White Paper: Modifying Laser Beams No Way Around It, So Here s How

Similar documents
How to Avoid Thermal Sensor Damage & Out of Tolerance Conditions

Coherent Laser Measurement and Control Beam Diagnostics

How to Properly Select a Laser Power or Energy Sensor

Beam Shaping and Simultaneous Exposure by Diffractive Optical Element in Laser Plastic Welding

Novel laser power sensor improves process control

Supplementary Materials

ADVANCED OPTICS LAB -ECEN 5606

Laser Beam Analysis Using Image Processing

Properties of Structured Light

NanoScan 2s Standard Version Scanning Slit Beam Profiler For High Accuracy Dimensional Measurement

Beam Analysis NanoScan 2. Scanning Slit Beam Profiler For High Accuracy Dimensional Measurement. Capabilities.

Beam Profiling. Introduction. What is Beam Profiling? by Michael Scaggs. Haas Laser Technologies, Inc.

Real-Time Scanning Goniometric Radiometer for Rapid Characterization of Laser Diodes and VCSELs

Optical Components for Laser Applications. Günter Toesko - Laserseminar BLZ im Dezember

Laser Telemetric System (Metrology)

Beam Analysis BeamWatch Non-contact, Focus Spot Size and Position monitor for high power YAG, Diode and Fiber lasers. Disruptive Technology

Diffuser / Homogenizer - diffractive optics

AgilOptics mirrors increase coupling efficiency into a 4 µm diameter fiber by 750%.

ADVANCED OPTICS LAB -ECEN Basic Skills Lab

Information & Instructions

Vixar High Power Array Technology

DEVELOPMENT OF CW AND Q-SWITCHED DIODE PUMPED ND: YVO 4 LASER

Criteria for Optical Systems: Optical Path Difference How do we determine the quality of a lens system? Several criteria used in optical design

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

Optical Isolator Tutorial (Page 1 of 2) νlh, where ν, L, and H are as defined below. ν: the Verdet Constant, a property of the

3.4 Introduction to Scanning-Slit Profilers

3.4 Introduction to Scanning-Slit Profilers

Ultra-stable flashlamp-pumped laser *

Laser Speckle Reducer LSR-3000 Series

End Capped High Power Assemblies

An Optical Characteristic Testing System for the Infrared Fiber in a Transmission Bandwidth 9-11μm

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science

Nmark AGV-HPO. High Accuracy, Open Frame, Thermally Stable Galvo Scanner. Highest accuracy scanner available attains singledigit,

ADALAM Sensor based adaptive laser micromachining using ultrashort pulse lasers for zero-failure manufacturing D2.2. Ger Folkersma (Demcon)

BEAMAGE-3.0 KEY FEATURES BEAM DIAGNOSTICS AVAILABLE MODELS MAIN FUNCTIONS SEE ALSO ACCESSORIES. CMOS Beam Profiling Cameras

ERS KEY FEATURES BEAM DIAGNOSTICS MAIN FUNCTIONS AVAILABLE MODEL. CMOS Beam Profiling Camera. 1 USB 3.0 for the Fastest Transfer Rates

EE119 Introduction to Optical Engineering Spring 2003 Final Exam. Name:

REAL TIME THICKNESS MEASUREMENT OF A MOVING WIRE

Optical Components - Scanning Lenses

Improved Radiometry for LED Arrays

Fiber Optic Communications

CONFOCAL MICROSCOPE CM-1

WJM Technologies excellence in material joining

Design Description Document

3.0 Alignment Equipment and Diagnostic Tools:

arxiv:physics/ v1 [physics.optics] 12 May 2006

Assembly and Experimental Characterization of Fiber Collimators for Low Loss Coupling

Sensor Fusion Enables Comprehensive Analysis of Laser Processing in Additive Manufacturing

Lithography. 3 rd. lecture: introduction. Prof. Yosi Shacham-Diamand. Fall 2004

Sintec Optronics Technology Pte Ltd 10 Bukit Batok Crescent #07-02 The Spire Singapore Tel: Fax:

Beamscope-P8 Wavelength Range. Resolution ¼ - 45 ¼ - 45

Twin hexapod operated beam expander and dual pyrocam measurement for laser beam path optimization

Will contain image distance after raytrace Will contain image height after raytrace

Laser and LED retina hazard assessment with an eye simulator. Arie Amitzi and Menachem Margaliot Soreq NRC Yavne 81800, Israel

Current Technology of Laser Beam Profile Measurements

Optical Coherence: Recreation of the Experiment of Thompson and Wolf

Angular Drift of CrystalTech (1064nm, 80MHz) AOMs due to Thermal Transients. Alex Piggott

SURFACE ANALYSIS STUDY OF LASER MARKING OF ALUMINUM

Observational Astronomy

Nmark AGV-HP. High Accuracy, Thermally Stable Galvo Scanner

R. J. Jones Optical Sciences OPTI 511L Fall 2017

A Possible Design of Large Angle Beamstrahlung Detector for CESR

Wavelength Stabilization of HPDL Array Fast-Axis Collimation Optic with integrated VHG

880 Quantum Electronics Optional Lab Construct A Pulsed Dye Laser

Open Access Structural Parameters Optimum Design of the New Type of Optical Aiming

Silicon Photodiodes - SXUV Series with Platinum Silicide Front Entrance Windows

Radial Polarization Converter With LC Driver USER MANUAL

Power Sensors Introduction

High power VCSEL array pumped Q-switched Nd:YAG lasers

Industrial quality control HASO for ensuring the quality of NIR optical components

Applications of Optics

Akinori Mitani and Geoff Weiner BGGN 266 Spring 2013 Non-linear optics final report. Introduction and Background

SECOND HARMONIC GENERATION AND Q-SWITCHING

Generation of a Line Focus for Material Processing from an Array of High Power Diode Laser Bars R. Baettig, N. Lichtenstein, R. Brunner, J.

ENSC 470/894 Lab 3 Version 6.0 (Nov. 19, 2015)

LaserBeam ProfilingSolutions. IRLaserBeam Profiler

Pixel-remapping waveguide addition to an internally sensed optical phased array

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

Parallel Mode Confocal System for Wafer Bump Inspection

APPLICATIONS FOR TELECENTRIC LIGHTING

User s Guide Modulator Alignment Procedure

Keysight Technologies Optical Power Meter Head Special Calibrations. Brochure

Office europeen des Publication number : EUROPEAN PATENT APPLICATION

BEAMAGE KEY FEATURES AVAILABLE MODELS. CMOS Beam Profiling Cameras

Measuring Procedure the Principle. The laser beam is scanned by means of a specialized measuring tip within a 3D measurement cylinder.

Optoliner NV. Calibration Standard for Sighting & Imaging Devices West San Bernardino Road West Covina, California 91790

Kit for building your own THz Time-Domain Spectrometer

LTE. Tester of laser range finders. Integrator Target slider. Transmitter channel. Receiver channel. Target slider Attenuator 2

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION

Titelfoto. Advanced Laser Beam Shaping - for Optimized Process Results and Quality Inspection in the PV Production - Maja Thies.

Single Photon Interference Laboratory

Mode analysis of Oxide-Confined VCSELs using near-far field approaches

SNP High Performances IR Microchip Series

plasmonic nanoblock pair

Comparison of FRD (Focal Ratio Degradation) for Optical Fibres with Different Core Sizes By Neil Barrie

Experiment 1: Fraunhofer Diffraction of Light by a Single Slit

Astronomical Cameras

Improving efficiency of CO 2

Photolithography II ( Part 2 )

Reflectors vs. Refractors

Transcription:

White Paper: Modifying Laser Beams No Way Around It, So Here s How By John McCauley, Product Specialist, Ophir Photonics There are many applications for lasers in the world today with even more on the horizon. In order to apply a laser to an industrial process, medical therapy or communications technology, it is usually necessary to modify the laser beam to achieve the desired results. Laser beam measurement tools make this possible. In this article we will discuss how to match an appropriate laser beam profiling technique to a laser application. The topics will include building an aligned optical system, collimation and focusing, high power laser quality measurements, and proper attenuation techniques for making accurate laser measurements. Building an Aligned Optical System Many laser applications are based on a system that includes a laser with associated optics to deliver a laser beam of known size and position to do something. Examples of these are as diverse as laser printers and marking machines, laser range finder, LIDAR or military targeting systems, and laser projection systems for movie theatres. What all of these have in common is the need to put a beam of a certain size at a certain place in space. Using a beam profiler allows this to be done quickly and efficiently simply place the profiler where the beam is to be aimed and measure the size and position. These parameters can be adjusted with direct feedback from the profiler. Beam profilers to do this can be either based on CCD or CMOS array or scanning slit technology. Each has its advantages. Arrays will provide a true two dimensional image of the beam and show any irregularities in power distribution; scanning slits will provide an XY profile, but can measure much smaller beams, as small as 10µm, and will require little or no attenuation or adjustment to the profiler itself. In addition, the scan plane of the slit profiler is very well known, allowing the z-location of a beam waist to be located very accurately. Both camera and slit profilers can determine the x-y position of the beam in space to less than a µm.

Fig 1. Scanning slit and array profilers. For applications where pointing accuracy is very important it is necessary to isolate linear and angular pointing error and also to eliminate external influences on the measurement. Pointing accuracy is dependent on the profiler, the fixturing of the laser system and external influences. Localized heating, air currents, vibration all contribute to uncertainty in pointing measurements. One way to isolate external influences is to shrink the measurement to as short a distance as possible. Rather than measuring pointing over a distance of 10s of meters, using a very accurate profiler on the bench top can deliver better results. By using scan averaging with a NanoScan slit scanning profiler it is possible to measure pointing accuracy to submicron precision, allowing a range finder to be aligned in a very small test fixture. Isolating linear from angular pointing error can be done with a two profiler method. By splitting the beam and looking at the near-field and far-field through an f-theta lens these motions can be separated. Angular motion will show up as a shift in the near-field measurement, but will not be seen in the far-field due to the f-theta correction. Linear motion, on the other hand will be seen in the far-field as a shift in position on the far-field profiler.

Fig 2. Angular vs linear pointing measurement set up. This may be more than most applications need, and simply placing the profiler where the beam is to be delivered is usually enough. Collimation and Focusing Other applications often require that a laser either be focused to a particular beam waist or collimated to a minimally diverging or converging beam. Focusing can be a fairly simple process for low power beams, such as those used in fiber optic telecommunication or point-of-sale scanners. It is much more complicated for higher power applications like ophthalmic surgery, medical therapeutics or precision welding. For a low power application, one can simply place the profiler at the focus point and adjust the optics until the desired beam size if obtained. This is routinely done with passive optical components for free space coupling of fiber. Fig 3. Focusing fiber optic components. Measuring a higher power focused beam can be much more difficult because the power density of the laser increases geometrically as beam size shrinks. Although the slit scanner can often handle direct measurement of fairly high

power beams, often the power density can exceed the damage threshold for the slit material. Camera measurement of focused beams is always a bit more complicated, because arrays always need attenuation to measure lasers without saturating the signal. With a focused beam it is usually impossible to get the focused beam to the array through attenuators without distortion. Fig 4. Focused beam has different path lengths through attenuator. The attenuation in Fig. 4 is much simpler than is normally used and it would still cause distortion. The solution to this problem is to image the beam waist with a lens, with the attenuation added to the image. Fig 5. Focused spot profiler.

This method can also be used with a scanning slit profiler to reduce the power density of the beam, again geometrically. For example if one has a 15W laser beam that is focused to 10µm, the power density would exceed the damage threshold of the slit material. However, by expanding the beam 10X, the power density will be reduced by 100-fold, bringing it back to the safe level. Fig 6. Beam expander with slit profiler. Collimation Collimation is the opposite of focusing, that is, it is the process of making the laser have the same diameter for as long a distance as possible. Laser applications that need this type of adjustment include laser point-of-sale scanners, LIDAR and rangefinders, guide stars and free-space optical communications; basically anything that needs a beam that maintains a uniform beam size over a long distance. Another application is the collimation of a large beam that will then be focused to a small diameter. There are actually two types of collimation; one can be described as the minimum divergence, and the other as the maximum distance to the waist. When collimating for minimum divergence, the following formula defines the divergence angle, θ = Dƒ / ƒ, using a lens of known focal length. By placing a beam profiler at the geometric focus of the lens, adjusting the collimation to produce the minimum spot size at this point achieves the best collimation. This type of collimation is important for situations where the mathematically accurate value for θ is important, such as when creating a collimated beam to be refocused to a specific size and Rayleigh range. In many cases, simply adjusting for the maximum distance to the waist, or focusing to infinity, is sufficient to provide the performance required.

Fig. 7. Lens collimation method. It is also possible to use the above divergence measurement technique to achieve the divergence that will provide the proper distance-to-the-waist desired. There is a more thorough discussion of collimation of Gaussian beams in Donald O Shea s Elements of Modern Optical Design. 1 High Power Beam Quality Measurements High power lasers are used for many industrial applications, particularly high precision welding, brazing and cutting operations. The laser is well suited to these operations and can be a rapid and efficient method, but only if the laser is operation properly and delivering the correct beam shape and power to the work piece. In order to guarantee this, there are several things that can and should be measured periodically. Output power or energy Spatial or Beam Profile Waist position Temporal profile (for pulsed beams) All of these beam quality parameters can affect the performance of the laser in accomplishing its assigned task. Measurements should be made in order to establish the criteria of a laser process to ensure stable, reliable and consistent performance and to monitor this performance over time. Lasers and optical delivery systems degrade over time, and monitoring the laser criteria can help to prevent waste and rework if the laser performance no longer meets the requirements of the process. Measurements should be made whenever one is moving or expanding a process to another system, for batch validation and for laser maintenance and troubleshooting. Many 1 O Shea, Donald C., Elements of Modern Optical Design, John Wiley and Sons, 1985, pp. 241-5

organizations operating under ISO 9001, GMP or GLP protocols will mandate routine periodic measurement to ensure consistent and traceable results. The technologies available for laser measurement include power and energy meters, which indicate the total power or energy being delivered by the laser system; beam profilers, which show the shape and size of the beam; and fast photodiodes to measure the pulse shape of pulsed laser beams. Power and energy meters are available in many varieties, depending on the nature of the laser to be measured. Power meters are used for continuous wave (CW) lasers and energy meters are used for pulsed beams. For most industrial strength lasers these are either thermal sensors or pyroelectric sensors. Thermal sensors, which detect the temperature rise caused by the laser and convert it to an electrical signal, can be used to measure average power or single pulse energy up to kws or 100s of Joules. Depending on the power or energy levels that they are designed to handle, they will have convection, fans or water for cooling. For measuring repetitive pulse energies, pyroelectric sensors are used. These comprise a crystal lattice that expands and contracts in response to the laser pulses, creating a proportional electrical signal and can be used up to 20kHz repetition rates and 10s of Joules of energy. These are typically cooled by convection. Fig 8. Various power and energy sensors. Further information about the laser s performance is provided by beam profiling, as discussed above. However with high power lasers, beam profiling becomes more complicated due to the potential for damage to the profiler. Using attenuation devices, lasers can be sampled by camera based array profilers, which will provide measurement of beam size, shape, spatial energy distribution and beam wandering. Both array-based and scanning slit based profilers can be used to measure focused spots to ensure that the laser beam being delivered to the work piece is of the proper size to do the required job. Other types of profilers such as a rotating pinhole or a spinning wand

are able to sample a small portion of the beam and construct an image of the profile, beam caustic and energy distribution of the beam. Fig.9. High power monitoring setup. For pulsed beam measurement the temporal profile of the pulses can provide additional important information about the performance of the laser for a particular operation. Leading edge spikes can cause a laser to create uneven welds or ragged cuts. A fast photodiode can provide a good picture of the temporal profile to see if poor performance of the laser system is the result of irregular pulses, or some other cause. Proper Attenuation Design for Laser Measurement There are two basic types of attenuators used when making laser measurements, reflective and absorptive. Within these two categories there are different types and materials, but they effectively work in the same manner. Absorptive attenuators are the colored or gray-glass filters that work by absorbing some portion of the light, and they may be made of glass, plastic or Inconel. Because they absorb light, they are subject to heating, which then changes the optical properties of the material in a process called thermal lensing. The localized heating in the filter material forms a lens that can then modify the beam, causing erroneous profile information. Reflective attenuators, such as laser end mirrors, quartz wedges or prisms are not as susceptible to this phenomenon, and therefore should usually be used for the first stages of attenuation of any lasers with powers greater than 100mW per millimeter diameter, or 12.7W/cm 2. This happens fast, and may give the appearance of a stable laser profile. The following experiment shows this dramatically:

Experimental Design An unfocussed CW beam from a Coherent DPSS 532 Laser (532nm wavelength) with a nominal power of 500mW was measured using three methods. Method 1 Using the camera array beam profiler with all the attenuation provided by absorptive filters, the beam was measured at a point 30cm from the exit aperture of the laser. The attenuation comprised a 2.8OD gray-glass fixed filter and the Photon ATP-K continuously variable wedge attenuator (1.7 4.6OD). Method 2 The first stage of attenuation was provided by using a front surface reflection with additional attenuation provided by the ATP-K. The rest of the measurement set up remained identical to that in Method 1. Method 3 Measurements were then taken at the same measurement plane with the Photon NanoScan scanning slit profiler, which needed no attenuation for this laser power. Results and Discussion Because we expected to see thermal effects in the initial experimental design (Method 1), we used time charting to observe the measurement of the laser. In order to see any effects and eliminate any contribution from the laser itself, we started the camera and then uncovered the laser beam. There was an immediate spike of the beam size to around 700µm. It settled to a value around 500µm (1/e 2 ) within a few milliseconds. With each measurement we saw a similar pattern; however the value of the initial spike was somewhat variable.

Fig 10. Time chart of beam measurement made with absorptive attenuation only, showing initial spike of beam size with stabilization to lower value. Had time charting not been employed, the measurement would have appeared to be stable at the 400-500µm beam size. Fig 11. Data display of beam size measurements made with absorptive attenuation only. When this same experiment was repeated using the front surface reflection attenuator, the spiking effect was no longer visible and the beam measurement was ~850µm in one axis and 914µm in the other. Fig 12. Data display of camera beam size measurements with 4% front surface reflector and ATP-K. Measurement with the NanoScan showed a beam size measurement of ~850µm

Fig 13. Data display of beam size measurements made with NanoScan profiler. The measurements of the properly attenuated beam in the camera and the NanoScan were within 2% agreement, which is the specification for accuracy of these measurements. The beam measurements subject to thermal lensing were 30-40% low, indicating that a very rapid lensing effect was taking place in the first attenuator. Because this effect is so rapid, it is quite possible for such errors to go unnoticed. The measurements did not exhibit the blooming effect that might we expected from slower heating. Instead they achieved equilibrium within a matter of milliseconds. The power density of this laser beam was ~80W/cm 2. The power going into the ATP-K attenuator after the front surface reflector was 3.2W/cm 2, which is well below the theoretical thermal lensing limit of 12.7 W/ cm 2. The comparable results from this configuration and the NanoScan confirm that thermal lensing effects do not occur at when the beam power incident on the absorptive attenuator properly adjusted. Conclusion Matching your profiling technique to your laser application will allow you to monitor and adjust you laser system to meet the requirements of the job at hand. In many cases a laser profiler will make the process of building a laser system much more efficient and accurate.

----- Author Bio John McCauley joined Ophir-Spiricon in January 2009 and now serves as Product Specialist for the company s line of laser measurement systems. Prior to that, his background was as an end user of, and an Applications Engineer, working with laser marking and engraving systems. He has been involved with and helped with the instruction of several Laser Safety Officer, Laser Measurement, and Laser Application Technology courses. John also served in the US Navy as a nuclearqualified machinist mate on fast attack submarines out of Pearl Harbor Hawaii. He can be reached at john.mccauley@us.ophiropt.com Ophir Photonics http:// Copyright 2015, Ophir-Spiricon, LLC.