WATT TRANSDUCER. Instruction Manual

Similar documents
AUDIO SIGNAL CONVERTER

2.0 AC CIRCUITS 2.1 AC VOLTAGE AND CURRENT CALCULATIONS. ECE 4501 Power Systems Laboratory Manual Rev OBJECTIVE

+ 24V 3.3K - 1.5M. figure 01

McPherson Voltage Regulators 4501 NW 27 Ave Miami FL

Rotek AS440 compatible VOLTAGE REGULATOR (AVR)

Digital Multifunction Instrument - Rish Master 3440

Technical Data Sheet AMIK 300 / 301

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

Theta 20A / 20V. Technical Data Sheet. Special Features

Data Sheet. RISH Master Record %THD

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

AS440 AUTOMATIC VOLTAGE REGULATOR (AVR)

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

Technical Data Sheet

! CAUTION D TABLE 1

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

Contents. 1 Block Diagram. 2 Specifications. 3 Unipolar vs. Bipolar Interconnections. 4 Inexpensive Bipolar Power Supply Alternative.

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

CAH CARD. user leaflet. 1 of 15. Copyright Issue 12.1 January 2015

Thornwood Drive Operating Manual: Two-SCR General Purpose Gate Firing Board FCRO2100 Revision H

AMC-100 AMC-101 AMC-100 AMC-100B AMC-100D AMC-101 AMC-101B AMC-101D AMC-100A AMC-100C AMC-100E AMC-101A AMC-101C AMC-101E. AC Motor Controllers

658 Current to Position Converters

BE1-32R, BE1-32 O/U DIRECTIONAL POWER RELAY

Over or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors

INSTRUCTION MANUAL CLEVELAND-KIDDER TENSION INDICATOR SERIES AO REVISION

POWER SERIES Plus. Volt / Amp / Hertz. Digital Switchboard Meter. User s Manual IM2493VAF-3

ECE 2006 University of Minnesota Duluth Lab 11. AC Circuits

The answer is R= 471 ohms. So we can use a 470 ohm or the next higher one, a 560 ohm.

269 Troubleshooting Guide 11/4/98 1

AMC mA Positioner

PHASE CUT SIGNAL DRIVERS

Apitech Valve Drive Board

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

Know and understand you and your co-workers competence level before opening a live panel to diagnose

Application: Product Features: On site programmable PT/CT ratios: User selectable CT Secondary 5A/1A. User selectable PT Secondary

Exercise 2: Ohm s Law Circuit Current

P R O T R O N I X D i g i t a l P o w e r M e t e r M o d e l : A I n s t r u c t i o n M a n u a l

INSTALLATION & OPERATION MANUAL

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

T6+ Analog I/O Section. Installation booklet for part numbers: 5/4-80A-115 5/4-90A-115 5/4-80A /4-90A-1224

Model Operating Manual

Transformer Waveforms

Thornwood Drive Operating Manual: Six-SCR General Purpose Gate Firing Board FCOG6100 Revision R

ELKOR MOC1 TRANSDUCER SET - MANUAL

EE 448 Fall Lab Experiment No. 3 04/04/2008. Transformer Experiment

Paladin Transducers 250 Series Class 0.5 and Class 0.2

PART # mA Positioner

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

DLVP A OPERATOR S MANUAL

BC145 SIGNAL ISOLATOR BOARD

P o w e r. C O N T R O L S A N D a t h e n a c o n t r o l s. c o m. ATHENA CONTROLS, INC Campus Drive Plymouth Meeting, PA U.S.A.

SPECIFICATION, CONTROLS AND ACCESSORIES

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

Current Transformer Requirements for VA TECH Reyrolle ACP Relays. PREPARED BY:- A Allen... APPROVED :- B Watson...

Instructions AVC125-10: Voltage Regulator. Voltage Range. Maximum Continuous Burden. Voltage Range. Nominal Frequency

Line-to-line RMS Volts, 3 phases 4 digits (XXX.X) Volts

PHYS Contemporary Physics Laboratory Laboratory Exercise: LAB 01 Resistivity, Root-mean-square Voltage, Potentiometer (updated 1/25/2017)

TO BE DISCONTINUED 12/2016. FOR REPLACEMENT MODEL, CLICK HERE: NTM-D. D. C. SIGNAL POWERED FOR V, 4-20 & madc

7000 Series Bronze Globe Valves Two-Way Normally Open

Exercise 3: Ohm s Law Circuit Voltage

sch-remote.com EVOR04 Application note: Measure power

Operation and Maintenance Manual

ISOLATED AC/DC POWER SUPPLY

Technical Data Sheet. x1000. kwh R Y B

CLASS 200 EQUIPMENT EXCITATION SUPPORT SYSTEM

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

Module 1, Lesson 2 Introduction to electricity. Student. 45 minutes

not to be republished NCERT ALTERNATING CURRENT Chapter Seven MCQ 1

AMIK 200 / 201 Technical Data Sheet

OHIO SEMITRONICS, INC. DIGITAL AC POWER MONITOR OSI SPECIFICATIONS

USER'S GUIDE. Power Transducer WA / RA / WR. Review I

ULTRASTAB IHF Precision Current Transducer

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Arbiter Systems, Inc Vendels Circle, Suite 121 Paso Robles, CA USA

ULTRASTAB I U Precision

Product overview. Features. Product specifications. Order codes. 1kΩ Resistance Output Module

MODEL 421 Over/Under Motor Load Monitor

Theta Hz. Technical Data Sheet. Special Features

VOLTAGE REGULATOR R 449. Installation and maintenance. This manual must be sent to the end user R 449 X2 Z1 X1 Z2 E+ E- (12V - 10A)

CAT BOARD A CONTROL AND TRIGGER BOARD FOR 3-PHASE POWER SUPPLIES

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Data Sheet. Hall effect transducers, current and voltage

Transformer circuit calculations

This information is intended for use in the evaluations of applications for the Capstone Model C30 MicroTurbine.

Class 300 Equipment CBS 305, 320 Current Boost Systems FEATURES. DESCRIPTION Page 2. SPECIFICATIONS Pages 2 through 4.

ISSN: Page 298

Electro Controls. Input-Output Modules WattsIndustries.co.uk

DRG-SC Series Signal Conditioners

MULTI-OUTPUT DC REGULATED POWER SUPPLY

INSTRUCTIONS PS2500 POWER SUPPLY

Technical Service Bulletin DCX AGC Setup Procedure for MODAP Exciters

Fundamentals of Electric Circuits Chapter 2. Copyright The McGraw-Hill Companies, Inc. Permission required for reproduction or display.

Integra 1560 and 1580 Digital Transducer Systems

Load cell system fault finding guide (Application Note: Number AN1)

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)

Technical Service Bulletin DCX AGC Setup Procedure for ADAPT IV Exciters

3.0 CHARACTERISTICS. Type CKO Overcurrent Relay. switch, which allows the operation indicator target to drop.

Transcription:

WT 9200 WATT TRANSDUCER Instruction Manual IM-2 September 2003 USA: 6428 Ridglea Drive, Watauga, Texas 76148 Tel/Fax 1-817-427-2060/2067 E-mail: wes@westecinstruments.com

SPECIFICATIONS Power Supply Input Output Power Range 0 to 1000 Watts Nominal 3 Phase, 3 Wire, 120 V, 5 Amps per element or to customer requirements Input Voltage 0 to 120 Volts Nominal Potential Burden Approximately 0.25 VA @ 120 VAC Input Current 0 to 5 Amps Nominal Linear to 7.5 Amps Current Burden Approximately 0.02 VA Power Factor Range Unity to Zero Lead or Zero Lag Overloads Voltage: 200 Volts Maximum Current: 10 Amps Continuous 50 Amps for 10 Seconds 250 Amps for 1 Second Terminal Blocks 300 Volt Maximum Rating Current Voltage Special Standard: 4 20 ma into a maximum load of 750 Ω Optional: 0 10 VDC into a maximum load of 1000 Ω, with an external 450 Ω, ½ Watt, 1% resistor Optional Current or voltage outputs calibrated Note: Outputs are floating and either or neither side of the circuit may be grounded. Repeatability Linearity ± 0.1% of Full Scale ± 0.25% of Full Scale Temperature Recommended Permissible -4 F to +150 F (-20 C to +65 C) -40 F to +150 F (-40 C to +65 C) Note: The maximum effect on accuracy of the temperature variation limits above is above is ± 0.25% of full scale Dielectric Test 1500 Volts RMS Adjustments Zero Permits elevation or suppression of the Output Zero from 0 to ± 40% of full span Span Allows output full scale calibration from 0 to 250 through to 0 to 1040 watts total Damping Permits selection of the time required for the output to settle to a steady value after a change of input signal. Response Time: 0.25 seconds to 2 minutes.

DESCRIPTION The Model WT 9200 Watt Transducer is a device that converts AC voltage and current input signals into an analog DC output. The output from the transducer represents a measure of the true power consumed by the load. This is the solid state equivalent of the two wattmeter method of measurement of three-phase power. The output is either a current or voltage signal which is proportional to the true RMS power consumed by the load. True RMS Power is denoted by VA cos ø. Due to the solid state design the WT 9200 Watt Transducer has long life, low power burden and high accuracy in the presence of waveform distortion. Model WT9212 is available with a current output signal of 4 20 madc. Model WT9216 is available with a voltage output of 0 10 VDC. Model WT9210 units are specially calibrated to customer specifications as required. The output can be adjusted for full scale with an input of 0 250 through 0 1040 total watts of 3 phase, 3 wire power. This is equivalent to a maximum of 125 520 watts per element. It should be noted that single phase watts per element are used to calibrate the transducer at full scale and calibrated watts should be within the specification limits. The calibration formula is: Calibration Watts per Element = Full Scale Watts (CT Ratio) x (PT Ratio) x 2

INSTALLATION The Watt Transducer is normally mounted on a vertical surface using the mounting hole dimensions shown in drawing 1-9501112Z-DU-A. This connection should be studied carefully prior to installing, operating or servicing this equipment. Drawing 1-9501112Z-DU-A must be followed exactly when making interconnections with auxiliary equipment. Normal installation and wiring practices, which are adequate for low level signal cables, should be followed for output wiring from the transducer. It is recommended that output signal wiring be kept separated from the power cables. Wiring connections are required for four input signals. Two signals are from Potential Transformers (PT s) and two are from Current Transformers (CT s). Note: Wiring for input signals and the power supply should be in accordance with local requirements and standard practices. The two Potential Transformers are required to have a secondary voltage of 120 VAC for rated line to line primary input voltage. The secondary connections are made to terminals 1, 2, 3 & 4 as shown in drawing 1-9501112Z-DU-A. When measuring 3 phase power the maximum burden is approximately 0.25 VA. The two Current Transformers are required to have a secondary current of 5 Amps for maximum rated primary current. The secondary connections are to be made to terminals 5, 6, 7 & 8 as per drawing 1-9501112Z-DU-A. When measuring 3 phase power, the maximum burden is approximately 0.02 VA. Caution: Never energize a current transformer with the secondary circuit open. Input overloads to the transducer may damage unprotected auxiliary equipment.

CALIBRATION PROCEDURE The Model WT 9212 Watt Transducer is normally calibrated for 0 500 watts per element, which is equivalent to 0 1000 watts of three phase power. This calibration produces an output of 4 ma at 0 watts and 20 ma at 500 watts per element. Specially calibrated units are available to meet customer s specifications as required. These units have the watts per element rating recorded on the calibration plate. The procedure for checking or changing the calibration on Model WT 9212 is as follows: A) Determine the existing calibration from the nameplate or by use of the formula: Calibration Watts per Element = Full Scale Watts (CT Ratio) x (PT Ratio) x 2 B) Connect a single phase wattmeter and a load to the transducer. See drawing 1-9501111Z-DU-A for method of connections. C) Adjust the Damping potentiometer fully counterclockwise to the Fast Response setting. D) Adjust the load to 0 watts on the wattmeter. Then adjust the Zero potentiometer for 4 20 madc output. E) Adjust the load for the calibration watts on the wattmeter. Adjust the Span potentiometer for 4 20 madc output. F) Repeat steps D and E to confirm the adjustments. Check for linearity. G) When the calibration is satisfactory, adjust the Damping potentiometer clockwise to suit the requirements.

CALIBRATION NOTES 1) Model WT 9212 may be calibrated with 4 ma output equal to 40% of the watts at 20 ma output. Modify step D as required. 2) For negative watts, all connections to the potential input terminals must be reversed during calibration. This requires interchanging terminal 1 with 2 and terminal 3 with 4. After calibration return connections to the original locations. 3) Calibration for Model WT 9210 follows the above procedure except outputs are modified to meet the unit calibration specifications. 4) Model WT 9216 calibration is as above with step D adjustment at 0 V and step E adjustment at 10 V. 5) Span calibration setting may be at any level from 125 600 watts. Settings above 520 watts, however, are in excess of the normal ratings of the potential and current transformers and should only be used to indicate overload conditions. Should it not be possible to select a calibration within the rating limits, contact Westec for assistance. A typical wattage calculation is: Maximum Calibration Watts = 120V x 5A x Square Root of 3 = 1040 watts (3 Phase) 1040 Watts (3 Phase) 2 = 520 watts per element

LINE PT'S 1 2 3 9 10 11 L N G 115 VAC 50/60 HZ (4VA) CT 4 5 6 ZERO SPAN DAMP 12 13 14 SPARE LOAD + - CURRENT OUTPUT CT 7 8 15 16 VOLTAGE OUTPUT CONNECT AS SHOWN LOAD (NOTE 4.) Notes: 1. PT's: 120v. Secondary Burden 0.25va CT's: 0-5A. Secondary Burden 0.02va 2. All wiring, PT's & CT's by customer. 3. Either current or voltage output is available. The output may be zero based or with an offset zero. 4. CT & PT grounding optional. CURRENT MAX. RESISTOR "R" CALIBRATION RANGE LOAD TERM. 13 & 14 4-20 ma 750 ohm None Standard VOLTAGE MIN. RANGE LOAD 450 ohm 0-10 volts 1000 ohm 0.5 watt, 1% Optional 13 14 15 16 + - "R" VOLTAGE OUTPUT NO. DESCRIPTION DATE REVISIONS NTS WWC 01/01/01 WT 9200 WATT TRANSDUCER WWC 01/02/01 WIRING DIAGRAM WWC 01/02/01 1 1 SCALE DATE TITLE DRAWN FILE DRAWING NUMBER REV CHECKED PLOT 1 = 1 1-9501112Z-DU-A APPROVED JOB NO. SHEET OF 0

2 8 2 5 WATT METER 1 2 3 9 10 11 L N G 115 VAC 50/60 HZ 4 VA 25-120 ohm 1000 watt for 5 A 200 watt for 1 A or switch in light bulb's in parallel 4 5 6 7 8 ZERO SPAN DAMP 12 13 14 15 16 + - CURRENT OUTPUT 1 8 8 8 ma METER + - NO. DESCRIPTION DATE REVISIONS NTS WWC 01/01/01 WT 9200 WATT TRANSDUCER WWC 01/02/01 CALIBRATION CONNECTION DIAGRAM WWC 01/02/01 SCALE DATE TITLE DRAWN FILE DRAWING NUMBER REV CHECKED PLOT 1 = 1 1-9501111Z-DU-A APPROVED JOB NO. SHEET 1 OF 1 0

NO. DESCRIPTION DATE REVISIONS NTS WWC 01/01/01 WT 9200 WATT TRANSDUCER WWC 01/02/01 DIMENSIONS 1-9501113Z-DU-1 WWC 01/02/01 1 1 SCALE DATE TITLE DRAWN FILE DRAWING NUMBER REV CHECKED PLOT 1 = 1 APPROVED JOB NO. SHEET OF 0