Traceability for Oscilloscopes and Oscilloscope Calibrators

Similar documents
Cost-Effective Traceability for Oscilloscope Calibration. Author: Peter B. Crisp Head of Metrology Fluke Precision Instruments, Norwich, UK

PXIe Contents. Required Software CALIBRATION PROCEDURE

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z

Frequency and Time Domain Representation of Sinusoidal Signals

Implementing Automated Oscilloscope Calibration Systems

Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators Extended Specifications

AWG-GS bit 2.5GS/s Arbitrary Waveform Generator

Oscilloscope Calibration Options for 55XX Series Multi-Product Calibrators

Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators

Oscilloscope Calibrator

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z & ANSI/NCSL Z

B. Equipment. Advanced Lab

Voltage Sensors URV5-Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z & ANSI/NCSL Z540.3

Specifications for DS1000CA Series

5520A. Multi-Product Calibrator. Extended Specifications 2005

Supplement. TDS5032 and TDS5034 Digital Phosphor Oscilloscopes

EENG-201 Experiment # 4: Function Generator, Oscilloscope

Oscilloscope calibration Application Note

Fluke 5820A Oscilloscope Calibrator Specifications

Agilent E2695A SMA Probe Head for InfiniiMax 1130 Series Active Oscilloscope Probes. User s Guide

Test & Calibration Benefits from a New Precision RF/Microwave Calibrator

Appendix A: Specifications


5500A. Multi-Product Calibrator. Extended Specifications 2005

For the National Voluntary Laboratory Accreditation Program

N acquisitions, all channels simultaneously, N is selectable from 4, 16, 64, and 128 Inputs

Analog Arts SG985 SG884 SG834 SG814 Product Specifications [1]

Analog Arts SF900 SF650 SF610 Product Specifications

Agilent 8902A Measuring Receiver

ECE 4670 Spring 2014 Lab 1 Linear System Characteristics

CERTIFICATE OF ACCREDITATION

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

Utilizzo del Time Domain per misure EMI

AC Current Probes CT1 CT2 CT6 Data Sheet

SOLICITUD XXVI CONGRESO NACIONAL DE METROLOGIA

NI PXIe-5171R. Contents. Required Software CALIBRATION PROCEDURE

This annex is valid from: to Replaces annex dated:

Arbitrary/Function Waveform Generators 4075B Series

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

5520A. Multi-Product Calibrator. Extended Specifications

CHAPTER 6. Motor Driver

PXIe Contents. Required Software CALIBRATION PROCEDURE

UCE-DSO210 DIGITAL OSCILLOSCOPE USER MANUAL. FATIH GENÇ UCORE ELECTRONICS REV1

Calibration of RF-Voltage on Oscilloscopes

Traceability and Modulated-Signal Measurements

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

UCE-DSO212 DIGITAL OSCILLOSCOPE USER MANUAL. UCORE ELECTRONICS

Experiment 1: Instrument Familiarization (8/28/06)

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

CERTIFICATE OF CALIBRATION

President For the Accreditation Council Certificate Number Valid to January 31, 2010

ME 365 EXPERIMENT 1 FAMILIARIZATION WITH COMMONLY USED INSTRUMENTATION

Experiment 1: Instrument Familiarization

Analog Arts SF990 SF880 SF830 Product Specifications

Test No. 1. Introduction to Scope Measurements. Report History. University of Applied Sciences Hamburg. Last chance!! EEL2 No 1

Technical Specifications Revision 1.20

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

MODEL AND MODEL PULSE/PATTERN GENERATORS

Analog Arts SL987 SL957 SL937 SL917 Product Specifications [1]

Oscilloscope Fundamentals. For Electrical Engineering and Physics Undergraduate Students

Measurement Techniques

Why Modern Servicing Requires Complete Waveform & Circuit Analyzing!

Chapter 5 : Specifications

RF Characterization Report

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ZETEC, INCORPORATED 875, boul. Charest ouest, Suite 100 Quebec, QC, G1N 2C9 CANADA

NI PXI-4461 Specifications

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet

Models 296 and 295 combine sophisticated

Agilent 8560 EC Series Spectrum Analyzers Data Sheet

Agilent E4438C ESG Vector Signal Generator Differential I/Q outputs. Product Note

WaveStation Function/Arbitrary Waveform Generators

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI/NCSL Z & ANSI/NCSL Z540.3

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Limitations And Accuracies Of Time And Frequency Domain Analysis Of Physical Layer Devices

Probing Techniques for Signal Performance Measurements in High Data Rate Testing

LB480A Pulse Profiling USB PowerSensor+ Data Sheet

Power Measurement Basics

Calibration Laboratory Assessment Service CLAS Certificate Number Page 1 of 10

Basic Communication Laboratory Manual. Shimshon Levy&Harael Mualem

Agilent 8560 E-Series Spectrum Analyzers

Calibration Techniques for the Home Lab

Determination of Uncertainty for Dielectric Properties Determination of Printed Circuit Board Material

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AMETEK CO., LTD. NAGOYA OFFICE. (Main Laboratory) Onna, Atsugi-shi, Kanagawa-ken, Japan

772D coaxial dual-directional coupler 773D coaxial directional coupler. 775D coaxial dual-directional coupler 776D coaxial dual-directional coupler

Interpreting Specifications

LB480A Pulse Profiling USB PowerSensor+ Data Sheet

CALIBRATION CMC 2, 4 ( )

HP 8901B Modulation Analyzer. HP 11722A Sensor Module. 150 khz MHz. 100 khz MHz. Technical Specifications. Four Instruments In One

WaveStation Function/Arbitrary Waveform Generators

CIRCUIT-TEST ELECTRONICS

GDS MHz Handheld Digital Oscilloscope New Product Announcement

Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer. Application Note

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Transcription:

Traceability for Oscilloscopes and Oscilloscope Calibrators in relation to RF Voltage measurements Paul C. A. Roberts Fluke Precision Measurement PCAR Traceability for Scope Cal Mar 2006 1

Introduction Scope cal was typically part of DCLF, but nowadays average scope is 1GHz bandwidth Bandwidth of several GHz common Scope cal moving into RF & Microwave domain! Metrologists & Calibration Technicians have to deal with variety of high frequency considerations Loading, Impedance matching, VSWR, etc Understanding how results are influenced and how scope cal methods address them can Simplify the task Reduce errors Improve uncertainty analysis PCAR Traceability for Scope Cal Mar 2006 2

Topics Oscilloscope Architecture & Calibration Requirements Overview Oscilloscope Vertical Accuracy & Bandwidth Calibration Oscilloscope Calibrator Calibration PCAR Traceability for Scope Cal Mar 2006 3

Oscilloscopes Bandwidth from <100MHz to 70GHz Analog, Digital, Sampling High impedance and matched inputs. Waveform displays, cursor measurements, and signal analysis. Variety of high frequency probes available LeCroy Active Probe ±8V - <2.5GHz TekConnect probe ±1.75V - <4GHz Agilent probe ±5V - <2.5GHz PCAR Traceability for Scope Cal Mar 2006 4

Architectures Attenuators Pre Amp Ch1 Analog Real Time : BW to 500MHz Switched 1MΩ/50Ω inputs 50Ω VSWR frequency dependence 50Ω 50Ω Switch Y Ch2 X Trigger Timebase Block diagram of Analog Scope. CRT Attenuators Pre Amp Digital: BW to >10GHz Switched & dedicated 50Ω inputs Avoid aliasing! 50Ω 50Ω Ch1 Ch2 Trigger ADC ADC Memory & Processing Display Block diagram of Digital Scope. Sampling: BW to 70GHz 50Ω inputs Reduced input signal range Samplers Ch1 Ch2 ADC ADC Memory & Processing Trigger Display Block diagram of Sampling Scope. PCAR Traceability for Scope Cal Mar 2006 5

Switched Input Impedance Scopes Scopes with 1MΩ and 50Ω input impedance Single BNC connector, internal switching Internal Termination Input Attenuator & Amplifier Internal Termination Input Attenuator & Amplifier 50Ω 1MΩ 10pF 1MΩ 10pF 50Ω Compensation Network(s) Input capacitance compromises 50Ω impedance Scope designs typically employ compensating networks, often inductive, to improve 50Ω Some peaking/ringing may be observed PCAR Traceability for Scope Cal Mar 2006 6

Loading Effects Capacitance Loading of 50Ohm Source Scope input impedance 0 Rin >>100kΩ, so negligible Cin affects apparent BW Source Scope Response (db) -5-10 -15 Unterminated Cin=25pF Terminated Cin=25pF Terminated Cin=2.5pF 50Ω Rin Cin -20 1 10 100 1000 Frequency (MHz) Source Scope Unterminated with Cin = 25pF: BW 129MHz (And voltage 2x expected value) 50Ω 50Ω Terminated with Cin = 25pF: BW 257MHz Terminated with Cin = 2.5pF: BW 2.6GHz Termination PCAR Traceability for Scope Cal Mar 2006 7

Oscilloscope Calibration Workload Installed Base <100MHz - 500MHz 1GHz-1.5GHz 2GHz - 4GHz > 4GHz Routinely Calibrated (% of installed base) 45% 90% 90% PCAR Traceability for Scope Cal Mar 2006 8

Calibration Requirements Vertical deflection Bandwidth Rise-time/Aberration Horizontal/timebase Trigger Input Impedance Interchannel delay Jitter Analysis Effective Bits PCAR Traceability for Scope Cal Mar 2006 9

Calibration Solutions & Traceability National Standards Vp-p Ohm Farad Hz/s Vrms tr/abs PCAR Traceability for Scope Cal Mar 2006 10

Oscilloscope Calibration Solutions Bandwidth/Accuracy 6.4GHz 25ps/14GHz 2.1GHz Dedicated Scope Calibrators (Multi Channel) Multi-Product Calibrators with scope cal options (Single Channel) 300/600/1100MHz 300/600MHz 250/600MHz PCAR Traceability for Scope Cal Mar 2006 11

Vertical Channel(s) - amplitude accuracy Vertical Amplitude Vertical (Y) Gain Calibration 1M Ohm & 50 Ohm DC Level or LF Square DC Voltage 0V a Applied DC Voltage b Screen Result Zero Reference Peak-to- Peak Voltage a b Applied Pulse Screen Result PCAR Traceability for Scope Cal Mar 2006 12

Vertical Channel(s) - Bandwidth Bandwidth definition: V Definition of -3dB Point: 3 db = 20log10 V BwFreq V Ref 70.7% Bandwidth B 3 db Point Single pole 20dB/decade slope f b f PCAR Traceability for Scope Cal Mar 2006 13

Bandwidth Testing - Leveled Sinewave Apply reference frequency 100% Determine -3dB frequency or check amplitude >-3dB at nominal BW frequency 100% 100% 70% 70% 100% PCAR Traceability for Scope Cal Mar 2006 14

Frequency Response Sinewave testing allows examination of peaks, dips and changing slopes V 70.7% 3 db Point Bandwidth B f b f PCAR Traceability for Scope Cal Mar 2006 15

Bandwidth and Risetime Bandwidth imputed from pulse response test: Bandwidth is related to risetime: BW (MHz) = 350/t r (ns) If response is Gaussian Displayed risetime depends on applied edge risetime: 90% 10% t r display 2 = t r uut 2 + t r pulse 2 Rise Time t r PCAR Traceability for Scope Cal Mar 2006 16

Non-50Ω Input Scopes Source Termination Scope 50Ω 50Ω R IN = 1MΩ, C IN = 10pF 25pF Higher BW scopes tend to have lower C IN 95XX calibrator heads: Short line and internal termination 58XX, 55XX & 9100 calibrators: Cable and external termination Scope input capacitance C IN causes mismatch at high frequency Higher frequencies attenuated by C IN Reduces apparent bandwidth Slows apparent risetime, generates reflections C IN can also interact with transmission line Other effects possible depending on line length, frequency, etc PCAR Traceability for Scope Cal Mar 2006 17

Voltage Mismatch Uncertainty Typical instrument VSWR performance Calibrator: Eg: Fluke 9500B with 9560 VSWR: <1.1 to 550MHz, <1.2 550MHz to 3GHz, <1.35 3GHz to 6GHz Chart shows mismatch error with various UUT VSWRs Scopes: Typical 1GHz scope VSWR <1.5 to 1GHz Typical 4-6GHz scopes VSWR <1.1 to 2GHz <1.3 4GHz to 6GHz some <2.0 at 4GHz Uncertainty % 6% 4% 2% 0% -2% Uncertainty (V) arising from UUT Mismatch v Frequency UUT VSWR 1.02 UUT VSWR 1.02 UUT VSWR 1.1 UUT VSWR 1.1 UUT VSWR 1.2 UUT VSWR 1.2 UUT VSWR 1.6 UUT VSWR 1.6 UUT VSWR 2 UUT VSWR 2 Can be worse on more sensitive ranges Eg: TDS6604 typical VSWR specs 1.3 at 6GHz for >100mV/div -4% -6% 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Frequency (GHz) 4.0 4.5 5.0 5.5 6.0 2.5 at 6GHz for <100mV/div Note: Plots are slightly asymmetric use larger value as worst case ± uncert. PCAR Traceability for Scope Cal Mar 2006 18

Uncertainty Analysis Considerations Scopes are calibrated in terms of voltage not power, so express mis-match error in terms of voltage Voltage Error 1 = 1 100% ( 1± ΓS ΓL ) Alternatively, if errors are small use half the power error Voltage proportional to square root of power Sensitivity coefficient is ½ Treat mis-match errors as one of the Type B (systematic) contributions Mis-match errors have U-shaped distribution Divide by 2 to express at standard uncertainty PCAR Traceability for Scope Cal Mar 2006 19

Converting to BW Uncertainty Example of typical 1GHz scope measured with 9500B and 9530 Plot opposite shows frequency response Displayed amplitude reduces to 0.707 of LF value at 1.121GHz = 3dB BW freq Frequency Response wrt 50kHz (db) 5.0 0.0-5.0-10.0-15.0-20.0-25.0 1GHz Scope Frequency Response (TDS608B) -30.0 0.1 1 10 Frequency (GHz) Frequency Response wrt 50kHz (linear) 1GHz Scope Frequency Response Detail around -3dB point (-3dB@ 1.12GHz) 1.00 0.90 0.80 0.70 0.60 0.50 0.40 0.7 0.9 1.1 1.3 1.5 Frequency (GHz) Slope of response at 1.1GHz is 1.02/GHz From slope of tangent drawn on linear plot opposite at -3dB point More simply, calculate slope from frequencies either side of 3dB point Say 1.0 and 1.2 GHz, giving slope = 1.00/GHz Convert amplitude uncertainty into frequency uncertainty Divide the amplitude uncertainty by the frequency response slope PCAR Traceability for Scope Cal Mar 2006 20

Scope Calibrator Cal Systems 9500 Product Series Factory Calibration Systems PCAR Traceability for Scope Cal Mar 2006 21

Scope Calibrator Calibration Calibrating levelled sine Peak to Peak voltage up to 6GHz Conversion from RMS to pk-pk Absolute RMS voltage measurement up to 100kHz with AC Voltage measurement standard Flatness measurement from 100kHz up to 6GHz with RF power meter & sensor Example flatness uncertainties for 2.5Vp/p to 5Vp/p at 1GHz Power Meter Mismatch Distortion Calibration* 1Yr Stability ±3 C Tempco Linearity & Resolution Combined Noise Connector Repeatability TOTAL (Expanded Unc) B B B B B B A A 95%CL Rect 95%CL Rect U Rect 1σ 1σ 95%CL 1.5% 0.5% 0.015% 0.501% 0.2% 1.0% 0.075% 0.1% 1.62% Tables shows individual type A and B uncertainty contributions. Total is expanded uncertainty after combination in accordance with UKAS M3003. * Power Meter Cal contribution is power uncertainty from cal cert. Photograph showing setup for up to 3.2GHz levelled sine calibration against power meter. 6GHz head has SMA connector, and is calibrated with different sensor. PCAR Traceability for Scope Cal Mar 2006 22

Conclusions The design of dedicated oscilloscope calibration solutions minimise the effect of impedance mis-matches, but calibration technicians and metrologists should be aware of their impact: The effect of scope input VSWR can easily be assessed and included as an uncertainty contribution when making bandwidth tests. Mis-match effects should be considered as having a U-shaped distribution for uncertainty analysis purposes, and be treated with a coverage factor of 2 when converting to standard uncertainty. Mis-match effects can also influence pulse testing results by causing reflections, and excessive observed aberrations or anomalies may be indicative of scope input damage. PCAR Traceability for Scope Cal Mar 2006 23

Useful references Fluke Application Note A Guide to Oscilloscope Calibration using Dedicated or Multiproduct Calibrators Produced by Fluke to accompany the oscilloscope calibrator products Provides guidance for users covering common oscilloscope calibration requirements and calibration procedures. Go to www.fluke.com/us/usen/products/9500b, select application notes to download. European Cooperation for Accreditation Of Laboratories Publication EAL Guide EA-10/07 Calibration of Oscilloscopes (previously EAL-G30) Produced by EAL to harmonise oscilloscope calibration... Provides guidance to national accreditation bodies setting up minimum requirements for oscilloscope calibration and gives advice to calibration laboratories to establish practical procedures... Published June 1997. Go to www.european-acceditation.org, select documents menu to download. Aeroflex/IFR Booklet RF Datamate Booklet Produced by the signal sources group A 76-page guide to commonly used RF data, measurement methods, power measurement uncertainties, etc.. Go to www.aeroflex.com/rfdatamate to order free copy online. Agilent Technologies Application Note Fundamentals of RF and Microwave Power Measurements (Part 3) Power Measurement Uncertainty per International Guides AN 1449-3, literature number 5988-9215EN Part 3 discusses the all-important theory and practice of expressing measurement uncertainty, mismatch considerations, signal flowgraphs, ISO 17025, and examples of typical calculations Go to www.agilent.com, search for AN1449-3 to download. PCAR Traceability for Scope Cal Mar 2006 24