogenic attenuator and, to a very small extent, by the cryogenic input transmission line, resulting in a source noise power at the input of about 90 K. These cold and hot load temperature levels of 18 and 90 K nominally are, from the point of view of measurement error, very satisfactory for the measurement of s having less than 50-K input noise temperatures. This method was first developed and used by Sander Weinreb and Anthony Kerr at the National Radio Astronomy Observatory (NRAO). The method has some advantages over the other methods described. One advantage is that no mechanical switches are needed; hence, rapid measurement speed is possible. A second advantage is that the off-to-on impedance changes of the diode noise source are reduced almost to insignificance by the 20-dB cryogenic pad. Thirdly, insertion loss of the transmission line connecting the cryogenic attenuator and the outside diode noise source contributes much smaller errors. At JPL, this cryogenic attenuator method has been combined with a high-quality commercial noise figure meter. The commercial noise-figure meter provides the necessary wide-frequency-range tunable receiver and power 5

INPUT COPPER-PLATED STAINLESS-STEEL STAINLESS-STEEL NOISE DIODE ATTENUATOR NOISE-FIGURE INPUT LINE Fig. 7. The noise-figure meter with a cryogenic attenuator noise-measurement system. meter that follow the and the object-oriented graphically programmed computer-based controllers to implement a noise-temperature measurement system for cryogenic amplifiers covering the frequency range of 10 MHz to 50 GHz. III. De-embedding The term de-embedding refers to the procedure by which the true hot and cold noise power levels that appear at the input connector of the from the noise diode, input transmission line, and cryogenic attenuator are determined. The information that must be obtained to perform the de-embedding is (1) the excess noise ratio (ENR) of the noise diode, (2) the insertion loss and physical temperature profile of the input and output test-bed transmission lines when the test bed is at normal operating temperature (), and (3) the attenuation and VSWR of the cryogenic attenuator when at normal test-bed operating temperature (). All this information is needed across the frequency range of interest. These items are entered into the computer controller and are used to correct the raw noise-figure meter (NFM) output data. The first step in the above process is to determine the ENR of the noise diode. The noise diode manufacturer often supplies these calibration data. The second step is to make the test-bed input and output lines as symmetrical as possible with respect to the insertion loss and phase of components from the ambient temperature to cryogenic temperature ends. This symmetry greatly facilitates de-embedding. This is accomplished by careful measurement and matching of components making up these lines, such as semirigid cables, waveguides, adapters, vacuum windows, etc. Then, when symmetrical input and output transmission lines are achieved, the input and output transmission lines are connected together in the test-bed. If the input and output connectors are non-mating, then a low-loss through section such as a coaxial air line or waveguide is used. This input line output line circuit then is measured for insertion loss over the frequency bands of interest, using a vector network analyzer. These data are stored for later manipulation. The test-bed then is cooled to operating temperature and the insertion-loss measurement repeated. The insertion loss for the input and output lines is assumed to be one-half of this measured value of the cascade of the two lines The third step is to measure the insertion loss of the cryogenic pad by inserting it between these known input and output lines and repeating the above measurements at both room temperature and cryogenic operating temperature. 6

From the above information, the actual value of the noise power presented to the with the noise diode off and on can be calculated for the frequencies of interest. The NFM then calculates the corrected noise temperature and gain. IV. Noise-Measurement Procedure The is placed in the cryogenic test-bed and connected to the output port of the cryogenic attenuator. The system is cooled to its normal operating temperature of, and a DC bias is applied to the. The NFM is calibrated per the manufacturer s procedure involving attachment of the noise source directly to the microwave equipment behind the test-bed. The noise source then is attached to the test-bed input transmission line, and the NFM input is connected to the output transmission line. The de-embedded data are entered into the NFM via the computer controller; then the corrected noise temperature of the is calculated by the NFM. An example of corrected input noise-temperature data for a 2-GHz amplifier is shown in Fig. 8. 7.0 NOISE TEMPERATURE, K 6.5 6.0 5.5 5.0 4.5 4.0 3.5 3.0 2.5 N t HOT-COLD LOAD N t NOISE-FIGURE WITH COLD PAD 2.0 2000 2050 2100 2150 2200 2250 2300 2350 2400 2450 2500 2550 2600 FREQUENCY, MHz Fig. 8. A comparison of noise-temperature data obtained by the internal hot-cold load method and the noise-figure meter with cold pad. V. Error Analysis The following is a brief explanation of the measurement inaccuracies and their magnitudes. The equations used are from [3]. Errors in the measurement of effective input noise temperature result primarily from errors in measured values of (1) the attenuator and input line losses, L pad, (2) the attenuator physical temperature, T p, and (3) the noise source excess-noise ratio (ENR). The excess noise ratio is defined as ( ) Th ENR = 10 log 290 1 (2) The measurement error of L pad typically is ±0.05 db using the Hewlett Packard (HP)8722D Vector Network Analyzer with Option 400 (four samplers), the Calibration Kit HP85050C, and cables HP85132F. Measurement errors for T physical typically are ±0.25 K using a calibrated Lakeshore Cryogenics Thermometer Model 819 in conjunction with a DT-470 diode sensor. The ENR calibration table accuracy for a 15.00-dB ENR HP346A noise source is ±0.1 db. These values were obtained from [4 6]. 7

Equation (1) can be used to estimate the maximum error in a measurement of T e given the above component measurement errors. Values for T h and T c in Eq. (1) are obtained from the following equations: T h = T nd on L pad + T p ( 1 1 ) L pad (3) where T nd on is the thermal noise temperature, in kelvin, of the diode in the on state, L pad is the total loss of the cryogenic attenuator and cryogenic low-loss input line (in ratio), and T p is the physical temperature of L pad ; and T c = T nd off L pad + T p ( 1 1 ) L pad (4) where T nd off is the thermal noise of the diode in the off state, which is its physical temperature in kelvins. In the measurement of a typical 2- to 2.6-GHz (S-band) HEMT LNA module, the following values are obtained: a typical Y-factor of 8.1 db, which has a ratio value of 6.457, assuming negligible uncertainty in this relative measurement; a typical T p temperature measurement of 12 K with an uncertainty of ±0.25 K; a typical T amb temperature measurement of with an uncertainty of ±0.25 K, a loss measurement of 20 db with an uncertainty of ±0.05 db, and an ENR of 15 db with an uncertainty of ±0.1 db. Another source of error, which was pointed out to the author by R. Clauss, is the effect of the s impedance match on the loss in db value of the attenuator. From [7], and from conversations with T. Otoshi, we get the following formula: pad error max in db = 20 log(1 ± [R 1 R g ]) 1 ± [S 22 R l ] 1 ± [R g R l ] (5) where R 1 is the magnitude of the reflection coefficient of the attenuator on the load, side; R g is the magnitude of the reflection coefficient of the noise diode (generator) side; S 22 is the magnitude of the reflection coefficient of the attenuator on the noise diode side; and R l is the magnitude of the reflection coefficient of the load. Table 1 contains typical values for each parameter obtained in the measurement of a 2-K S-band HEMT LNA and the typical tolerances assigned to each parameter (as discussed above). The resultant error in T e from each of these parameter tolerances is calculated in the right-hand column. Notice that the attenuator loss as a function of match and noise diode ENR error is the largest source of error in the noise-temperature measurement, followed by the relatively equal error contributions from the cryogenic attenuator physical temperature and Y-factor measurements. Adding these six sources of error gives a worst-case error for T e from all causes of ±1.34 K. VI. Conclusion A method of making accurate input noise-temperature measurements of low-noise cryogenic amplifiers using a cryogenic attenuator in a cryogenic test-bed in conjunction with a commercial noise-figure meter and associated diode noise sources has been described. The advantages of this method for laboratory measurements are simplicity, accuracy, and speed of measurement. The data taken with this method agree well with those taken with hot and cold load techniques as shown in Fig. 5 but are obtained much faster and do not display the peak-to-peak ripple caused by the standard hot cold load method. The system in current configuration allows for gain and noise-temperature measurements to be made from 10 MHz to 50 GHz. 8

Table 1. Sources of error in the measurement of effective input noise temperature, T e,ofa. Resultant Parameter Nominal Tolerance error in value T e,k Noise diode ENR 15.0 db ±0.1 db ±0.39 Cryogenic attenuator loss 20.0 db ±0.05 db ±0.16 Cryogenic attenuator 12.0 K ±0.25 K ±0.25 physical temperature Y-factor 8.1 db ±0.05 db ±0.23 Noise diode physical ±0.25 K ±0.01 temperature return loss mismatch 10 db ±10 db ±0.30 Total errors ±1.34 Acknowledgments The author wishes to thank Sam Petty, Jan Loreman, Javier Bautista, and Jim Shell for their help in making this system a reality; Dr. Charles Stelzried and Bob Clauss for their help and input; and Tom Otoshi for his help with the mismatch equations. References [1] R. C. Clauss, H. F. Reilly, and M. S. Reid, Low Noise Receivers: Microwave Maser Development, Space Programs Summary 37-62, The Deep Space Network, January 1 to February 28, 1970, vol. II, Jet Propulsion Laboratory, Pasadena, California, pp. 74 78, March 31, 1970. [2] C. T. Stelzried, Operating Noise Temperature Calibrations of Low-Noise Receiving Systems, Microwave Journal, vol. 14, no. 6, pp. 41 48, June 1971. [3] R. Pettai, Noise in Receiving Systems, New York: John Wiley and Sons, 1984. [4] User guide for Hewlett-Packard HP8722, Hewlett-Packard, Santa Rosa, California, 1996. [5] User guide for Hewlett-Packard HP8970B, Hewlett-Packard, South Queensferry, Scotland, 1993. [6] Temperature Measurement and Control, Lakeshore Cryotronics, Westerville, Ohio, p. A-20, 1995. [7] R. W. Beatty, Mismatch Errors in the Measurement of Ultrahigh-Frequency and Microwave Variable Attenuators, Journal of Research of the National Bureau of Standards, vol. 52, no. 1, pp. 7 9, January 1954. 9