Wearable Adaptive Refractor. Innovative, Electronic, Mobile and Wearable System of Adaptive Lenses.

Similar documents
WEARABLE WIRELESS ADAPTIVE REFRACTOR

2Win Binocular Mobile Refractometer and Vision Analyzer

Marco TRS Total Refraction System

Intelligent Refractor RT-5100

Tabletop Refraction System TS-310

Intelligent Refractor RT-5100

ERK-9000 Auto Ref/Kertometer

Auto Ref / Keratometer ARK-560A / 530A / 510A

Refractive Power / Corneal Analyzer. OPD-Scan III

VARILUX FITTING GUIDE GUIDELINES FOR SUCCESSFULLY FITTING VARILUX LENSES

AUTO REF / KERATOMETER ARK-560A / 530A / 510A

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Distribution of Refractive Error. 20 year old males. Distribution of Aberrations

UNITY VIA PROGRESSIVE LENSES TECHNICAL WHITE PAPER

Learn Connect Succeed. JCAHPO Regional Meetings 2017

Impressive Wide Field Image Quality with Small Pupil Size

Excellent Measurement Accuracy ARK-530A / 510A AUTO REF / KERATOMETER

The First True Color Confocal Scanner

Today s subject Auto Refractometer & Auto Ref / Keratometer AR-1 & ARK-1

DESIGN OF GAUSSIAN SPATIAL FILTER TO DETERMINE THE AMOUNT OF REFRACTION ERROR IN HUMAN EYE

PREMIUM LENSES WITH VARIABLE BASE CURVE

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Optical Connection, Inc. and Ophthonix, Inc.

The First True-Color Wide-Field Confocal Scanner

OCULUS Binoptometer 4P

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

3/31/2016. Presented by: Bob Alexander, ABOM/NCLE-AC Lens Consultant Vision Ease. Everywhere and Sportwrap; Understanding Digital Technology

The First True Color Confocal Scanner on the Market

Faster, Easier and More Accurate AUTO LENSMETER LM-1200/1000(P)

Versatile Functionality RT-5100 SMART REFRACTOR

LM-1200 / 1000(P) AUTO LENSMETER

Lab Work For Rimless Eyewear Drilling

Smart Refractor RT-5100

HRK-7000 / HRK-7000A Auto Ref-Keratometer

Phoroptor VRx Digital Refraction System. User s Guide

CV-5000PRO Automated vision tester

Soft CL Multifocals Design and Fitting. Soft Multifocal Lens Designs. Issues Surrounding Multifocals. Blur Interpretation. Simultaneous Vision Designs

Wave Front Topography. ReSeeVit Evolution Topography Module for Modi Topographer

PROVISIONAL PATENT FOR MEASURING VISUAL CYLINDER USING A TWO-DIMENSIONAL SURFACE ABSTRACT OF THE DISCLOSURE:

OPTICS BASIC. Course Objectives WELCOME!!! Refractive Error and How Spectacle Lenses Correct It. Basic Anatomy. Hyperopia - Far Sighted PTICS:

Chapter 3: LENS FORM Sphere

Fax: (800) Phone: (800) Fax: (800)

PART 3: LENS FORM AND ANALYSIS PRACTICE TEST

FITTING GUIDE. Duette Hybrid Contact Lenses Duette Progressive Hybrid Contact Lenses - Center Distance - Center Near

digital lens designs

Sirius TOMOGRAPH AND CORNEAL TOPOGRAPHER

A Checklist for Managing Spectacle Lens Complaints. Presented By: Raymond P. Dennis, M.A. (Ed.) Middlesex Community. Patient Complaints

Concepts of Optics Quiz. 8. Spherical lenses focus along a single point; cylindrical lenses focus along a.

3/6/2014. Because: Answer: Early studies comparing acuity with spectacles vs. scl or rigid cl s

ATLAS Corneal Topography System

Phernell Walker, MBA, ABOM Heart of America Eye Care Congress 2019

Handheld Ref/Keratometer / Handheld Refractometer HandyRef-K / HandyRef

Dispensing 1. Prepared by Hatem S.H. Barhoom MHSC (clinical optometry) UKM Malaysia

Auto Ref / Kerato / Tono / Pachymeter TONOREFTM III

Puntino. Shack-Hartmann wavefront sensor for optimizing telescopes. The software people for optics

Lecture 8. Lecture 8. r 1

Optical Path Difference Scanning System OPD-Scan II ARK-10000

PART 3: LENS FORM AND ANALYSIS PRACTICE TEST - KEY

LENSES. Materials, Types and Treatments. Mary E. Schmidt, ABOC, CPO

055_056_varilux_divider.indd 55 VARILUX VARILUX

SYSTEM CHART SC-1700 Pola / 2000

LENSES. Materials, Types and Treatments. Single Vision. Aspherical Lens Forms

An Application of Lenses: The Human Eye. Prof. Jodi Cooley Supplementary Material for PHY1308 (General Physics Electricity and Magnetism)

Fitting Manual Use with kerasofttraining.com

Page 1

Copyright 2016, Phernell Walker, BSB, ABOM

HOYA aspherical IOL with ABC (Aspheric Balanced Curve) Design

Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN

Optical Perspective of Polycarbonate Material

Non-Mydriatic Auto Fundus Camera AFC-330

A Handbook of Trial Lens Set 158 pcs

Wavefront-Guided Programmable Spectacles Related Metrics

Lens Design I. Lecture 3: Properties of optical systems II Herbert Gross. Summer term

Optics of the Human Eye

Visual acuity finally a complete platform

Lens Design I. Lecture 3: Properties of optical systems II Herbert Gross. Summer term

5 Easy Steps to Purchasing Glasses Online

FITTING GUIDE. Applications. Design Options THE CRISP, CLEAR VISUAL ACUITY OF A GP LENS MEETS THE HYDRATING COMFORT OF A SOFT LENS

Eschenbach Low Vision Training Program

Irregular Cornea. ROSE K2 Soft TM. Practitioner s Fitting Guide

Industrial quality control HASO for ensuring the quality of NIR optical components

(495) (495)

Subjective refraction

Multifocal Contact Lenses. Steps for Success. Disclosures. Patient Selection. Presbyopic Soft Contact Lenses: Options for Success

Philips Vari-Lite TECHNICAL FOCUS: PRODUCT IN DEPTH

G.P. MULTIFOCAL LENSES: A FITTING WORKSHOP

Agenda. 1. EyeLT Step 1 2. EyeLT Step 2 3. EyeLT Step 3

Auto Ref/Kerato/Tonometer TONOREF 2

Pantoscopic tilt induced higher order aberrations characterization using Shack Hartmann wave front sensor and comparison with Martin s Rule.

Keratometry: Vertical Axis. Axis

Improving Lifestyle Vision. with Small Aperture Optics

KODAK Unique DRO Progressive Lens BE UNIQUE IN YOUR MODERN WORLD

Copyright Indizen Optical Technologies

Impression - Individual Lenses from Rodenstock.

The Unique Mu l t i f o c a l S i l i c o n e H y d r o g e l

MULTIFOCAL CONTACT LENSES INTRODUCTION

EXC500p-- PATHOLOGY MICROSCOPE. EXC500hd -- HD DIGITAL PATHOLOGY MICROSCOPE. EXC500r -- RESEARCH MICROSCOPE EXC500-LABORATORY SCOPE

Instruments for refraction and diagnosis. Catalogue

The TRIumph of Excellence

30 Lenses. Lenses change the paths of light.

Transcription:

Wearable Adaptive Refractor Innovative, Electronic, Mobile and Wearable System of Adaptive Lenses.

2 www.adaptica.com

Adaptica was founded in 2009 as a spin-off of the University of Padova, Italy specialising in adaptive optics and optoelectronics applied to Industry and astronomical research. Adaptica leverages on its technological knowhow and competences in astronomy to move from a better vision of the universe and its galaxies towards exploring vision and the human eye. Adaptica soon expanded into health-care, with a particular focus on vision and eye-care. It develops and manufactures smart, mobile, easy to use diagnostic pieces of equipment that are currently distributed in over 40 countries worldwide.

Technology Evolution in Subjective Refraction The Objective and Subjective Refraction Exam Subjective Refraction began a long time ago using trial frames with trial lenses. Manual and automated phoropters were then developed to speed up the process at the cost of less freedom for the patient and other disadvantages. VisionFit brings subjective refraction back to the trial frames modality and well combines the advantages of both methodologies (speed of operation and maximum freedom for the patient). Revolutionizing the Measurement of Subjective Refraction VisionFit TM is an innovative electronic, tunable, all-in one, solid state, mobile and wearable system of lenses. It performs a subjective sight examination and it effectively replaces both the trial glasses and the manual/electronic phoropter functionality. By using the VisionFit in combination with Adaptica s 2WIN binocular handheld refractometer and vision analyzer, the operator performs an objective and subjective refraction exam in a few minutes only, with maximum mobility and flexibility. The system provides final guidance for the production of standard and customized prescription lenses and also allows subjective refraction to be performed in association with other biomedical devices (e.g. stabilometric platform) and with other devices used by the patient. 4 www.adaptica.com

VisionFit TM Benefits VisionFit effectively combines all the features and advantages of both the trial frame and the manual/automated phoropters. Wearable and mobile - it fits just like a trial frame. 2 Enables examining in free posture. Small footprint and reduced exam time. 4 Increases peripheral vision. 5 Doesn t require control of the patient s position. 6 Ideal with non-cooperative patients. 7 Connectivity, broad recording and printing capabilities. 8 Adjustable step resolution down to 0.05 D. 9 Same standards of speed, fluidity and symmetry of digital phoropters. 0 Subjective refraction can be performed with the patient in his/her usual working environment and posture. The aberration lens extends the accuracy of the correction thanks to a high order aberration system. 2 Does not require any infrastructure nor any special installation procedure. Subjective refraction can be performed in association with other biomedical devices (e.g., stabilometric platform). 4 Subjective refraction can be performed in association with other devices in use by the patient (e.g., bite, planters). 5

VisionFit TM in Detail The Electronic Trial Frame Comes in Two Options VisionFit includes a computer integrated control unit featuring a display screen, keyboard controller, commands and connectivity capabilities. The wearable electronic trial frame features two tunable lens sets each composed of three adaptive lenses (spherical, cylindrical and aberration) with add-on lens support. The Electronic Trial Frame 2 4 Bridge height adjustment Vertex distance adjustment Pupil distance adjustment Pantoscopic tilt Adjustable Helmet Regular trial frame configuration with Velcro strap 4 2 6 www.adaptica.com

The Electronic Trial Frame Wearing the VisionFit electronic trial frame as a traditional trial frame, the subject looks at the eye chart or any other near or far target in any environment, either sitting or standing, thus allowing subjective refraction to be performed with the subject in his/her usual working environment and posture. Thanks to VisionFit lens technology, the subject can also move around with no operator intervention. VisionFit Adaptive Technologies The wearable trial frame; each tunable lens set includes a stack of 4 elements: Adaptive Spherical Lens Adaptive Cylindrical Lens Adaptive Aberration Lens Additional Lens Support Adaptive spherical lens technology: Membrane deformation, liquid within 2 surfaces and electronic control. The adaptive lenses of the stack are electronically tuned by the Control Unit without any other operator action. The Adaptive Lenses Stack Adaptive Spherical Lens 2 Adaptive Cylindrical Lens Adaptive Aberration Lens 2 Adaptive cylindrical lens technology: Rotating cylinders, continuous power, position adjustments, and electronic control. VisionFit Aberration Lens Aberration lens technology: liquid lens with 2 transparent actuators on a glass surface; this improves the performance of the optical system to correct aberrations. Adaptive Aberration lens. Glass (electrostatic effect) 2 Transparent actuators layer 2 Membrane 4 Liquid lens, flow pressure 4 An example of a trifoil wave-front correction by VisionFit. 7

The Control Unit and How to Read the Display The Control Unit is a tabletop driver featuring a computerintegrated unit, a display, keyboard controller commands and connectivity capabilities. 5 2 6 4 5 7 8 9 0 2 4 2 4 5 6 7 8 9 0 2 4 5 On-off / Clear Save / Print Menu Shift Tab Both Eyes Right Eye Left Eye Sphere Cylinder Axis Addition Fog / Retinoscopy Function Cross Cylinder Function External Chart Buttons 8 www.adaptica.com

Self-calibration VisionFit features a self-calibration procedure to ensure accuracy and reliability. Physical Adjustment Refraction Data Window Values from 2WIN - Autoref Status Bar Cross Cylinder and Axis Orientation Values from 2WIN - Autoref Right Eye Indicator 2 Left Eye Indicator Pupillary Distance 4 Vertex Distance 5 Sphere 6 Cylinder 7 Axis 8 Addition 9 Visual Acuity 0 Fogging Axis / Cross Cylinder Fields 2 WiFi activity flag Adaptive lenses status flag 4 2 4 5 6 7 8 9 0 2 4 9

0 www.adaptica.com

VisionFit TM - the unique wearable adaptive refractor for the most advanced subjective sight examination. VisionFit is a true technology revolution, a step forward that completely changes the paradigms of subjective refraction measurement. VisionFit combines the advantages of the classical trial frames examination (eg. ability to perform subjective refraction in free positions of the patient and of the instrument) with the benefits of the examination conducted by manual or automatic phoropters (eg. exam speed and continuity/fluidity in changing the lenses power). The exam is performed directly in the subject s environment and allows to analyze the effects of different prescriptions on the postural behavior. VisionFit performs a subjective sight examination by electronic and software control and in natural conditions, in a non-invasive way that is not bound by the size and postural difficulties inherent to the use of traditional instruments. The ergonomics of VisionFit allows a great versatility of use and transportability in wide range of environments and diagnostic contexts, with no need of dedicated infrastructures and complicated installations. VisionFit represents a turning point in the optimized assessment of refractive defects, as it takes into account and corrects high-order aberrations such as spherical, coma and trefoil, thus determining the optimal value of sphere, cylinder and axis. Moreover, thanks to the High Order Aberration Setup (a special software application under development) the versatile VisionFit optical system enables the operator to preset and/or compensate high order aberrations in order to make the best possible viewing experience possible.

Operating VisionFit TM VisionFit TM features a self-calibration procedure to ensure accuracy and reliability. It does not require any special installation procedure. 2 The patient wears the VisionFit lens frame like a regular trial frame and looks through it at an eye chart or any other near or far target. The patient can be sitting, standing or in any other desired position and/or environment. 4 The eye chart and/or target can be placed at different distances, depending on the type of exam. The operator adjusts the device in order to change the position and configuration of the optics, asking the patient for a subjective feedback. 5 6 The operator selects the output values for both glasses and contact lenses prescriptions. VisionFit provides versatile prescription printing options. 2 www.adaptica.com

VisionFit performs all the regular steps of subjective refraction, such as variable distances retinoscopy, presbyopia and cross cylinder exam. It is also compatible with the standard add-on lenses, occluders or filters. All-in-one objective and subjective refraction. The 2WIN measures binocular refraction and data is transferred to VisionFit via WiFi. Once set-up, VisionFit operates just like an automated phoropter with the same or improved standard of speed and fluidity, while offering numerous benefits in terms of patient freedom and operator interaction. VisionFit offers a broad range of optical evaluation with different static and dynamic visuo-postural conditions to achieve the best dioptric correction.

Technical Specifications Spherical correction range -0/+0 D and -20/+20 D with the use of an additional lens with prescription steps of 0.25 D and variable fluidity steps (adjustable from 0.05 to 0.25 D) with the use of the basic spherical lens. Additional Features Cylindrical correction range 0 to 0 D by steps of 0.25 D Axis adjustment range -80 by steps of Additional prismatic lenses range (optional) 0 to 0, steps (add on no automatic) Add-Ons A set of add-on lenses is included in the VisionFit basic package to perform all the tests of refraction procedure. Tolerances range of lenses according to ISO 04, 4. Corneal vertex distance range Manual pupil distance adjustment range 0-8 mm 50-80 mm, separated right and left Storage VisionFit features data storage capability (micro SD card). Device free aperture 0 degrees Display color LCD,.5 inches WiFi Module Bluetooth Module Power requirement Radicom, model: WiFiHU-a IDATA, USB 2.0 Bluetooth Mini Class 2+EDR Voltage: 00-240 VAC, 50-60 Hz - Power consumption: 60 VA Wireless VisionFit easily connects to a local Wireless network to communicate with the 2WIN refractometer and/or other WiFi devices. 4 www.adaptica.com

VisionFit TM - the unique wearable adaptive refractor for the most advanced subjective sight examination. 5

adimer.net Rev. 0. - 205 EN Adaptica Srl C/o Net Center Via San Marco, 9/H 529 Padova, Italy Ph/ Fax +9 049 77 968 www.adaptica.com info@adaptica.com