TEKSCOPE MICROSCOPE. Models N2 Series USER S MANUAL

Similar documents
Biological Microscope Manual

TABLE OF CONTENTS. Safety notes i. Care and Maintenance. ii. 1. Components Illustration Installation of Components.. 4

OMM300. Inverted Metallurgical Microscope

STEINDORFF NYMC Polarizing Microscope

Zoom Stereo Microscope NYMCS-360 Instruction Manual

User Manual. Trinocular Metallurgical Microscope. MicroscopeNet.com

Manual for BMS E1 eplan series, compound microscope

OM FL400. Reflected Light Fluorescence Microscope. Instruction Manual. Please read instructions carefully before using microscope.

User Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com

Compound Microscopes Instruction Manual

Biological Microscope

User Manual. Trinocular Infinity Compound LED Microscope. MicroscopeNet.com

ML7520 ML7530 DIOPTER ADJUSTMENT RING BINOCULAR BODY, INCLINED 30. (a) Field Iris Control Lever. (c) Filter Slots EYEPIECES, KHW10X

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Therefore, all descriptions and illustrations in this instruction manual, including all specifications are subject to change without notice.

STEINDORFF Digital LCD Biological Microscope

Ⅰ. Application. Ⅱ. Main Technical Specification. AS1 Biological microscope,which is widely used in medical and

MANUAL MICROSCOPE SERIES. 73 Mall Drive, Commack, NY (P) (F)

User instructions Metallurgical microscope

User instructions Transmitted light laboratory microscope

SWIFT SERIES M2252DGL MICROSCOPE

STEINDORFF METALLURGICAL MICROSCOPE. NYMCS-620 Instruction Manual

User instructions Compound laboratory microscope

User instructions Metallurgical inverted microscope

User instructions Compound laboratory microscope

User Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com

Eyepieces KHW10X. Diopter Adjustment Ring. Binocular Body Inclined 30. Binocular Clamp Screw. Analyzer control Lever. Reflected Light Illuminator

Instruction Manual T Binocular Acromat Research Scope T Trinocular Acromat Research Scope

User instructions Transmitted light phase contrast microscope

MANUAL EXC-350 MICROSCOPE SERIES

Components of the Microscope

Therefore, all descriptions and illustrations in this instruction manual, including all specifications are subject to change without notice.

XSP-100XSP-100SM/ OF BIOLOGICAL MICROSCOPE OPERATION MANUAL READ THIS MANUAL BEFORE USING THE MICROSCOPE

User instructions Transmitted light laboratory microscope (digital)

STEINDORFF. Inverted Fluorescence Microscope NYMCS-702. Instruction Manual

User instructions Biological inverted microscope

STEINDORFF NYMC C. Comparison Microscope. Operating Instructions. A. Features and Functions

MANUAL EXM-150 MICROSCOPE SERIES

MANUAL EXC-400 MICROSCOPE SERIES. 73 Mall Drive, Commack, NY (P) (F)

User instructions Polarisation microscope

Swift M2252DGL Series Microscope Use and Care Manual

Microlux IV COMPOUND MICROSCOPE USER S MANUAL

MANUAL EXC-500 MICROSCOPE SERIES. 73 Mall Drive, Commack, NY (P) (F)

Microlux IV - LED COMPOUND MICROSCOPE USER S MANUAL

Swift M10 Series Microscope Use and Care Manual

Instruction Manual English Motic Incorporation Ltd.

Swift M3600, M3700 Series Digital & Compound Microscope

Swift M2250 Series Microscope Care and Use Manual

Therefore, all descriptions and illustrations in this instruction manual, including all specifications are subject to change without notice.

CALIBRATION OF MICROSCOPE EYEPIECE GRATICULE

Microscopes. A guide to use, general Maintenance, and repair tailored to the Olympus CX-21 microscope

Advanced Polarising Microscope Operating Instructions

Match the microscope structures given in the left column with the statements in the right column that identify or describe them.

Lx 500 User Manual. Research Microscopy Lx 500 Issue 1.3

MANUAL EXI-300 INVERTED MICROSCOPE SERIES. 73 Mall Drive, Commack, NY (P) (F)

Marine Invertebrate Zoology Microscope Introduction

Swift M10D Series Microscope Use and Care Manual

Laboratory Introduction

A BRIEF INTRODUCTION TO MICROSCOPY The two key properties of a microscope that allow you to see microbes are resolution and magnification.

Polarizing Microscope BA310 POL. Instructions

Easy Kohler Illumination Method

Biology 29 Cell Structure and Function Spring, 2009 Springer LABORATORY 1: THE LIGHT MICROSCOPE

Epi-LED FL Fluorescence Microscope Instruction Manual

MICROSCOPE LAB. Resolving Power How well specimen detail is preserved during the magnifying process.

CLEANING FOR BETTER OBSERVATION AND PHOTOMICROGRAPHY

Basic Microscopy. OBJECTIVES After completing this exercise, you should be able to do the following:

Therefore, all descriptions and illustrations in this instruction manual, including all specifications are subject to change without notice.

Nikon Ti-E Microscope Manual. Rightmire Hall Ohio State University. Director: Tony Brown Rightmire

XDS-3FL OPERATION MANUAL I T A L Y. Ver OPTIKA MICROSCOPES - ITALY -

BA410E Series Biological Microscope Instruction Manual

Lab: The Compound Microscope

Microbiology Laboratory 2

Visual Anatomy ansd Physiology Lab Manual Pig Version 2nd Edition Sarikas TEST BANK

What is it? Study the mystery photos and try to identify each one! Have access to a computer?

MICROSCOPY MICROSCOPE TERMINOLOGY

EXERCISE 3 The Microscope

Microscopy. Danil Hammoudi.MD

Ocular Lenses. Head. Arm. Objective Lenses. Slide Holder Stage. On / Off Switch. Condenser with Iris Diaphragm. Light Intensity Control

Biological Microscope. Biological Microscope ECLIPSE E100

H S P. User Manual. Cat.-No

10. Power Cord 8. Base

Name: Date Completed: Class: Lab Minutes: Teacher:

The microscope is useful in making observations and collecting data in scientific experiments. Microscopy involves three basic concepts:

Using a Compound Light Microscope

Basic Microscopy for Plant Biology

Introduction. Laboratory Equipment & Supplies. Model 1333PHi Shown (Phase Contrast) (2) Eyepieces (Eyecups installed) Diopter Adjustment Mechanism

BA310POL ADVANCED POLARIZATION MICROSCOPE

Introduction. Instructional Objectives. Materials. Procedure. I. Microscope Parts and Function. Honors Biology

Care and Use of the Compound Light Microscope

AMCON LENSOMETER USER S MANUAL EQ Fax

CAPTURING IMAGES ON THE HIGH-MAGNIFICATION MICROSCOPE

PROPER USE OF LAB EQUIPMENT and DATA ANALYSIS SKILLS

King Saud University Dept. of Bot. & Microbiology. General Microbiology 140 MIC

The invention of the microscope made it possible for scientists to view and study cells. Cells the basic units of all living organisms.

Ophthalmic Slit-lamp Microscope (SLM 1ER) Operation. Instruction

O P E R A T I N G I N S T R U C T I O N S

The light microscope

Chapter 2 Alignment C. Robert Bagnell, Jr., Ph.D., 2012

MICROSCOPE (3 x 2 hour lesson)

Introduction to Microscopes

Transcription:

TEKSCOPE MICROSCOPE Models N2 Series USER S MANUAL

Contents Before use 1 1.Nomenclature. 2 2.Operation 4 2-1 Angle of observation.. 4 2-2 Set the specimen slide.. 4 2-3 Set illumination 4 2-4 Adjust focus 4 2-5 Adjust diopter of binocular head 5 2-6 Adjust condenser 5 2-7 Adjust diaphragm 5 2-8 Choose the objective 5 2-9 Change the lamp 6 3.General specification. 7

4.Configuration drawing.. 8 5.Parameter/technical terms.. 9 6.Troubleshooting 11 Before use 1 Operation (1) As the microscope is a precision instrument, always handle it with care, avoiding impact or abrupt movement during transportation. (2) Do not let the microscope emerge in the sun directly. Keep it in a dry and clean place. Avoid high temperature and acute shake. Following environment is required: Indoor temperature: 0 ~40, Max relative humidity: 85%. (3) Avoiding impact the definition of the image, do not leave feculence or fingerprints on the lens surfaces. (4) Before using, examine to ensure the power supply voltage is consistent with the rating voltage. 2 Maintenance

(1) All glass surfaces must always be kept clean. Fine dust on the optical surface should be blown off by means of a hand blower or gently wiped off with a soft lens tissue. Carefully wipe off oil or fingerprints on the lens surfaces with tissue moistened with a small amount of 3:7 mixture of alcohol and ether. (2) Do not use organic solution to wipe the surface of the other components. These parts, especially the plastic parts, should be cleaned with a neutral detergent. (3) Do not take down or assemble it yourself. (4) After use, cover the microscope with the dustcover provided, and keep it in a dry and clean place for preventing rust. 1. Nomenclature

2.Operation The microscope is housed in a molded styrofoam container.

First take the container out of the carton, and lay the container on its side. Open the container carefully and don t let the optical items drop down, avoiding them being damaged. Check carefully to ensure the arm and accessories are well. Second put the monocular head or binocular head onto the top of the arm, and tighten the head-lock-screw. Install the objective into the microscope nosepiece from the lowest magnification to the highest, in a clockwise direction from the rear. Insert the eyepiece into the eyepiece tube. 2-1 Angle of observation Loosen the head-lock-screw and turn the monocular head or binocular head to a comfortable position for observation. Then lock the head-lock-screw. 2-2 Set the specimen slide Place a specimen to be studied on a glass slide, and fix it by the slide-holders of the mechanical stage. Turn the stage knob to make certain that the specimen is centered over the stage opening. 2-3 Set illumination For the microscope only with mirror, turn the mirror to get the field of view illuminated. For the microscope with built-in electrical illuminator, insert the plug of the main cable into the power socket and turn on the power switch to get the specimen illuminated. Then turn the brightness-adjustmentknob slowly to get the brightness suitable. 2-4 Adjust focus Loosen the limit-stop-knob, and adjust the coarse-focusingknob to bring the slide into focus. Then lock the limit-stopknob to avoid impact between the objective and slide. Adjust the fine focusing knob

2.Operation to get the image clear. For binocular head microscope, we also should do some more adjustments: (1)Hold the two ends of the head-cover and adjust the interpupillary distance by pushing or pulling the cover, until one circle of light can be seen. (2)After finishing the interpupillary adjustment, look at the graduation value in the middle of the head-cover. Turn the two diopter-ring and aim the same graduation value at the graduation line on the eyetube. Avoiding decline of the stage, rotate the tension knob in a clockwise direction to give a suitable force to the stage. If we need to reduce the tension, rotate the tension knob in an anti-clockwise direction. 2-5 Adjust diopter of binocular head If the diopter of the two eyes is not same, binocular head microscope has compensating function. Turn the nosepiece to choose the objective 4X, and use the left eye to observe the left eyepiece. Adjust fine-focusingknob and focus correctly. Use right eye to observe the right eyepiece. Gain the clear image by turning the diopter-ring up and down. 2-6 Adjust condenser Turn the condenser-adjustment-knob to make the condenser move up or down to concentrate light and to get the image brightness suitable for observation. 2-7 Adjust diaphragm Adjust the aperture of the iris diaphragm to get the background brightness suitable.

2-8 Choose the objective Turn the nosepiece to choose the objective. The objective selected should be set vertically right to the slide. Generally, first use the 2.Operation objective 4X to focus to reveal general structural image. Then use the higher power objective to reveal smaller details. When using the oil objective 100XR, a little of immersion oil must be put between the objective and the cover glass. 2-9 Change the lamp or put on the mirror Before changing the lamp, first pull the plug out off the electrical socket and wait for a while until the lamp cools down to avoid being burnt. Loosen the door-screw on the bottom to open the small door. Then you can see the lamp and lamp holder. Pull the lamp out and insert a new one into the holder. Close the door by tightening the screw. While changing the mirror, screw off the base-lens or mirror and screw on a new mirror.

Install Model Parts Specifications N2-1A N2-1A- N2-1A- EC300 EC500 Digital EC300 digital camera camera EC500 digital camera WF10X/18mm (x2) (x2) (x2) WF eyepiece 195 objectives 45 viewing head Coaxial focusing system WF10X/18mm with pointer WF10X/18mm with reticle WF15X/13mm WF20X/10mm (x2) (x2) (x2) 4X/0.10 10X/0.25 40XS/0.65 60XS/0.85 100XS/1.25(oil) Monocular head 360 rotating Binocular head 360 rotating Trinocular head 360 rotating The arm stand with ascending and descending stage Triple nosepiece Nosepiece Quadruple nosepiece Built in mechanical stage 130mmX140 Stage mm(moving range:50mmx76mm) Condenser AbbeN.A.1.25 Diaphragm Iris diaphragm Built in halogen illuminator with a Light continuous adjustment of brightness ф50mm mirror Lamp LED Filter blue 3.General specifications

N2 Series Biological Microscope general specifications (For option) 4.Configuration drawing eries Biological Microscope guration drawing EWF10X18 EWF10X18p EWF15X16 EWF20X10 EP5 EP10 EP16 OP100s OP40s OP10 OP4 OA100s OA60s XSGCD1.25(XSPID) XS GNI XS VIDEO CCD

5.Parameter/technical terms 5-1 Objective Type DIN achromatic objective 195mm Plan objective 195mm Magnification Numerical aperture( N.A) Medium Parfocal distance (mm) Magnificati on market (color ring) 4X 0.10 Air 45 Red 10X 0.25 Air 45 Yellow 40X 0.65 Air 45 Light blue 60X 0.85 Air 45 Deep blue 100X 1.25 Cedar oil 45 White 4X 0.10 Air 45 Red 10X 0.25 Air 45 Yellow 40X 0.65 Air 45 Light blue 100X 1.25 Cedar oil 45 White 5-2Eyepiece Type Wide field eyepiece Plan eyepiece Magnification 10X 15X 20X 5X 10X 16X Field of view(mm) ф18 ф13 ф11 ф18 ф18 ф15 5-3Electrics

The electrics are assembled according to customer s order. There are two kinds for option. 220V~240V power supply : 220V~240V±10%, 50/60Hz Lamp: 6V/20W Halogen lamp The electrics have gained the CE and GS certification. 100V~120V power supply : 100V~120V±10%, 50/60Hz Lamp: 6V/20W Halogen lamp The electrics have gained the UL certification. 5.Parameter/technical terms 5-4 Parameter (1) Total magnification: 20X~2000X (2) Field of view: ф0.8mm~ф4.5mm (3) Mechanical tube length: 160mm (4) Object to primary image distance: 195mm (5) Fine focusing sensitivity: 0.002mm 5-5 Technical terms (1) Total magnification=(magnification of objective) X (magnification of eyepiece) (2) Field of view=(line field of view of the eyepiece selected) (magnification of the objective selected) (3) N.A.=n sinα (max), N.A.is very important parameter which marks the features of the objective and condenser. The n is the refractive index of the medium (air or immersion oil) between the cover glass of the objective and the specimen. The α is the half of the aperture angle. The N.A.is bigger, the resolution of the objective is higher. (4) Object to primary image distance: the distance between the object plane to the primary image plane. The conjugate distance is fixed. (5) Mechanical tube length: The distance between the objective shoulder and the ocular shoulder.

6.Troubleshooting N2SERIES Symptom Cause Remedy Optics (1)The side of the field of view is dark or not even. (2)Stain or dust is observed in the field of view. (3)Unclear image (4)One side of the field of view is dark or the image moves while focusing. (5)The field of view is not bright enough. The nosepiece is not in the right position. Stain or dust has accumulated on the condenser, objective, eyepieces, base lens.. Stains have accumulated on the specimen. Stains have accumulated on the lens. No cover glass on the specimen slide. The cover glass is not standard. The specimen faces down. The immersion oil has accumulated on the dry objective. The immersion oil is not used for oil objective 100XR. Air bubble in the immersion. Use wrong immersion oil. The aperture is not opened to correct size. Stain or dust has accumulated on the lens in the inlet of the head. The condenser is not in the right position. The specimen slide is not fixed. The nosepiece is not in the right position. The iris diaphragm is not big enough. The condenser is not in the right position. Stain or dust has accumulated on the condenser, objective, eyepieces, base lens. Turn the nosepiece into the right position. Clean the lens. Clean the specimen. Clean the lens. Add the cover glass. Use a standard cover glass with thickness 0.17mm. Make it face up. Clean thoroughly. Use immersion oil. Get rid of the air bubble. Use a correct one. Adjust the iris diaphragm. Clean the lens. Adjust the condenser. Fix with clips. Turn the nosepiece into the right position. Adjust the iris diaphragm. Adjust the condenser. Clean the lens.

6.Troubleshooting Symptom Cause Remedy Optics (6)The image color is not true. Mechanics (1)The image is not focused while using high power objective. (2)The objective touches the cover glass while turning the nosepiece. (3)Can not move the slide smoothly. (4)Focus-knob is not flexible. (5)The stage declines itself to make the image unclear. (6)When focusing up, the coarse-focusingknob can not rotate. Electrics The brightnessadjustmentknob is not in the right position. No filter is used. The cover glass faces down. The cover glass is not standard. The cover glass faces down. The cover glass is not standard. The slide is not fixed correctly. The movable specimen holder is not fixed properly. Tension knob is too tight. Tension knob is too loose. Limit-stop knob locked. Adjust the brightnessadjustment-knob. Use correct filter. Put the cover glass to face up. Use a standard cover glass with thickness 0.17mm. Put the cover glass to face up. Use a standard cover glass with thickness 0.17mm. Adjust it correctly. Tighten it. Loosen it a little. Tighten it a little. Loosen the limit-stop-knob and lock it after refocusing. No power supply. Check the connection of the power cable. (1)The bulb does not The bulb is not inserted work. correctly. Insert it correctly. The bulb burnt out. Replace it. The fuse burnt out. Replace it. (2)The bulb burnt out The voltage is too high. Use correct power supply. usually. Use a wrong bulb. Replace with a correct one.

6.Troubleshooting Symptom Cause Remedy Electrics (3)The fuse burnt out usually. (4)The bulb flickers or the brightness is not stable. The voltage is too high. The bulb will burn out soon. The wire doesn t connect all right. Use correct power supply. Replace with a new one. Connect correctly.