PI734C - Winding 312. Technical Data Sheet APPROVED DOCUMENT

Similar documents
PI734E - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734B - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734F - Winding 28. Technical Data Sheet APPROVED DOCUMENT

PI734F - Winding 07. Technical Data Sheet APPROVED DOCUMENT

PM734D - Winding 312. Technical Data Sheet APPROVED DOCUMENT. Generator Solutions AS

PM734F - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734C - Technical Data Sheet

PI734A - Technical Data Sheet

WDG 12 - Technical Data Sheet

PM734B - Technical Data Sheet. Generator Solutions AS

WDG 71 - Technical Data Sheet

WDG 61 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 51 - Technical Data Sheet

WDG 13 - Technical Data Sheet

WDG 83 - Technical Data Sheet

WDG 07 - Technical Data Sheet

S4L1D-G41 Wdg Technical Data Sheet

S4L1S-D4 Wdg.17 - Technical Data Sheet

S0L1-J1 - Technical Data Sheet

PI144H - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

440 (12) 416 (12) 416 (12) 440 (12)

HCM634G - Technical Data Sheet

PARTNER ALTERNATORS LSA 40-4 Pole

Time constants ( s ) Resistance. Other data - Class H /6600 V kva. Efficiencies ( % )(3 phase - Classe H V kva)

LSA Pole. R 726 Mains paralleling

Low Voltage alternators - 4 pole LSA 47.2

Low Voltage alternators - 4 pole LSA 46.2

LSA R & LSA H 49.1 Low Voltage Alternators - 4 pole

PARTNER ALTERNATORS LSA Pole

TAL 047 Low Voltage Alternator - 4 pole

TAL 049 Low Voltage Alternator - 4 pole

TAL 044 Low Voltage Alternator - 4 pole

ALTERNATOR TECHNICAL DESCRIPTION 1. LSA 53.2 XL13 / 4p. Chargé d'affaire : Karthikeyan GN 1 Moteurs Leroy-Somer +33 (0) xx

Spec Information. Reactances Per Unit Ohms

Spec Information. Reactances Per Unit Ohms

GENERATOR DATA JANUARY 30, 2015

AGN 034 Alternator Reactance

AS440 AUTOMATIC VOLTAGE REGULATOR (AVR)

Packaged Generators: New Kato Engineering Packaged Generator Line: Over 75 Years of Experience: Conformity: Service: Quality Standards:

Application Guidance Notes: Technical Information from Cummins Generator Technologies

Rotek AS440 compatible VOLTAGE REGULATOR (AVR)

Generator Advanced Concepts

APPENDIX 1 to LGIP INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

SPECIFICATION, CONTROLS AND ACCESSORIES

SPECIFICATION, CONTROLS AND ACCESSORIES

ENGINEERING DATA SUBMITTAL For the Interconnection of Generation System

AGN 005 Fault Currents and Short Circuit Decrement Curves

SPECIFICATION, CONTROLS AND ACCESSORIES

Orbital GFI Inverter Series

AGN 022 Conditions for Parallel Operation

AGN 124 AVR Power Supplies

State of North Dakota Engineering data submittal Page 1 For interconnection of distributed generation to Otter Tail Power Company

Sizing Generators for Leading Power Factor

Issued: September 2, 2014 Effective: October 3, 2014 WN U-60 Attachment C to Schedule 152, Page 1 PUGET SOUND ENERGY

Technical Data Sheet for AvK-Alternators

Technical Data Sheet for AvK-Alternators

SYNCHRONOUS MACHINES

Technical Data Sheet for AvK-Alternators

STEADY STATE REACTANCE

Generation Interconnection Study Data Sheet Synchronous Machines

CHAPTER 2 ELECTRICAL POWER SYSTEM OVERCURRENTS

Technical Data Sheet for AvK-Alternators

NORTH CAROLINA INTERCONNECTION REQUEST. Utility: Designated Contact Person: Address: Telephone Number: Address:

AGN 124 AVR Power Supplies

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 2 MW

Alternators Reactance for Nonlinear Loads

APPENDIX B: Generation Interconnection Application Form

SOUTH CENTRAL INDIANA REMC Application for Operation of Member-Owned Small Power Generation Systems

THE UNIVERSITY OF BRITISH COLUMBIA. Department of Electrical and Computer Engineering. EECE 365: Applied Electronics and Electromechanics

Contents. About the Authors. Abbreviations and Symbols

EASTERN ILLINI ELECTRIC COOPERATIVE Application for Operation of Member-Owned Generation

PART 1 OWNER/APPLICANT INFORMATION

Power Processor - Series 700F 10KVA to 150KVA

D I G I T A L V O L T A G E R E G U L A T O R

Code No: R Set No. 1

IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form)

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)

Conventional Paper-II-2011 Part-1A

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 150 KW BUT LESS THAN OR EQUAL TO 550 KW

ECP3 4. Rev. 1. Powered by TCPDF (

McPherson Voltage Regulators 4501 NW 27 Ave Miami FL

Low Voltage Alternators

P. O. BOX 269 HIGHLAND, ILLINOIS, U.S.A PHONE FAX

GENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW

The new Yaskawa Varispeed G7 Inverter

APPLICATION FOR INTERCONNECTION & OPERATIONS OF MEMBER-OWNED GENERATION

PAPER-II (Subjective)

NPE32 4. Rev. 1. Powered by TCPDF (

Owner/Customer Name: Mailing Address: City: County: State: Zip Code: Phone Number: Representative: Address: Fax Number:

OPERATING, METERING AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 25,000 KILOWATTS

TABLE OF CONTENT

AGN 026 Harmonic Voltage Distortion

R448 & R448 V50 A.V.R. Installation and maintenance R 448 ST5 ST3 ST10. Armature + 6- Field X2 Z1 X1 Z2 E+ E- 0V Slow fuse 250V 10 A

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

DATAMAX GENERATORS DATA C E NT E R A P P L I C AT I O N S, TO K W LOW A N D H I G H VO LTAG E, 6 0 A N D 5 0 H Z

Transcription:

- Winding 312 Technical Data Sheet

SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international standards such as BS5000, VDE 0530, NEMA MG1-32, IEC60034, CSA C22.2-100, AS1359. Other standards and certifications can be considered on request. TERMINALS & TERMINAL BOX Standard generators feature a main stator with 6 ends brought out to the terminals, which are mounted on the frame at the non-drive end of the generator. A sheet steel terminal box contains the AVR and provides ample space for the customers' wiring and gland arrangements. It has removable panels for easy access. DESCRIPTION The STAMFORD PI range of synchronous ac generators are brushless with a rotating field. They are separately excited by the STAMFORD Permanent Magnet Generator (PMG). This is a shaft mounted, high frequency, pilot exciter which provides a constant supply of clean power via the Automatic Voltage Regulator (AVR) to the main exciter. The main exciter output is fed to the main rotor, through a full wave bridge rectifier, protected by surge suppression. VOLTAGE REGULATORS The PI range generators, complete with a PMG, are available with one of two AVRs. Each AVR has soft start voltage build up and built in protection against sustained over-excitation, which will de-excite the generator after a minimum of 8 seconds. Underspeed protection (UFRO) is also provided on both AVRs. The UFRO will reduce the generator output voltage proportional to the speed of the generator below a presettable level. The MX341 AVR is two phase sensed with a voltage regulation of ± 1 %. (see the note on regulation). The MX321 AVR is 3 phase rms sensed with a voltage regulation of 0.5% rms (see the note on regulation). The UFRO circuit has adjustable slope and dwell for controlled recovery from step loads. An over voltage protection circuit will shutdown the output device of the AVR, it can also trip an optional excitation circuit breaker if required. As an option, short circuit current limiting is available with the addition of current transformers. Both the MX341 and the MX321 need a generator mounted current transformer to provide quadrature droop characteristics for load sharing during parallel operation. Provision is also made for the connection of the STAMFORD power factor controller, for embedded applications, and a remote voltage trimmer. WINDINGS & ELECTRICAL PERFORMANCE All generator stators are wound to 2/3 pitch. This eliminates triplen (3rd, 9th, 15th ) harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads. The 2/3 pitch design avoids excessive neutral currents sometimes seen with higher winding pitches. A fully connected damper winding reduces oscillations during paralleling. This winding, with the 2/3 pitch and carefully selected pole and tooth designs, ensures very low levels of voltage waveform distortion. SHAFT & KEYS All generator rotors are dynamically balanced to better than BS6861:Part 1 Grade 2.5 for minimum vibration in operation. Two bearing generators are balanced with a half key. INSULATION/IMPREGNATION The insulation system is class 'H', and meets the requirements of UL1446. All wound components are impregnated with materials and processes designed specifically to provide the high build required for static windings and the high mechanical strength required for rotating components. QUALITY ASSURANCE Generators are manufactured using production procedures having a quality assurance level to BS EN ISO 9001. NOTE ON REGULATION The stated voltage regulation may not be maintained in the presence of certain radio transmitted signals. Any change in performance will fall within the limits of Criteria 'B' of EN 61000-6-2:2001. At no time will the steady-state voltage regulation exceed 2%. DE RATES All values tabulated on page 8 are subject to the following reductions 5% when air inlet filters are fitted. 10% when IP44 Filters are fitted. 3% for every 500 metres by which the operating altitude exceeds 1000 metres above mean sea level. 3% for every 5 C by which the operational ambient temperature exceeds 40 C. Note: Requirement for operating in an ambient temperature exceeding 60 C must be referred to the factory. Note: Continuous development of our products entitles us to change specification details without notice, therefore they must not be regarded as binding. Front cover drawing is typical of the product range. 2

CONTROL SYSTEM WINDING 312 SEPARATELY EXCITED BY P.M.G. A.V.R. MX341 MX321 VOLTAGE REGULATION ± 1 % ± 0.5 % With 4% ENGINE GOVERNING SUSTAINED SHORT CIRCUIT REFER TO SHORT CIRCUIT DECREMENT CURVES (page 7) INSULATION SYSTEM PROTECTION RATED POWER FACTOR STATOR WINDING WINDING PITCH WINDING LEADS MAIN STATOR RESISTANCE CLASS H IP23 0.8 DOUBLE LAYER LAP TWO THIRDS 6 0.00126 Ohms PER PHASE AT 22 C STAR CONNECTED MAIN ROTOR RESISTANCE EXCITER STATOR RESISTANCE EXCITER ROTOR RESISTANCE R.F.I. SUPPRESSION BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others WAVEFORM DISTORTION NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0% MAXIMUM OVERSPEED BEARING DRIVE END BEARING NON-DRIVE END WEIGHT COMP. GENERATOR WEIGHT WOUND STATOR WEIGHT WOUND ROTOR WR² INERTIA SHIPPING WEIGHTS in a crate PACKING CRATE SIZE TELEPHONE INTERFERENCE COOLING AIR 1.85 Ohms at 22 C 2250 Rev/Min BALL. 6228 C3 BALL. 6319 C3 1 BEARING 2 BEARING 3018 kg 1445 kg 1257 kg 37.3309 kgm 2 194 x 105 x 154(cm) 50 THF<2% 17.5 Ohms at 22 C 0.063 Ohms PER PHASE AT 22 C 2967 kg 1445 kg 1195 kg 36.33 kgm 2 3091kg 3036kg 194 x 105 x 154(cm) 2.69 m³/sec 5700 cfm 3.45 m³/sec 7300 cfm VOLTAGE STAR 380/220 400/231 415/240 440/254 416/240 440/254 460/266 480/277 kva BASE RATING FOR REACTANCE VALUES 1505 1550 1550 1520 1705 1815 1855 1890 Xd DIR. AXIS SYNCHRONOUS 3.18 2.96 2.75 2.40 3.86 3.67 3.43 3.21 60 TIF<50 X'd DIR. AXIS TRANSIENT 0.19 0.18 0.17 0.15 0.23 0.22 0.21 0.20 X''d DIR. AXIS SUBTRANSIENT 0.14 0.13 0.12 0.11 0.17 0.16 0.15 0.14 Xq QUAD. AXIS REACTANCE 2.05 1.91 1.77 1.55 2.49 2.37 2.22 2.07 X''q QUAD. AXIS SUBTRANSIENT 0.29 0.27 0.25 0.22 0.35 0.33 0.31 0.29 XL LEAKAGE REACTANCE 0.04 0.03 0.03 0.03 0.04 0.04 0.04 0.04 X2 NEGATIVE SEQUENCE 0.20 0.19 0.18 0.15 0.25 0.23 0.22 0.21 X0 ZERO SEQUENCE 0.02 0.02 0.02 0.02 0.03 0.03 0.03 0.03 REACTANCES ARE SATURATED VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATED T'd TRANSIENT TIME CONST. 0.135s T''d SUB-TRANSTIME CONST. 0.01s T'do O.C. FIELD TIME CONST. 2.23s Ta ARMATURE TIME CONST. 0.02s SHORT CIRCUIT RATIO 1/Xd 3

50 Winding 312 THREE PHASE EFFICIENCY CURVES 4

60 Winding 312 THREE PHASE EFFICIENCY CURVES 5

30 50 Winding 312 Locked Rotor Motor Starting Curve 346V 380V 400V 415V 440V 25 PER CENT TRANSIENT VOLTAGE DIP. 20 15 10 5 0 30 25 0 500 1000 1500 2000 2500 3000 3500 LOCKED ROTOR kva 60 380V 416V 440V 460V 480V PER CENT TRANSIENT VOLTAGE DIP. 20 15 10 5 0 0 500 1000 1500 2000 2500 3000 3500 4000 LOCKED ROTOR kva 6

50 Three-phase Short Circuit Decrement Curve. No-load Excitation at Rated Speed Based on star (wye) connection. 100000 SYMMETRICAL ASYMMETRICAL CURRENT (Am ps) 10000 60 1000 Sustained Short Circuit = 5,400 Amps CURRENT (Am ps) 100000 10000 0.001 0.01 0.1 1 10 TIME (secs) SYMMETRICAL ASYMMETRICAL 1000 0.001 0.01 0.1 1 10 TIME (secs) Sustained Short Circuit = 6,100 Amps Note 1 The following multiplication factors should be used to adjust the values from curve between time 0.001 seconds and the minimum current point in respect of nominal operating voltage : Note 2 The following multiplication factor should be used to convert the values calculated in accordance with NOTE 1 to those applicable to the various types of short circuit : 50 60 3-phase 2-phase L-L 1-phase L-N Voltage Factor Voltage Factor Instantaneous x 1.00 x 0.87 x 1.30 380v x 1.00 416v x 1.00 Minimum x 1.00 x 1.80 x 3.20 400v x 1.05 440v x 1.06 Sustained x 1.00 x 1.50 x 2.50 415v x 1.09 460v x 1.10 Max. sustained duration 10 sec. 5 sec. 2 sec. 440v x 1.16 480v x 1.15 All other times are unchanged The sustained current value is constant irrespective Note 3 of voltage level Curves are drawn for Star (Wye) connected machines. 7

Winding 312 / 0.8 Power Factor RATINGS Class - Temp Rise Cont. F - 105/40 C Cont. H - 125/40 C Standby - 150/40 C Standby - 163/27 C 50 Star (V) 380 400 415 440 380 400 415 440 380 400 415 440 380 400 415 440 kva 1400 1445 1445 1415 1505 1550 1550 1520 1570 1615 1615 1590 1615 1660 1660 1630 kw 1120 1156 1156 1132 1204 1240 1240 1216 1256 1292 1292 1272 1292 1328 1328 1304 Efficiency (%) 95.4 95.5 95.6 95.8 95.2 95.4 95.5 95.7 95.1 95.2 95.4 95.6 95.0 95.1 95.3 95.5 kw Input 1174 1210 1209 1182 1265 1300 1298 1271 1321 1357 1354 1331 1360 1396 1393 1365 60 Star (V) 416 440 460 480 416 440 460 480 416 440 460 480 416 440 460 480 kva 1590 1690 1725 1760 1705 1815 1855 1890 1770 1890 1930 1970 1820 1945 1985 2025 kw 1272 1352 1380 1408 1364 1452 1484 1512 1416 1512 1544 1576 1456 1556 1588 1620 Efficiency (%) 95.3 95.4 95.5 95.6 95.2 95.2 95.3 95.4 95.1 95.1 95.2 95.3 95.0 95.0 95.2 95.3 kw Input 1335 1417 1445 1473 1433 1525 1557 1585 1489 1590 1622 1654 1533 1638 1668 1700 DIMENSIONS 8

Head Office Address: Barnack Road, Stamford Lincolnshire, PE9 2NB United Kingdom Tel: +44 (0) 1780 484000 Fax: +44 (0) 1780 484100 www.cumminsgeneratortechnologies.com Copyright 2010, Cummins Generator Technologies Ltd, All Rights Reserved Stamford and AvK are registered trade marks of Cummins Generator Technologies Ltd Cummins and the Cummins logo are registered trade marks of Cummins Inc. PI7C-312-TD-EN-SG-A