SECTION Display Case Door Series 1301-CM

Similar documents
SECTION FOLDING GLASS PANEL PARTITIONS

SECTION FRAMELESS GLASS SLIDING BI-FOLD SHOWER DOOR HARDWARE

MOVEABLE GLASS WALL TECHNICAL DATA

SECTION BULLET- RESISTANT DOORS

FUZION Fused Glass Countertops - Andrew Pearson Design

Guide Specification Section Interior Suspended Sliding Glass Doors

B. Bidders shall acknowledge receipt of this Addendum in writing on his Proposal Form.

Guide Specification Section Interior Aluminum Doors and Frames

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

Chevy Chase Club June 30, 2008 Bowie Gridley Architects

SECTION MANUFACTURED CASEWORK

Product Guide Specification

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS

Student Services & Classroom Addition

Toll-Free

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS

SECTION ARCHITECTURAL WOOD CASEWORK

SECTION INTERIOR SIGNAGE

Product Guide Specification

SCI-FAB Product Specifications. Casework Section 1. Part 1 General

SECTION WOOD DOORS

Solid Surface Countertops

Bovard Studios Inc. Section April 6, 2004 Page 1

b. B aluminum and aluminum-alloy extruded bar, rod, wire, shape and tube

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION HOLLOW METAL DOORS AND FRAMES

D. Product Certificates: Signed by manufacturers of casework certifying that products furnished comply with requirements.

SECTION PRE-MANUFACTURED CABINETS

PRODUCT DATA CATALOG

PROJECT LOCATION SECTION PREFINISHED STEEL DOOR FRAMES

SECTION 10520: FIRE EXTINGUISHERS AND CABINETS

Tufftec Lockers Specifications & Drawings SPECIFICATIONS & DRAWINGS

SECTION COUNTERTOPS ecox PART 1 GENERAL

B. Terracotta Precast Facade Assembly consisting of single-leaf, through body color terracotta clay tiles.

DIVISION 11 EQUIPMENT SECTION PHOTO DARKROOM FUME EXHAUST VENT-HOODS

1. Division 6 Section "Rough Carpentry" for furring, blocking, and other carpentry work that is not exposed to view.

SECTION WOOD ACCORDION FOLDING DOORS

SECTION SWINGING AUTOMATIC ENTRANCES IN-GROUND, AUTOMATIC SWING DOOR OPERATOR CONVERTER ADAPTED TO BROOKFIELD NB-500 EXTREME DUTY OPERATOR

Music Area Casework General 1.01 Summary Related Sections Definitions Qualifications and Quality Assurance

SECTION WOOD ARCHITECTURAL CABINETS AND QUARTZ COUNTERTOPS

ROWAN COUNTY AIRPORT APRIL 2017 TERMINAL EXPANSION

SECTION FINISH CARPENTRY PART 1 GENERAL. 1.1 SECTION INCLUDES A. Interior Finish Carpentry Work: 1. Refer to schedule at end of Section.

SECTION HOLLOW METAL DOORS AND FRAMES

GUIDELINE SPECIFICATIONS

Copyright 2017 AIA MasterSpec Premium 05/17 PRODUCT MASTERSPEC LICENSED BY ARCOM TO WEREVER PRODUCTS, INC.

Product Guide Specification For Nonrated & 20-Minute Rated Doors

INSTALLATION INSTRUCTIONS SIDELITE ASSEMBLY SERIES 900 TERRACE DOOR AND SERIES 925 PATIO DOOR

INTEX Millwork Solutions SECTION EXTERIOR PVC PERGOLAS (IBC Compliant)

Series 6000 Vinyl Single Hung

Solid Surface Fabrications

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).

AMBICO Limited Section and WOOD BULLET RESISTANT DOORS AND FRAMES Page 1

SECTION SWINGING AUTOMATIC ENTRANCES

C. HMMA 863: Guide Specifications for Detention Security Hollow Metal Doors and Frames

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION METAL FABRICATIONS

SECTION ELECTRICAL IDENTIFICATION

DETAILED STILE AND RAIL WOOD DOOR SPECIFICATION

C.R. LAURENCE CO. INC Installation Instructions

SECTION SHEET METAL FLASHING AND TRIM

A. It is preferred that all submittals to be submitted electronically in PDF format.

Series 6000 Vinyl Horizontal Slider

SECTION ARCHITECTURAL WOODWORK

A. Extent of structural precast concrete work is shown on drawings and in schedules.

SECTION ARCHITECTURAL WOODWORK

B. Section Rough Carpentry: Support framing, grounds, and concealed blocking.

SECTION SHEET METAL FLASHING AND TRIM

SECTION CUSTOM CABINETS

2.01 Standard Entrances Description

Ash Brook Golf Course Scotch Plains, New Jersey

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION METAL LOCKERS

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

Tender No Section St. James - Assiniboia Centennial Pool Fitness Facility Addition Page 1

Please read and understand all instructions before beginning. These instructions cover the non-impact aluminum French Door 101.

Design and Construction Standards SECTION ATHLETIC LOCKERS

PRODUCT DATA CATALOG

Series 9000 Vinyl Single Hung

SECTION INTERIOR ARCHITECTURAL WOODWORK. A. Section includes interior woodwork items indicated not specified elsewhere and as specified.

Product Guide Specification

SECTION INTERIOR ARCHITECTURAL WOODWORK

EXTERIOR PAINTING

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

Collins Engineers Palmetto Islands County Park Boardwalk Repairs 03/28/2014 SECTION ROUGH CARPENTRY

P O S T E R C A S E S D I S P L A Y C A S E S M E S S A G E B O A R D S E X H I B I T C A S E S D I R E C T O R I E S W W W. P O B L O C K I.

Product Guide Specification

CLEAR GLASS WALL SYSTEMS

Series 9000 Vinyl Horizontal Slider

1.1 SUMMARY. A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards.

EMMEGI ARCHITECTURAL FENCING MASTER SPECIFICATION SECTION METAL FENCING, GATES & RAILING SYSTEM PART 1 GENERAL

SECTION SIGNAGE

SECTION PLASTIC-LAMINATE-FACED ARCHITECTURAL CABINETS

SECTION CARPENTRY

STANDARD ENTRANCES TECHNICAL MANUAL

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

SECTION FINISH CARPENTRY

SECTION WOOD SHINGLES

SECTION ROOF ACCESSORIES. Display hidden notes to specifier. (Don't know how? Click Here)

Transcription:

1 SECTION 12 3559 Display Case Door Series 1301-CM PART 1 - GENERAL 1.01 SUMMARY A. This section includes: 1. Display Case Glass Doors. 2. Sidelites. B. Related work in other sections: 1. 08 8000- Glazing 2. 10 1200- Display Cases 3. 12 3500- Specialty Casework 1.02 SUBMITTALS A. Product Data: Submit Manufacturer s product data for Display Case Door Systems including: 1. Manufacturer s standard details and fabrication method. 2. Data on finishing, hardware and accessories. 3. Recommendations for maintenance and cleaning of finished surfaces. B. Shop drawings for each Display Case Door System are required, including: 1. Layout and installation details. 2. Elevations at 1/4-inch scale. 3. Anchorage and reinforcement. 4. Glazing details. C. Samples for approval: 1. Submit pairs of samples of each specified metal color and finish on 9-inch long sections of extrusions or formed shapes. 2. Submit samples of glass approximately 12 inches square showing the edge conditions. 1.03 QUALITY ASSURANCE A. Installer qualifications: Engage an experienced installer who has completed installations of Display Case Door Systems similar in design and extent to those required for the project and whose work has resulted in construction with a record of success in service performance. B. Manufacturer s qualifications: Provide Display Case Doors produced by a firm experienced in manufacturing Display Case Door Systems that are similar to those indicated for this project and that have a record of success in service performance.

2 C. Single source responsibility: Obtain Display Case Door Systems from a single manufacturer to ensure full compatibility and warranty of parts. D. Design criteria: The drawings indicate the size, profile and dimensional requirements of the Display Case Door System required and are based on the specific types and models indicated. Display Case Doors by other manufacturers may be considered, provided deviations in dimensions and profiles are minor and do not change the design concept as judged by the Architect. The burden of proof of equality is on the proposer. E. Safety glass standards: 1. Tempered glass components that comply with ANSI Z97.1 and testing requirements of CPSC 16 CFR 1201 Category II. Comply with ASTM C1048, Kind FT (fully tempered), Condition A (uncoated), Type I (transparent, flat), Class 1 (clear), Quality q3 glazing. 2. Laminated annealed glass that comply with ASTM C1172, ANSI Z97.1 and testing requirements of CPSC 16 CFR 1201 Category II. 1.04 DELIVERY, STORAGE, AND HANDLING A. Deliver all Display Case Door Systems and related components in the manufacturer s original protective packaging. Do not deliver door units until the work is ready for their installation. 1. Inspect components for damage upon delivery. Unless minor defects in metal components can be made to meet the Architect s specifications and satisfaction, damaged parts should be removed and replaced. 1.05 PROJECT CONDITIONS A. Field Measurements: Check opening by accurate field measurement before fabrication. Show recorder measurements on shop drawings. Coordinate fabrication schedule with construction progress to avoid delay of the work and possible damage to the finished product. 1. Where necessary, proceed with fabrication without measurement and coordinate fabrication tolerances to ensure proper fit. PART 2 - PRODUCTS 2.01 ACCEPTABLE MANUFACTURER S A. Basis of design: Design is based on the 1301-CM Series Display Case Door System with Continuous Mounting Bars as manufactured by: C.R. Laurence Co., Inc. (CRL) / Blumcraft Tel: (800) 421-6144 Fax: (800) 587-7501 Email: architectural@crlaurence.com

3 www.crlaurence.com B. Subject to compliance with requirements, Display Case Door Systems from other manufacturers meeting the specified requirements may be acceptable. 2.02 MATERIALS A. LEED requirements: 1. Recycled Content Materials: Provide building materials with recycled content such that post-consumer recycled content plus one-half of pre-consumer recycled content constitutes a minimum of 20 percent of the cost of materials used for the project. See LEED Green Building Rating System. 2. Regional Materials: Provide a minimum of 10 percent (based on cost) of building materials that are regionally extracted, processed, and manufactured. B. Aluminum, Stainless Steel Clad, Brass or Bronze Clad C. Glass: Provide flat, fully tempered glass or annealed laminated glass in thickness indicated for doors and sidelites. 1. Tempered glass components that comply with ANSI Z97.1 and testing requirements of CPSC 16 CFR 1201 Category II. ASTM 1048. 2. Laminated annealed glass that comply with ASTM C1172, ANSI Z97.1 and testing requirements of CPSC 16 CFR 1201 Category II. 2.03 HARDWARE a. Thickness: 3/8 inch (10 mm) b. Thickness: 1/2 inch (12 mm) c. Thickness: 5/8 inch (16 mm) d. Thickness; 3/4 inch (19 mm) e. Edge treatment: Provide bright flat polished edges for all exposed edges of glass. f. Specify Glass Type: Clear, Starphire low-iron, Amiran anti-reflective, or other specialty glass types. g. All glass fabrication to be completed before laminating or tempering. h. Visible tong marks or tong mark distortions are not permitted in tempered glass. A. Rail Configuration: Full width at top and bottom of doors as indicated on drawings. B. 1-1/4 (31.8 mm) square in aluminum; 1-3/8 (35 mm) square when clad. C. Continuous mounting bars measuring 2 (50.8 mm) high by 1-1/4 (31.8 mm) wide in aluminum or 1-3/8 35 mm) wide with clad, are available in finishes to match the door rails top and bottom. D. Center pivots to be AP-150 at top; BP-150 at bottom. E. #7301 Lock accepts a standard mortise key cylinder. Mounts in top or bottom continuous mounting bars or both. Note: Lock may also be shipped loose to be mounted in the casework without mounting bars (Specify). F. Accessory Fittings: Provide manufacturer s standard accessories of the type indicated. Comply with requirements indicated for kind and form metal and finish of door fittings. 1. Overhead door stop: Standard Door Stop or Roller Catch/Stop to be #593 with strike plate in top rail (Specify). 2. Sidelite Systems: Provide sidelite systems with matching glass, metal rail, continuous

mounting bar, and finish of door. G. Anchors and Fasteners: Manufacturer s standard concealed anchors and fasteners. Do not use exposed fasteners. H. Weatherstripping: Can be applied to edges of glass and in the T-slots of the top and bottom rails to help reduce air and dust infiltration. The weatherstripping shall be pile and replaceable without removing doors from casework. 4 2.04 FABRICATION to as A. General: Fabricate Display Case Door components to designs and sizes indicated. Sizes of doors and profile requirements of hardware are indicated on the drawings. 1. Do not permit cutting, drilling or other alterations to glass after tempering. 2. Fabricate work to accommodate required hardware, anchors, reinforcement, and accessory items. B. Prefabrication: Complete fabrication, assembly, finishing, hardware application and other work the greatest extent possible before shipment to the project site. Disassemble components only necessary for shipment and installation. C. Continuity: Maintain accurate relation of planes and angles with hairline fit of contracting members. 2.05 METAL FINISHES: (List one or more finishes) A. Aluminum: 1. Satin clear anodized 2. Black bronze anodized 3. Powder coated (specify color) 4. Painted (specify color) B. Stainless Steel Clad: 1. Satin #4 directional polish (US32D) 2. Highly polished #8 non-directional (US32) C. Naval Bronze Clad: 1. Satin directional polish (US10) 2. Highly polished non-directional (US9) 3. Statuary (US10B) D. Brass Clad: 1. Satin directional polish (US4) 2. Highly polished non-directional (US3) PART 3 - EXECUTION 3.01 EXAMINATION A. Examine substrates and supports with the installer, present for compliance with requirements indicated, installation tolerances and other conditions that affect the installation of Display Case Door Systems. Correct unsatisfactory conditions before proceeding with the installation.

5 1. Do not proceed with installation until unsatisfactory conditions are corrected. 3.02 INSTALLATION A. Install Display Case Door Systems and associated components in accordance with manufacturer s printed instructions and recommendations. 1. Verify units level, plumb and true line. 2. Lubricate hardware and other moving parts as required. 3.03 ADJUSTING A. Adjust doors and hardware to provide an acceptable fit at meeting points and at weatherstripping for smooth operation and dust tight closure. B. Hardware: Adjust operating hardware to ensure proper operation. 3.04 CLEANING A. Clean door and frame surfaces after installation, exercising care to avoid damage to the finish. B. Clean glass surfaces after installation, complying with requirements contained in the Glass and Glazing section for cleaning and maintenance. Remove excess glazing sealant compounds, dirt or other substances. 3.05 PROTECTION A. Institute protective measures required throughout the remainder of the construction period to ensure that the Display Case Door Systems do not incur any damage or deterioration. END OF SECTION