NEMA Contactor and Starter Specifications

Similar documents
Open Type Without Enclosure

Open Type Without Enclosure

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

Starting Torque Controller Technical Data

Foundation Fieldbus Redundant Junction Box

Supplemental Motor Protection Devices Specifications

Analog Laser Sensor. Installation Instructions. Specifications. Summary of Changes. Description. Catalog Numbers 45BPD-8LTB1-D5, 45BPD-8LTB2-D5

Supplemental Motor Protection Devices Specifications

Deploying Current Transformers in Applications Greater Than 200 A

Solid-state Contactor Specifications

Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)

Variable Frequency Drive Packages with Harmonic Mitigation. Low Harmonic Drive Packages Engineered by Rockwell Automation

1715 Redundant I/O System Specifications

and START pushbutton mounted on the enclosure and a RESET button on the front wiring is as illustrated in the wiring diagram on Page 6-3.

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

AC-3 AC-1 230V 400/415V 500V 690V 115V 230V 200V 230V 460V 575V N.O. N.C. Qty. Cat. No. Screw Terminals. Spring Clamp Terminals. 40 C Pkg.

AC-Operated Latch Units PKLL11. Reset Input. DC-Operated Latch Units DC-PKLL10

NEMA Size 1 Cat. No. CN55DN3AB

1-12. Bulletin 400 Definite Purpose Contactors Approximate Dimensions. 2.1 max Typ max.

1-12. Bulletin 400 Definite Purpose Contactors Approximate Dimensions. 2.1 max Typ max.

Bulletin 700-RTC Solid-State Timing Relay

Basic Power Supply 5 A

Supplemental Motor Protection Devices Table of Contents

Solid-state Contactor Specifications

1394 External Shunt Resistor Kit

Ratings for Switching AC Motors AC-2, AC-3, AC / /

1715 Redundant I/O System Specifications

Bulletin 1497 Global Control Transformers

AU INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 02/2010 II_201A-AU_B1

Characteristics 5 TeSys k contactors and reversing contactors

FDM Medium Voltage Controller

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

AF91 Adjustable Frequency Drives Series B

3 - Protection components Circuit-breakers

AC Magnetic Starters (GE)

For additional PowerFlex 4 and 40 data and general drive information, refer to the following publications:

Ratings for Switching AC Motors AC-2, AC-3, AC / /

Kinetix 300 Drive (single-phase and three-phase) Power Specifications

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

Bulletin 140U Molded Case Circuit Breakers

T e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

S&C Series 2000 Circuit-Switchers Outdoor Transmission (69 kv through 230 kv)

150 C 30 F B D 8L 152H C 30 F BD 43 8L

PF/PFQ. High Amperage plug and receptacle. Main Advantages

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

200 Watt Passive Shunt Module

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

PowerFlex 400 Submittal

Variable Frequency Drives Basic Operating Principles and Core Maintenance Considerations

Distribution/Substation Transformer

IPS INTELLIGENT PUMP STARTER. Integrated Tru-power electronic motor and pump protection

SINGLE PHASE BUCK & BOOST TRANSFORMERS INSTRUCTION MANUAL

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Capacitor Switching Contactors

IC800SSD Hardware Manual Pub 348R5. for models. A publication of

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

ZOELLER ENGINEERED PRODUCTS NEMA 4X SIMPLEX & DUPLEX PANELS 1-20 BHP

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

Open Type. SAO12b SAG12b Use Size 0 Use Size 0. SBO2b SBG2b SBW12b SBW22b

SELECTION GUIDE. BULLETIN 156 Solid-State Contactors

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control.

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards

Orbital GFI Inverter Series

Transformer Questions & Answers

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service

CDV 22, 62. Voltage Controlled Overcurrent Relay GRID PROTECTION

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

Bulletin 100S-C/104S-C Safety Contactors. Bulletin 700S-CF Safety Control Relays. Table of Contents. Selection Guide

Instruction Bulletin Reduced Voltage Starters Autotransformer Type Class 8606

Motor starters. TeSys E. Designed for the essential

Bulletin 700-R -RM Sealed Switch Relays

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

PowerGard Series C 18-Pulse Enclosed Drive Controllers

Advanced Harmonic Solutions For Harmonic Current Distortion MOTION CONTROLS

Transformer Questions & Answers

Spring Return DuraDrive Proportional Actuator

Crane Control Class 7001

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

PKZ 2 Manual Motor Protectors Technical Data

SECTION AUTOMATIC TRANSFER SWITCH

Bulletin 520 Multi-Speed

Type VDG 13 Undervoltage Relay

Modular equipment. Presentation, standards. Standard contactors TeSys GC

CI-tronic Soft start motor controller

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

SYNCPRO II Brush-type Synchronous Motor Field Application and Protection System

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

General Purpose Drives

Short-Circuit Current Calculations

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)

SECTION PANELBOARDS

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Transcription:

Technical Data NEMA Contactor and Starter Specifications Bulletins 00, 0, 0, 0, 06, 06X, 07, 07X, 09,,, E/F/G, E/F/G Topic Page Specifications Electrical Ratings Mechanical Ratings, Construction, Environmental Short Circuit Rating 4 AC Coil Data Auxiliary Contacts (NEMA A600 and P00) Bulletin 9, 96 Load-life Curves 6 Approximate Dimensions 7 Type General Purpose Lift-Off Enclosure 7 Type Hinged Enclosure with or without Control Transformer 7 Type General Purpose Painted Enclosure 8 Type R/ Rainproof, Dusttight, 4/4X Watertight, Non-metallic Enclosure with or without Control Transformer 9 Type R/4/ Rainproof, Dusttight Industrial Use Enclosures 0 Unilock Enclosures Type R, 7 & 9, Class I Groups C & D, Class II, Groups E, F & G Divisions & Bolted Enclosures Type R, 7 & 9, Class I, Groups C & D, Class II, Groups E, F & G Divisions & 6 Summary of Changes This publication contains new and updated information as indicated in the following table. Topic Removed NEMA Pump Panels and Open Type enclosures. Page Not applicable Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Resource Pump Panel Specifications, publication -TD00 Industrial Automation Wiring and Grounding Guidelines, publication 770-4. Product Certifications website, http://www.ab.com Description Provides specifications for Bulletin and pump panels. Provides general guidelines for installing a Rockwell Automation industrial system. Provides declarations of conformity, certificates, and other certification details. You can view or download publications at http://www.rockwellautomation.com/global/literature-library/. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative.

NEMA Contactor and Starter Specifications Specifications Electrical Ratings NEMA Size 00 0 P 4 6 7 8 9 Load Voltage Continuous Current Rating Service Limit Current Rating () Maximum Hp Rating (Non-plugging and non-jogging duty) Maximum Hp Rating (Plugging and jogging duty) () Transformer Primary Switching kva Rating (Inrush Current 0 times Continuous Current) Transformer Primary Switching kva Rating (Inrush Current = 0 to 40 times Continuous Current) Capacitor Switching kvar () Maximum Circuit Closing Inrush Current [A] Peak Including Offset [V] [A] [A] / /4 00 -/ 0 -/ / 80 9 -/ 87 -/ 7 -/ 00 0 80 7 00 0 80 7 0 00 0 80 7 00 0 80 7 00 0 80 7 00 0 80 7 00 0 80 7 0 7 0 7 0 7 8 7 6 4 4 90 04 6 70 40 6 80 9 400 0 90 7-/ 7-/ 7-/ 7-/ 0 0 0 0 0 0 0 0 40 0 7 00 00 7 00 0 00 00 0 00 00 400 400 00 600 600 40 900 900 800 600 600 / -/ 7-/ -/ -/ -/ 7-/ 0 0 0 0 0 0 0 60 60 60 7 0 0 0 0 00 00 () Service-Limit Current Ratings The service-limit current ratings that are shown represent the maximum rms current, in amperes, which the controller shall be permitted to carry for protracted periods in normal service. At service-limit current ratings, temperature rises shall be permitted to exceed those obtained by testing the controller at its continuous current rating. The current rating of overload relays or the trip current of other motor protective devices that are used shall not exceed the service-limit current rating of the controller. () Plugging or Jogging Service The listed horsepower ratings are recommended for those applications requiring repeated interruption of stalled motor current that is encountered in rapid motor reversal in excess of five openings or closings per minute and shall not be more than ten in a ten minute period. () If maximum available current (at capacitor terminals) is greater than 000 A, contact your local Rockwell Automation sales office, Allen-Bradley distributor, or NEMA ICS- Standard. 0.6..4..4 4.9 6.. 4. 8. 0 4. 8. 6 0 6.8 4 7 4 4 7 4 68 7 4 08.8. 4...6 4. 8. 6. 7. 4 8 4 8 0 47 9 4 47 94 7 8 94 88 4 0. 0.6.. 0.6.... 4.. 4. 8. 0.4 6.8 4 7 6.8 4 7 4 4 7 4 68 0.9..6.8. 4....6 7. 8.9 6. 7.0 4 8 0 9 0 4 47 9 4 47 94 7 6. 7 7 67 40 80 00 80 60 00 60 0 400 40 480 600 60 70 900 66 670 40 88 48 947 8 6 66 9470 40 80 Rockwell Automation Publication 00-TD04C-EN-P - March 07

NEMA Contactor and Starter Specifications Mechanical Ratings NEMA Mechanical Life Maximum Number of Operating Time [ms] Size (Millions of Operations) Auxiliary Contacts Pick-up (Average) Drop-out (Average) 00 0 0 6 0 0 8 6 0 8 4 0 8 7 8 7 0 4 8 7 0 8 8 6 4 79 0 7 8 88 40 8 8 88 4 9 8 8 84 Construction NEMA Size Wire Size for Power Terminals Required Torque on Power Terminal Wire Clamps and Pressure Connectors or Lugs Type of Power Terminal 00 #6 0 AWG 9 lb in Pressure terminals 0 #4 0 AWG 0 lb in #4 8 AWG 0 lb in Saddle or wire clamps #4 4 AWG 4 lb in #8 /0 AWG 0 lb in 4 #6 4/0 AWG 7 lb in Pressure terminals #4 AWG 00 MCM 7 lb in 6 7 Lugs sold separately () 8 9 Direct bus connections only () Contact your local Allen-Bradley distributor or Rockwell Automation sales office. Contact Material Power Contacts Auxiliary Contacts Silver alloy Silver Requirements for Sizing of Wire All wire rated 67 F (7 C) or higher must be sized per the local Electrical Code for 67 F (7 C) wire. Environmental NEMA Operating Size Position 00 Horizontal 0 Vertical 4 6 Horizontal 7 8 Vertical 9 Operating Temperature Range Starters with eutectic alloy Overload relay +49 F ( +6 C) Starters with SMP Overload relay + F ( + C) (provided condensation is prevented) Altitude 0 000 feet before derating Corrosion- Resistance All metal parts are treated for corrosion-resistance Rockwell Automation Publication 00-TD04C-EN-P - March 07

NEMA Contactor and Starter Specifications Short Circuit Rating Combination contactors and starters with disconnect switch: Bulletin 0, 06,, E, F, and G Combination Contactors and Starters with Disconnect Switch: Bulletin 0, 06,, E, F, and G NEMA Size Fuse Type Available Short Circuit Amperes RMS Symmetrical [A] Maximum Voltage [V] 0 H, K 000 4 H, K 0 000 0 J, R 00 000 600 6 L 8 000 7 L 8 000 Combination Lighting Contactors with Disconnect Switch: Bulletin 0L Lighting Contactor Rating [A] Fuse Type Available Short Circuit Amperes RMS Symmetrical [A] Maximum Voltage [V] 0 00 H, K 000 00 00 H, K 0 000 600 0 00 J, R 00 000 Combination Contactors and Starters with Circuit Breaker: Bulletin 0, 07,, E, F, and G Enclosure Type NEMA Size Available Short Circuit Amperes RMS Symmetrical [A] Maximum Voltage [V], R, R/4/, 4/4X (stainless) Unilock R, 7, & 9 Bolted R, 7, & 9 R, R/4/, 4/4X (stainless) 0 6 000 480, R, R/4/, 4/4X (stainless) 0 000 Unilock R, 7, & 9 0 0 000 Bolted R, 7, & 9 6 8 000 R, R/4/, 4/4X (stainless) 7 000 Combination Lighting Contactors with Circuit Breaker: Bulletin 0L Enclosure Lighting Contactor Rating Available Short Circuit Amperes RMS Type [A] Symmetrical [A], R, R/4/, 4/4X (stainless) 0 00 6 000 Unilock R, 7, & 9 0 00 6 000 Bolted R, 7, & 9 0 00 6 000, R, R/4/, 4/4X (stainless) 0 00 000 Unilock R, 7, & 9 0 00 Unilock R, 7, & 9 0 00 0 000 Bolted R, 7, & 9 0 00 600 Maximum Voltage [V] 480 600 4 Rockwell Automation Publication 00-TD04C-EN-P - March 07

NEMA Contactor and Starter Specifications AC Coil Data NEMA Size Operating Volt Amperes Burden [VA] Heat Dissipation [W] Coil Operating Limits 60 Hz Coils Inrush Sealed 00 70 8.7 0 9 9.9 & P 9 9.9 ( poles) 40 9.9 (4 poles) 8.9 ( poles) 660 4 0 (4 poles) 840 8 0 4 ( poles) 69 4.8 4 (4 poles) 490 96 4.8 (Series L) 490 96 9.8 8 0% 6 () 4860 4 6.7 6 (Interposing relay).44.96 7 () Economized DC Coil 7 (Interposing relay) 74.40 9.84 8 () Economized DC Coil 8 (Interposing relay) 74.40 9.84 9 (4) Economized DC Coil 9 (Interposing relay) 44 9.0 () This rating is for the size 6 contactor coil only. All starters are shipped with an interposing relay as standard. () Size 7 starters are shipped with a 0 VA control circuit transformer and an interposing relay with a 0V coil. Voltage is then rectified to DC for the contactor coil. () Size 8 starters are shipped with a 0 VA control circuit transformer and an interposing relay with a 0V coil. Voltage is then rectified to DC for the contactor coil. (4) Size 9 starters are shipped with a 70 VA control circuit transformer and an interposing relay with a 0V coil. Voltage is then rectified to DC for the contactor coil. Auxiliary Contacts (NEMA A600 and P00) Bulletin 9, 96 AC Rating Designation A600 Maximum AC Contact Rating Per Pole Maximum Voltage [A] Continuous Carrying [VA] 60 Hz or 0 Hz Make Break Current [A] Make Break 0 60 6 0 700 70 40 0 0 700 70 480. 0 700 70 600. 0 700 70 Maximum DC Contact Rating Per Pole (Maximum Continuous Carrying Current is A) DC Rating Designation V DC 0V DC 600V DC 0. A 0. A P00. A (Requires Contacts in Series) (Requires Contacts in Series) Rockwell Automation Publication 00-TD04C-EN-P - March 07

NEMA Contactor and Starter Specifications Load-life Curves Bulletin 00 Line contactors and starters are designed to provide high performance in various applications. These load-life curves are based on Rockwell Automation tests according to the requirements defined in IEC 947-4. Actual contact life may vary based on the application, duty cycle, and environmental conditions from that indicated by the curves. To find the contactor s estimated electrical life, follow these guidelines: Choose the appropriate graph that most closely approximates the utilization category of the application. Locate the intersection of the life-load curve of the appropriate contactor with the application s operational current (I e ) found on the horizontal axis. Read the estimated contact life in millions of operations along the vertical axis. Contact Life for Mixed Utilization Categories AC and AC4 In many applications, the utilization category cannot be defined as either purely AC or AC4. In those applications, the electrical life of the contactor can be estimated from the following equation: L AC L mixed = + P AC4 L ( AC ) L AC4 Where: L mixed = Approximate contact life for a mixed AC/AC4 utilization category application L AC = Approximate contact life in operations for AC utilization category (from AC life-load curves below) L AC4 = Approximate contact life in operations for AC4 utilization category (from AC4 life-load curves below) P AC4= Percentage of AC4 operations Utilization Categories Category Typical Duty: ACStarting of squirrel cage motors and switching off only after the motor is up to speed. AC4Starting of squirrel cage motors with inching and plugging duty. Bulletin 00 Load / Life Curves AC and AC4 NEMA SIZE NEMA SIZE 0M 8M 6M AC 0M 8M 6M AC4 4M 4M M M OPERATING CYCLES M 800K 600K 400K 00K 00K 80K 60K OPERATING CYCLES M 800K 600K 400K 00K 00K 80K 60K 40K 40K 0K 0K 0K 0K OPERATIONAL CURRENT Ie (APMERES) OPERATIONAL CURRENT Ie (APMERES) 6 Rockwell Automation Publication 00-TD04C-EN-P - March 07

NEMA Contactor and Starter Specifications Approximate Dimensions Bulletins 00 and 09 Contactors and Starters, -Pole J H G Type General Purpose Lift-Off Enclosure NEMA Size/ Current Rating 00 A Width 6.7 (7) 7. (84) B Height 9.67 (46).8 () C Depth.8 (7).8 (7) Bulletins 00, 0, 09, 0E, 0F, and 0G Contactors / Starters, - -Pole Type Hinged Enclosure with or without Control Transformer D C B 8. F F 7/8 & -/8 DOUBLE K.O. PLACES ( ADDITIONAL KNOCKOUTS AT TOP) K ONE ADDITIONAL.8 L KNOCKOUT ON.8 RIGHT SIDE A (BOTTOM VIEW) 4.7 (LEFT VIEW) (FRONT VIEW) (BASE VIEW) SIZE 0- ONLY H E A Dimensions in Inches (Millimeters) D E F G H J K L 4.0 (04) 4.0 (04) Ø.8 [ 7, ] MTG HOLES.00 (). () E.88 (48).8 (60). 6.4 (6) 8.88 (6) C D.94.6 (4).94 (49).00.7 4.9 Ø. MTG HOLES.00 0.7.00 (). ().46 (7).46 (7)..6.6. (BASE VIEW) SIZE ONLY.8.8 (86).6 (9).7 Ø.8 MTG HOLES J B KNOCKOUTS FOR (4) PILOT DEVICES " X 0" X 6 () PILOT DEVICES 8" X 4" X 6 " X " X 9" DOOR PADLOCK FEATURE F NEMA Size/ Current Rating Bulletin No. A Width 00 00 & 09 0.00 00 & 09 (4) without transformer 00 & 09 with transformer 4.00 (6) 0 0 & 0 00 & 09.00 0 & 0 (0) G B Height.00 (8) 8.00 (47).00 (9) C Depth 6.9 (6) 6.9 (6) 8.0 (6) Dimensions in Inches (Millimeters) D E F Mounting Mounting.8 (48).8 (48) 7.89 (0).00 (7) 7.00 (78) 6.0 (6).7 (9).7 (46). () G Mounting 7.0 (9).0 (9) 0.0 (67) H.08 (7).00 ().08 (7) J (Mounting).7 (4).7 (400) 9.7 (0) Note: For Types R/, 4/4X, 4X, and Bolted Type 7 & 9 and R, 7 & 9 dimensions, contact your local Rockwell Automation sales office or Allen-Bradley distributor. Rockwell Automation Publication 00-TD04C-EN-P - March 07 7

NEMA Contactor and Starter Specifications Bulletins 00, 0, 0, 0, 06/X, 07/X, 09, /M/V, /M/V, 0E/F/G, E/F/G, and E/F/G Type General Purpose Painted Enclosure () A Size 4 Size NEMA Bulletin No. Approximate Dimensions in Inches (Millimeters) Approximate Size A B C D E F G Shipping Weight Height Width Depth Mounting Mounting Mounting Handle Depth [lb (kg)] 0... 0... 06X, 07X 0, 0,, 7.0 (968) 0.0 (67) 8. (0). (69) (). ().6 (4) 40 (8.4) 06, 07, M, M, 0... E, F, G, E, F, G 0 0. 9.88 7.6...6 90 0, 0, 0,,, (76) () () (70) (87) (87) (4) (40.8) 0E, 0F, 0G 4 00, 0, 09, 06, 07, E, F, G, E, F, G 0, 06, 07, 0E, 0F, 0G, E, 4 F, G, E, F, G 0, 00, 0, 09, 0E, 0F, 0G 0, 0, 06, 06X, 07, 07X,,, E, F, G 6 00, 0, 09, 0E E, F, G 0 (70) 6 (4) 60 (4) (9) 0. (77) 7.8 (949) () Sizes 0,, and have one top-mounting hole that is located on the center line. Larger size enclosures have two top-mounting holes that are located as shown..9 (84).79 (0) 6.00 (406) 47.6 (0) 7.6 (46) 6.69 (67). (87) 0 (08).88 (86). (87). (64).88 (86).6 (4) 7.6 (94) 7.6 (94) 0 (.4) 60 (6.) 40 (90.) 8 Rockwell Automation Publication 00-TD04C-EN-P - March 07

NEMA Conactors and Starters Approximate Dimensions Bulletins 00, 0, 09, 0E, 0F, and 0G Contactors / Starters, - -Pole Type R/ Rainproof, Dusttight, 4/4X Watertight, Non-metallic Enclosure with or without Control Transformer 0.8 () E A ø 0.4 MTG HOLES C D H J B TYPE R/4/ HAS CUT OUTS FOR () PILOT DEVICES TYPE 4/4X HAS INDENTS FOR ADDING HOLES FOR PILOT DEVICES DOOR PADLOCK FEATURE F G (FRONT VIEW) (RIGHTSIDE VIEW) NEMA Size/ Current Rating Bulletin No. A Width 00 00 & 09 00 & 09 without 0.00 (4) transformer 00 & 09 4.00 with transformer (6) 0 0 & 09 00 & 09.00 0 & 0 (0) B Height.00 (8) 8.00 (47).00 (9) C Depth 6.4 (64) 6.4 (64) 8.7 (8) Approximate Dimensions in Inches (Millimeters) D E F Mounting Mounting.8 (48).8 (48) 7.89 (0).00 (7) 7.00 (78) 6.0 (6).00 (76).00 (7) 4.4 () G Mounting 6.00 () 0.00 (4) 9.00 (9) H 7. (48) 0. (4) 4. (6) J Mounting 6.8 (46) 9.8 (49).8 (94) Rockwell Automation Publication 00-TD04C-EN-P - March 07 9

NEMA Conactors and Starters Approximate Dimensions Bulletins 00, 0, 0, 0, 06/X, 07/X, 09, /M/V, /M/V, 0E/F/G, E/F/G, and E/F/G Type R/4/ Rainproof, Dusttight Industrial Use Enclosures () NEMA Size 0... Bulletin No. Approximate Dimensions in Inches (Millimeters) Approximate A B C D E F G H J Shipping Weight Height Width Depth Mounting Mounting Mounting Handle Depth [lb (kg)] 06X, 07X 7.0 0.0 8. 8.88 ()..6 9.88 0.8 40 0, 07, 0,, (698) (67) (0) (7) () (4) (79) () (8.4) 06, 07, M, M, E, F, G, E, F, G 0 0. 0.9.8...6.8 90 0, 07, 0, 0,,, (76) () (9) (797.0) (87) (87) (4) (8) 0.8 () (40.8) 0E, 0F, 0G 4 00, 09, 06, 07, E, F, G, E, F, G 0, 0, 07,, 0E, 0F, 4 0G, E, F, G, E, F, G 00, 09, 0E, 0F, 0G 0 (70) 0, 0, 06,,, E, F, G 6 (4) 6 00, 0, 09, (),, 0E 6 () 60 E, F, G (4) 7, 84 (4) (9) 0. (77) 7.8 (949) 9. (00). (9).79 (0) 6 (906) 8 (47) () Sizes 0,, and have one top-mounting hole that is located on the center line. All sizes in large enclosures have two top-mounting holes that are located as shown. () Fusible disconnect switch with Class J fuses. () Fusible disconnect switch with Class R fuses..8 (0) 7.6 () 6.69 (67). (87) 0 (08).88 (86). (87). (64).88 (86).6 (4) 7.6 (94) 7.6 (94) 7.6 (94).8 (0) 6.6 (90) 6. (6) 0.7 (8) (.4). (8) 0 (.4) 60 (6.) 40 (90.) 60 (49.8) 0 Rockwell Automation Publication 00-TD04C-EN-P - March 07

NEMA Conactors and Starters Approximate Dimensions Bulletins 0, 0, 07, 09 and Unilock Enclosures Type R, 7 & 9, Class I Groups C & D, Class II, Groups E, F & G Divisions & -/6 (98) -/4 (98) -/8 (9) -7/6 (6) 7-/4 (84) -/4 (7) -/6 (7.) /4 NPT -/ NPT Pipe Tap Top and Bottom Pipe Taps Top and Bottom Sizes 0 -/ (648) () (8) 0-7/8 (0) 6 (406) (787) /4 NPT Pipe Tap Top and Bottom (76.) -/ NPT Pipe Taps Top and Bottom Sizes Rockwell Automation Publication 00-TD04C-EN-P - March 07

NEMA Conactors and Starters Approximate Dimensions Bulletins 0, 0E, 0F, 0G Starters Bolted Enclosures Type R, 7 & 9, Class I, Groups C & D, Class II, Groups E, F & G Divisions & NEMA Bulletins 0, 0E Bulletins 0F, 0G Size with CCT () without CCT () with CCT () without CCT () 0 Figure A Figure A Figure B Figure B Figure A Figure A Figure B Figure B Figure B Figure B Figure B Figure B Figure C Figure B Figure C Figure C 4 Figure C Figure C Figure C Figure C () CCT = Control circuit transformer -/4 [,6] -/4 [,9] 8 [0,] 9/6 [4,] (0) /8-6 0-/ [7,8] Figure A () RESET HOLES (UNUSED ARE PLUGGED) -/ [96,9] 4-/4 [68,4] /4-4 NPT --/ NPT SIZE -/ --/ NPT SIZE 0- -/6 [46] -/8 [66,7] -9/ [7,8] /6 [7,] 9-/6 [9,9] 0-/ [64] 4 HOLES -/ [9,] -/6 [4,] 6-/4 [4,8] (8) /8-6 Figure B () RESET HOLES 6-/6 [684,] -/ [647,7] () /4 NPT TOP & BOTTOM - -/ NPT -/ --/ NPT -/8 [66,] -/4 [9,] -/4 [7,] -/8 [07,6] -/ [6,8] /6 [0,6] 0-/8 [6,7] -/ [97,8] 9/6 [4,] () HOLES -/ [9,] -9/6 [47,4] 6-/4 [4,8] (6) /8-6 -/ [8,6] Figure C () RESET HOLES -/8 [797,] -/6 [8,] () /4-4 NPT -/-8 NPT --/ NPT -/ [88,9] -/8 [9,] -9/6 [64,9] -/6 [74,7] /6 [0,6] -9/ [94,6] -/6 [8,8] () HOLES 9/6 [4,] Rockwell Automation Publication 00-TD04C-EN-P - March 07

NEMA Conactors and Starters Approximate Dimensions Bulletins 00 and 09 Contactors Bolted Enclosures Type R, 7 & 9, Class I, Groups C & D, Class II, Groups E, F, & G Divisions & NEMA Bulletins 00 and 09 Size with CCT () without CCT () 0 Figure C Figure A Figure C Figure A Figure C Figure B Figure D Figure C 4 Figure E Figure E Figure F Figure F () CCT = Control circuit transformer 8-/4 [,] [7] / [0,4] Figure A EXTERNAL RESET 4 [,6] -/6 [8,] (0) /8-6 /4-4 NPT TOP & BOTTOM -/ --/ NPT TOP & BOTTOM [0,8] /6 [,8] 8-/4 [,] -7/ [6,] / [,7] 7-/ [78,6] 8-7/ [08,8] HOLES 8-7/8 [,6] -/8 [6,7] / [0,4] (0) /8-6 8-/4 [,] Figure B EXTERNAL RESET 8-/6 [46,] 7-/4 [48,] /4-4 NPT BOTTOM ONLY -/ --/ NPT TOP & BOTTOM -/4 [7,] -/ [0,] / [,7] /6 [,8] 7-/ [78,6] 8-7/ [08,8] HOLES -/4 [,6] -/4 [,9] 8 [0,] 9/6 [4,] (0) /8-6 0-/ [7,8] Figure C () RESET HOLES (UNUSED ARE PLUGGED) -/ [96,9] 4-/4 [68,4] /4-4 NPT --/ NPT SIZE -/ --/ NPT SIZE 0- -/6 [46] -/8 [66,7] -9/ [7,8] /6 [7,] 9-/6 [9,9] 0-/ [64] 4 HOLES Rockwell Automation Publication 00-TD04C-EN-P - March 07

NEMA Conactors and Starters Approximate Dimensions Bulletins 00 and 09 Contactors (Continued) Bolted Enclosures Type R, 7 & 9, Class I, Groups C & D, Class II, Groups E, F, & G Divisions & NEMA Bulletins 00 and 09 Size with CCT () without CCT () 0 Figure C Figure A Figure C Figure A Figure C Figure B Figure D Figure C 4 Figure E Figure E Figure F Figure F () CCT = Control circuit transformer -/ [9,] -/6 [4,] 6-/4 [4,8] (8) /8-6 Figure D () RESET HOLES 6-/6 [684,] -/ [647,7] () /4 NPT TOP & BOTTOM - -/ NPT -/ --/ NPT -/8 [66,] -/4 [9,] -/4 [7,] -/8 [07,6] -/ [6,8] /6 [0,6] 0-/8 [6,7] -/ [97,8] 9/6 [4,] () HOLES -/ [9,] -9/6 [47,4] 6-/4 [4,8] (6) /8-6 -/ [8,6] Figure E () RESET HOLES -/8 [797,] -/6 [8,] () /4-4 NPT -/-8 NPT --/ NPT -/ [88,9] -/8 [9,] -9/6 [64,9] -/6 [74,7] /6 [0,6] -9/ [94,6] -/6 [8,8] () HOLES -/4 [,8] -/6 [4,] 0 [08] 9/6 [4,] / [8,8] (8) /8-6 Figure F RESET HOLE 49-/6 [,] 4-/4 [060,] /4-4 NPT BOTTOM ONLY -/-8 NPT TOP & BOTTOM [7] -/8 [9,7] 4-9/ [70,9] /6 [7,9] -7/8 [6,9] 4-7/ [6,] () HOLES 9/6 [4,] 4 Rockwell Automation Publication 00-TD04C-EN-P - March 07

NEMA Conactors and Starters Approximate Dimensions Bulletins 0, 07, Starters Bolted Enclosures Type R, 7 & 9, Class I, Groups C & D, Class II, Groups E, F, & G Divisions & NEMA Bulletins 0 and Bulletin 07 Size with CCT () without CCT () with CCT () without CCT () 0 Figure A Figure A Figure B () Figure A Figure A Figure A Figure B () Figure A Figure A Figure A Figure B Figure B Figure B Figure B Figure C Figure C 4 Figure C Figure C Figure D Figure D Figure D Figure D () CCT = Control circuit transformer () Figure A should be used for 80VA maximum transformers -/4 [,6] -/4 [,9] 8 [0,] 9/6 [4,] / [8,7] (0) /8-6 0-/4 [7] Figure A () RESET HOLES 4-/4 [68,4] -/ [96,9] 6-/6 [4,] /4-4 NPT -/ --/ NPT SIZE 0- -/6 [46] -/8 [66,7] -9/ [7,8] /4 [9,] 9-/6 [9,9] 0-/ [64] (4) HOLES -/ -/6 [4,] [9,] 6-/4 [4,8] -/ [4,] -7/8 [7] / [8,] (8) /8-6 Figure B () RESET HOLES 7-9/6 [446,] -/ [647,7] 6-/6 [684,] () /4 NPT TOP & BOTTOM - -/ NPT -/ --/ NPT -/8 [66,] -/4 [9,] -/4 [7,] -/8 [07,6] -/ [6,8] /6 [0,6] 0-/8 [6,7] -/ [97,8] 9/6 [4,] () HOLES Rockwell Automation Publication 00-TD04C-EN-P - March 07

NEMA Conactors and Starters Approximate Dimensions Bulletins 0, 07, Starters (Continued) Bolted Enclosures Type R, 7 & 9, Class I, Groups C & D, Class II, Groups E, F, & G Divisions & NEMA Bulletins 0 and Bulletin 07 Size with CCT () without CCT () with CCT () without CCT () 0 Figure A Figure A Figure B Figure A Figure A Figure A Figure B Figure A Figure A Figure A Figure B Figure B Figure B Figure B Figure C Figure C 4 Figure C Figure C Figure D Figure D Figure D Figure D () CCT = Control circuit transformer -/ [4,] -/ [9,] -9/6 [47,4] 6-/4 [4,8] -/6 [68,] Figure C () RESET HOLES -/ [49,9] -/8 [797,] -/6 [8,] (6) /8-6 () /4-4 NPT -/-8 NPT --/ NPT -/ [88,9] -/8 [9,] -9/6 [64,9] -/ [8,6] -/6 [74,7] /6 [0,6] -9/ [94,6] -/6 [8,8] () HOLES 9/6 [4,] -/4 [,8] -/6 [4,] / [8,8] 0 [08] -7/8 [98,4] (8) /8-6 4-9/ [70,9] Figure D RESET HOLE 49-/6 [,] 4-/4 [060,] /4-4 NPT BOTTOM ONLY -/-8 NPT TOP & BOTOM [7] -/8 [9,7] /6 [7,9] -7/ [808,8] -7/8 [6,9] 4-7/ [6,] () HOLES 9/6 [4,] 6 Rockwell Automation Publication 00-TD04C-EN-P - March 07

NEMA Conactors and Starters Approximate Dimensions Notes: Rockwell Automation Publication 00-TD04C-EN-P - March 07 7

Rockwell Automation Support Use the following resources to access support information. Technical Support Center Local Technical Support Phone Numbers Direct Dial Codes Literature Library Product Compatibility and Download Center (PCDC) Knowledgebase Articles, How-to Videos, FAQs, Chat, User Forums, and Product Notification Updates. Locate the phone number for your country. Find the Direct Dial Code for your product. Use the code to route your call directly to a technical support engineer. Installation Instructions, Manuals, Brochures, and Technical Data. Get help determining how products interact, check features and capabilities, and find associated firmware. www.rockwellautomation.com/knowledgebase www.rockwellautomation.com/global/support/get-supportnow.page www.rockwellautomation.com/global/support/directdial.page www.rockwellautomation.com/literature www.rockwellautomation.com/global/support/pcdc.page Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete the How Are We Doing? form at http://literature.rockwellautomation.com/idc/groups/literature/documents/du/ra-du00_-en-e.pdf. Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page. Allen-Bradley, Rockwell Automation, SMP, and LISTEN. THINK. SOLVE are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 47 İçerenköy, İstanbul, Tel: +90 (6) 698400 Publication 00-TD04C-EN-P - March 07 Supersedes Publication 00-TD04B-EN-P - - February 06 Copyright 07 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.