RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Similar documents
RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17LLBM asymmetrical flashing relay s V AC - solid state output

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

RE11RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

RENF22R2MMW Zelio Timer Relay - Modular

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O

RE7CP13BU adjustable symmetrical flashing relay s - 24 V AC DC - 2OC

RE7RL13BU off-delay timing relay with control contact s - 24 V AC DC - 2OC

RE7TP13BU adjustable on-delay timing relay s - 24 V AC DC - 2OC

ZBRRA Programmable receiver - 2 relays V AC/ DC - 2 pusbuttons - 6 LEDs

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC

RE Product data sheet Characteristics. universal plug-in timing relay V AC - 1 C/O. Main. Complementary. Discrete output type

RXG12BD interface plug-in relay - Zelio RXG - 1C/O standard - 24VDC-10A-with LTB and LED

08/07/2015

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

ZBRT2 double actions (up/down) transmitter for wireless and battery less pushbutton

02/11/2015

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

22/10/2012

08/07/2015

02/11/2015

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

02/11/2015

02/11/2015

RXG21BD interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB

24/07/2012

11/03/2013

ATS01N106FT soft starter for asynchronous motor - ATS01-6 A V KW

05/09/2012

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

02/11/2015

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

Multi-voltage Multi-function. Wiring diagram (without control signal)

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

PART NUMBERING SYSTEM

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

27/04/2015

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

83 Series - Modular timers 16 A. Features

Zelio Control Measurement Relays

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

PART NUMBERING SYSTEM


ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

LXM32CD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

83 SERIES. 83 Series - Modular timers A. Features

Chronos 2 electronic timers mm

Chronos 2 electronic timers - Plug-in 8-pin (35 mm)

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

Type Nominal voltage (V) Code HSV V

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

Multi-function 11 pin Plug-in for use with 90 series sockets

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

LXM32MD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Multi-voltage Multi-function. BE: Off-delay with control signal BE: Off-delay with control signal CE: On- and off-delay with control signal

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

Modular timers A

LXM32AD18M2 motion servo drive - Lexium 32 - single phase supply voltage 115/230V - 0.5/1kW

LXM32MU60N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Solid-state Timer H3DS

VW3A4552. Price* : USD. ATV31CU22N4 - motor choke - 1 per drive. ATV31CU22N4 - line choke - 1 per drive

LXM32AD72N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Type CP-S, CP-C & CP-A Switch mode

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Electronic timer CT-MFS.21

VW3A4554 line/motor choke - 1 mh - 31 A - 3 phases - 90 W - for variable speed drive

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

38 Series - Relay interface modules A

CP-T range Product group picture

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

38 Series - Relay interface modules A

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

ILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

17.5mm Chronos 2 Timers

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Transcription:

Characteristics time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC Product availability : Stock - Normally stocked in distribution facility Price* : 75.00 USD Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay range Nominal output current Complementary Contacts type and composition Contacts material Control type [Us] rated supply voltage Voltage range Feb 18, 2018 Zelio Time Modular timing relay Relay 0.69 in (17.5 mm) RE17R Di B Ac D H Bw A C At Ht 1...10 min 6...60 min 1...10 h 10...100 h 6...60 s 0.1...1 s 1...10 s 8 A 1 C/O Cadmium free Selector switch on front panel 12...240 V AC/DC at 50/60 Hz 0.85...1.1 Us 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

Supply frequency 50...60 Hz (+/- 5 %) Input voltage Connections - terminals 5 V Screw terminals, clamping capacity: 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12 (solid) without cable end Screw terminals, clamping capacity: 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14 (solid) without cable end Screw terminals, clamping capacity: 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14 (flexible) with cable end Screw terminals, clamping capacity: 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16 (flexible) with cable end Tightening torque 5.31...8.85 lbf.in (0.6...1 N.m) conforming to IEC 60947-1 Housing material Self-extinguishing Repeat accuracy +/- 0.5 % conforming to IEC 61812-1 Temperature drift Voltage drift +/- 0.05 %/ C +/- 0.2 %/V Setting accuracy of time delay +/- 10 % of full scale at 25 C conforming to IEC 61812-1 Impulse duration 100 ms with load in parallel typical 30 ms typical Insulation resistance 100 MOhm at 500 V DC conforming to IEC 60664-1 Reset time On-load factor 100 % Power consumption in VA Power consumption in W Minimum switching current Maximum switching current Maximum switching voltage Breaking capacity Operating rate in Hz Electrical durability Mechanical durability 120 ms on de-energisation typical 0...3 VA at 240 V AC <= 1.5 W at 240 V DC 10 ma at 5 V DC 8 A AC/DC 250 V AC <= 2000 VA 10 Hz 100000 cycles resistive load (8 A at 250 V AC maximum) 10000000 cycles Dielectric strength 2.5 kv 1 ma/1 minute 50 Hz conforming to IEC 61812-1 [Uimp] rated impulse withstand voltage Delay response Marking 5 kv (1.2/50 µs) < 100 ms Creepage distance 4 kv/3 conforming to IEC 60664-1 Safety reliability data Mounting position CE MTTFd = 296.8 years B10d = 270000 Any position in relation to normal vertical mounting plane Mounting support 35 mm DIN rail conforming to EN/IEC 60715 Local signalling Product weight LED indicator on steady: relay energised, no timing in progress LED indicator flashing: timing in progress (80 % ON and 20 % OFF) LED indicator pulsing: relay de-energised, no timing in progress (except function Di-D, Li-L) (5 % ON and 95 % OFF) 0.15 lb(us) (0.07 kg) Environment Immunity to microbreaks <= 20 ms Standards EN 61000-6-1 EN 61000-6-4 EN 61000-6-2 2004/108/EC EN 61000-6-3 IEC 61812-1 2006/95/EC Product certifications Ambient air temperature for storage Ambient air temperature for operation CULus GL CSA -22...140 F (-30...60 C) -4...140 F (-20...60 C) IP degree of protection IP20 (terminal block) conforming to IEC 60529 2

IP40 (housing) conforming to IEC 60529 IP50 (front panel) conforming to IEC 60529 Vibration resistance 20 m/s² (f = 10...150 Hz) conforming to IEC 60068-2-6 Shock resistance 15 gn (duration = 11 ms) conforming to IEC 60068-2-27 Relative humidity 93 % without condensation conforming to IEC 60068-2-30 Electromagnetic compatibility Electrostatic discharge immunity test, in contact at 6 kv conforming to IEC 61000-4-2 level 3 Electrostatic discharge immunity test, in air at 8 kv conforming to IEC 61000-4-2 level 3 Susceptibility to electromagnetic fields, 80 MHz to 1 GHz at 10 V/m conforming to IEC 61000-4-3 level 3 Electrical fast transient/burst immunity test, capacitive connecting clip at 1 kv conforming to IEC 61000-4-4 level 3 Electrical fast transient/burst immunity test, direct at 2 kv conforming to IEC 61000-4-4 level 3 1.2/50 µs shock waves immunity test, differential mode at 1 kv conforming to IEC 61000-4-5 level 3 1.2/50 µs shock waves immunity test, common mode at 2 kv conforming to IEC 61000-4-5 level 3 Conducted RF disturbances, 0.15...80 MHz at 10 V conforming to IEC 61000-4-6 level 3 Voltage dips and interruptions immunity test, 1 cycle at 0 % conforming to IEC 61000-4-11 Voltage dips and interruptions immunity test, 25/30 cycles at 70 % conforming to IEC 61000-4-11 Conducted and radiated emissions conforming to EN 55022 class B Ordering and shipping details Category 22370 - RE, RM MISC TIMERS & COUNTERS Discount Schedule CP2 GTIN 00785901660323 Nbr. of units in pkg. 1 Package weight(lbs) 0.17000000000000001 Returnability Y Country of origin ID Offer Sustainability Sustainable offer status RoHS (date code: YYWW) REACh Product environmental profile Product end of life instructions Green Premium product Compliant - since 1243 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold Available Available 3

Dimensions Drawings Width 17.5 mm 4

Connections and Schema Internal Wiring Diagram 5

Connections and Schema Wiring Diagram 1) Contact Y1: Control for functions B, C, Ac, Bw, Ad, Ah, N, O, W, T, Tt. Partial stop for functions At, Ht and Pt. Function D if Di selected. Not used for functions A, H and P. 6

Function A : Power on Delay Relay The timing period T begins on energisation. After timing, the output(s) R close(s). The second output can be either timed or instantaneous. Function: 2 Outputs 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.) 7

Function Ac : On- and Off-Delay Relay with Control Signal After power-up, closing of the control contact C causes the timing period T to start (timing can be interrupted by operating the Gate control contact G). At the end of this timing period, the relay closes. When control contact C re-opens, the timing T starts. At the end of this timing period T, the output reverts to its initial position (timing can be interrupted by operating the Gate control contact G). The second output can be either timed or instantaneous. Function: 2 Outputs 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.) 8

Function At : Power on Delay Relay (Summation) with Control Signal After power-up, the first opening of control contact C starts the timing. Timing can be interrupted each time control contact closes. When the cumulative total of time periods elapsed reaches the pre-set value T, the output relay closes. T = t1 + t2 +... 9

Function B : Interval Relay with Control Signal After power-up, pulsing or maintaining control contact C starts the timing T. The output R closes for the duration of the timing period T then reverts to its initial state. 10

Function Bw : Double Interval Relay with Control Signal On closing and opening of control contact C, the output R closes for the duration of the timing period T. 11

Function C : Off-Delay Relay with Control Signal After power-up and closing of the control contact C, the output R closes. When control contact C re-opens, timing T starts. At the end of the timing period, the output(s) R revert(s) to its/their initial state. The second output can be either timed or instantaneous. Function: 2 Outputs 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.) 12

Function D : Symmetrical Flasher Relay (Starting Pulse Off) Repetitive cycle with two timing periods T of equal duration, with output(s) R changing state at the end of each timing period T. The second output can be either timed or instantaneous. Function: 2 Outputs 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.) 13

Function Di : Symmetrical Flasher Relay (Starting Pulse On) Repetitive cycle with two timing periods T of equal duration, with output(s) R changing state at the end of each timing period T. The second output can be either timed or instantaneous. Function: 2 Outputs 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.) 14

Function H : Interval Relay On energisation of the relay, timing period T starts and the output(s) R close(s). At the end of the timing period T, the output(s) R revert(s) to its/ their initial state. The second output can be either timed or instantaneous. Function: 2 Outputs 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.) 15

Function Ht : Interval Relay (Summation) with Control Signal On energisation, the output R closes for the duration of a timing period T then reverts to its initial state. Pulsing or maintaining control contact C will again close the output R. Timing T is only active when control contact C is released and so the output R will not revert to its initial state until after a time t1 + t2 +... The relay memorises the total, cumulative opening time of control contact C and, once the set time T is reached, the output R reverts to its initial state. T = t1 + t2 +... 16

Legend Relay de-energised Relay energised Output open Output closed C Control contact G Gate R Relay or solid state output R1/R2 2 timed outputs R2 inst.the second output is instantaneous if the right position is selected T Timing period Ta - Adjustable On-delay Tr - Adjustable Off-delay U Supply 17