nd30pnet - METER Of POwER NETwORk PARAMETERS with profinet EXAMPlE Of APPlICATION MEASUREMENT ANd VISUAlIZATION Of POwER NETwORk PARAMETERS

Similar documents
nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS

N100. example of application Ethernet www/ ftp. Ethernet TCP IP RS X MeaSUreMent of power network parameters.

ND40 V V. Ethernet www/ ftp / smtp. Ethernet TCP IP RS-485 USB HOST /SD CARD.

a * example of application MeaSUreMent and ViSUalization of power network parameters Ethernet TCP IP RS-485 USB HOST /SD CARD

new! nd40 example of application MeaSUreMent and ViSUalization of power network parameters Ethernet www/ ftp / smtp Ethernet TCP IP RS-485

POWER NETWORK MEASUREMENTS Analysers, Multimeters & Transducers

N30P DIGITAL PANEL METER

POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL

PROGRAMMABLE TRANSDUCER OF DC CURRENT AND DC VOLTAGE SIGNALS P20H TYPE

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

N E W functions! Modbus. Wireless transmission - SM ma TCP IP ma. NA5 meter with bargraph. k *

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

SEPARATOR P20G TYPE USER S MANUAL

DIGITAL PANEL METER N24 AND N25 METER SERIES

EA16, EB16, EA17, EA19, EA12 MOVING-IRON METERS Ammeters and Voltmeters

DIGITAL SYNCHRONIZING UNIT KS3.2 SERVICE MANUAL. 144 x 144 x 77 mm C E R T I F I E D

POWER NETWORK PARAMETER METER N13 SERVICE MANUAL

TRANSDUCER OF NETWORK PARAMETERS P43 TYPE

POWER NETWORK PARAMETER ANALYSER N10

RE92. CHECKMATE. Dual loop controller for industry purpose.

ND40 - POWER NETWORK ANALYZER /RECORDER

Monitoring Electric Network Via Internet

METER OF NETWORK PARAMETERS ND20 TYPE

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

N24, N25 DIGITAL PANEL METER

Power-meters three-phase

ULTRA RAPID POWER QUALITY ANALYZER

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

Data Sheet. RISH Master Record %THD

Power Meter Series PM3200 Functions and characteristics

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

Digital Meters With A Multicolour Bargraph LEL-NA3 one-channel LEL-NA5 one-channel LEL-NA6 two-channel

RAIL MOUNTED NETWORK METER TYPE N27P USER S MANUAL

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID

Energy Management Modular Smart Power Transducer Type SPT-90

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

TEMPERATURE CONTROLLER RE21 TYPE

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

Digital Multifunction Instrument - Rish Master 3440

Energy Management Three-phase energy meter with output modules Type EM4-DIN

EM-72 Electricity Meters for Current Transformers

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

Smart Energy & Power Quality Solutions. Power Quality Analyser UMG 512-PRO. Data sheet

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

Electrical network management. Schneider Electric. PM3200 Technical Datasheet

UMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5.

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

3-phase meter with direct connection and pulse or Modbus RS485 output

ENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake

PLA 33. Power line analyzer. User and service manual. version 2.4

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

PEM353. Universal measuring device

Side view View from below Rear view

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

Application: Product Features: On site programmable PT/CT ratios: User selectable CT Secondary 5A/1A. User selectable PT Secondary

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

Power factor correction and harmonic filtering. Automatic power factor regulators

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

UMG 96RM Basic Device

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Measuring centers MC7x0 series Multifunction Meter MC740

PQM4000RGW Class A DIN 192x144 power quality analyzer with Rogowski coils

Energy Management. Type WM14-DIN Basic Version. How to order WM14-DIN AV5 3 D PGX. Type Selection. Input specifications. CptBSoft

Operating Guide October 2006

Power analyzers and Energy Meters Power Analyzer Type WM14-96

Centrale de mesure Power Meter PM500 Merlin Gerin

B850 Boiler House Energy Monitor

Power Meter Series PM9

Technical Data Sheet. x1000. kwh R Y B

UPM209 1/5A CT, 80A Multifunction three-phase meter

SUPPLY NETWORK ANALYZER CVM-96 SERIES

Networks IT, TN, TT networks 3 and 4-phase networks Up to 4 single-phase networks. Measured data memory 256 MByte Flash 32 MB SDRAM

UMG 103-CBM. Universal measurement device for DIN rails

B850 Boiler House Energy Monitor

POWER CONTROLLER RP1 type

Current Clamp. 210

ANALOG PANEL METERS. Moving-iron meters EB16 EA16 EA17 EA19 EA12. Moving-coil meters with rectifiers MA17P MA19P MA12P. 3-phase voltmeters

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus

Energy Management Energy Meter Type EM21 72R Retro-Fit

Energy Management Energy Meter GM3T E GM3T-RS485 E

T 1000 PLUS Secondary Injection Relay Test Set

METRAClip87 and 88 Clamp Multimeters

Multimeter 500CVD21 RTU500 series

Digital Multifunction Meter - RISH Integra 2000

Technical Data Sheet AMIK 300 / 301

Integra 1560 and 1580 Digital Transducer Systems

Contents. Introduction and description Package contents Device identification PM Options... 80

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

Transcription:

nd30pnet tri Measurement of 54 power network parameters, including current and voltage harmonics up to 51st, in 1-phase 2-wire or 3-phase 3 or 4-wire balanced and unbalanced systems. graphical color display: lcd TfT 3,5, 320 x 240 pixels, fully configurable by a user (10 vies, 8 parameters in each). Indications include the values of programmed ratios. Memory of minimum and maximum values. 2 configurable alarm outputs. Optional: analog output 0/4...20 ma and 2 PT 100 inputs (eg. for measurement of transformer temperature). digital output RS-485 - MOdBUS protocol. Modern and user-friendly ethernet/profinet (version 2.2.) interface. Programming of parameters using free econ software. Battery backup RTC. Overall dimensions: 96 x 96 x 77 mm. cal Sa fe t y Elec - METER Of POwER NETwORk PARAMETERS with profinet cat iii EXAMPlE Of APPlICATION Termopara K 1x Alarm 0/4...20 ma Alarm PLC T1 T2 RS-485 Modbus Grzałka SCADA LUMEL PROCESS Pt100 Pt100 Start/Stop SP1 SP2 Piec MEASUREMENT ANd VISUAlIZATION Of POwER NETwORk PARAMETERS phase voltages: U1, U2, U3 phase-to-phase voltages: U12, U23, U31 phase currents I1, I2, I3 active phase powers: P1, P2, P3 reactive phase powers: Q1, Q2, Q3 apparent phase powers: S1, S2, S3 active power factors: Pf1, Pf2, Pf3 reactive/active power factors: tg 1, tg 2, tg 3 active, reactive and apparent 3-phase power: P, Q, S mean 3-phase power factors: Pf, tg frequency f mean 3-phase voltage: US mean phase-to-phase voltage: Umf mean 3-phase current: IS 15, 30, 60 minutes mean active power: Pdemand mean apparent power Sdemand average current Idemand active, reactive and apparent 3-phase energy: EnP, EnQ, EnS active, reactive and apparent energy from external counter: EnPE total harmonic content coefficients for phase voltages and currents ThdU1, ThdU2, ThdU3, ThdI1, ThdI2, ThdI3 and for 3-phase voltages and currents ThdU, ThdI harmonics for current and phase voltage up to 51 st! temperature (2 x Pt100 input) 1

Features inputs outputs Galvanic isolation RS 485 Ethernet/ AC Pt100 RS 485 Ethernet/ RS 485 analog alarm Password protection RTC 0/4..20 ma Ethernet/ phasel1 phasel2 phasel3 Pt100 Supply THD Measuring range Current 1/5 A 1 A~ 5 A~ Voltage L-N 57.7 V~ 230 V~ 400 V~ Voltage L-L 100 V~ 400 V~ 690 V~ inputs Input type Digital interface Properties Input Pt100 (T1, T2) - option 2 x Pt100, 2-wire, -50...400 o C, basic error 0.5 % Interface type Transmission protocol Remarks RS-485 Modbus RTU 8N2,8E1,8O1,8N1 Address 1..247 baud rate: 4.8, 9.6, 19.2 38.4, 57.6, 115.2 kbit/s Ethernet / ICMP (Ping) / version 2.2 technical data Measured value Measuring range L1 L2 L3 Σ Active power P i, average active power P dt Reactive power Q i Apparent power S i, avarage apparent power S dt Active energy EnP (imported or exported) Reactive energy EnQ (inductive or capacitive) Apparent energy EnS 0.010..0.100..1.200 A (tr_i=1) 0.050..0.500.. 6.000 A (tr_i=1)...20.00 ka (tr_i 1) 5.7..11.5..70.0 V (tr_u=1) 23.0..46.. 276.0 V (tr_u=1) 40.0..80.. 480.0 V (tr_u=1)...480.0 kv (tr_u 1) 10.0..20..120.0 V (tr_u=1) 40.0..80.. 480.0 V (tr_u=1) 69.0..138.. 830.0 V (tr_u=1)...830.0 kv (tr_u 1).. (-)1999.9 W..(-)1999.9 MW (tr_u 1.tr_I 1).. (-)1999.9 Var..(-)1999.9 MVar (tr_u 1.tr_I 1)..1999.9 VA..1999.9 MVA (tr_u 1.tr_I 1).. (-)1999.9 Wh..(-)1999.9 MWh (tr_u 1.tr_I 1).. (-)1999.9 Varh..(-)1999.9 MVarh (tr_u 1.tr_I 1).. 1999.9 VAh..1999.9 MVAh (tr_u 1.tr_I 1) Class (*) / Basic error (*) class relative to the measured value acc. to EN61557-12 Class 0.2 Class 0.2 Class 0.5 Class 0.5 Class 1 Class 0.5 Class 0.5 Class 1 Class 0.5 Active power factor PF i -1.00..0..1.00 ± 0.01 of basic error Coefficient tg i -1.20..0..1.20 ± 0.01 of basic error (ratio of reactive power to active power) Frequency f 45.00..65.00 Hz Class 0.1 Total harmonic distortion 0.0..100.0 % of voltage THDU and current THDI Amplitudes of the voltage U h1...u h50, 0.0..100.0 % and current I h1 I h50 tr_i, tr_u ratio of current and voltage transformer Class 5 50 / 60 Hz Class 5 50 / 60 Hz 2

External features Readout field Safety and compability requirements Electromagnetic compatibility graphic color display LCD TFT 3,5, 320 x 240 pixels Overall dimensions 96 x 96 x 77 mm mounting hole 92.5 x 92.5 mm Weight 0.3 kg Protection grade from frontal side: IP65 from terminal side: IP20 Rated operating conditions Supply voltage 85...253 V a.c. (40...50...400 Hz), 90...300 V d.c. or 20...40 V a.c., 20...60 V d.c. power consumption 6 VA Power consumption in voltage circuit 0.2 VA in current circuit 0.1 VA Input signal 0...0.1...1.2 In; 0.1 0.2...1.2 Un for current, voltage, PF i, tgj i frequency 45...50...60...65 Hz, sinusoidal (THD 8%) Power factor Preheating time Ambient temperature -1 0 1 5 min. -10 23 55 C, class K55 acc. to EN61557-12 Humidity 0...40...65 95% without condensation Operating position any External magnetic field 40 400 A/m d.c. 3 A/m a.c. 50/60 Hz Short-term overload voltage input: 2 Un (5 sec.) current input 50 A (1 sec.) Admissible crest factor current: 2 voltage: 2 Additional error (in % of the intrinsic error) from ambient temperature change: < 50% / 10 C noise immunity acc. to EN 61000-6-2 noise emissions acc. to EN 61000-6-4 Isolation insured by the casing double acc. to EN 61010-1 Isolation between circuits basic acc. to EN 61010-1 Polution level 2 acc. to EN 61010-1 Installation category III acc. to EN 61010-1 Maximal phase-to-earth voltage for supply circuit and relay outputs 300 V for measuring input 500 V acc. to EN 61010-1 for circuits of RS-485, Ethernet, pulse input and output, analog outputs: 50 V Altitude a.s.l. < 2000 m connection diagrams option PNET PNET Description of meter connections strips Indirect measurement in 4-wire network - connection of input signals 3

Displaing of measurement Parameters up to 10 programmable screens (8 parameters per page); ability to change color for all screens Available colors for digital indications: two screens dedicated to harmonics; indication of individual harmonic for voltages and currents (up to 51st); bargraph presentation for all harmonics with zoom function easy to use and intuitive menu; information bar with status of: phase sequence, alarm outputs, temperature measurements* and RS-485 interfaces, time and date *- availability of feature depends on hardware version of ND30PNET 4

meter configuration with FREE econ Software ND30PNET - configuration Turn off forms validation for ND30PNET ability to configure and update ND30PNET with free econ software (via RS-485) ND30PNET *- availability of feature depends on hardware version of ND30PNET ordering code Meter ND30PNET - X X X XX X X Input voltage (phase/phase-to-phase) Un: 3 x 57.7/ 100 V, 3x 230/ 400 V 1 3 x 110/ 190 V, 3 x 400/ 690 V 2 Additional outputs /inputs: 2 relays 1 2 relays, 1 analog output, 2 inputs PT100 2 Supply: 85...253 V a.c., 90...300 V d.c. 1 20...40 V a.c., 20...60 V d.c. 2 Version: standard 00 custom-made* XX Language: Polish P English E other* X Acceptance tests: without additional quality requirements 0 with an extra quality inspection certificate 1 acc.to customer s request* X Order example: The code: ND30PNET - 1 2 2 1 00 E 0 means: ND30PNET - meter ND30PNET 1 - input voltage 3 x 57.7/ 100 V, 3x 230/ 400 V 2-2 relays, 1 analog output, 2 inputs PT100 1 - supply: 85...253 V a.c., 90...300 V d.c. 00 - standard version E - user's manual in English 0 - without additional quality requirements. * only after agreeing with the manufacturer 5

nd30pnet - METER Of POwER NETwORk PARAMETERS with profinet SEE AlSO: nd40 - power network analyzer/ recorder re92 - dual loop controller p30u- universal transducer of temperature and standard signals Ks31 - digital synchronizing unit n43- rail mounted 3-phase power network meter p43-3-phase transducer of power network parameters nd1 - analyser of network parameters Current transformers from 5 A up to 6 ka for more information about lumel products please visit our website: l Join us at facebook! 6 lumel s.a. ul. Sulechowska 1, 65-022 Zielona góra, POlANd tel.: +48 68 45 75 100, fax +48 68 45 75 508 Nd30PNET-19A_en export department: tel.: (+48 68) 45 75 139, 45 75 233, 45 75 321, 45 75 386 fax.: (+48 68) 32 54 091 e-mail: export@lumel.com.pl