BUILDING & SAFETY DIVISION 110 E. LA HABRA BLVD. LA HABRA, CA Rev. 06/17

Similar documents
TYPICAL PATIO COVERS. OWNER: ADDRESS: PHONE:

APPLICATION FOR A BUILDING PERMIT

Estimated Cost of Project Contractor License No. Contractor Qualifier No.

Single-Family Dwelling Submittal Requirements

Typical Deck Details Based on the City of Nixa Residential Deck Ordinance

When is a Building Permit Required? Deck Details: What Must be Submitted with a Building Permit Application?

24" max from each end of the ledger. See detail 6A & 6B, typ. both ends IRC R Ledger R507.2

Attached/Detached Patio Cover

Lateral Support. Decks over 24 above grade require lateral support* *Exceptions to be discussed later

BUILDING PLANS. BUILDING INSPECTIONS DEPARTMENT

BUILDING PLANS. BUILDING DEPARTMENT

A. Rough carpentry includes but is not limited to the following:

Typical Deck Details

Typical Deck Details

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

Deck Design Guide. One and Two Family Residential Dwellings

FREDERICK COUNTY USBC/IRC 2015

Deck Evaluation Checklist

What Plans Do I Need for a Building Permit?

ONE AND TWO FAMILY DWELLINGS Uncovered Decks July, 2007

ROOF-CEILING CONSTRUCTION

CITY OF LOVELAND HOMEOWNERS GUIDE FOR BUILDING PERMITS FOR HOME IMPROVEMENTS

10x12 FOUNDATION GUIDE 10x12 TRICO AND FLORA SHEDS

Garage Design Guide. October 2018

DECK PERMIT APPLICATION PACKET

PV System Structural Criteria

10x10 Shed Plans and Building Guide

Structural Criteria for Residential Rooftop Solar Energy Installations

Structural Criteria for Residential Rooftop Solar Energy Installations

Structural Criteria for Residential Flush-Mounted Solar Arrays

12x12 Shed Plans and Building Guide

3.1 General Provisions

City of Virginia Beach, Virginia Typical Deck Details

DECKS. Stairway illumination Positive attachment of ledger Lateral load connection required board (R507.2) required (R ) (R311.7.

8x8 Shed Plans and Building Guide

3. Are component and cladding design pressures consistent with ASCE 7 for the wind speed and exposure category (ASCE 7 Fig. 6-3)?

2x6. 2x8. 2x10. Size. 2-2x10 8'-5" w/ 2 NJ 7'-3" w/ 2 NJ

City of Long Beach Department of Development Services Building and Safety Bureau. Wood Frame Prescriptive Provisions For Residential Construction

ROOF-CEILING CONSTRUCTION

TO WHOM IT MAY CONCERN:

IRC 2012 Code Compliant Wood Framed Residential details. Miss Installed Connectors with code references and remedies, discussion.

Sections & Details VOCABULARY

ROOF-CEILING CONSTRUCTION

6x6 Shed Plans and Building Guide

Introducing AJSTM INSTALLATION GUIDE USA. 8 th Edition USA

Fastener Schedule. a, b, c. FASTENER Roof 3-8d (2 1 / ) / ) 3-10d. 3-10d ( ) 3-16d box nails. (3 1 2 toe nails on one side

24 X32 3 CAR GARAGE POLE BARN STYLE FRAME

ROOF-CEILING CONSTRUCTION

SECTION ROUGH CARPENTRY

Pulaski County, Virginia Typical Deck Details Based on the 2012 Virginia Residential Code

SECTION ROUGH CARPENTRY 1.1 DESCRIPTION OF WORK:

SECTION ROUGH CARPENTRY

City of Lompoc Building & Safety Services Section 100 Civic Center Plaza Lompoc, CA Phone: Fax:

APA Performance Rated Rim Boards

Residential Decks. Typical Deck Details DECKING REQUIREMENTS

FASTENERS BUILDING DEPARTMENT

Featuring TJ Rim Board and TimberStrand LSL

Typical Deck Details

ESR-1254 * DELETED BY CITY OF LOS ANGELES. Reissued April 1, 2006 This report is subject to re-examination in one year.

Attachment of Residential Deck Ledger to Side of Metal Plate Connected Wood Truss Floor Ladder. Installation Instructions Revised 9/2/2016

How to Build Good Decks..

RESIDENTIAL BUILDING PERMIT REQUIREMENTS

VERSA-LAM BCI INSTALLATION GUIDE LIMIT STATES DESIGN CANADA

DOCUMENT SUBMITTAL REQUIREMENTS FOR AN ALTERATION OR ADDITION TO AN EXISTING SINGLE-FAMILY DWELLING OR MULTI-FAMILY DWELLING

SECTION: 15 ZONING RULE LOT AREA 6134 S.F S.F. BUILDING AREA (FOOTPRINT) LOT COVERAGE 20.2% 24.86' FRONT YARD SIDE YARD 8.

THE ENGINEERED WOOD ASSOCIATION

PRESCRIPTIVE RESIDENTIAL DECK CONSTRUCTION GUIDE. Based on the 2015 International Residential Code

A GUIDE TO APPLYING FOR A BUILDING PERMIT FOR A DETACHED GARAGE OR ACCESSORY BUILDING

Maryland Building Officials Association Typical Deck Details

ROOFING City of Grand Rapids Building Safety Division

Main Floor Revisions: 38' 0" Rm1 H3 50' 0" Bk1 B1 Rm2 B5 (26)-2 H2 B2 H3 (3)-3 B3 (11)-4 Bk1 B1 (5)-5 Rm4 Bk1 Rm3 Bk1 24' 0" 6' 0" 20' 0" START FRAMIN

ROOF-CEILING CONSTRUCTION

DOCUMENT SUBMITTAL REQUIREMENTS FOR A NEW SINGLE-FAMILY DWELLING


STORAGE SHED. Storage Shed SOUTHERN FOREST PRODUCTS ASSOCIATION SOUTHEASTERN LUMBER MANUFACTURERS ASSOCIATION

Load Tables, Technical Data and Installation Instructions

Double Beam Freestanding Pergola Installation Guide

IRC 2015 Code Compliant Wood Framed Residential Details. Incorrect Installations of Connectors with code references and remedies, discussion.

Re-Roofing Policy SPECIAL REQUIREMENTS AND NOTES

Prescriptive Residential Wood Deck Construction Guide Based on the 2006 International Residential Code

3 Basic Code Enforcement, Part 3

E-Blueprints. Children s Backyard Playhouse 8 x sq. feet main 32 sq feet porch 2 x 4 Framed Walls 6' Ceiling Height

SECTION ROUGH CARPENTRY

HOW TO BUILD A 12X8 SHED

With Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e H O W B U I L D S H E D.

Accessory Dwelling Unit Prototype 4 Plan Sets. Prototype 4: Detached 1- Story ADU using alternate materials and techniques

Exterior Wall Fastener Schedule

Collins Engineers Palmetto Islands County Park Boardwalk Repairs 03/28/2014 SECTION ROUGH CARPENTRY

ICC-ES Evaluation Report Reissued June 1, 2010 This report is subject to re-examination in one year.

Vertical Offset Base and Safety Rail System Installation Instructions

Beam & Header Technical Guide. LP SolidStart LVL. 2900F b -2.0E. U.S. Technical Guide U.S. TECHNICAL GUIDE

ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013.

DOCUMENT SUBMITTAL REQUIREMENTS FOR A NEW MULTI-FAMILY DWELLING

With Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e Download 12,000 More Shed Plans

Pryda Timber Connectors

Joint Evaluation Report

Ohlson Project Property Owner: Kathy Ohlson Property Address: Deer Lake Rd. Derwood MD 20855

LAS VEGAS PATIO COVER INSTALLATION INTSRUCTIONS

Pergola Installation Guide

installation care & maintenance instructions lifecycledecking.com 25-year limited residential warranty 20-year limited commercial warranty

Transcription:

STANDARD OPEN PATIO COVER (PLEASE NOTE: These are general guidelines, not to be used in lieu of actual code requirements for final design. Your final design will be subject to plan review.) BUILDING & SAFETY DIVISION 110 E. LA HABRA BLVD. LA HABRA, CA 90631 62-383-116 www.lahabracity.com Rev. 06/17

The Building and Safety Division s counter hours are Monday Friday, 7:30 a.m. 1:00 p.m. and by appointment only from 1:00 p.m. :00 p.m. Closed on alternate Fridays. The staff includes: Chief Building Official Dennis McCreary 62-383-119 Senior Building Inspector Ron Shanks 62-383-120 Senior Permit Clerk Nayaly Casillas 62-383-117 Permit Clerk Lauren Davis 62-383-118 Prior to the submittal of building plans for plan check review, verify all usable yard area and setback requirements. Do so by submitting a scaled plot plan, to be reviewed by the Planning Division over the counter, showing the proposed location of your patio addition and yard dimensions including setbacks from property lines and adjacent walls. Plan check review for patio covers is normally done over the counter. Please provide three sets of plans for review and approval. Plan check fees and permit fees are based on the job valuation (there is a minimum job valuation based on the square footage). For an estimate on fees, please contact the permit clerks. Be prepared to give the square footage of your addition. Owner builders shall submit an Owner Builder Declaration Form at the time of permit issuance. This form and the permit application can be downloaded from our website: www.lahabracity.com ALLOWABLE WORKING HOURS FOR CONSTRUCTION ACTIVITY La Habra Municipal Code Section 9.32.070 limits construction noise to the following days and hours: 7:00 a.m. to 8:00 p.m., Monday through Saturday All construction activities are prohibited on Sundays and City observed Federal holidays. Those holidays include: New Year s Day, President s Day, Memorial Day, Independence Day, Labor Day, Veteran s Day, Thanksgiving Day and Christmas Day. Construction noise regulations also apply to site improvement activity, building construction, trucks, vehicles, and equipment that are making deliveries, loading or transferring materials, equipment service and maintenance of any devices or appurtenances at or adjacent to any construction project. The City of La Habra will aggressively enforce these noise control measures. Violators may be issued citations. All persons involved with your project should be advised of these regulations. Questions regarding construction hours should be directed to the Building and Safety Division at (62) 383-116.

PLEASE NOTE: This information Bulletin is made available to assist you in preparing for obtaining permits. These are general guidelines, not to be used in lieu of actual code requirements for final design. Your final design will be subject to plan review. DEFINITION Patio covers are one-story, roofed structures not more than 12 feet above grade and used only for recreational or outdoor living purposes, not as carports, garages, storage rooms, or habitable rooms. Patio covers must be open on two or more sides for not less than 6% of the wall area below a minimum of 6 8 of each open wall, measured from the floor. The open sides must not be covered with any permanent materials which obstruct the free passage of light and air, except insect screening, or approved, translucent or transparent plastic, not more than.12 inch (3.2 mm), in thickness, glass conforming to the provisions of chapter 2 (tempered) or any combination of these. If two sides are open, the open sides may be partially enclosed by solid walls which do not exceed 30 inches in height above the floor, in addition to the screening (see drawings in this information bulletin). When required windows from adjoining rooms open into a patio cover, however, open area equivalent to the requirements of Appendix H, Section 102 of the California Residential Code apply. Patio covers may be attached or detached, and permitted only as accessory to single-family dwellings or to individual dwelling units in multi-dwelling-unit buildings. Patio covers cannot be used as carports, garages, habitable rooms or storage structures. Detached patio covers must be located a minimum of 10 from any other structure. Other provisions of the zoning code relating to minimum open areas and separation from the property line may apply. Please contact the Planning and Building & Safety Divisions for details related to your specific site plan. CONCRETE MIX The concrete mix for footings must meet the strength of Fc = 2000 psi minimum, or the following: 1 part Portland cement 2 ½ parts sand 3 ½ parts ¾ inch maximum size gravel Not more than 7 gallons of water per sack of cement. LUMBER Lumber shall be Douglas Fir / Larch No. 2 or better. All lumber must be grade marked. POST ANCHORAGE AND BRACING Posts must be anchored at the lower end and by any of the methods noted. They must be braced to the upper end using any of the optional methods shown. Manufacturer s installation instructions must be followed for installation of all connector and anchorage hardware. Decorative-type bracing may be substituted for the above if the same amount of structural bracing is realized. When the load on any single supporting post does not exceed 70 pounds per post, a minimum 3 ½ thick concrete slab on grade may be substituted for the pad footings shown on the typical framing details: Post anchorage to slabs must be the same as to footings. All fasteners (nails, screws, bolts) exposed to the elements are required to be corrosion resistant. LEDGER TO HOUSE ATTACHMENT When it is desired to connect and support one side of the structure by attaching it directly to the house, the rafter spans and main beam sizes will be as shown in the table. However, the main beam may be replaced on the side attached to the house with a ledger the same size as the rafters and fastened to the studs with 3/8 X corrosion resistant lag screws with washers, spaced at 16 on-center. Attachment to existing house rafters is achieved with optional method shown (See Details A & B of Sheet ). ROOF COVERING If covered with nominal half-inch exterior roof sheathing, the roof must have rafters spaced not more than 2 center to center. Maximum spacing for rafters supporting plywood decks shall be in accordance with spans shown on the structural panel. When used, plastic roof coverings must be installed according to manufacturer s recommendations and the corrugations should be placed perpendicular to and across the supports. All roof coverings (including plastic) must be minimum class B rated for flame spread. Roof slope must be specified on plans. Roof Live Load = 10 psf, minimum. Roof Dead Load = 7 psf, minimum, or actual weight of materials. NOTE: BUILDERS OF STEEL AND ALUMINUM PATIO COVERS, THE CITY OF LA HABRA REQUIRES TRACK AND LEDGER INSPECTIONS. 1

DIRECTIONS 1. Do not use pencil or red ink. 2. If framing plan is different from shown in this form, use an additional page (or pages) to show the framing plan. 3. Submit the following: a. Three copies of the site plan b. Three copies of this form. Complete both sides. c. Building permit application form. ***NOT TO SCALE*** GUIDELINES FOR PATIO CONSTRUCTION (Choose one that best fits your condition) Single Family Zero Lot Line Condominium* Town House* *REQUIRES HOA APPROVAL Beam Span Table A Beam Span Table A Rafter Spacing Table B D C & D A & B Rafter Span Table B SECTION Beam Ledger Beam Rafter Post 6 8 Min A, B & C Existing House FRAMING PLAN PATIO COVER REQUIREMENTS 1. Beam: Beam shall be Single Beach Double Beam 2. Rafter: Rafter shall be X at on center. Single Rafter Double Rafter 3. Roof Sheathing: Sheathing shall be self spaced.. Ledger: Ledged shall be a X mounted on existing wall with 3/8 x lag bolts at 16 on center. (See detail A of sheet ).. Fascia: Existing fascia, if used as a ledger, must be attached to the existing rafters with metal framing anchors on each side of each rafter. (See detail B of sheet ). 2

Table A MINIMUM HEADER SIZES Rafter POST SPACING (SEE FRAMING PLAN) Span 6'-0" 8'-0" 10'-0" 12'-0" 1'-0" 16'-0" 18'-0" 20'-0" '-0" "X" "X6" "X6" "X6" "x8" "x8" "x8" "x10" 6'-0" "X" "X6" "X6" "X6" "x8" "x8" "x10" "x10" 8'-0" "X" "X6" "X6" "X6" "x8" "x10" "x10" "x12" 10'-0" "X6" "X6" "x8" "x8" "x8" "x10" "x10" "x12" 12'-0" "X6" "X6" "x8" "x8" "x10" "x10" "x12" "x12" 1'-0" "X8" "x8" "x8" "x10" "x10" "x10" "x12" "x1" 16'-0" "x8" "x8" "x10" "x10" "x10" "x10" "x12" "x1" 18'-0" "x10" "x10" "x10" "x10" "x12" "x12" "x1" "x1" 20'-0" "x10" "x10" "x12" "x12" "x12" "x12" "x1" "x1" Table B MINIMUM RAFTER SIZES Rafter RAFTER SPACING (Center to Center) Span 12" 16" 2" 32" 6'-0" 2"x" 2"x" 2"x" 2"x" 7'-0" 2"x" 2"x" 2"x" 2"x" 8'-0" 2"x" 2"x" 2"x" 2"x" 9'-0" 2"x" 2"x" 2"x" 2"x" 10'-0" 2"x" 2"x" 2"x" 2"x6" 11'-0" 2"x" 2"x" 2"x6" 2"x6" 12'-0" 2"x" 2"x6" 2"x6" 2"x6" 13'-0" 2"x6" 2"x6" 2"x6" 2"x6" 1'-0" 2"x6" 2"x6" 2"x6" 2"x8" 1'-0" 2"x6" 2"x6" 2"x6" 2"x8" 16'-0" 2"x6" 2"x6" 2"x8" 2"x8" 17'-0" 2"x6" 2"x6" 2"x8" 2"x8" 18'-0" 2"x6" 2"x6" 2"x8" 2"x10" 19'-0" 2"x8" 2"x8" 2"x8" 2"x10" 20'-0" 2"x8" 2"x8" 2"x8" 2"x10" NOTES: *After prolonged periods of time 2 rafters spanning more than 8 feet, minimum, deflect permanently and give an objectionable appearance. It is, therefore, recommended that for rafter spans exceeding 8 feet, a minimum rafter size of 2 x 6 be used. Table C MINIMUM SQUARE FOOTING SIZES Post RAFTER SPAN (SEE CROSS SECTION) Spacing 6'-0" 8'-0" 10'-0" 12'-0" 1'-0" 16'-0" 18'-0" 20'-0" '-0" 12" sq 12" sq 12" sq 12" sq 12" sq 12" sq 1" sq 1" sq 6'-0" 12" sq 12" sq 1" sq 1" sq 1" sq 16" sq 16" sq 16" sq 8'-0" 1"sq 1"sq 1"sq 16" sq 16" sq 18" sq 18" sq 20" sq 10'-0" 1"sq 16" sq 16" sq 18" sq 18" sq 20" sq 20" sq 22" sq 12'-0" 16" sq 16" sq 18" sq 20" sq 20" sq 22" sq 22" sq 2" sq 1'-0" 16" sq 18" sq 20" sq 20" sq 22" sq 22" sq 2" sq 2" sq 16'-0" 18" sq 20" sq 20" sq 22" sq 2" sq 2" sq 27" sq 27" sq 18'-0" 20" sq 20" sq 22" sq 2" sq 2" sq 27" sq 27" sq 30" sq 20'-0" 20" sq 22" sq 2" sq 2" sq 27" sq 27" sq 30" sq 30" sq Table D1 Roof Sheathing Plywood Min. 1/32" CDX Table D2 Lattice 2"x2" Self Spaced Spans 2"x" Self Spaced Spans On Edge 6'-0" 11'-0" 3

X Post X Post (Not naturally durable or pressure treated.) Adjustable Post Base (AB ) 8 Minimum or Naturally durable species or pressure treated. Minimum 3 ½ Concrete Slab Adjustable Post Base (CB ) 1 Minimum Standoff - Per manufacturer s instructions dry pack with concrete after post installation. MIN. Wedge anchor, epoxy anchors, or other approved devices 8 Min. A SLAB FOOTING Min. 6 mil. (.006 inch) polyethylene sheeting, impervious moisture barrier. 12 Min. 12 Min. Table C ***NOT TO SCALE*** B PAD FOOTING x Post Column Base (CB ) W/ 2-/8 Dia. Machine Bolts Roof Sheathing See Table D: Pre-Fab Pier or Cast in place Concrete Pier 2 X Rafter See Table B 8 Min. All fasteners to be corrosion resistant. 16 Min. Header See Table A T-Strap (or Strap Tie) W/ 6-1/2 Dia. Machine Bolts. 16 Square Minimum L- Strap (OL Strap Tie) W/ ½ Dia. Machine Bolts, through bolted, with nuts and washers as required for the bolt sizes. C PIER FOOTING D HEADER: ELEVATION

***NOT TO SCALE*** Corrosion Resistant Fasteners Roof Sheathing See Table D Exterior Stud Wall Exterior Stucco 16 Max. 3/8 X Corrosion Resistant Lag Bolt @ 16 o.c. FACE 16 Max. 1 Minimum 2 X Ledger, minimum width to match rafters. SECTION Existing Residence Roof Overhang A LEDGER DETAIL A3 on Each Side of each rafter Roof Sheathing See Table D NOTE: 1. Standard Joist Hanger ***All existing structural lumber used to support the new patio cover must be structurally sound (i.e. without termite damage, dry rot, or other decay).. Existing 2 X Fascia 2 X Ledger See Note 1 ½ Dia Machine Bolt @ 16 o.c. Rafter See Table B B EAVE CONNECTION SECTION

***NOT TO SCALE*** X Post Roof Sheathing See Table D Continuous 2 X Blocking W/16d nails @ 8 o.c. Alternate A3 @ 2 o.c. Double 2 X Rafter See Table B 2 ½ X 6 Machine Bolts with Flat Washers Each Side Header See See Table A Post Cap (PC ) For x 2 X Rafter See Table B X Post X Post C HEADER DETAIL D HEADER DETAIL PLEASE PROVIDE THREE SETS OF PLANS (SITE PLAN AND CONSTRUCTION DETAILS) FOR REVIEW AND APPROVAL. Patio Enclosure Requirements Three sets of site plans with construction details required for review by Planning and Building & Safety Departments. CRC Appendix H. Enclosure walls are permitted to be any configuration, provided the open or glazed area of the longer wall and one additional wall is equal to at least 6% of the area below a minimum of 6 8 of each wall, measured from the floor. Exterior openings required for light and ventilation shall be permitted to open into a patio structure conforming to Section AH101, provided that the patio structure shall be unenclosed if such openings are serving as emergency egress or rescue openings from sleeping rooms. Where such exterior openings serve as an exit from the dwelling unit, the patio structure, unless unenclosed, shall be provided with exits conforming to the provisions of Section R311 of this code 6

INSTRUCTIONS 1. Show project address, owners name, north arrow and scale 2. Show accurate footprint of all existing and proposed structures Owner: Address: City: State: Zip: 3. Show driveway. Show all property lines (P.L.), label each and properly dimension. Show dimensions of proposed structures(s) 6. Show setbacks from property lines to proposed structure(s) Notes: 1. Have correct legal description and address of property. 2. Note adjoining streets or alleys and width of curb cuts. 3. Note location of each auto parking spaces.. North arrows should be correctly placed.. Draw completely dimensioned lot plan. 7