SECTION COMMUNICATIONS COPPER BACKBONE CABLING

Similar documents
SECTION COMMUNICATIONS COPPER BACKBONE CABLING

SECTION COMMUNICATIONS COPPER OSP CABLING

Communications Integrators, Inc. June S. Wilson Street, Suite 105 Tempe, Arizona Toll Free (800) Web Site

UFGS (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

1. This Section specifies the ethernet Category 5E data cabling system for buildings and structures.

Canadian OSP Copper I-1. Table of Contents

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION ELECTRICAL IDENTIFICATION

St. Monica Food Pantry Low Voltage (600V and less) Conductors and Cables sys-tek No

Installation personnel should be familiar with applicable codes or established practices for their locale. Weather Reistant PVC Jacket

SECTION IDENTIFICATION FOR COMMUNICATIONS SYSTEMS

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

B. Division-16 Basic Materials and Methods section apply to work specified in this section.

A. Product Data: For each electrical identification product indicated.

SECTION CABLE TRAYS

DIVISION 1 - GENERAL REQUIREMENTS SECTION SUBMITTALS

b. Army Reserve Design Process Submittal Requirements (DPSR) c. USARC G-2/6 IT Design Whitepaper, 26 Jun 2012 ( ENCLOSURE 1)

Detailed Specifications & Technical Data

JEFFERSON LAB TECHNICAL ENGINEERING & DEVELOPMENT FACILITY (TEDF ONE) Newport News, Virginia

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP

SECTION EQUIPMENT WIRING

SECTION SUBMITTALS PART 1 - GENERAL 1.01 RELATED DOCUMENTS

A. Action Submittals: Written and graphic information that requires Architect's responsive action.

PROJECT TITLE PROJECT NO: CONTRACT TITLE UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

SECTION SUBMITTAL PROCEDURES

SECTION BUILDING WIRE AND CABLE

REQUEST FOR INFORMATION (RFI) RFI NO: /WJG

SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES

SECTION BULLET- RESISTANT DOORS

Voice/Data Identification. onlinecomponents.com THE LEADER IN COMMUNICATIONS LABELING 2004/2005

A. Action Submittals: Written and graphic information that requires Engineer's responsive action.

LAUSD Facilities Technology Program Management Group

B. The designated coverage areas shall include both indoor and outdoor coverage.

SECTION CABLE TRAYS FOR ELECTRONIC SAFETY AND SECURITY

SECTION III SUBMITTALS AND APPROVALS

Detailed Specifications & Technical Data

14 AWG 2 AWG: 600 Volt

SECTION IDENTIFICATION FOR ELECTRONIC SAFETY AND SECURITY

Hilti, Inc. November Dallas Parkway, Suite 1000 Plano, Texas Toll Free Website Guide Specification

Detailed Specifications & Technical Data

INDEX OF SPECIFICATIONS SECTION F SPECIAL CONDITIONS DIVISION 1 - GENERAL REQUIREMENTS:

SECTION TRACER WIRE FOR NONMETALLIC PIPE

SECTION CLOSEOUT SUBMITTALS SECTION CLOSEOUT SUBMITTALS

CHAPTER 29 PROJECT COMPLETION DOCUMENTS

SECTION MEDIUM-VOLTAGE CABLES

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

For crossing under a railroad, contact the specific railroad company's engineering department.


2016 Specification Treads, Base, Stringers and other Amenities Wausau Tile Precast Epoxy Terrazzo

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

SECTION SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES

.1 Applicability: These criteria shall be applied as follows:

GENERAL SUBSCRIBER SERVICES TARIFF Pembroke Telephone Company, Inc. Third Revised Contents Sheet 1 Cancels Second Revised Contents Sheet 1

EMMEGI ARCHITECTURAL FENCING MASTER SPECIFICATION SECTION METAL FENCING, GATES & RAILING SYSTEM PART 1 GENERAL

REVISION #1. Section. fire alarm B. C. the hot. intent of. required. manufacturer. materials. C. Warranty

Chapter 25. Lighting Plans

Category 7 A /Class F A Products

Electrical Wiring: Commercial, Seventh Canadian Edition

DETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL, TWELVE INDIVIDUALLY SHIELDED PAIRS 22 (7 X 30) AWG

New Product Bulletin. Belden Digital Audio Cable. Belden Brilliance AES/EBU

SECTION IDENTIFYING DEVICES

Wire Transmission Only with Sealing Current (4W TO W/SC) Channel Unit

East Central College

INSTALLATION & TESTING OF UNDERGROUND PRIMARY AND SECONDARY POWER CABLES PRIOR TO ENERGIZATION

SECTION ADMINISTRATIVE REQUIREMENTS

TRANSACTION RECORD TR

SPECIAL SPECIFICATION 6004 Digital Card Rack Inductive Loop Detector Assembly

SECTION EMERGENCY RESPONDER RADIO COVERAGE SYSTEMS

Filled Solid ALPETH Cable

MISSISSIPPI STATE UNIVERSITY Office of Planning Design and Construction Administration

FORM NWC-705. Section 1: General Information. Section 2: Collocation Information. Collocation Location:

A. Deviation from this standard must be approved by the Project Architect.

A. Product Description: Stranded conductor insulated wire.

Facility Services Subgroup Preface for Divisions 21` through 28

Success Depends on the Crimp

Re-Roofing Policy SPECIAL REQUIREMENTS AND NOTES

SECTION PANELBOARDS

Merrick Pet Care New Distribution Center Hereford, Texas

B. Manufacturers: Square-D, G.E. or Westinghosue.

Schluter -DITRA-HEAT Repair procedure for the DHE-HK Heating Cable

Campus Cable Plant Specification for Year 1 Wireless Coverage (Phase I)

USER MANUAL RM050A-R3, RM051A-R3 WALLMOUNT RACKS 24/7 TECHNICAL SUPPORT AT OR VISIT BLACKBOX.COM

FOR UL INTERNAL REFERENCE OR CSDS USE ONLY NOT FOR OUTSIDE DISTRIBUTION

McKenzie County Healthcare Systems

CLARK COUNTY FIRE CODE AMENDMENTS

SPECIAL SPECIFICATION LIGHTNING PROTECTION SYSTEM

.2 Accompany all submissions with a transmittal letter, in duplicate, containing:.4 Specification Section number for each submittal

Part Number: 7953A Cat 6 600V DataTuff, (4 pr) 23 AW G Solid BC, PP/PVC/PVC, Foil Shld, CMR, CMX-Outdoor

A. This section specifies procedural requirements for Shop Drawings, product data, samples, and other miscellaneous Work-related submittals.

High Voltage Instrumentation Cables for the ITER Superconducting Magnet Systems

Special Provision No. 999F29 March 2018 REQUIREMENTS FOR INSTALLATION OF METALLIC DOWELS INTO CONCRETE

FOR INTERCONNECT AND CROSS-CONNECT APPLICATIONS

UNION COUNTY VOCATIONAL-TECHNICAL SCHOOLS West Hall Addition Project Raritan Road, Scotch Plains, NJ

SPECIAL SPECIFICATION 1257 Digital Card Rack Non-Invasive Micro Loop Detector Assembly (8 Slot Rack)

COAX 101. Author: Rob Wessels. Vice President of Engineering

Standards Update Notice (SUN) Issued: June 6, 2017

B. Bidders shall acknowledge receipt of this Addendum in writing on his Proposal Form.

*********************************************************************************************************

Transcription:

PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications shall include all labor necessary to perform and complete such construction, all materials and equipment incorporated or to be incorporated in such construction and all services, facilities, tools and equipment necessary or used to perform and complete such construction. The work of this section shall include, but is not limited to, the following: 1. A complete copper twisted pair backbone cabling system to support voice circuit distribution as well as data communications with cables, termination hardware, splices, and necessary installation and supporting hardware. 1.02 QUALITY ASSURANCE B. Refer to Section 27-00-00 for general details. C. As noted in Section 27-00-00, all contractors and installers working on structured cabling system elements shall hold a current manufacturer s certification for each individual component they install. 1.03 CODES, STANDARDS, AND GUIDELINES A. UL 444 A. Except as modified by governing codes and by the Contract Documents, comply with the applicable provisions and recommendations in Section 27-00-00. B. Cal Poly ITS Telecomm group, Telecommunications Standards Document and the Labeling, Design & Syntax Standards in Appendix B. 1.04 SUBMITTALS A. Refer to Section 27-00-00 for general details. B. Shop Drawings: 1. Shop drawings shall show cable routing details. C. Submit Manufacturer s Cut Sheets for the following: 1. Any products not specifically listed in the PRODUCTS section shall require a submittal of the manufacturer s cut sheets and approval by the Cal Poly ITS Telecomm group. D. Manufacturers Testing: 1.05 IDENTIFICATION 1. Submit as testing results as required by Section 27-08-13. 2. Multi-pair copper riser cables: The Contractor shall submit two (2) sets of the manufacturer s test results for continuity, shorts and breaks. A. Machine generated, 1, nylon labels with black lettering shall be placed on all copper backbone and riser cables. Document Title 1 of 5

B. Labels containing a unique cable ID designator developed by the contractor using the Cal Poly ITS Labeling, Design & Syntax Standard in Appendix B and approved by a Cal Poly ITS Telecomm group shall be placed on both ends of all cables, 6 inches from the termination and/or terminal block, and in all pull boxes in the pathway. C. Subsequent to placing and terminating cables, the Contractor shall place the appropriate labels as indicated above. D. If at any time during the job the label becomes illegible or removed for whatever reason, the Contractor shall immediately replace it with a new label at the Contractor s expense. E. All labels shall be easily accessible, both physically and visually, upon completion of the job. F. Refer to Section 27-05-53 for additional details. 1.06 DEFINITIONS A. Backbone Cable as defined in this section shall be intra-building riser cable for use between EFs/TRs/ERs B. OSP Cable as defined in Section 27-13-14 is inter-building cable for use between EFs. 1.07 WARRANTY A. Refer to Section 27-00-00 for general details. PART 2 PRODUCTS 2.01 PRODUCT CONSISTENCY A. Product Consistency: Any given item of equipment or material shall be the product of one manufacturer throughout the facility. Multiple manufacturers of any one item will not be permitted. 2.01 COPPER CABLES GENERAL A. Cable jacket marking: Must be legible and shall contain the following information: 1. Manufacturer s name 2. Copper Conductor Gauge 3. Pair Count 4. UL and CSA listing 5. Manufacturer s Trade Mark 6. Category rating 7. Sequential foot markings, in one foot increments 2.02 COPPER CABLE (BACKBONE) A. Cable jacket shall be white, plenum rated, with black lettering. B. Cable must be ARMM riser rated. C. Cable construction specifications: 1. Core wrap Polypropylene Film. Document Title 2 of 5

2. Shield Corrugated Aluminum tape bonded to riser rated jacket. D. The cables consist of 22 AWG foam polyethylene insulated conductors with plenum rated skin formed into binder groups of 25 pairs using standard PIC color coding. E. Approved Manufacturer: Superior Essex or Cal Poly ITS Telecomm group approved equal PART 3 EXECUTION 3.01 GENERAL A. Location and placement of backbone cables shall be shown on the Drawings. Submit Shop Drawings to the ITS Telecomm group for approval of block field, protector and splice case layouts and locations as well as OSP cable routing before starting work. B. Backbone copper cabling shall not share pathways with backbone fiber cabling or any horizontal cable unless approved in advance by the Cal Poly ITS Telecomm group. C. Backbone copper cabling shall be installed point to point. Terminating a subgroup of conductors from a cable within a conduit and continuing to another location shall not be allowed. D. Absolutely no in-line splicing of backbone copper cabling shall be allowed. E. Contractor is to verify (in advance) sufficient end to end pathway fill ratios for cable runs prior to installation. F. No cross-connects shall be installed until after the backbone cable test reports have been reviewed and accepted by the Cal Poly ITS Telecomm group representative. All cross-connects shall typically be installed by the Cal Poly ITS Telecomm group. 3.02 QUANTITIES A. Quantities of system elements shown on the drawings are illustrative only and are meant to indicate the general configuration of the work. The Contractor shall be responsible for providing the correct quantities of materials to construct a system that meets the intent of these Specifications and the relevant codes. 3.03 INSTALLATION A. Cabling: 1. Unless otherwise noted, all backbone cables shall be routed through continuous conduit from point to point. 2. All backbone cable, once exposed, shall be provided with appropriate support. 3. At the same time cable is pulled into a conduit also install a pull rope to facilitate future cable pulls along those pathways. Pull rope shall be (minimum) nylon ¼ with 600 lb. pulling tension. 4. Cables running on ladder racking within an EF/TR/ER shall be neatly placed and lashed to the horizontal and vertical ladder racking with wire ties at every rung. B. Cable Terminations 1. All riser cables shall be punched down on 66 blocks in the EF/TR/ER. 2. Cable pair twists shall be maintained up to within 1/2 in. of the point of termination for backbone cables. For other backbone cables, maintain twists as close as practicable to the point Document Title 3 of 5

of termination. Under no circumstances shall cable pairs be untwisted or otherwise altered prior to termination. 3. All terminations shall follow industry standard uniform color codes. 3.04 GROUNDING & BONDING A. All termination locations for backbone copper cable shall bond the cable shield to the TGB/TMGB with a #6 AWG copper bonding conductor. B. Refer to Section 27-05-26 for additional details. 3.05 TESTING A. For testing details see Section 27-08-13 3.06 ACCEPTANCE A. Upon receipt of the Contractor s documentation of testing, the Cal Poly ITS Telecomm group representative shall review/observe the installation and may randomly request tests of the cables/wires installed. Once the installation and testing has been completed and the Cal Poly ITS Telecomm group representative is satisfied that all work is in accordance with the Contract Documents, the Cal Poly ITS Telecomm group representative shall notify the Contractor and/or Cal Poly Project Manager in writing or via email. 3.07 RECORD (AS-BUILT) DRAWINGS A. The Project Record Drawings shall show the types and locations of all backbone cabling. Drawings shall include identifying information from the cable identification labels. END OF SECTION Document Title 4 of 5

DOCUMENT VERSION CONTROL REVISION DATE AUTHOR REASON 1 02/20/2014 R. VOLK INITIAL DOCUMENT DEVELOPMENT 02/20/2014 DW & MH PRIMARY REVIEW COMPLETE Document Title 5 of 5