Magnetic Micro Testing System Microservo MMT Series C225-E014A

Similar documents
Dynamic and Fatigue Testing Systems C225-E029

SMX-1000 Plus SMX-1000L Plus

General catalog. BESMAK Servo-hydraulic Medium-Capacity fatigue test System with Furnace. 1 BESMAK Material Testing Machines

Infrared Microscope AIM-9000 C103-E103B

Applications of Piezoelectric Actuator

inspexio SMX-225CT FPD HR

Bend Sensor Technology Mechanical Application Design Guide Mechanical Application Design Guide

TEST EQUIPMENT CO., LTD

Desktop Model Endurance

Nexera Method Scouting

Table-Top Universal Testing Instruments. EZ Test C224-E055C

Z4D-F. LED-type Micro Displacement Sensor with Many Features in a Compact Body. Micro Displacement Sensor. Ordering Information.

EZ Test Creating Culinary Science

Metal Film Resistor Kit

Metal Film Resistor Kit

TENSILKUT ENGINEERING

Z500. High-Precision Sensor that Measures and Displays an Object's Profile. Profile Measuring System

New Long Stroke Vibration Shaker Design using Linear Motor Technology

SONOTEC Co., Ltd. SH-3510 / SF-3441 / SF-3400Ⅱ / SF-653 / SF-0102 / SF-30.

SH-3510 / SF-3441 / SF-3400 / SF-653 / SF-0102 / SF-30

STAMPING TECHNOLOGY - CLAMPING RAW PARTS

Clamping filigree parts

INDIAN INSTITUTE OF TECHNOLOGY BOMBAY

Analysis of static and time-variable magnetic fields

DN 16 ISO-KF. Dimensional drawings THERMOVAC TM 101 (mm)

DOC. NO. FT02000-S E FULLY AUTOMATIC PROBER SPECIFICATIONS TOKYO SEIMITSU CO., LTD.

Demagnetizing. Clamping Chucks. Clamping Plates. Lifting Magnets. Holding Magnets. Demagnetizing. Units. Control Electronics. Non-Ferrous Separators

ES Series Features Detecting distance twice that of conventional

CHIP AND DUST EXTRACTION SYSTEMS

5. Transducers Definition and General Concept of Transducer Classification of Transducers

WM en. Zero point clamping system SPEEDY airtec 1

Basic NC and CNC. Dr. J. Ramkumar Professor, Department of Mechanical Engineering Micro machining Lab, I.I.T. Kanpur

PHILTEC PHILTEC FIBEROPTIC SENSORS FROM INNER SPACE TO OUTER SPACE SOLVE YOUR MEASUREMENT PROBLEMS FIBEROPTIC SENSORS

AC/DC Current Probe CT6844/CT6845/CT6846

Magnetic Field Meter EM-191

1.6 Beam Wander vs. Image Jitter

Each Height Master is supplied with a gauge block for reference-height setting. Fitted wooden case supplied. SPECIFICATIONS

Systems. Dynamic Test. Electrodynamic Vibration Test Systems

Parameter Symbol Min Typ Max Unit Note Strip Length L 300±2 mm Active length = 300mm Strip Width W 10±0.2 mm Active width = 10mm 1,3±0, 15

ALFRA PRESS. Made in Germany by ALFRA

RGH34 encoder system. Data sheet L A. RGH34 readhead and RGI34 interface: RGS40 scale:

Digital inductive conductivity transmitter

ULTRASONIC PROBE SONICATOR


Mechanical Vice Grips. Mechanical Wedge Action Grips

Metal Film Fixed Resistor

Micro Vickers Hardness Tester. HMV-G Series C227-E025B

Confocal chromatic sensors and confocal microscope Micrometer measurement of thickness, displacement, position

Technical Explanation for Displacement Sensors and Measurement Sensors

T40FH. Torque flange. Special features. Data sheet

Compact Table-Top Universal Tester. EZ Test C224-E055

Sales: Technical: Fax:

SPECIFICATION FOR APPROVAL 1/8W 0816 LOW RESISTNACE CHIP RESISTOR

ph or ORP Transmitter

P-810 P-830 Piezo Actuators

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

CATALOG No. US FORMTRACER CS Hybrid Surface Contour Measuring Machine

Long-distance Separate-amplifier Proximity Sensors ES Series Features Detecting distance twice that of conventional

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL

Modal Excitation. D. L. Brown University of Cincinnati Structural Dynamics Research Laboratory. M. A. Peres The Modal Shop, Inc Cincinnati, OH

Miniature resistance thermometer Model TR33, thread-mounted

AEC-Q200 Compliant with AEC-Q200 standard. Miniature and light weight. Suit for reflow and wave flow solder

Bend Sensor Technology Mechanical Application Design Guide

n Measurable displacements between n Linearity: max. ± 0.05 % n Housing diameter 12.9 mm n Service life: 10 8 movements

TV-15, 30 AMP (1 Form A) Power Relay

TQ 401 / EA 401 / IQS 451. Proximity System : TQ 401 Proximity Transducer EA 401 Extension Cable IQS 451 Signal Conditioner FEATURES

Non-Contact Capacitance Gauging Instrument & Series 2800 Capacitive Probes

Chip Inductor INTRODUCTION FEATURE AND APPLICATION. Feature. Application

PROXIMITY SENSOR TERMINOLOGY

AEC-Q200 Compliant with AEC-Q200 standard. Miniature and light weight. Suit for reflow and wave flow solder

THT TYPE. Interface unit with built-in DO module FEATURES

PRECISION CUTTING MICRACUT 202

Dual Lock Reclosable Fasteners - Piece Parts

1. This is an integrated product combining a bearing with a rotation sensor that detects the speed and direction of rotation.

MAGNETOSCOP Measurement of magnetic field strengths in the range 0.1 nanotesla to 1 millitesla

Process ph/orp Analysis Systems

GESTER INTERNATIONAL CO.,LTD TEL: FAX:

General-purpose Foil Strain Gages KFGS Series

9/28/2010. Chapter , The McGraw-Hill Companies, Inc.

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T SSI Data Sheet

LTS(3-terminal type self-oscillation formula) series TSP(2-terminal type separate excitation oscillation formula) series

Rota-Sonde DC4500. Smart display with Signal level. Easy alignment with Laser Line. Design for the most difficult applications

Power Metal Fixed Resistors

Non-Ferrous-Metal-Detecting Proximity Sensor (Separate Amplifier Type)

Hybrid Surface Contour Measuring Machine FORMTRACER CS-5000

TQ 402 & TQ 412 / EA 402 / Proximity System : TQ 402 & TQ 412 Proximity Transducers EA 402 Extension Cable IQS 452 Signal Conditioner FEATURES

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Wire Wound Chip Inductor

Temposonics. Magnetostrictive Linear Position Sensors. ET Analog Data Sheet

MANUFACTURING TECHNOLOGY

Sensor Datasheet Collection

confocaldt 2451/2471 Controller

Akiyama-Probe (A-Probe) guide

Manual Moisture determination scales PCE-MA 110

WF12T, WF08T, WF06T, WF04T 0.5%, 0.1% TC50 High Precision Thin Film chip resistors Size 1206, 0805, 0603, 0402

Locks and Catches Catches and Furniture Bolts

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

Akiyama-Probe (A-Probe) guide

Analogue Temperature Transmitter

VIBRATION ANALYZER. Vibration Analyzer VA-12

Transcription:

Magnetic Micro Testing System Microservo MMT Series C225-E014A

Microservo MMT Series Magnetic Micro Testing System In recent years strength evaluation of micro materials and micro parts is increasing its importance in a variety of fields. These include the development of new materials such as composite and superconductive materials; the practical application of micro machines such as micro actuators and micro sensors; the development of lead-free solder joint technology, which is attracting interest with the increasing concern for environmental aspects, and the increasing demands for small and highly functional parts in the electronics and communication industries; and bio-related industries. The Microservo MMT series adopts an electromagnetic actuator with an exceedingly high frequency response for its loading mechanism. By combining this with closed loop control, high speed and high precision control is possible over micro loads and micro displacement.

Features Compact and lightweight body Installation is easy due to lightweight and small body An electrical power source is the only utility required Other utilities such as water and air are unnecessary Quiet operation allows installation at any place Operation noise has been reduced compared to hydraulic systems Easy operation Working Principle (Control of Micro Loads) The load generator is comprised of a permanent magnet and a force coil as shown in the diagram on the right. The permanent magnet is fixed and the coil moves up and down. When a current is passed through the coil, an electromagnetic force F proportional to this coil current is generated according to the following equation: F = 2πrnBI r : coil radius n : turns of coil B I : coil current The micro load is controlled with great precision by generating the electromagnetic force through the control of the coil current using the closed loop system. F N S N Amplitude Characteristics 100 0.01 G 0.1 G 1 G 10 G 100 G This graph shows the relationship between the amplitude and the frequency under sine wave generation (with no load). Amplitude (mm) 10 1 100 cm/sec The characteristics of the frame and load cell are not considered. Compensate for the influence of these factors to obtain the actual amplitude characteristics. These characteristics have been estimated based on the typical characteristics of the ACT used; there will be a variation of about 10% on the frequency axis. 0.1 0.1 0.01 cm/sec 1 0.1 cm/sec 10 1 cm/sec Frequency (Hz) 100 10 cm/sec

Basic Construction of the Microservo MMT Series Quiet actuator operation High-speed tests to 100 Hz Mount actuator above or below, according to the application. Test method not fixed. Easy crosshead positioning. Clamp and rack system. Compact but highly rigid frame Controller is tried and tested with servo-hydraulic systems. Handles both static and dynamic testing. Select the waveform required for the test. Great operability, as power amplifier operations are controlled at the Controller. Shockless circuits when ACT power turned ON/OFF Large test space. Easy installation of environment control devices or microscopes. Alarm circuits as standard for safe operation Highly efficient cooling Requires only AC 100 V. No other equipment needed. 4

Applications Mobile Phones Board bending tests Key pressing tests Liquid crystal compression tests Electrical Parts Endurance testing and vibration testing of connectors, switches, and sensors Lead-Free Solder Tensile tests Shear fatigue tests Electronic Parts Bonding wire tensile tests IC chip shearing tests Lead pull tests Vibration tests Superconductive Materials Tensile testing Materials evaluation at very low temperatures Various Standards Robustness of terminations and integral mounting devices (IEC 60068-2-21) Endurance testing of IC cards (JIS X6305) Medical and Dental Materials Artificial blood vessels Biomaterials Endurance testing of teeth and bones Evaluation of Physical Properties, Endurance and Fatigue Strength for Selection of the right materials for optimized design, Examination of the best structure, Cost reduction, Improving the reliability of products, Development of environmentally friendly products,... etc. Microfibers Tensile testing of carbon fibers, glass fibers and aramid fibers Ceramics High temperature bending tests Medical Products Compression testing of capsules and pills Food Products Texture tests Thin Objects Tensile testing of paper, foil and film MEMS Endurance testing of micro machines, micro elements, and shape-memory alloys Microservo MMT Series Magnetic Micro Testing System 5

Applicable Test Devices Tensile Test Jig Specimen shape: Round bar (ø4) or flat plate (1 mm thickness 5 mm width maximum) Drill Chuck Grip Specimen shape: Round bar (ø0.5 to 3 mm) or flat plate (1 mm thickness 4 mm width maximum) Key Pressing Test Jig Punch tip radius: ø3 Punch material: Rubber Specimen: Mobile phones, keyboards Compression Test Jig Lower platen: ø110 mm Upper platen: ø30 mm * Various compression testing jigs, including tooth type, spherical type and those for key pressing tests, are available. 3-Point Bending Test Jig 4-Point Bending Test Jig Thermostatic Chamber Constant Temperature Water Immersion Test Equipment Punch tip radius width: R2 60mm Support roller radius width: R2 60 mm Support spacing: 20 to 100 mm Punch tip radius width: R2 60 mm Punch span: 20 to 60 mm Support roller radius width: R2 60 mm Support spacing: 20 to 100 mm Temperature range: Room temperature + 10 to 300 C Temperature range: Room temperature + 10 to 50 C Microscope Excitation Table Card Insertion Test Jig X-Y Stage Distance: ± 12.5 mm 6

Control System Controller 4830 Easy-to-use and multi-functional! The next generation of controller... Extremely simple operation using a color LCD and touchpanel Waveform generation with excellent reproducibility Fully digital control with control parameter autotuning and waveform distortion correction functions achieves faithful load waveform reproducibility. Push test function for testing actual objects Achieves stable peak-value control using the test force, even for specimens with "play" (areas where no test force is applied). World-class basic performance The 24-bit high-resolution AD converter and detector-output linearization function achieve Class 0.5 test force accuracy (0.5% indicated value) with a standard system. Waveform display functions Test waveform display functions installed as standard permit the realtime display of time graphs, X-Y graphs, and peak graphs. Major Specifications In combination with Controller 4830 Main Unit Model Part No. Test force Piston stroke Frequency Controlled items Load cell (standard accessory* 1 ) Jigs and test devices Indication accuracy Installation space (W D H) Total weight Power supply MMT-500NV-10 348-20803-00 Max. ± 500 N approx. 150 kg MMT-250NV-10 348-20802-00 Max. ± 250 N MMT-101NV-10 348-20801-00 Max. ± 100 N MMT-101NV-2 MMT-11NV-2 348-20801-01 348-20800-01 Max. ± 10 N Max. ± 10 mm Max. ± 2 mm Max. 100 Hz Max. 60 Hz Test force, piston stroke (can be expanded by adding options) ± 500 N ± 250 N ± 100 N ± 10 N Not included in standard configuration (standard specification). (Select options or consult Shimadzu.) Test force : within ± 0.5% indicated value or within ± 0.02% dynamic max. test force, whichever is larger* 2 Stroke : within ± 1% indicated value or within ± 0.1% max. stroke, whichever is larger 1000 500 1200 mm (approx.) approx. 120 kg approx. 100 kg approx. 80 kg 1ø 100 V 1 kva 1ø 100 V 500 VA *1 Various capacity load cells are available as options. *2 For MMT-11NV-2, this becomes within ± 1% indicated value or within ± 0.02% dynamic max. test force, whichever is larger. CE marked models are available as options. Microservo MMT Series Magnetic Micro Testing System 7

Installation Requirements 1. Avoid the following conditions when installing the device. Large temperature fluctuation (Recommended temperature range: + 10 to + 40 C with temperature fluctuation within ± 5 C) High humidity Direct air blow from air-conditioners Exposure to direct sunlight Dust Vibration (Recommended: below 5 μm) Microservo MMT Series 2. Power source conditions Avoid power sources with large voltage fluctuation (within 100 V ± 10%). When voltage fluctuation is unavoidable, use a dedicated constant voltage power supply. Grounding D Class (Less 100 Ω) External Dimensional Drawings 250 N to 10 N 500 N 1135 Controller 4830 ø200 300 1135 Controller 4830 300 550 350 550 350 Main unit Power amplifier Power amplifier Unit : mm Company names, product/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation or its affiliates, whether or not they are used with trademark symbol TM or. Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own. www.shimadzu.com/an/ For Research Use Only. Not for use in diagnostic procedures. The contents of this publication are provided to you as is without warranty of any kind, and are subject to change without notice. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. Shimadzu Corporation, 2013