The 400, 800, and 2300 Series Raceways, from

Similar documents
The V2100 Series Steel Raceway provides wiring

WIREMOLD Access 5000 Series Raceway

This attractive raceway conceals and

WIREMOLD AL7450 Series Isoduct Aluminum Raceway

DS4000/ALDS4000 Prewired Raceway

Vista CP Consolidation Point

Steel Raceways BASE SECTIONS. SnapMark SMS3000 Series FITTINGS, CONNECTORS & BOXES RIGID COUPLING COUPLING BLANK END FITTING ENTRANCE END

WIREMOLD Flushduct Infloor Duct System

CableSmart 40N2 & 60N2 Series Nonmetallic Surface Raceway System INSTALLATION INSTRUCTIONS Installation Instruction No.: 42138R2 Updated July 2005

Workstation Outlets GigaFlex PS6+ Modules Category 6

PREMISE CONNECTIVITY SYSTEMS

Multi-Service Pedestal Table Boxes for Laboratory Applications

Floor Boxes. Concealed Service Floor Boxes. Engineering Data 663 Series. Faces Plates for 663 Floor Box. 663 Series Floor Box

Sold by: Toll Free: (877)

AESA TECHNOLOGY OF LAN CABLE

Copper Cords. Clarity Patch Cords. Clarity Shielded Patch Cords. Clarity 110 Patch Cords. Custom Assemblies

MAX MODULAR FACEPLATES WORK AREA

Communications Integrators, Inc. June S. Wilson Street, Suite 105 Tempe, Arizona Toll Free (800) Web Site

Cable Management Solutions with DLP TM

05 Pg A75-90.qxp 6/9/2008 9:36 AM Page A75 RACO Floor Boxes

PANDUIT is a Solutions Enabler Partner for IP Communications within the Cisco Technology Developer Program.

Assembly Instructions

PAN-WAY T-70 AND TWIN-70 NON-METALLIC PERIMETER TRUNKING

Gross Automation (877)

1. This Section specifies the ethernet Category 5E data cabling system for buildings and structures.

Trunkingxxxxxx. in aluminium. Industrial Catalogue

Revised

Flush Round Single or Multi-Service Non-Metallic Concrete Floor Box Floor Boxes

Floor Boxes. Flush Service Floor Boxes

Prestige 2Com Technical

Round/Octagon Boxes and Accessories

Distributed Design Series

GENERAL CATALOGUE. Connectivity for workplaces

Answer Power Beam and Boundary Screen

TECHNICAL INFORMATION

CABLE COVER ORGANIZER KIT USER GUIDE AND INSTALLATION INSTRUCTIONS

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION

FLOOR BOXES AND COVERS

END FEED INSTALLATION

Distributed Design D SERIES D8 TWO-WAY 8-INCH HIGH OUTPUT CEILING MOUNT LOUDSPEAKER FEATURES APPLICATIONS

Raised Floor system LIMOGES Cedex. Phone : Fax :

Installing LOW EMR Surface mount IS panels in a Custom Cut Sauna TyloHelo Inc.

Distributed Design D SERIES D6 TWO-WAY 6.5-INCH HIGH OUTPUT CEILING MOUNT LOUDSPEAKER FEATURES APPLICATIONS

Distributed Design D SERIES D10 TWO-WAY 10-INCH HIGH OUTPUT CEILING MOUNT LOUDSPEAKER FEATURES APPLICATIONS

Tylo Custom Infrared Sauna Heater Kit Installing LOW EMR Surface mount IS panels

CMS 803DC. Technical Data Sheet

Instruction Sheet Tool Kit [ ] (for SL Series 110 Jack Connectors)

MT RJ Jack Kits [ ],

Installation Instructions Standalone or continuous run configurations - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS

7.0 WORKSTATION PRODUCTS

CMS 603DC PI. Technical Data Sheet

ExpressTray. Steel Wire Basket Tray. Configuration Methods. B Connection of Straight Sections. A Quiklok Tray Connections at Record Speed

List of Contents. Trunking systems. Selection of surface finish. Equipotential bonding. Cable ladders. Cable trays/ luminaire rails.

Cablelink Plus Flush Technical

Innovative Cable Management. Supplied by

Inde-Pendants Family. 32L Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No Installation instructions for 32L-Rxx-P

MAX International Faceplates

Norwich Technical. Trunking PERIMETER AND DISTRIBUTION. Description CABLE MANAGEMENT. Colour: White only. Material: PVCu. mkelectric.co.

Pinnacle Technical. Bench and Shelf Trunking. cable management perimeter and distribution. Features.

Optical Cable Entry Facility (OCEF) Installation Instructions

CMS 603DC. Technical Data Sheet

Power Matrix Price List

- 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS. Factory pre-installed mud flange TOOLS REQUIRED: Phillips screwdriver, 5/16 nut driver.

Hollywood Style. Theater Dressing Room Make-up Mirror Lighting. Beautiful. 2+2 or SLC Decorative Strip Lights

BLUEMOTION UXP, CDP, SD

Stud Wall Pages

compile system INSTALLATION GUIDE Updated January 2019

(1) F COAXIAL CONNECTOR, (1) RJ11 MODULAR JACK. Application Telephone, CATV; Approval UL 514/1683, CSA

Installation Guide 888-4WB TRAY

PLUG LOAD CONTROL SOLUTIONS PASS & SEYMOUR DEVICES THAT MAKE ENERGY MANAGEMENT AUTOMATIC

Linear Motion and Assembly Technologies Aluminum Framing /07. Die-Cast Foundation Brackets 3-10 & 3-11

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE

Flush Floor system LIMOGES Cedex. Phone : Fax :

Category 7 A /Class F A Products

A. Product Description: Stranded conductor insulated wire.

Install the Housing. Installation Instructions for Entra Round or Square Type IC, Air-tight New Construction Adjustable LED Housing EN3_-LH9_ 1.

SURFACE CLIP MOUNT. 1 Insert lens into channel, measure, and cut to length. Remove lens cover from channel. surface. Attach lens cover and end caps

SMARTfit Functional and Brain Fitness Training Multi-Station Trainer Installation for Stud and Concrete Walls (US)

WaveTrax. Fiber Cable Management System

Rigid PVC Conduit Fittings Injection Molded in Sizes 1/2-6

Rigid PVC Conduit Fittings Injection Molded in Sizes 1/2-6

TH Place, Maspeth, NY Instruction Manual for UNO Exit Signs

Trunkingxxxxxx. aluminium colour U23X. Industrial Catalogue

Product Specifications 6 inch Wall Duct

PLEATED SHADE ARCH INSIDE MOUNT GETTING STARTED. A few simple tools are required: STANDARD HARDWARE

The First Layer of Light. Indirectly. APPLICATION GUIDE

Unequal Flange Rack Installation Instructions

TOGGLER Specialty Anchors

SECTION INTERCOMMUNICATIONS SYSTEMS. A. Section Includes: Manually switched intercommunications systems with the following components:

Installation Instruction

Inde-Pendants Family. 32L Surface Mount Cylinder Plaster Trim, Grid and Drywall Ceiling Types. Document No

LED Neon Light Round

Telephony & Twisted Pair Products

Electrical Wiring Projects

SMARTfit High Intensity Cognitive Training. SMARTfit Trainer Installation Manual for Stud and Concrete Walls Revision 1.3

SECTION BUILDING WIRE AND CABLE

DLP mini trunking. DLP U-PVC trunking system mini-trunking system. DLP U-PVC trunking system and accessories 80 x 50. Comfortable implementation

Inc. BT Series. BW Series

WALL PLATES & SPECIALTIES

Marshall Tufflex. Cable Management. Steel Trunking Systems

Transcription:

400, 800, 2300, 2300D Series Small, Two-Piece, Nonmetallic Raceway Systems Ideal for Low Voltage and Power pplications The 400, 800, and 2300 Series Raceways, from Wiremold/Legrand, are a family of single compartment raceway systems designed for communication or power applications. Ideal for use in classrooms, offices, hotel applications, or anywhere a small, secure, low profile raceway is needed. The 2300BCD Nonmetallic Divided Raceway is ideal for use when power and low voltage cabling are needed in a single raceway. 400, 800, 2300, and 2300D Series Raceway Profiles Features & Benefits n ccommodates communication and/or power wiring. Can be used for communications, computer lines, surveillance systems, fire alarms, outlets, and more. n vailable in three sizes. 400BC, 800BC, and 2300BC sizes provide flexibility for meeting a variety of capacity requirements. Perfect for most small drops and horizontal runs to work stations. n Durable, textured PVC ivory or white finish. Blends with any decor. Paintable using latex paint. Consult factory for custom color options. n Single- and dual-compartment low profile design. Provides functionality and flexibility with aesthetics for single- or dual-service applications. n dhesive backing for low voltage (under 50V) applications. llows base to be pressed onto mounting surface. Speeds installation. n Lightweight and easy to handle. Saves time and labor costs. Standard 5' [1.525m] raceway lengths can be easily installed by one person. Custom lengths up to 10' [3.05m] are also available. n Divided FiberReady fittings. For use with 2300BC and 2300BCD. Full capacity fittings provide 2" [51mm] bend radius. n Over-the-raceway box for 2300 and 2300D. Boxes mount over continuous run of raceway base eliminating the need to cut raceway when locating devices. n Sure-Snap boxes for 2300BCD. Provides flush look and ease of installation. n Snap-on cover. Provides security with access to wiring for changes or additions. n Datacom connectivity options. ccepts industry standard and proprietary devices from a wide range of manufacturers to provide a seamless and aesthetically pleasing interface for voice, data, audio, and video applications at the point of use. n j Listed File E90378 Raceway, E90377 Fittings. ED296R15 Updated March 2009 For latest specs visit www.wiremold.com

400BC, 800BC, 2300BC, 2300BCD Series Raceway System pplication 2338, 2337 417, 817, 2317 2344, 2347, 2348 418, 818, 2318, 2318DFO 8102, 2310, 2310DFO 411, 811, 2311, 2311DFO 406, 806, 2306 415, 815, 2315 417, 817, 2317, 2317DFO NOTE: Illustration shows product applications only. 2315 Tee Fitting cannot be used with 2300BCD Divided Raceway. 400BC, 800BC, 2300BC, 2300BCD Raceway Series Wire Fill Capacities for Power WIRE SIZE O.D. NUMBER OF CONDUCTORS THHN/THWN Inches [mm] 400BC 800BC 2300BC 2300BCD 14 WG 0.111 [2.8] 5 6 25 12 12 WG 0.130 [3.3] 3 5 18 8 10WG 0.164 [4.2] 0 4 12 5 400BC, 800BC, 2300BC, 2300BCD Raceway Series Wire Fill Capacities for Communications O.D. 40% FILL* CBLE/WIRE SIZE inches [mm] 400 800 2300 2300D UNSHIELDED 4-Pair, 24 WG Cat. 3 0.190 [4.8] 1 3 11 5 TWISTED PIR 4-Pair, 24 WG Cat. 5e 0.210 [5.3] 1 3 9 4 4-Pair, 24 WG Cat. 6 0.250 [6.3] 1 2 6 3 4-Pair, 24 WG Cat. 6a** 0.354 [9.0] 0 1 3 1 25-Pair, 24 WG 0.410 [10.4] 0 0 2 1 COXIL RG6/U 0.270 [6.9] 0 1 5 2 FIBER Zip Cord 0.118 x 0.157 [3 x 6] 1 3 12 6 Round 4 Strand Fiber 0.187 [4.8] 1 3 12 6 Round 6 Strand Fiber 0.256 [6.5] 1 2 6 3 * Wire capacity is reduced to allow for proper conductor bend radius and maximum permissible heat rise. ** Category 6 augmented (6a) cable for 10 gigabit ethernet max allowed cable diameter per addenda No. 11 NSI TI/EI 568-B.2. each compartment. 400BC, 800BC, 2300BC, 23000BCD Series 400BC 400BC-WH Low profile, two-piece raceway with snap-on cover vailable in 5' [1.525m and length. 800BC 800BC-WH Supplied with wide adhesive tape along entire length of base. 2300BC 2300BC-WH 2300BCD 2300BCD-WH 400BC 800BC 2300BC 2300BCD 7/16" [11.1mm] 7/16" [11.1mm] 11/16" [17.5mm] 11/16" [17.5mm] 7/8" [22.2mm] 1 5/16" [33mm] 2 1/4" [57mm] 2 1/4" [57mm] 2

400WC 800WC 2300WC 400BC, 800BC, 2300BC, 2000BCD Series Fittings Wire Clip For holding conductors in place. CT NO. 400WC 1/2" [12.7mm] 800WC 1" [25mm] 2300WC 1" [25mm] 418 90 External Elbow For 818 right angle turns around 2318* external corners. CT NO. 418 1 1/2 818 2" [51mm] 2318 2 1/2" [64mm] 406 Cover Clip For covering joint 806 where two pieces of 400BC, 2306 800BC or 2300BC Series Raceway cover come together. PVC-1 PVC Cutter Regular duty cutter. Ideal for use with small nonmetallic raceway. 410B 810B 2310B B CT NO. 406 13/16" [20.6mm] 806 1" [25mm] 2306 2" [51mm] Blank End Fitting For closing open end of 400BC, 800BC, or 2300BC Raceway Series. 8102 Entrance End Fitting For connecting 400 or 800 Series Raceway with 1/2" trade size conduit or armored cable. 1/2" trade size KO on end and bottom. C CT NO. B C 410B 13/16" [20.6mm] 1/2" [12.7mm] 3/8 [9.5mm] 810B 1 1/4" [32mm] 1/2" [12.7mm] 3/8 [9.5mm] 2310B 2 1/4" [57mm] 1" [25mm] 3/8 [9.5mm] 4 1/4" [108mm] 411* 90 Flat Elbow For right angle 2 1/16" turns on same surface. [53mm] 1 3/8" [35mm] 415* Tee For branches at right angles. 2" 3 3/16" [51mm] [81mm] 1 3/8" [35mm] 2 5/32" [55mm] 417* Internal Elbow For surfaces at right angles. 1 7/16" [37mm] 811 90º Flat Elbow For right angle 2311* ** turns on same surface. CT NO. 811 2 1/2" [64mm] 2311 4 3/16" [106mm] 815 Tee For right angles turns on 2315* ** same surface. B CT NO. B 815 4 1/8" [105mm] 2 3/4" [70mm] 2315 6" [152mm] 4 1/8" [105mm] 817 Internal Elbow For surfaces at 2317* right angles. CT NO. 817 2" [51mm] 2317 2 1/2" [64mm] NOTE: No suffix denotes ivory finish. dd WH suffix for white finish. * For 2300BC and 2300BCD Raceway must be mitered to use 2311 and 2318. 2315 cannot be used in divided raceway. 889 Reducing Connector (800-400) For transitioning from 800 to 400 Series Raceway. 2" [51mm] 3

2310 Entrance End Fitting 1/2", 3/4", and 1" trade size KOs for feeding 2300 Series Raceway. 2 7/16" [62mm] 2310DFO 2 3/16" [56mm] 4" [102mm] 400, 800, 2300, 2300D Series and Communication Boxes 1 15/16" [49mm] 4 1/2" [115mm] 6 1/2" [165mm] Bend Radius Divided Entrance End Fitting Divided fitting to feed 2300BC and 2300BCD Series Raceway. Includes 1/2", 3/4" and 1" trade size KOs on back and top. 2389 Reducing Connector (2300BC-400BC) For transitioning from 2300BC to 400BC Series Raceway. 5474 Transition Tap Fitting Makes transition from 5400 Raceway to 7 9/16" [192mm] 3 3/16" [81mm] 2 1/2" [64mm] 400BC, 800BC, 2300BC Series Raceway. 2311DFO Bend Radius Divided Flat Elbow 5 1/2" 90 flat corner with integral [140mm] dividers to provide 2" [51mm] cable bend radius for UTP and fiber optic installations. 5 1/2" [140mm] 2317DFO 3 1/2" [89mm] 2318DFO 3 3/4" [95mm] Bend Radius Divided Internal Elbow 90 internal corner with integral dividers to provide 2" [51mm] cable bend radius for UTP and fiber optic installations. Bend Radius Divided External Elbow 90 external corner with integral dividers to provide 2" [51mm] cable bend radius for UTP and fiber optic installations. 2389 Reducing Connector 3 1/2" [89mm] 3 3/4" [95mm] 5" [127mm] 3 1/4" [83mm] (2300BC-800BC) For transitioning from 2300BC to 800BC Series Raceway. CM-MMB-231 One Insert Multimedia Box - Compatible with 400BC and 3 1/4" [83mm] 800BC Series Raceway. ccepts Pass & Seymour ctivate Inserts and Wiremold Open System Communication Modules. CM-MMB-232 Two Insert FiberReady 5.19" [132mm] Communication Boxes 3 1/4" [83mm] 5.19" [132mm] Multimedia Box - Compatible with 400BC, 800BC, and 2300BC Series Raceway. ccepts Pass & Seymour ctivate Inserts and Wiremold Open System Communications Modules. CM-MMB-233 Three-Insert FiberReady Multimedia Box Compatible with 400BC, 800BC and 2300BC Series Raceway. ccepts Pass & Seymour ctivate Inserts and 5.19" 7 3/4" [132mm] [197mm] Wiremold Open System Communications Modules 2 1/2" [64mm] NOTE: No suffix denotes ivory finish. dd WH suffix for white finish. 4

400BC, 800BC, 2300BC Series Raceway Sure-Snap Device Boxes n Interchangeable covers and bases. Provides installation flexibility. n Large knockout. ccommodates many cable types and quantities. n Cover removes easily. One twist of a screwdriver removes the cover for fast changes. n No screws to assemble. The secure snap assembly requires fewer tools and parts, which means a shorter installation time. 2344 Extra Deep Device Box 2344-2 B 2344 one-gang, 2344-2 two-gang. 2344-2 base has rectangular KO to enable extension from existing single-gang flush wall box and 1/2" and 1" trade size concentric KOs. ccepts NEM Faceplates C Sure-Snap Device Boxes are available in a variety of sizes and depths. 400BC, 800BC, 2300BC Series Raceway Sure-Snap Device Boxes (For Non-Divided Raceways) 2348 Deep Device Box 2348 one-gang, 2348-2 2348-2 two-gang, 2348-3 three-gang. 2348-3 B For deeper switches and devices. 2348, 2348-2, and 2348-3 Bases have rectangular KO to enable extension from existing flush wall box and 1/2" and 1" concentric KOs. ccepts NEM Faceplates. C CT # GNG(s) B C 2344 1 2 3/4" [70mm] 2344-2 2 4.3/4" 4 7/8" 2 3/4" [124mm] [70mm] 2347 Device Box 2347 one-gang, 2347-2 B 2347-2 two-gang. For standard switches and devices. 2347 and 2347-2 Bases have rectangular KO to enable extension from existing flush wall box and 1/2" and 1" trade size concentric KOs. ccepts NEM Faceplates C CT # GNG(S) B C 2348 1 1 3/4" [35mm] 2348-2 2 4 7/8" 1 3/4" [124mm] [44mm] 2348-3 3 7" 1 3/4" [178mm] [44mm] 2348S/51 Shallow Device Box/ Extension Box For shallow switches and receptacles. Base has rectangular KO. ccepts NEM Faceplates. CT # GNG(S) B C 2347 1 1 3/8" [35mm] 2347-2 2 4 7/8" 1 3/8" [124mm] [35mm] NOTE: No suffix denotes ivory finish. dd WH suffix for white finish. ll single-gang bases have a rectangular knockout on the base. 2348MP 7/8" [22mm] Magnetic Deep Device Box (with Grommet) For deeper switches and devices. Magnetic backing. Base has rectangular KO. ccepts NEM Faceplates 1 3/8" [35mm] 5

400BC, 800BC, 2300BC Series Raceway Round Fixture Boxes for Non-Divided Raceway Item Description Cat. No. Diameter Depth Specifications Blank Cover 2336 4 1/2" [114mm] Use with any round nonmetallic device box to convert into junction box. Round 2337 5 1/2" [140mm] 1" [25mm] For hanging fixtures, smoke/fire alarms and Extension other security devices with 3 1/2" [89mm] or Box 4 1/16" [103mm] mounting centers. 5 1/2" [140mm] diameter with open base. Not for use with ceiling fans. Fixture Box 2338 5 1/2" [140mm] 1" [25mm] For hanging smoke/fire alarms and other security devices with 3 1/2" [89mm] or 4 1/16" [103mm] mounting centers. Not for use with ceiling fans. NOTE: No suffix denotes ivory finish. dd WH suffix for white finish. The 2300BC and 2300BCD Series Divided Raceway Box family provides two unique benefits; labor savings with over-theraceway installation and Sure-Snap device boxes. The 2348D and 2344D over-the-raceway design eliminates cutting the raceway base to mount boxes. The base snaps on anywhere along the raceway. The Sure-Snap integral device box of the 2344SD-2 combines aesthetics with labor savings. 5507 Series Faceplates, Pass & Seymour ctivate Inserts, Wiremold Open System Communication Modules and Ortronics Series II and TracJack Modules snap directly into the Sure-Snap Device Box, eliminating the need for additional faceplates. The single-gang boxes accept standard NEM faceplates. 2348D 1 3/4" [44mm] 2344D 2 3/4" [70mm] Sure-Snap Device Boxes for 2300BCD Divided Series Raceway Device Box For use with 2300BCD Divided Raceway. For mounting standard switches, receptacles and industry standard faceplates for communication devices. ccepts NEM Faceplates. Extra Deep Device Box For use with 2300BCD Divided Raceway when additional depth is required. For mounting standard switches, receptacles and industry standard faceplates for communication devices. ccepts NEM Faceplates. 2344SD-2 Two-Gang Deep Divided Box divided two-gang box for use 2 1/4" [57mm] 4 7/8" [124mm] with 2300D Series Raceway. Provides the ability to have both power and low voltage at a single point of use. ccepts 5507 Series Faceplates, Ortronics TracJack & Series II Modules, Pass & Seymour ctivate Series Inserts, and Wiremold Open System Communication Modules. Note: Not for use with NEM Faceplates. CM-EPL End Plates are required when using Wiremold Open System communication modules and Pass & Seymour ctivate inserts. S2-EPL End Plates are required when using Ortronics Series II inserts. To mount Ortronics TracJack modules, use 5507-4TJ or 5507-6TJ Faceplates. 2344SD-2 Over-the-Raceway Box pplication 2344SD-2 5507 Series Faceplate Communication Inserts 6

5507D Modular Furniture dapter For mounting ctivate modular furniture bezels and other modular furniture adapters. Not for use with rectangular (decorator) style devices. 5507B Blank Faceplate For covering unused compartments in the device bracket. 5507 Series Faceplates 5507RJ 5507FRJ Dual RJ11/RJ45 Connector Faceplate For mounting one or two RJ type connectors has one opening and a KO for the other. Flush Dual RJ11/RJ45 Connector Faceplate Same as 5507RJ except the connectors are recessed to provide a flush installation. 5507D Duplex Receptacle Faceplate For covering duplex style devices. ccepts 106 Frame. 5507-4TJ Ortronics Faceplate For mounting Ortronics datacom inserts. ccepts four TracJack Devices. 5507R Rectangular Receptacle Faceplate For covering rectangular decorator style devices. 5507-6TJ Ortronics Faceplate For mounting Ortronics datacom inserts. ccepts six TracJack Devices. 5507S 5507SW Rectangular Spacer For mounting commercial device plates. Installs between the device bracket and a device. Switch Faceplate For covering standard toggle switches. CM-EPL End Plates Includes two outlet identification labels with clear covers and two matching screw covers. Required for mounting Pass & Seymour ctivate and Wiremold Open System communication modules into the 2344SD-2. 5507T1 Single Receptacle Faceplate For covering single receptacles 1.59" [40mm] diameter. 5507T2 Single Receptacle Faceplate For covering single receptacles 1.41" [36mm] diameter. S2-EPL End Plates Includes two outlet identification labels with clear covers and two matching screw covers. Required for mounting Ortronics Series II modules into the 2344SD-2. NOTE: No suffix denotes ivory finish. dd WH suffix for white finish, and G for Gray finish. Consult factory for custom colors. 7

Datacom Connectivity Options Now you have a wide range of options for providing datacom connectivity into Wiremold Cable Management Systems. They are: Ortronics TracJack and Series II Modular Connectivity Solutions Pass & Seymour ctivate Modular Inserts Open System Communication Modules Use these icons to determine connectivity options for each Wiremold System component: Ortronics Connectivity TracJack Individual Jack System Front-loading, snap-in design supports future moves adds and changes Inserts for voice, data, audio, and video vailable Category 3, 5e, 6, USOC 6-position, and other media Flat or angled 45 exit configurations Choice of 13 colors and color matched to Wiremold Systems Universal T568/B wiring format Series II Front-Loading, Module System Module design features easy snap-in front-loading design Linear 110 punch down format for easy termination Inserts for voice, data, audio, and video vailable Category 3, 5e, 6, USOC 6-position, and other media vailable in flat or angled 45 exit configurations Color matched to Wiremold Systems For detailed product selection refer to the Ortronics Catalog or visit www.ortronics.com. Pass & Seymour Legrand Network Wiring ctivate Series Front-Loading Inserts Modular inserts for voice, data, audio and video applications Front-load, snap-in design Color and texture matched to Wiremold Systems vailable Category 3, 5e, 6, as well as 6-position USOC Universal T568/B wiring format For detailed product selection refer to the Pass & Seymour Network Wiring Catalog or visit www.passandseymour.com. Open Connectivity Solutions Wiremold Open System Communications Modules ccommodate a wide range of manufacturers communications outlets including keystone jacks, as well as proprietary solutions from vaya (Systimax) and NORDX Modules insert into a wide range of Wiremold Systems Pre-punched faceplates accept common communication devices NOTE: For more information on integrating connectivity into Wiremold Cable Management Systems contact the Wiremold pplications Engineering Team or your local Wiremold Sales Representative. Wiremold/Legrand U.S. and International: 60 Woodlawn Street West Hartford, CT 06110 1-800-621-0049 FX 860-232-2062 Outside U.S. 860-233-6251 Canada: 570 pplewood Crescent Vaughan, Ontario L4K 4B4 1-800-723-5175 FX 905-738-9721 Copyright 2009 Wiremold/Legrand ll Rights Reserved ED296R15 Updated March 2009 For latest specs visit www.wiremold.com 8