TABLE OF CONTENTS A-1...TABLE OF CONTENTS A-2...GENERAL NOTES B-1 & B-2...GENERAL INFORMATION

Similar documents
TABLE OF CONTENTS A-1...TABLE OF CONTENTS A-2...GENERAL NOTES B-1 & B-2...GENERAL INFORMATION (FASTENER PATTERNS)

TABLE OF CONTENTS A-1

REGAL. Installation Manual


DW HORIZONTAL INSTALLATION

DW VERTICAL INSTALLATION

400 SERIES VERTICAL INSTALLATION

WESTERN WAVE Panel. Horizontal Installation and Technical Information

WESTERN WAVE Panel. Vertical Installation and Technical Information

900 SERIES WALL PANELS

FlexLoc. Technical/Installation Information

KS42 MF SERIES - HORIZONTAL INSTALLATION

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg FACADES - BRICK INDEX SHEET

Revision Date: April 01, Paramount Enclosure

Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.

CFDTT-01. Control Joint Study (General)

MAXIMUM PANEL ATTACHMENT FASTENER SPACING IS 24" O.C. ALL FASTENERS TO PENETRATE WOOD 3/4" MIN. AND METAL FRAMING 1/2" MIN.

PROVEN DEPENDABLE SUSTAINABLE

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

Horizon-Loc. Installation Details 16" COVERAGE C GUID_INSTL_HLOC_160606

DMI FR1511 PANEL (JC) - J CLOSURE DMI WALL PANEL SOFFIT TO WALL PANEL PROVEN DEPENDABLE SUSTAINABLE METAL ENVELOPE SYSTEMS SINCE 1988

TYPICAL FRAMING AND STITCH FASTENER PATTERNS FOR MAX-RIB PANELS

KS SERIES - VERTICAL INSTALLATION

Pocket Door Installation Instructions

Heavy Wall Applied Stop Tube Frame and Door Installation

CONTENTS. Transitions Board and Batten Vertical Installation... 10,11

Ekoroof LiteTile Dimensions

Installation Instructions Split Shake, Staggered Shake, Shingle, Perfection Shingle, and Shapes

ULTRA WINDOW & DOOR EXPANDERS AND RECEIVERS INSTALLATION INSTRUCTIONS

40mm Thermoclick. Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial)

Pebbletex Adhered Mat Design. Typical Details

INSTALLATION INSTRUCTIONS SIDELITE ASSEMBLY SERIES 900 TERRACE DOOR AND SERIES 925 PATIO DOOR

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation.

A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

Installation Instructions

TABLE OF CONTENTS A. PBR

METAL ROOFING INSTALLATION GUIDE

Best Barns USA. the Brookhaven 10' x 16' Assembly Book. revised March 23, 2016

STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS

All Window Installation Instruction

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

eco-shake INSTALLATION INSTRUCTION

SERIES 300 SINGLE HUNG WINDOW INSTALLATION

Curtain Wall Installation Guide

e-lite fabrication/assembly and Installation instructions

MetroCOTTAGE Shingle

Boxed Shed. QUAKER or A-FRAME SIZES: 6 x 8 6 x 10 T1-11Siding

MULTI-STORY FIRE STOPPING ASSEMBLY FRAMED OPENING JAMB (LOW CELL) INDEX SHEET

Brava Old World Slate Installation Guide

Sliding Glass Door Assembly and Installation Guide

Slate Shingle Specifications

BASIC INSTALLATION GUIDE FOR THE PATIO ENCLOSURE

C.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit

Shapes Siding. Perfection Shingles. Chalk Line

GENERAL INSTALLATION GUIDELINES

GENERAL INSTALLATION GUIDELINES

DECRA Shingle Installation Guidelines

E-Z BUILD SHED BUILDING GUIDE 10' 10' 10' 12' 10' 14' 10' 16' 10' 20'

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

SERIES 5001 SLIDING GLASS DOOR PATIO DOORS INSTALLATION GUIDE

Chapter 9. Windows and Exterior Doors

Transom Joining. for Andersen Elliptical Windows over Perma-Shield Gliding Patio Door

SECTION SHEET METAL FLASHING AND TRIM

INSTALLATION GUIDELINES: X25 SERIES using perimeter installation fin

Installation Manual. For Gerard Shingle Products

I n s t a l l a t i o n I n s t r u c t i o n s S E N T I N E L S E R I E S 1 50 SLIDING GLASS DOORS

Storefront Installation Guide

WINDOW INSTALLATION GUIDE

Flushglaze For Framed Openings and Horizontal Panels. Window System Installation Guide

6x6 Maximizer Storage Shed Assembly Manual Version #9 Feb 26th, 2015

Vertical Offset Base and Safety Rail System Installation Instructions

Chapter 16: Roof Steel

YUKON PATIO COVER INSTALLATION INSTRUCTIONS

Vinyl Sliding Glass Door Assembly Instructions

NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING

Installation Guide. Step 3. Valley Flashing. Step 7. Transition Flashings and Accessories. Step 6. Hip and Ridge Installation

Asphalt Shingle Installation at Roof Edges, Intersections and Valleys

STACKING MULTI-SLIDE DOOR SYSTEM

Installation Manual SOLID CORE SIDING

Inspire Aledora Slate Application Guidelines

SLATE & SHINGLE INSTALLATION

BUILDING THE BASIC SHED. Step A: Build the Foundation & Floor Frame

Effective February, 2015

BARRELL VAULT BATTENLESS

Dura-Lock Roof System

VENTED GABLE DETAIL ROOF PANEL GABLE FLASHING 24" C/C MAX. BUTYL SEALANT TAPE ROOF PURLIN FLASH AB-1, AB-2, AB-3, OR AB-4

With Illustrations, Blueprints & Step By Step Details Brought To You By ShedPlansz.Com Click Here To Get More Shed Plans

Hugger Installation. Roof Hugger, LLC P: P.O. Box 1027 F: Odessa, FL

INSTALLATION INSTRUCTIONS

Steel Reinforced Joining Thank you for choosing Andersen. Please leave this guide with building owner.

installation guide Villa

4-lite Patio Door. Installation Instructions

Chapter 9. Windows and Exterior Doors

MULTISLIDE DOORS INSTALLATION GUIDE & SITE PREPARATION

FIG. #1 - ASD & USD 180/280 Shower Door Assembly

POCKETING MULTI-SLIDE DOOR SYSTEM

Effective April 1, 2013

INSTALLATION, STORAGE AND WALL CONSTRUCTION DETAILS

SERIES 300 SINGLE HUNG WITH FIN WINDOW INSTALLATION

Transcription:

TABLE OF CONTENTS PAGE NUMBER: DETAIL DESCRIPTION A-1...TABLE OF CONTENTS A-2...GENERAL NOTES B-1 & B-2...GENERAL INFORMATION MATRIX DETAILS C-1...FASCIA/SOFFIT DETAIL with ANGLE C-2...BUILDING/SOFFIT DETAIL with SOFFIT J C-3...FASCIA/SOFFIT DETAIL with ANGEL C-4...BUILDING/SOFFIT DETAIL with SOFFIT J C-5...FASCIA/SOFFIT DETAIL with F x 1/2" C-6...BUILDING/SOFFIT DETAIL with F x 1/2" C-7...BASE DETAIL C-8...LAP NOTCHING DETAIL C-9...OUTSIDE CORNER DETAIL C-10...INSIDE CORNER DETAIL C-11...HEADER DETAIL C-12...WINDOW SILL DETAIL C-13...JAMB DETAIL DETAILS C-14...FASCIA/SOFFIT DETAIL with ANGLE C-15...BUILDING/SOFFIT DETAIL with CAP C-16...FASCIA/SOFFIT DETAIL with ANGEL C-17...BUILDING/SOFFIT DETAIL with CAP C-18...BUILDING/SOFFIT DETAIL with INSIDE ANGLE C-19...BASE DETAIL C-20...OUTSIDE CORNER DETAIL C-21...INSIDE CORNER DETAIL C-22...HEADER DETAIL C-23...WINDOW SILL DETAIL C-24...JAMB DETAIL A-1

GENERAL NOTES The details shown on the following pages are suggestions or guidelines on how to install Matrix and Marquee-Lok panels. The information shown is accurate and the installation details shown are proven methods of construction, but it is not intended to cover all instances, building requirements, designs or codes. The details may require changes or revisions due to individual project conditions. The installer should follow these recommended details using proper workmanship procedures. It is the responsibility of the designer/installer to ensure the details meet particular building requirements and to assure adequate water-tightness. It must be noted that water-tightness is a function of the installer. McElroy Metal will be held harmless from any and all claims arising from a lack of water-tightness. A proper uniform substructure should be used to avoid any panel distortion. All substructures should be designed to meet all necessary code requirements. The installer should thoroughly familiarize himself/herself with all installation instructions. Before beginning installation of the panels, the installer should examine the substrate to ensure that all supporting members are straight, level and plumb. The panels should be installed plumb, straight and accurately to the adjacent work. No penetrations shall be placed in the panel system by fasteners except as shown on the installation drawings. McElroy Metal can provide all flashings and accessories shown in the installation drawings unless noted otherwise. Installation procedures shall be in accordance with the manufacture's printed instructions, detail or approved shop drawings. Flashing and trim shall be installed true and in proper alignment, with any exposed fasteners equally spaced for the best appearance. Some field cutting and fitting of panels and flashings is to be expected by the installer and minor field corrections are a part of normal installation work. Workmanship shall be of the best industry standards and with installation performed by experienced metal craftsman. Oil canning of metal panels is inherent in the product and is not a cause for rejection. Contents of this manual are subject to change without notice. Because this manual is revised from time to time, users are advised to check the revision date to be sure they have the most current copy in print. To confirm this book is the most current copy, please visit McElroy Metal's web site at http://www.mcelroymetal.com. A-2

GENERAL INFORMATION FASTENER PATTERNS FASTENER MATRIX FASTENER B-1

GENERAL INFORMATION INSTALLATION TECHNIQUES SEE NOTE #2 SEE NOTE #1 FRAMING MEMBER S NOTES: 1. Using hand, push panel until a bow is formed in the panel. 2. Using rubber palmed gloves and an angled forced blow, slap bow with palm of hand to snap male leg into female leg. 3. To verify panels without sealant are fully engaged, panels will slide lengthwise. 4. To separate panels without sealant, slide the panels lengthwise out of the female leg. S SEE NOTE #4 FRAMING MEMBER S B-2

FASCIA/SOFFIT DETAIL WOOD DECKING WOOD FASCIA PANCAKE HEAD MATRIX SOFFIT PANCAKE HEAD ANGLE ANGLE NOTES: 1. Trim to start and end at building lines. 2. Attach trim to blocking with #10-12 x 1" Type A Pancake Head at 2'-0" O.C. 3. Attach panel to sheathing with #10-12 x 1" Type A Pancake Head. FASCIA BOARD ANGLE MATRIX SOFFIT C-1

BUILDING/SOFFIT DETAIL SOFFIT J BUILDING LINE MATRIX SOFFIT SOFFIT J NOTES: 1. Trim to start and end at building lines. 2. Attach trim to blocking with #10-12 x 1" Type A Pancake Head at 2'-0" O.C. 3. Attach panel to sheathing with #10-12 x 1" Type A Pancake Head. BUILDING LINE SOFFIT J MATRIX SOFFIT C-2

FASCIA/SOFFIT DETAIL WOOD DECKING FASCIA BOARD PANCAKE HEAD ANGLE MATRIX SOFFIT NOTES: 1. Trim to start and end at building lines. 2. Attach trim to blocking with #10-12 x 1" Type A Pancake Head at 2'-0" O.C. 3. Attach panel to sheathing with #10-12 x 1" Type A Pancake Head. ANGLE WOOD DECKING FASCIA BOARD PANCAKE HEAD MATRIX SOFFIT ANGLE C-3

BUILDING/SOFFIT DETAIL SOFFIT J BUILDING LINE MATRIX SOFFIT SOFFIT J NOTES: 1. Trim to start and end at building lines. 2. Attach trim to blocking with #10-12 x 1" Type A Pancake Head at 2'-0" O.C. 3. Attach panel to sheathing with #10-12 x 1" Type A Pancake Head. BUILDING LINE MATRIX SOFFIT SOFFIT J C-4

FASCIA/SOFFIT DETAIL FASCIA BOARD MATRIX SOFFIT PANCAKE HEAD F X 1/2" F X 1/2" NOTES: 1. Trim to start and end at building lines. 2. Attach trim to blocking with #10-12 x 1" Type A Pancake Head at 2'-0" O.C. 3. Attach panel to sheathing with #10-12 x 1" Type A Pancake Head. PANCAKE HEAD FASCIA BOARD MATRIX SOFFIT F X 1/2" C-5

BUILDING/SOFFIT DETAIL FASTENER MATRIX SOFFIT F X 1/2" BUILDING LINE F X 1/2" NOTES: 1. Trim to start and end at building lines. 2. Attach trim to wall at 2'-0" O.C. 3. Attach panel to trim with a Pop Rivet @1'-0" O.C. 4. Maximum panel length for this condition is 1'-0". BUILDING LINE FASTENER F X 1/2" MATRIX SOFFIT C-6

BASE DETAIL #30 FELT UNDERLAYMENT MATRIX PERIMETER CLEAT FINISHED FLOOR PERIMETER CLEAT BASE / DRIP NOTES: 1. Trim and Cleat to start and end at building lines. 2. Attach trim to sheathing with #10-12 x 1" Type A Pancake Head at 2'-0" O.C. 3. Attach cleat to sheathing with #10-12 x 1" Type A Pancake Head at 1'-0" O.C. 4. Attach panel to sheathing with #10-12 x 1" Type A Pancake Head. BASE / DRIP #30 FELT UNDERLAYMENT PERIMETER CLEAT MATRIX FINISHED FLOOR BASE / DRIP C-7

LAP NOTCHING DETAIL MATRIX (HORIZONTAL APPLICATION) FIELD NOTCH MALE LEG FIELD NOTCH PROFILE VIEW FEMALE LEG NOTES: 1. Field notch male leg 0'-2" from end of panel and 0'-2" from edge of panel. 2. Field notch female leg 0'-2" from end of panel. FIELD NOTCH MATRIX (HORIZONTAL APPLICATION) FIELD NOTCH ISOMETRIC VIEW C-8

OUTSIDE CORNER DETAIL MATRIX #30 FELT UNDERLAYMENT OUTSIDE CORNER MATRIX OUTSIDE CORNER NOTES: 1. Trim to start and end at building lines. 2. Attach panel to sheathing with #10-12 x 1" Type A Pancake Head. 3. Attach trim to panel with Pop Rivet @1'-0" O.C. #30 FELT UNDERLAYMENT #30 FELT UNDERLAYMENT MATRIX MATRIX OUTSIDE CORNER C-9

INSIDE CORNER DETAIL #30 FELT UNDERLAYMENT MATRIX #30 FELT UNDERLAYMENT INSIDE CORNER MATRIX INSIDE CORNER NOTES: 1. Trim to start and end at building lines. 2. Attach panels to sheathing with #10-12 x 1" Type A Pancake Head. 3. Attach trim to panels with Pop Rivet @1'-0" O.C. #30 FELT UNDERLAYMENT MATRIX #30 FELT UNDERLAYMENT MATRIX INSIDE CORNER C-10

HEADER DETAIL #30 FELT UNDERLAYMENT MATRIX SOFFIT J (FIELD DRILL WEEP HOLES) (1/4" Ø @1'-0" O.C.) SOFFIT J NOTES: 1. Attach trim to sheathing with #10-12 x 1" Type A Pancake Head @2'-0" O.C. 2. Attach panels to sheathing with #10-12 x 1" Type A Pancake Head. #30 FELT UNDERLAYMENT MATRIX SOFFIT J (FIELD DRILL WEEP HOLES) (1/4" Ø @1'-0" O.C.) C-11

WINDOW SILL DETAIL SOFFIT J MATRIX #30 FELT UNDERLAYMENT SOFFIT J NOTES: 1. Attach trim to sheathing with #10-12 x 1" Type A Pancake Head @2'-0" O.C. 2. Attach panels to sheathing with #10-12 x 1" Type A Pancake Head. #30 FELT UNDERLAYMENT SOFFIT J MATRIX C-12

JAMB DETAIL WOOD FRAMING SOFFIT J #30 FELT UNDERLAYMENT MATRIX SOFFIT J NOTES: 1. Attach trim to sheathing with #10-12 x 1" Type A Pancake Head @2'-0" O.C. 2. Attach panels to sheathing with #10-12 x 1" Type A Pancake Head. WOOD FRAMING SOFFIT J #30 FELT UNDERLAYMENT MATRIX C-13

FASCIA/SOFFIT DETAIL FASCIA BOARD (2'-0" O.C.) ANGLE POP RIVOT ANGLE NOTES: 1. Trim to start and end at building lines. 2. Attach trim to blocking with #10-12 x 1" Type A Pancake Head at 2'-0" O.C. 3. Attach panel to sheathing with #10-12 x 1" Type A Pancake Head. FASCIA BOARD ANGLE C-14

BUILDING/SOFFIT DETAIL CAP BUILDING LINE SOFFIT NOTES: 1. Trim to start and end at building lines. 2. Attach trim to blocking with #10-12 x 1" Type A Pancake Head at 2'-0" O.C. 3. Attach panel to sheathing with #10-12 x 1" Type A Pancake Head. CAP BUILDING LINE CAP SOFFIT C-15

FASCIA/SOFFIT DETAIL FASCIA BOARD (2'-0" O.C.) ANGLE ANGLE NOTES: 1. Trim to start and end at building lines. 2. Attach trim to blocking with #10-12 x 1" Type A Pancake Head at 2'-0" O.C. 3. Attach panel to sheathing with #10-12 x 1" Type A Pancake Head. FASCIA BOARD (2'-0" O.C.) ANGLE C-16

BUILDING/SOFFIT DETAIL CAP BUILDING LINE SOFFIT CAP NOTES: 1. Trim to start and end at building lines. 2. Attach trim to blocking with #10-12 x 1" Type A Pancake Head at 2'-0" O.C. 3. Attach panel to sheathing with #10-12 x 1" Type A Pancake Head. BUILDING LINE SOFFIT C-17

BUILDING/SOFFIT DETAIL BUILDING LINE FASTENER INSIDE ANGLE SOFFIT INSIDE ANGLE NOTES: 1. Trim to start and end at building lines. 2. Attach trim to blocking with #10-12 x 1" Type A Pancake Head at 2'-0" O.C. 3. Attach panel to sheathing with #10-12 x 1" Type A Pancake Head. 4. Maximum panel length for this condition is 1'-0". BUILDING LINE FASTENER INSIDE ANGLE SOFFIT C-18

BASE DETAIL BUILDING LINE SUPPORT MEMBER FINISHED FLOOR #10-16 X 1" TEK2 PANCAKE HEAD #10-16 X 1" TEK2 PANCAKE HEAD BASE & DRIP BASE & DRIP NOTES: 1. Trim to start and end at building lines. 2. Attach trim to Support Member with #10-16 x 1" TEK2 Pancake Head at 2'-0" O.C. 3. Attach panel to framing with #10-16 x 1" TEK2 Pancake Head. #10-16 X 1" TEK2 SUPPORT MEMBER FINISHED FLOOR #10-16 X 1" TEK2 BASE & DRIP C-19

OUTSIDE CORNER DETAIL HAT SECTION #10-16 X 1" TEK2 ZEE SPACER OUTSIDE CORNER ZEE SPACER FIELD CUT AS REQUIRED OUTSIDE CORNER ZEE SPACER NOTES: 1. Locate and attach Zee Spacer Trim with #10-16 x 1" TEK2 Pancake Head fasteners. 2. Attach panels with #10-12 x 1" TEK2 Pancake Head fasteners. 3. Attach Outside Corner trim with Pop Rivets @1'-0" O.C.. HAT SECTIONS ZEE SPACER OUTSIDE CORNER ZEE SPACER C-20

INSIDE CORNER DETAIL #10-16 X 1" TEK2 INSIDE CORNER HAT SECTION FIELD CUT AS REQUIRED HAT SECTION #10-16 X 1" TEK2 INSIDE CORNER ZEE SPACER NOTES: 1. Locate and attach Zee Spacer Trim with #10-16 x 1" TEK2 Pancake Head fastener. 2. Attach panels to framing with #10-16 x 1" TEK2 Pancake Head fasteners. 3. Attach Inside Corner with Pop-Rivets @ 1'-0" O.C. HAT SECTION HAT SECTION ZEE SPACER ZEE SPACER INSIDE CORNER C-21

HEADER DETAIL HEADER #10-12 X 1" TEK2 PANCAKE HEAD #10-16 X 1" TEK2 PANCAKE HEAD (@ EACH SEAM) CAP (FIELD DRILL WEEP HOLES) (1/4" Ø @1'-0" O.C.) CAP NOTES: 1. Trim to start and end at door/window framing. 2. Attach trim to header with #10-16 x 1" TEK2 Pancake Head at 2'-0" O.C. 3. Attach panel to framing with #10-16 x 1" TEK2 Pancake Head. HEADER CAP (FEILD DRILL WEEP HOLES) (1/4" Ø @1'-0" O.C.) #10-16 X 1" TEK2 #10-16 X 1" TEK2 PANCAKE HEAD (@ EACH SEAM) C-22

WINDOW SILL DETAIL HEADER CAP (FIELD DRILL WEEP HOLES) #10-16 X 1" TEK2 PANCAKE HEAD #10-16 X 1" TEK2 PANCAKE HEAD CAP NOTES: 1. Trim to start and end at window framing. 2. Attach trim to header with #10-16 x 1" TEK2 Pancake Head at 2'-0" O.C. 3. Attach panel to framing with #10-16 x 1" TEK2 Pancake Head. HEADER CAP (FEILD DRILL WEEP HOLES) #10-16 X 1" TEK2 C-23

JAMB DETAIL JAMB #10-16 X 1" TEK2 PANCAKE HEAD #10-16 X 1" TEK2 PANCAKE HEAD CAP (FIELD DRILL WEEP HOLES) ZEE SPACER ZEE SPACER FIELD CUT AS REQUIRED CAP NOTES: 1. Trim to start and end at window framing. 2. Attach trim to header with #10-16 x 1" TEK2 Pancake Head at 2'-0" O.C. 3. Attach panel to framing with #10-16 x 1" TEK2 Pancake Head. JAMB #10-16 X 1" TEK2 #10-16 X 1" TEK2 ZEE SPACER CAP C-24