NETWORK ANALYSER MPR-50 / MPR-52S / MPR-60S / MPR-63

Similar documents
Monitoring Electric Network Via Internet

ELECTRICAL MEASURING INSTRUMENTS PROGRAMME

EM330 Installation and use instructions Three-phase energy analyzer for indirect connection (5A) with Modbus, pulse or M-Bus interface

MODEL: LSMT4 [2] INPUT 1: 480 V / 1 A AC 2: 480 V / 5 A AC. Power Transducer Series

Energy Measurement and Management MT MD Multifunction meters with load profile

KW8M. Toward energy savings. Visualization. Makes us more ecological! Eco-POWER METER 1A/5A CT Input type

NGRM700. Neutral Grounding Resistor Monitor

Contrans E - SU. Configurable universal transducer for all power current variables and for mains synchronization 10/ EN

MODEL: R3-WT4B. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series

MODEL: R3-WT4. Remote I/O R3 Series. [4] OPTIONS blank: none /Q: With options (specify the specification) AC POWER INPUT MODULE (4 input circuits)

ENGLISH WM2 - DIN / EM2 - DIN OPERATING INSTRUCTIONS. General features 2. WM2-DIN Technical features 3. EM2-DIN Technical features 9.

A2000 Multifunctional Power Meter

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID

N100. example of application Ethernet www/ ftp. Ethernet TCP IP RS X MeaSUreMent of power network parameters.

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS

SINEAX CAM Universal measuring unit for heavy current variables

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

Series. Quite simply, the best in insulation! C.A 6521 C.A 6523 C.A 6525 C.A 6531 C.A Megohmmeters

CTC CT TRANSMITTER. (clamp-on current sensor) BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MODEL CTC

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

nd30pnet - METER Of POwER NETwORk PARAMETERS with profinet EXAMPlE Of APPlICATION MEASUREMENT ANd VISUAlIZATION Of POwER NETwORk PARAMETERS

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

PRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

MODEL: LTWT. Power Transducer Series LT-UNIT

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

Power analyzers and Energy Meters Power Analyzer Type WM14-96

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Data Sheet. RISH Master Record %THD

Lineup with new energy saving and environmentally friendly features!

RTU560. Multimeter 560CVD03. Power Measuring Display. Characteristics. Application. Data Sheet Multimeter 560CVD03

EM-72 Electricity Meters for Current Transformers

ULTRA RAPID POWER QUALITY ANALYZER

Application: Product Features: On site programmable PT/CT ratios: User selectable CT Secondary 5A/1A. User selectable PT Secondary

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

Multimeter 500CVD21 RTU500 series

MODEL: M5CTC. [4] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz) DC Power R: 24 V DC MODEL: M5CTC [1][2][3] [4][5]

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

ThermaData Logger DATA-LOGGERS. temperature recording thermometers.

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

Provides exact fault location to one span

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

UPM209 1/5A CT, 80A Multifunction three-phase meter

Operating Instructions SINEAX AM3000 ( )

PEM353. Universal measuring device

dtrans ph 01 Microprocessor transmitter/ controller for ph value or redox potential

Energy Management Modular Smart Power Quality Analyzer Type WM3-96

MODEL: M5CTC SEN TRONIC AG

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM4-96

Energy Management Modular Smart Power Transducer Type SPT-90

CVM-C5-ITF-485 CVM-C5-MC-485

APPLICATIONS DATA SHEET. Product: Single Phase AC/DC Power Meter QI-POWER-485

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications.

SUPPLY NETWORK ANALYZER CVM-96 SERIES

3-phase meter with direct connection and pulse or Modbus RS485 output

Energy Division

Energy Management Modular Power Analyzers Type WM2-96

Analizzatore di Rete ADR. Manuale d Uso

ENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

Energy Management Modular Power Quality Transducer Type PQT-90

ISOSCAN EDS440/441. Device variants. Alarm messages are directly indicated on the device display

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

MODEL: M2CEC MODEL: M2CEC-[1][2][3]-[4][5]

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Operating Guide October 2006

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

Universal Measuring Device UMG96L Operating Instructions

COMMUNICATION MODBUS PROTOCOL MFD44 NEMO-D4Le

Arbiter Systems, Inc Vendels Circle, Suite 121 Paso Robles, CA USA

Power Meter Series PM3200 Functions and characteristics

ISOSCAN EDS440/441. Device variants. Alarm messages are directly indicated on the device display

DIRIS A40 DIRIS A41. Functions. Conformity to standards. Applications. Energy management DIRIS A40. Network analysis

Integra 1560 and 1580 Digital Transducer Systems

Model Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output.

Nemo D4-L+ BACNET COMMUNICATION PROTOCOL. BACnet Protocol Implementation Conformance Statement. Date: March, 30 th 2012 Vendor Name:

Side view View from below Rear view

Energy Management Energy meters Type EM2-DIN

Centrale de mesure Power Meter PM500 Merlin Gerin

M.3. Electrical measurement and control. Electrical energy meters for partial consumption

Installation and Operating Instructions

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Digital Multifunction Instrument - Rish Master 3440

N30P DIGITAL PANEL METER

DM-III Multitest & DM-III Multitest F Power Quality Recorders

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

Series 700A Power Processor

Energy Management. Type WM14-DIN Basic Version. How to order WM14-DIN AV5 3 D PGX. Type Selection. Input specifications. CptBSoft

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

NETWORK ANALYZERS Analyzers

Transcription:

ETWOR AAYSER MPR-50 / MPR-52S / MPR-60S / Modbus / Ethernet Gateway Genera MPR-50 : etwor Anayser. MPR-52S : etwor Anayser with THD measurement, R S-45 (MODBUS) and Aarm Contact. MPR-60S: etwor Anayser with THD measurement, R S-45 (MODBUS), Aarm Contact and 1MB Memory. : etwor Anayser with THD, up to 31th Harmonics measurement, R S-45 (MODBUS), Aarm Contact and 1MB Memory. IEC 61000-6-2, IEC 61000-6-4, IEC 61010-1 Modbus Harmonics MEMORY Memory Digita Input ma Anaogue Output Aarm Contact MD Max. Demand Product Code % THD I, THD V 2-31th Harmonics I neutra Aarm Contact Digita Input Energy Puse Output RS-45 Comm. 0(2)-10V 0(4)-20mA Memory Rea Time Coc CD Dispay Pcs / Carton MPR-50 (new) MPR-52S (new) MPR-52S-10 (new) MPR-60S MPR-60S-10 MPR-60S-20 MPR-60S-40 MPR-60S-41-10 -20-40 -41 PC Interface Software (MPR-SW) : MPR-SW is a graphic based software, which enabes remote monitoring via internet or intranet. Pease refer to page 20 for MPR-SW Software. Front Pane View Harmonics View Tabe View 1

ETWOR AAYSER MPR-50 / MPR-52S / MPR-60S / Phase - eutra Votages (V ) eutra Active Power (P) Active Energy - Import (Wh) Phase - Phase Votages (V ) Tota ( I) Reactive Power (Q) Active Energy - Export (Wh) Average Phase - eutra Votage Power Factor (P.F) Apparent Power (S) Reactive Energy - Capacitive (VArh) Average Phase - Phase Votage Cos Tota Active Power ( P) Reactive Energy - Inductive (VArh) Max. Demand Frequency (Hz) Tota Reactive Power ( Q) Phase s (I) Max / Min. Vaues Tota Apparent Power ( S) Measured Parameters ( MPR-50 ) Tota Harmonic Distortion for Votage (THD V %) Tota Harmonic Distortion for (THD I %) Measured Parameters ( MPR-52S / MPR-60S ) Individua Harmonics for Votage - up to 31th Individua Harmonics for - up to 31th Measured Parameters ( ) 247 DEVICES CA BE COECTED SERIAY BY USIG REPEATERS. MAX. 00 mt. MAX. 00 mt. RS45/USB or ETHERET COVERTER RPT-01... #247 #246 REPEATER RPT-1 #31 #1 2

ETWOR AAYSER MPR-50 / MPR-52S / MPR-60S / MODE SPECIFICATIOS Eectrica Parameters Harmonic Measurement Operating Votage etwor Type Accuracy Votage Frequency Active Power Reactive Power Transformer Ratio Votage Transformer Ratio Measurement input Votage Measurement Ranges Votage Frequency Power Energy Power Consumption Burden Demand Time Communication Interface Baud Rate / Adress / Parity Aarm Contact Output Digita Input Functions Input Puse Width Operation Votage Digita Output Energy Puse Output Switch Period Operation Operation Votage Anaog Output (optiona) Dispay Data ogging Memory Mechanica Parameters Equipment Protection Degree of Protection Ambient Operating Temperature Connection / Instaation Dimensions Weight / each Quantity in 1 pacage (new) MPR50 (new) MPR52S THD V%, THD I% MPR60S 5-265V AC / DC ; 50/60 Hz 3-phase / 4-wire (Star) ; 3-phase / 3-wire (Deta) ; 3-phase / 3-wire (Aron) 10 0,5 % ± 2 digit 0,5 % ± 2 digit 0,1 % ± 2 digit 1 % ± 2 digit 2 % ± 2 digit 1...2000 (programmabe) 1,0 4000,0 (programmabe) 1,0-300,0 V AC (P-), 2,0-500,0 V AC (P-P) 5 ma - 5,5 A 1,0-400,0 V 5 ma - 10.000 A 45,0-65,0 Hz 0-4.000 M (W, VAr, VA) 0-99.999.999 Wh, VArh <6VA < 1 VA ( burden), < 0,5 VA (Votage burden) 15 min. (Programmabe via MPR-SW) MODBUS RTU (RS-45) 1.200-3.400 bps / 1-247 / one, Odd, Even Output 1/ Output 2: 2 O reays, 5A, 50 VA (resistive) Output 3/ Output 4:2 Digita Inputs Rea Time / atch 50 msec. (Min.) 5...24VDC, 30VDC (Max.) & 10 for MPR-52S- MPR6x- Output 3 : Active EnergyPuse Output (1 Wh...50 MWh / puse) Output 4 : Reactive EnergyPuse Output (1 VArh...50 MVArh / puse) Min. 1 sec. (100...2500 msec. puse width) Max. 50 ma 5...24V DC, max. 30V DC 0/4-20mA (MPR6X- 40, MPR6x- 41) / 0/2-10V (MPR6x-21) 3,6 CD with Bacight, mm Height Seectabe 2 parameters with Time Stamp (15.000 records) 1 MB Interna Memory S 41 21 MPR63-MPR60 MPR63- / S 21 41 MPR60 - / Doube Isoation ( ) IP40 (front pane), IP54 (Optiona) -5 o C, +55 o C Termina / Fush-mounting with rear terminas 96x96 mm (PR19) 0,9 g pcs 2-31th separatey votage & current THD V%, THD I% 3

ETWOR AAYSER MPR-50 / MPR-52S / MPR-60S / Connection Diagram Dimensions (PR19-96x96mm) 3 Phase with neutra connection 2 3 2 3 Measurement Inputs 3 Phase without neutra connection 2 3 2 3 Measurement Inputs 79.3 70 Votage Measurement Inputs 7 9 10 2 3 RS-45 11 13 14 15 16 GD A B TR Votage Measurement Inputs 7 9 10 2 3 RS-45 11 13 14 15 16 GD A B TR 96 90 1. Reay 1 2. Reay 2 3. PuseA 4. PuseR Externa Suppy 17 1 19 20 21 22 23 24 25 26 Puse A + _ Puse R 1. Reay 1 2. Reay 2 3. PuseA 4. PuseR Externa Suppy 17 1 19 20 21 22 23 24 25 26 Puse A + _ Puse R 96 TYPE PR 19 3 Phase with neutra connection 2 3 3 Phase without neutra Aron connection. 2 3 2 3 Measurement Inputs 2 3 Measurement Inputs Votage Measurement Inputs 7 9 10 2 3 RS-45 11 13 14 15 16 GD A B TR Votage Measurement Inputs 7 9 10 2 3 RS-45 11 13 14 15 16 GD A B TR 1. Reay 1 2. Reay 2 3. Input 1 4. Input 2 Externa Suppy 1. Reay 1 2. Reay 2 3. PuseA 4. PuseR Externa Suppy 17 1 19 20 21 22 23 24 25 26 17 1 19 20 21 22 23 24 25 26-10 MPR-60S-10 MPR-52-10 Input 1 Input 2 + _ Puse A + _ Puse R 3 Phase with neutra connection 2 3 2 3 Measurement Inputs Votage Measurement Inputs 7 9 10 2 3 Anaog Out RS-45 11 13 14 15 16 GD A B TR Anaog Out RS-45 11 13 14 15 16 1. Reay 1 2. Reay 2 3. PuseA 4. PuseR Externa Suppy GD A B TR -41 MPR-60S-41 17 1 19 20 21 22 23 24 25 26 Puse A + _ Puse R Connection diagrams are given for reference. Pease aways chec the atest user manua given with product or downoad from. 4

DIGITA ETWOR AAYSER MPR-53 / EPM-07 Series -96 Modbus / Ethernet Gateway Genera MPR-53 / EPM-07 series measures many parameters of an eectric networ. More than 50 parameters are dispayed. EPM-07 : etwor Anayser. EPM-07S : etwor Anayser with R S-45 (MODBUS). MPR-53 : etwor Anayser with THD measurement. : etwor Anayser with THD measurement and R S-45 (MODBUS). Modbus Harmonics Aarm Contact MD Max. Demand IEC 61000-6-2, IEC 61000-6-4, IEC 61010-1 Product Code % THD I % THD V eutra Digita Input Energy Puse Output Dua Energy Meter 6 Different Energy Cacuation Methods.../5A CT-25 (210A) Aarm Contact RS-45 Comm. Pcs / Carton EPM-07-96 EPM-07 -DI EPM-07S -96 EPM-07S -DI MPR-53-96 MPR-53 -DI -96 -DI -DI-CT25 (new) EPM-07S -DI-CT-25 (new) Optiona - Min. Order Quantity is 200pcs/device. (Soon) PC Interface Software (MPR-SW) : MPR-SW is a graphic based software, which enabes remote monitoring via intranet or internet. new Pease refer to page 20 for MPR-SW Software. -DI-CT25 CT-25 is a Transformer, which is used together with -DI-CT25 mode. It is a unique soution, which repaces conventiona type CTs up to 210A. 5

DIGITA ETWOR AAYSER MPR-53 / EPM-07 Series Phase - eutra Votages (V ) eutra Active Power (P) Active Energy - Import (Wh) Phase - Phase Votages (V ) Tota ( I) Reactive Power (Q) Active Energy - Export (Wh) Average Phase - eutra Votage Power Factor (P.F) Apparent Power (S) Reactive Energy - Capacitive (VArh) Average Phase - Phase Votage Cos Tota Active Power ( P) Reactive Energy - Inductive (VArh) Max. Demand Frequency (Hz) Tota Reactive Power ( Q) Phase s (I) Max / Min. Vaues Tota Apparent Power ( S) Measured Parameters ( EPM-07 / 07S ) Tota Harmonic Distortion for Votage (THD V %) Tota Harmonic Distortion for (THD I %) Measured Parameters ( MPR-53 / ) 247 DEVICES CA BE COECTED SERIAY BY USIG REPEATERS MAX. 00 mt. MAX. 00 mt. RS45/USB or ETHERET COVERTER RPT-01... MPR53S-96 #247 EPM-07S #246 REPEATER RPT-1 #31 MPR53S-DI #1 6

DIGITA ETWOR AAYSER MPR-53 / EPM-07 Series MODE SPECIFICATIOS Functions THD %V, THD %I RS-45 Communication Energy Puse Output Dispay Demand Vaue Dispay Max/Min Vaues Password Protection Eectrica Parameters Operating Votage etwor Type Accuracy Transformer Ratio Votage Transformer Ratio Measurement input Votage Measurement Ranges THD Votage Frequency Power Factor Power Energy Power Consumption Burden Demand Time Communication Interface Baud Rate Address Parity Digita Input Input Puse Width Operation Votage Energy Puse Output Switch Period Operation Operation Votage Dispay Mechanica Parameters Equipment Protection Ambient Operating Temperature Degree of Protection Connection / Instaation Dimensions Weight / each Quantity in 1 pacage EPM-07 - EPM-07S 230 V AC * ±10%; 45 / 65 Hz 3-phase / 4-wire (Star) 3-phase / 3-wire (Deta) 3-phase / 3-wire (Aron) 1% ±1 digit 1 2000 (programmabe) 0, 1 4000,0 (programmabe) 10-300 V AC (-), 10-500 V AC (-) 50 ma - 5,5 A 10-500 V (direct), 10-400 V (with votage transformer) 50 ma - 5,5 A (direct), 50 ma - 10.000 A (with current transformer) 20-90Hz 4 quadrant 0-200M(W,VAr,VA) 0-99 999 999 999,9 Wh, VArh <4VA < 1 VA ( burden), < 0,5 VA (Votage burden) 1-60 min. (programmabe) MODBUS RTU (RS-45) [for EPM-07S & ] 00-3400 bps 1-247 o, odd, even P Transistor Min. 1,6 sec. (400 msec. puse width) Doube Insuation ( 2 Digita Inputs 50 msec. (Min.) 5...24 V DC, 30 V DC (Max.) Max. 50 ma 5 24 V DC, max. 30 V DC Red ED ; 10 mm Height ), Measurement Category III o o -5 C, +55 C IP40 (front pane) MPR-53 Termina / Fush-mounting with rear terminas 96x96 mm (PR19**), DI6 (P26**) 0,6 g (PR19) ; 0,6 g (DI6) pcs (PR19), pcs (DI6) 0-99.9 % 7

45.0 90.0.5 14.0 DIGITA ETWOR AAYSER MPR-53 / EPM-07 Series Connection Diagram Dimensions (PR 19-96x96mm) 79.3 70 96 90 96 TYPE PR 19 (P 26 - DI6) 10. 30.1 7.6 9.5 60.6 26.5 21.5 53.0 5.0 10.0 106.0 TYPE DI / P 26 Connection diagrams are given for reference. Pease aways chec the atest user manua given with product or downoad from.