Digital trigger system for the RED-100 detector based on the unit in VME standard

Similar documents
Peculiarities of the Hamamatsu R photomultiplier tubes

The software and hardware for the ground testing of ALFA- ELECTRON space spectrometer

50 MHz Voltage-to-Frequency Converter

The LUX Experiment Trigger and Data Acquisition Systems. Eryk Druszkiewicz April 15 th 2013

Traditional analog QDC chain and Digital Pulse Processing [1]

A NOVEL FPGA-BASED DIGITAL APPROACH TO NEUTRON/ -RAY PULSE ACQUISITION AND DISCRIMINATION IN SCINTILLATORS

Data Acquisition System for the Angra Project

arxiv: v1 [physics.ins-det] 26 Nov 2015

Development of an analog read-out channel for time projection chambers

PMT Calibration in the XENON 1T Demonstrator. Abstract

Digital coincidence acquisition applied to portable β liquid scintillation counting device

arxiv: v2 [physics.ins-det] 17 Oct 2015

Simulation of Algorithms for Pulse Timing in FPGAs

INDEX. Firmware for DPP (Digital Pulse Processing) DPP-PSD Digital Pulse Processing for Pulse Shape Discrimination

Testing the Electronics for the MicroBooNE Light Collection System

arxiv: v2 [astro-ph.im] 2 Jul 2012

Data Compression and Analysis Methods for High- Throughput Radiation Detector Systems

CAEN. Electronic Instrumentation. CAEN Silicon Photomultiplier Kit

PACS codes: Qx, Nc, Kv, v Keywords: Digital data acquisition, segmented HPGe detectors, clock and trigger distribution

Time-of-flight PET with SiPM sensors on monolithic scintillation crystals Vinke, Ruud

arxiv: v1 [physics.ins-det] 9 Sep 2015

A user-friendly fully digital TDPAC-spectrometer

Gamma Ray Spectroscopy with NaI(Tl) and HPGe Detectors

S4 OPERATION DESCRIPTION IN PAMELA INSTRUMENT

High granularity scintillating fiber trackers based on Silicon Photomultiplier

MuLan Experiment Progress Report

COMPENDIUM OF FRONT-END ELECTRONICS

PoS(PhotoDet 2012)061

event physics experiments

Mass Spectrometry and the Modern Digitizer

Multi-channel front-end board for SiPM readout

Real Time Pulse Pile-up Recovery in a High Throughput Digital Pulse Processor

A Modular Readout System For A Small Liquid Argon TPC Carl Bromberg, Dan Edmunds Michigan State University

Development of a 256-channel Time-of-flight Electronics System For Neutron Beam Profiling

Electronic Instrumentation for Radiation Detection Systems

Physics Experiment N -17. Lifetime of Cosmic Ray Muons with On-Line Data Acquisition on a Computer

arxiv: v1 [physics.ins-det] 7 Jul 2017

This is a repository copy of A two-phase argon avalanche detector operated in a single electron counting mode.

PoS(PhotoDet 2012)022

On the initiation of lightning in thunderclouds (Instrumentation, Supplementary information)

The Trigger System of the MEG Experiment

Arrays of digital Silicon Photomultipliers Intrinsic performance and Application to Scintillator Readout

CAEN. Electronic Instrumentation DPP-PSD. Rev July Digital Pulse Processing for Pulse Shape Discrimination. User Manual UM2580

A small dual-phase xenon TPC with APD and PMT readout for the study of liquid xenon scintillation

MPPC versus MRS APD in two-phase Cryogenic Avalanche Detectors

Implementation of A Nanosecond Time-resolved APD Detector System for NRS Experiment in HEPS-TF

PARTICLE DETECTORS (V): ELECTRONICS

Study of the ALICE Time of Flight Readout System - AFRO

Method for digital particle spectrometry Khryachkov Vitaly

ORTEC. Time-to-Amplitude Converters and Time Calibrator. Choosing the Right TAC. Timing with TACs

CATIROC a multichannel front-end ASIC to read out the SPMT system of the JUNO experiment

A high-performance, low-cost, leading edge discriminator

Electronic Readout System for Belle II Imaging Time of Propagation Detector

PARISROC, a Photomultiplier Array Integrated Read Out Chip

Verification of a novel calorimeter concept for studies of charmonium states Guliyev, Elmaddin

Picosecond Time Analyzer Applications in...

Highlights of Poster Session I: SiPMs

PROGRESS in TOF PET timing resolution continues to

DAQ & Electronics for the CW Beam at Jefferson Lab

How different FPGA firmware options enable digitizer platforms to address and facilitate multiple applications

Time-of-flight PET with SiPM sensors on monolithic scintillation crystals Vinke, Ruud

DarkSide-50. Alessandro Razeto LNGS 26/3/14

astro-ph/ Nov 1996

FAST DIGITIZING TECHNIQUES APPLIED TO SCINTILLATION DETECTORS

ORTEC. Research Applications. Pulse-Height, Charge, or Energy Spectroscopy. Detectors. Processing Electronics

Highly Segmented Detector Arrays for. Studying Resonant Decay of Unstable Nuclei. Outline

GAMMA-GAMMA CORRELATION Latest Revision: August 21, 2007

Study of Silicon Photomultipliers for Positron Emission Tomography (PET) Application

Hardware Trigger Processor for the MDT System

NIM INDEX. Attenuators. ADCs (Peak Sensing) Discriminators. Translators Analog Pulse Processors Amplifiers (Fast) Amplifiers (Spectroscopy)

New method for testing of antenna phased array in X frequency range.

PDF hosted at the Radboud Repository of the Radboud University Nijmegen

KLauS4: A Multi-Channel SiPM Charge Readout ASIC in 0.18 µm UMC CMOS Technology

Final Report Data Acquisition Box

LSC 2013 Advances in Liquid Scintillation Spectrometry A prototype of a portable TDCR system at ENEA

Positron Emission Tomography

LHCb Preshower(PS) and Scintillating Pad Detector (SPD): commissioning, calibration, and monitoring

What s a Counter Plateau. An introduction for the muon Lab

Cosmic Rays in MoNA. Eric Johnson 8/08/03

Performance Assessment of Pixelated LaBr 3 Detector Modules for TOF PET

CAEN Tools for Discovery

Instructions for gg Coincidence with 22 Na. Overview of the Experiment

Thick GEM versus thin GEM in two-phase argon avalanche detectors

LIFETIME OF THE MUON

Effects of Dark Counts on Digital Silicon Photomultipliers Performance

Characterisation of SiPM Index :

Scintillators as an external trigger for cathode strip chambers

Cosmic Ray Muon Detection

Total Absorption Dual Readout Calorimetry R&D

Performance of a Single-Crystal Diamond-Pixel Telescope

Institute for Particle and Nuclear Studies, High Energy Accelerator Research Organization 1-1 Oho, Tsukuba, Ibaraki , Japan

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

PV effectiveness under natural conditions

AIDA-2020 Advanced European Infrastructures for Detectors at Accelerators. Deliverable Report. CERN pixel beam telescope for the PS

A digital method for separation and reconstruction of pile-up events in germanium detectors. Abstract

Nyquist filter FIFO. Amplifier. Impedance matching. 40 MHz sampling ADC. DACs for gain and offset FPGA. clock distribution (not yet implemented)

GEM Detector Assembly, Implementation, Data Analysis

Firmware development and testing of the ATLAS IBL Read-Out Driver card

nanomca 80 MHz HIGH PERFORMANCE, LOW POWER DIGITAL MCA Model Numbers: NM0530 and NM0530Z

A 100MHz voltage to frequency converter

Transcription:

Journal of Physics: Conference Series PAPER OPEN ACCESS Digital trigger system for the RED-100 detector based on the unit in VME standard To cite this article: D Yu Akimov et al 2016 J. Phys.: Conf. Ser. 675 012011 View the article online for updates and enhancements. Related content - RED-100 detector for the first observation of the elastic coherent neutrino scattering off xenon nuclei D Yu Akimov, A K Berdnikova, V A Belov et al. - Status of the RED-100 experiment D.Yu. Akimov, A.K. Berdnikova, V.A. Belov et al. - Design of a ``Digital Atlas Vme Electronics'' (DAVE) module M Goodrick, D Robinson, R Shaw et al. This content was downloaded from IP address 46.3.199.99 on 24/02/2018 at 18:35

Digital trigger system for the RED-100 detector based on the unit in VME standard D Yu Akimov 1,2, V A Belov 1,2, A I Bolozdynya 2, Yu V Efremenko 2,3, V A Kaplin 2 and P P Naumov 2,* 1 SSC RF Institute for Theoretical and Experimental Physics of National Research Centre Kurchatov Institute, 25 Bolshaya Cheremushkinskaya, Moscow, 117218, Russian Federation 2 National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), 31 Kashirskoe highway, Moscow, 115409, Russian Federation 3 University of Tennessee,1408 Circle Dr, Knoxville, TN 37996-1200, USA E-mail: * ddr727@yandex.ru Abstract. The system for forming a trigger for the RED-100 liquid xenon detector has been developed. The trigger can be generated for all types of events required to calibrate the detector and data acquisition, including events with one ionization electron. The system has an event detection mechanism where each event is assigned with the timestamp and event type. The trigger system is required in the systems searching for rare events to keep only the necessary information from the ADC array. The characteristics and implementation of the trigger system that provides high efficiency operation even at low-energy events have been described. 1. Introduction International scientific collaboration COHERENT [1] with the participation of Laboratory for experimental nuclear physics MEPhI created RED-100 detector which is designed to search and study the effect of coherent elastic neutrino-nucleus scattering (CENNS) [2, 3]. Spallation Neutron Source (SNS), Oak Ridge National Laboratory (USA) is considered as a source of neutrinos for measurement. Because of the smallness of the neutrino energy from source expected recoil energy is very low (<10 kev). The RED-100 experimental setup is a two-phase liquid xenon time projection chamber [3]. The principle of operation of such detectors is illustrated in figure 1. Particles interacting with dense noble liquefied gas medium produces excitation and ionization. The excitation creates prompt scintillation (S1 signal). Under the influence of the applied electric field ionization electrons drift along applied electric field towards the surface and then enter into the vapor phase where produce proportional scintillation or electroluminescense (S2 signal). The time difference between S1 and S2 signals defines Z position of the event, while the X-Y position is determined from the pattern of S2 light in the photodetecting system. The 3D event reconstruction allows to define a fiducial volume eliminating potentially background events originated in the vicinity of the detector walls. Measurement of the ratio of S2 to S1 signal amplitudes gives an ability to discriminate between electron recoils and nuclear recoils providing an efficient background rejection. Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. Published under licence by Ltd 1

Figure 1. RED-100 detector scheme and operation principle. Detectors of this type are widely used in measurements of low-energy recoil to search for dark matter [5]. A distinctive feature of emission detectors is the significant (to a few hundred photons per electron) ionization yield of electroluminescence. This allows you to achieve very high sensitivity, up to the registration of single electron ionization (SE) [4]. With such low-energy electroluminescence signal is divided into its component signals of single photoelectrons (SPE), distributed along the entire length of the electroluminescent signal, which in this case is significant 2 microseconds. In the RED-100 detector light signals are registered by two arrays of 19 PMTs each located above and below the active volume (see figure 1). The energy range of ionization from one electron is up to 100 kev, which corresponds to the total number of photons detectable from 10 2 to 5 * 10 5. This puts high requirements on the trigger generation scheme (both the lower threshold and the dynamic range). 2. Statement of the problem Usually simple discrimination of signals in the overall channel after smoothing filter provides the trigger on scintillation and luminescence. In the experiment on SNS expected useful signal is less than 10 SE, which requires a low threshold of the trigger to be lowered to the level of several SE. Amplitude resolution of single-photon pulses PMT is quite large (FWHM 100%), which in the case of analog signals summation lead to high errors in estimating the amount of SPE. The effect of spontaneous emission SE [4,6] creates a background signal greater than useful signal by 2-3 orders [2]. The use of discriminators for each channel, and then the analog summation significantly improves the amplitude resolution, but can be still insufficient. An additional problem is that the scintillation signals can provide the same amount of that SPE as SE, thus have much higher energy and have to be excluded by trigger. To fulfill all requirements for a trigger it was decided to use discriminators in each channel and the digital circuit (Field-Programmable Gate Array - FPGA), receiving signals and precisely counting the incoming SPE. To implement the required functionality it was decided to use a CAEN V1495 digital module with custom firmware and 3 CAEN V895 discriminator modules. The use of FPGA unit in V1495 simplifies modification and enhances capabilities of the trigger system. Firmware Development program was carried out with the use of computer-aided design (CAD) Quartus 9.1. 2

3. Implementation of the trigger system The signals from each PMT come to individual discriminators configured to activation on the SPE, and then go straight into the digital module V1495. The internal structure of the digital module can be divided into four parts: counting units, local trigger units, coincidence unit and event registration unit. Local trigger units form the trigger signal when the input signals according to certain conditions. These signals are sent to a coincidence unit, which determines what types of events should match for generating the main trigger. Event registration unit saves in the internal buffer memory information on the main trigger activation, such as a timestamp and the event type, and generates a signal that starts recording event in an array of ADCs. Upon request, the trigger system transmits information about the registered events from its buffer to the data acquisition system DAQ. SPE counting was implemented by summing the number of pulses in a specified-width time window. The resulting sum is compared with the lower and upper thresholds for this type of event. There are two counting units for an independent pulse counting from upper and lower arrays of the PMT. The width of the time window and the thresholds are set in the registers of V1495 unit by the DAQ system. Functional diagram of the counting unit is shown in figure 2. Figure 2. Functional diagram of the counting unit and local trigger units. The circuit is clocked by the main generator of frequency 100 MHz. The signals from the discriminator (DI) fed to a parallel adder, which every 10 ns summarizes the values of all 19 inputs. Each sum is fed to the subtractor and FIFO, which promotes incoming value through all FIFO words. Thus, the delay time equal 10 ns*(capacity of FIFO). The value of a parallel adder is fed to the subtractor, where it is subtracted from the delayed value from the FIFO. The adder with accumulator summarizes the values obtained from the subtractor, which may be either positive or negative, and each clock cycle stores in the accumulator result being the current count of pulses in the time window. Adjusting the width of the window is implemented as follows. The trigger system provides window width register in which the DAQ computer records the required value. Each clock cycle FIFO gives the number of used words (uw). This number is compared with that which is specified in the window width register, and in case of equality signal to read FIFO (RDreq) is issued. The coincidence unit (figure 3) is implemented on the AND, OR, NOT logic elements. Bits of the channel enable register are set to 1 when the corresponding channels are enabled and for disabled channels bits are set to 0. The output of each local trigger and the output of the corresponding bit are fed to an OR gate with one NOT input. When enabled channels coincide, scheme & (AND) 3

generates signal to indicate a match. This signal enters the latch circuit for generating the output signal duration of 1 µs. The generated trigger signal passes through the circuit specifying the minimum interval between triggers, and if the interval is not violated, is issued to the ADC output array. The generation of the trigger can be disabled by sending signal to the external input inhibit. But event will be registered. Figure 3. Functional diagram of the coincidence unit. Bits of the channel enable register are set to 1 when the corresponding channels are enabled and for disabled channels bits are set to 0. The output of each local trigger and the output of the corresponding bit are fed to an OR gate with one NOT input. When enabled channels coincide, scheme & (AND) generates signal to indicate a match. This signal enters the latch circuit for generating the output signal duration of 1 ms. The generated trigger signal passes through the circuit specifying the minimum interval between triggers, and if the interval is not violated, is issued to the ADC output array. The generation of the trigger can be disabled by sending signal to the external input inhibit. But event will be registered. Event registration unit is a circuit detecting the last arrived local trigger before the coincidence. The type of event is determined by number of channel from a local trigger arrived. The unit is provided with FIFO and time counter (24 bit width). Counter time must be tied to the DAQ time because of its overflow. FIFO depth is 4096 words (32 bit word width). Bits 31-28 are reserved, 27-24 - type of event code, 23-0 - time stamp of event in microseconds. The possibility not to generate the main trigger signal when FIFO overflows, or overwrite the oldest events was implemented. 4. Test results Testing the SPE counting unit was carried out using arbitrary waveform generator, which are configured to generate pulses of known quantity. The maximum operating frequency of the system is 100 MHz, the maximum trigger delay after the appearance of the event is 10 ns. The circuit, part of the basis of the firmware for the on-board FPGA of CAEN V1495, occupied 50% of all its resources. To test the system in the conditions close to the real, simplified model of one channel as part of installation (a photomultiplier in a dark box, the LED lighting it, and the discriminator) was assembled. The pulse of amplitude small enough so that the PMT can register single photoelectrons and 1 ms width was send from the signal generator to the LED. The average number of photoelectrons was varied by changing the amplitude of the supplied signal. The discriminator threshold was set at 4

0.5 SPE amplitude. The signal was fed to a discriminator FlashADC and was recorded in a file together with the sign of the trigger, the trigger was taken from the primary generator. Waveforms was analyzed further using a processing program that finds and counts the number of pulses in each event. Then the histogram distribution of the number of events by the number of pulses in the event for those events where there is a sign of the trigger, and for all events was drawn. The ratio of the histograms shows the efficiency shown in figure 4. Figure 4. The histograms for triggered events and for all events. It is easy to see that the trigger is generated within strictly defined between the lower and upper thresholds (5 SPE and the SPE 16, respectively), while the efficiency is 100%. Operation of the trigger system was also tested in several data sets during a session of measurements carried out by the RED-1 detector (prototype of the RED-100 detector) in December 2013. By results of test defects are not found, the module operates normally. Acknowledgements This study was supported by RF Government under contracts of NRNU MEPhI with the Ministry of Education and Science of 11.G34.31.0049 from October 19, 2011 and within the framework of the Centre for Nanostructured Electronics supported by MEPhI Academic Excellence Project (contract 02.a03.21.0005, 27.08.2013). References [1] Akimov D Yu et al. arxiv:1310.0125 [2] Akimov D Yu et al. 2013 J. Instrum. 8 P10023 [3] Chepel V and Araújo H 2013 J. Instrum. 8 R04001 [4] Akerib D S et al. 2014 Phys. Rev. Lett. 112 9 091303 [5] Santos E et al. 2011 J. High Energy Phys. 1112 115 [6] Akimov D Yu et al. 2012 Instrum. Exp. Tech. 55 423 5