Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

Side view View from below Rear view

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

02/11/2015

SHIMADEN DIGITAL INDICATORS

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

General Specifications

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

PQube 3 Specifications

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

CALYS Transportable documenting multifunction calibrator with high accuracy 0.01%

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

Custom "Compact" range with display CD20 Custom Part number

N30P DIGITAL PANEL METER

Technical Information Barrier RB223

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

UMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5.

Q.raxx A slimline RS / EC Universal Measurement System

FC Series Signal Conditioners

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

CALYS 100. Field precision documenting multifunction calibrator

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

Industrial Modbus I/O Modules

CALYS 150. Advanced documenting multifunction calibrator thermometer

3-phase meter with direct connection and pulse or Modbus RS485 output

RE92. CHECKMATE. Dual loop controller for industry purpose.

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

High Performance Process & Temperature Controllers

02/11/2015

General Specifications

Data Acquisition Modules/ Distributed IO Modules

Sarasota CM200 Sarasota HME900 Density Converter Electronics

02/11/2015

Technical Information RMS621

General Specifications

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

JUMO Wtrans Receiver with Wireless Data Transmission

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port

SolidFlow 2.0. Solid mass flow measurement. Product Information. SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S.

CALYS 75. Field documenting multifunction calibrator

General Specifications

Single phase meter with direct connection and pulse or Modbus RS485 output

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Picture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW

CALYS 150. Advanced documenting multifunction calibrator thermometer

RSMFX-2R MULTIFUNCTIONAL

MV110-8AS. Analog input module 8 channel. User guide

Process displays For standard signals, temperature, resistance measurement

P5201 Universal Programmable Transmitters with Galvanic Isolation

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

Isolators A3/1.

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

General Specifications

Multifunctional counter tico 772/773/774

CALYS 50. Field multifunction calibrator for basic use

UMG 509-PRO. Multifunction power analyser with RCM

Programmable AC Current Transducer MT418

General Specifications

Tap Changer Analyzer & Winding Ohmmeter RMO25TD

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

LAUREL ELECTRONICS, INC.

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

Excellent low-cost Process & Temperature Controllers

Modbus communication module for TCX2: AEX-MOD

WIRELESS MODBUS GATEWAY WGW410

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485

UniStream 5" Technical Specifications US5-B5-RA28, US5-B10-RA28

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement

RMA42. Technical Information

02/11/2015

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS

Type CP-S, CP-C & CP-A Switch mode

N100. example of application Ethernet www/ ftp. Ethernet TCP IP RS X MeaSUreMent of power network parameters.

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

PROCESS & TEMPERATURE CONTROLLERS

MICROFUSION FEATURES OPTIONS CERTIFICATIONS THREE PHASE SCR POWER CONTROLLERS

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

Networks IT, TN, TT networks 3 and 4-phase networks Up to 4 single-phase networks. Measured data memory 256 MByte Flash 32 MB SDRAM

08/07/2015

General Specifications

FLOW RATE CORRECTION CALCULATOR GDR 1403

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

new! nd40 example of application MeaSUreMent and ViSUalization of power network parameters Ethernet www/ ftp / smtp Ethernet TCP IP RS-485

An RS485 bus is used for command, monitoring and diagnostic information that can be supplied to a system controller.

Transcription:

Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without notice. Copyright 2016 TI-P408-01 AB Issue 3 Boiler House Energy Monitor Description The is a flexible and easy to use Boiler House Energy Monitor that accurately calculates the efficiency of the boiler based on measured inputs from fuel, feedwater, steam output, condensate return and blowdown. The is a boiler house energy monitoring solution that has been designed for organisations operating boilers on an existing installed base and for boiler OEM's where customers specify a requirement for energy monitoring. The calculates a boiler's 'real time' energy transfer efficiency from fuel to steam. It will also measure for energy losses from the boiler due to blowdown applications. Being fully compatible with a wide range of Spirax Sarco flowmetering products the is the heart of a fully integrated system that will provide Operating Managers in an increasing range of industries detailed information to be able to review boiler efficiency against past performance. The unit is available for either wall or panel mounting. The -W-2 wall mounted version is mains powered (100 to 250 Vac), while the -P-2 panel mounting version is intended for direct connection to a Low Voltage power supply typically found inside PLC panels, i.e. 24 Vdc. The is supplied with a default configuration that makes configuration easy, either off-line with the free PC based software wizard provided with each product. When the configuration has been completed, it can be saved to file or to the free USB memory stick provided, from where it can be plugged in and up-loaded directly into the unit. Alternatively, commissioning can be carried out via a hierarchical menu structure through the front panel. Full commissioning details are included in the Installation and Maintenance Instructions (IMI) supplied with the unit. Spirax Sarco offers a complete range of flowmeters for the measurement of: Gas, Feedwater, Steam and Condensate return. For existing installed flowmeters the can accept 4-20 ma, Pulse and RTD inputs. The is compatible with a large number of interfaces and protocols including: RS-485, Modbus RTU, BACnet MSTP, RJ-45 Ethernet, Modbus TCP / IP, BACnet IP, USB and Hosted http web. A GSM module can be connected to the RS-485 port which enables transfer of information about failures, alarms and measurement values in the form of SMS text messages. Standards and certification This range of products fully comply with the requirements of the European Directives and carry the The is available with the following certification: - Uncertainty Certificate / Inspection Report. Note: All certification / inspection requirements must be stated at the time of order placement. mark when so required. -W-2 wall mounted version The can calculate and display: - Energy transfer efficiency from fuel to steam - Potential energy losses from TDS and bottom blowdown applications -P-2 panel mounted version - Energy recovery from condensate return - Steam flow and pressure - Feedwater flow and temperature - Fuel flow For selection of the optimum unit for your application, please visit page 2 'Available options' before placing an order. Page 1 of 7

Applications Application Proposed flowmeter ( is the example supplied ) Meter output Gas (Oil, Coal) Thermal mass flowmeter for gas (MTL10) (0) 4-20 ma Boiler feedwater Magnetic flowmeter (ELM) (0) 4-20 ma Boiler steam output Flowmeter (Gilflo, ILVA) (0) 4-20 ma Condensate return Magnetic flowmeter (ELM) (0) 4-20 ma TDS blowdown TDS valve Relay (State) BB blowdown BBD valve Relay (State) Typical boiler house application Condensate return flowmeter and temperature measurement Feedwater flowmeter and temperature measurement Steam flowmeter and optional steam temperature and pressure Process Fuel supply BC3250 Controller Blowdown vessel TDS valve Fuel flowmeter BBD bottom blowdown valve Available options Both versions of the series have the same functions and are available as follows: -P for panel mounting and is powered by 24 Vdc. -W for wall mounting and has been adapted to be powered by 100 / 240 Vac. Each version is equipped with two analog outputs Offered versions of the instruments: -x -2 -P Panel mounted version. -W-2 wall mounted version -P-2 panel mounted version -W Wall mounted version. -2 Two analog 4-20 ma outputs. Page 2 of 7

Technical data for the series flow computers User interface, front panel Display type Display size / resolution LED indication Keyboard Inputs organization LCD TFT color, 3.5", with LED backlight 43.8 mm x 77.4 mm / 272 (RGB) x 480 px, 3 two-color LEDs, red / green: ALARM, REC, USB 19 membrane buttons 6 x I type (0 / 4-20 ma): IN1, IN2, IN3, IN4, IN5, IN6 Number of inputs 3 x RTD (4-wire): IN7, IN8, IN9 3 x PULS: IN10, IN11, IN12 I type (0 / 4-20 ma current loop analog inputs) Signal type Transmitter connection Input resistance Transmitters supply A / C converter resolution 0-20 ma or 4-20 ma 2-wire passive transmitter (supplied from ) or active transmitter (current source transmitter) 95 W ± 10% (protected with PTC 50 ma fuse in series) 24 Vdc +10% / -20%; max 22 ma per channel (protected with PTC 50 ma fuse and 100 Ω resistor in series) 18 bit (24 bit Sigma-Delta ADC) 50 Hz / 60 Hz filter Sinc3 digital filter Damping (1 st order Low Pass Software Filter time constant) Measurement resolution Accuracy (at T amb = +25 C / +77 F) 2 s / 5 s / 10 s / 20 s / 30 s / 1 min / 2 min / 3 min / 5 min > 0.01% of FS ± 0.1% of FS (typical W0.05% of FS) Temperature drift Maximum ±0.02% of FS / C Maximum input voltage Galvanic isolation between inputs ± 40 Vdc No; common potential of functional GND for all inputs Galvanic isolation to Analog Outputs, RS-485 / RS-422, Ethernet RTD type (3 analog inputs for temperature sensors) Sensor types Measuring range Sensor connection Wire resistance compensation Maximum resistance of connecting wires A / C converter resolution Pt-100 x K; Ni-100 x K; where K = 1..11 (K multiplier, e.g.: K = 2 for Pt-200) -200.. +850 C / -328.. +1562 F for Pt100 x K -60.. +150 C / -76.. +302 F for Ni100 x K 4-wire (2-wire with wire bridges) Automatic, additional manual in range -99.99.. +99.99 50 18 bit (24 bit Sigma-Delta ADC) 50 Hz / 60 Hz filter Sinc3 digital filter Damping (1 st order Low Pass Filter time constant) Measurement resolution Accuracy (at T amb = +25 C / +77 F) 2 s / 5 s / 10 s / 20 s / 30 s / 1 min / 2 min / 3 min / 5min > 0.05% of reading or 0.1 Ω (TBV) ± 0.5 C / ± 0.9 F (typical ± 0.3 C / ± 0.54 F) Temperature drift Maximum ±0.02 C / C / 0.036 F / F Max input voltage Galvanic isolation between inputs Galvanic isolation to Analog Outputs, RS-485 / RS-422, Ethernet ± 40 Vdc No; common potential of functional GND for all inputs Page 3 of 7

PULS type inputs (binary / pulse / frequency) Measuring range Minimum pulse width Accuracy for frequency measurement (at T amb = +25 C / +77 F) Maximum input voltage Galvanic isolation between inputs Galvanic isolation to Analog Outputs, RS-485 / RS-422, Ethernet Configuration (default): OC or Contact open / closed Open circuit voltage Short circuit current On / off threshold Configuration: Voltage Input Signal amplitude On / off threshold 0.. 20 khz (cut off for f < 0.001 Hz) (0..1 khz with filter jumper J1 / J2 / J3 ON) 25 μs (0.5 ms with filter jumper J1 / J2 / J3 ON) 0.02% ± 40 Vdc No; common potential of functional GND for all inputs (Internal jumper J4 / J5 / J6 ON) 5 Vdc 5 ma 2.7 V / 2.4 V (Internal jumper J4 / J5 / J6 OFF) 4.. 36 Vdc 2.7 V / 2.4 V Input resistance Calculation update rate 10 k Compensated flow and heat energy measurement 1 s Total accuracy of compensated steam, water, other liquid or technical gas flow measurement Typical: better then ± 0.5% (worst case: better then ± 2%) 4-20 ma analog outputs Number of outputs 2 Output signal Resolution Loop resistance (R L ) range for U CC = 24 V 4-20 ma passive (external current loop supply required) 16 bit DAC 0.. 600 Ω Minimum loop power supply voltage U CCmin = RL x 0.022 + 8 Maximum loop power supply voltage 28 Vdc Accuracy (at T amb = +25 C / +77 F) Better than ± 0.2% of FS / C Temperature drift Maximum ± 0.02% of FS / C Galvanic isolation to Analog Inputs, RS-485 / RS-422, Ethernet Binary outputs (-W-2) Number of outputs 4 Type of outputs Contact rating (resistive load) Maximum switching voltage Maximum switching power Binary outputs (-P-2) 3 pole (COM, NO, NC) electromechanical relay 3 A at 85.. 250 Vac / 30 Vdc 250 Vac / 125 Vdc 750 VA / 90 W Number of outputs 4 Type of outputs Contact rating (resistive load) Maximum ON resistance Galvanic isolation (optoisolation) 2 pole Solid State Relay 0.1 A at 24 Vac/dc (max 42 Vac or 60 Vdc) 20 Ω Page 4 of 7

RS-485 / 422 Transmission protocol ASCII Modbus RTU, BACnet MSTP and GSM Number of nodes in network 256 Maximum line length Baud rate Parity control Frame Internal terminating resistor Maximum bus terminal voltages 1 200 m (depends on quality of data cable and baud rate) 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, 115.2, 230.4 kbps Even, Odd, None 1 start bit, 8 data bits, parity 1 bit, 1 stop bit Yes, activated with DIP switch -8 V +13 V Minimal driver differential output voltage 1.5 V (for R L = 54 ) Minimum receiver sensitivity Short-circuit / thermal protection 200 mv Yes Galvanic isolation to Analog Inputs, Analog Outputs, Ethernet Ethernet port Transmission protocol Interface Data buffer Modbus TCP, ICMP (ping), DHCP server, http server, BACnet IP 10 BaseT Ethernet 300 B Number of opened connections (simultaneously) 4 Connection type LED indication Socket type USB port RJ-45 2 (build in RJ-45 socket) A type, according to USB standard Version USB 2.0 Recording format Rated supply voltage Supply voltage range Power consumption Rated supply voltage Supply voltage range Power consumption Wire connection / terminals Conductor cross Section Cable glands Power supply (-W-2) FAT16 (within a limited scope) 100-240 Vac; 50 / 60 Hz 85.. 264 Vac; 47.. 63 Hz Maximum 20 VA Power supply (-P-2) 24 Vdc 18.. 36 Vdc Wire terminals (-W-2) Maximum 8 W, device SELV & limited energy Spring type terminal block Solid 0.2.. 2.5 mm 2 Stranded 0.2.. 1.5 mm 2 Stranded with ferrule 0.25.. 1.5 mm 2 AWG 26.. 12 4 glands type M20, 2 glands type M16 Page 5 of 7

Wire terminals (-P-2) Wire connection / terminals Conductor cross Section Screw type terminal blocks, plug type Solid 1.5 mm 2 max Stranded 1 mm 2 max Stranded with ferrule 0.25.. 1.5 mm 2 AWG 30 / 14 Enclosure (-W-2) Enclosure type Dimensions (height x width x depth) Weight net (gross) Protection class Enclosure type Dimensions (height x width x depth) Panel cut-out dimensions Panel thickness Weight net (gross) Protection class (front / rear) Ambient temperature Relative humidity Altitude Wall mounting, Polycarbonate material 216 mm x 260 mm x 125 mm (without cable glands) 246 mm x 260 mm x 125 mm (with cable glands) 290 mm x 300 mm x 165 mm (in cardboard box) approx. 1.7 kg (2.1 kg) IP65 Enclosure (-P-2) Panel mounting, Lexan Resin 920 material 96 mm x 192 mm x 63.5 mm (without terminals) 96 mm x 192 mm x 72 mm (with terminals) 135 mm x 230 mm x 110 mm (in cardboard box) 186 mm x 92 mm 1.. 5 mm approx. 0.6 kg (0.7 kg) IP65 / IP20 Environmental conditions 0.. +55 C (32.. 131 F) 5.. 95% (non-condensing) 2000 m (6 562 ft) above sea level Storage temperature -30.. +70 C Overvoltage category Pollution degree III 3 Panel version (when installed in an enclosure) 3 Wall version LVD (safety) Electrical safety EN 61010-1 EMC Installation location Immunity EN 61326-1 Table 2 Radiated and conducted emissions EN 55011 and EN 55022 to Class B Indoor use only Page 6 of 7

Dimensions / weights (approximate) in mm and kg A B C D E Weight Wall mounted 257 217 134 30 * - 1.70 Panel mounted 206 110 72.3-9.5 0.60 * Approximate dimension as the cable glands are adjustable. -W-2 (wall mounted) A C -P-2 (panel mounted) A C B B E D Safety information, installation and maintenance For full details see the Installation and Maintenance Instructions supplied with the product. Installation notes: 1. The wall mounted -W-2 requires 3 mounting screws (not supplied) to mount to a wall or has optionally a DIN rail mounting. 2. The panel mounted -P-2 is supplied with mounting clamps. Disposal This product is recyclable. No ecological hazard is anticipated with the disposal of this product, provided due care is taken. How to order For the correct product nomenclature for the unit that best suits the intended application please revisit page 2 'Available options' before placing an order. Example: 1 off -W-2 wall mounted energy monitor with two analog 4-20 ma outputs, 240 Vac supply. Spare parts There are no spare parts available for the energy monitors. Page 7 of 7