Low Voltage Alternators

Similar documents
R438 A.V.R. Installation and maintenance. This manual is to be given to. the end user CALL US TODAY POWER-58. SHOP ONLINE

TAL 049 Low Voltage Alternator - 4 pole

R448 & R448 V50 A.V.R.

TAL 047 Low Voltage Alternator - 4 pole

TAL 044 Low Voltage Alternator - 4 pole

LSA R & LSA H 49.1 Low Voltage Alternators - 4 pole

R448 & R448 V50 A.V.R. Installation and maintenance R 448 ST5 ST3 ST10. Armature + 6- Field X2 Z1 X1 Z2 E+ E- 0V Slow fuse 250V 10 A

VOLTAGE REGULATOR R 449. Installation and maintenance. This manual must be sent to the end user R 449 X2 Z1 X1 Z2 E+ E- (12V - 10A)

r 450 Installation and maintenance This manual is to be given to the end user R 450 VOLT. STAB. I EXC STAT. AREP PMG FUSIBLES / FUSES

R 450. AVRs. Installation and maintenance. This manual is to be given to. the end user R 450 VOLT. STAB. I EXC STAT. LEDS PMG

R438 A.V.R. R438. Installation and maintenance X2 Z1 X1 Z2 E+ E- 0V REQUEST A QUOTE

Low Voltage alternators - 4 pole LSA 47.2

Low Voltage alternators - 4 pole LSA 46.2

LSA Pole. R 726 Mains paralleling

R / 8000 RAPIDE FAST RAPIDE 3 PAHASES SENSING SHUNT / AREP SERIES PMG NORMAL NORMAL NORMAL NORMAL 5000 / 6000 LSA 46 / 47

PARTNER ALTERNATORS LSA 40-4 Pole

Time constants ( s ) Resistance. Other data - Class H /6600 V kva. Efficiencies ( % )(3 phase - Classe H V kva)

R450 T DETECT. 3 PH 3 PH. SENSING 7000 / 8000 RAPIDE FAST RAPIDE VOLTAGE 80V ~ 320V SHUNT / AREP SERIES PMG NORMAL NORMAL NORMAL NORMAL 5000 / 6000

PARTNER ALTERNATORS LSA Pole

D510 c Automatic Voltage Regulators (AVRs)

A.V.R. R250. Installation and maintenance R250 0V E+ E- VOLT STAB FREQ. & L.A.M. CONFIG. REQUEST A QUOTE

WDG 12 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 61 - Technical Data Sheet

WDG 51 - Technical Data Sheet

WDG 83 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 12 - Technical Data Sheet

X1 Z1 X2 Z2 B+ B- V = IV USB IW PID CAN-H CAN-L PT100/CTP DSP PT100 PT100 A.V.R. AI 1 AI 2 DI1 DI2 D510 C. Installation and maintenance

PI734F - Winding 07. Technical Data Sheet APPROVED DOCUMENT

PI734F - Winding 28. Technical Data Sheet APPROVED DOCUMENT

WDG 13 - Technical Data Sheet

WDG 07 - Technical Data Sheet

WDG 71 - Technical Data Sheet

PI734E - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734C - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734B - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734C - Technical Data Sheet

PM734D - Winding 312. Technical Data Sheet APPROVED DOCUMENT. Generator Solutions AS

Using the VR448 in place of the Marathon DVR 2000

PM734F - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734A - Technical Data Sheet

R180. AVRs. Installation and maintenance

PM734B - Technical Data Sheet. Generator Solutions AS

AGN 124 AVR Power Supplies

AGN 124 AVR Power Supplies

S4L1S-D4 Wdg.17 - Technical Data Sheet

S4L1D-G41 Wdg Technical Data Sheet

Excitation Systems RG3 - T4. Transistorized Excitation Systems for Synchronous Generators. Power Generation

D510 C A.V.R. Installation and maintenance D 510C W V U X2 Z1 X1 Z2 F+ F- + - L1 L2 U V W. Volt. Exc. Fault. Manu U = U. Power USB +10V - A 1 - A 2 -

Excitation Systems. Service Generators SIPOL. Transistorized Excitation Systems for Synchronous Generators. Power Generation

/ a. This manual is to be given to the end user. nxs/m. Nh6 OXZ. Pjl Servo gearboxes. Installation and maintenance

AGN 034 Alternator Reactance

AS440 AUTOMATIC VOLTAGE REGULATOR (AVR)

Application Guidance Notes: Technical Information from Cummins Generator Technologies

Permanent Magnet Generators (PMG)

Rotek AS440 compatible VOLTAGE REGULATOR (AVR)

Trouble Shooting MagnaPLUS / Mariner / Harsh Duty

R241 A. 400 Hz A.V.R. Installation and maintenance. This manual is to be given to. the end user C B. Air craft p

Excitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation

Spec Information. Reactances Per Unit Ohms

ALTERNATOR TECHNICAL DESCRIPTION 1. LSA 53.2 XL13 / 4p. Chargé d'affaire : Karthikeyan GN 1 Moteurs Leroy-Somer +33 (0) xx

D I G I T A L V O L T A G E R E G U L A T O R

R1 Q2 Q1 F2 F1 N A1 A2 FUSE V AC S UF OE SL UF OE R150 R150. AVRs. Installation and maintenance

ZITARES LCS Non-SELV, Constant current control gear, 1-channel, non-dimmable

Excitation systems and automatic voltage regulators

GENERATOR DATA JANUARY 30, 2015

S0L1-J1 - Technical Data Sheet

Low Pass Harmonic Filters

Functional Range. Synchronising Relay : UN1, FN2, SY1, SY/SP. C&S Protection & Control Ltd.

Application note. How to shed non-priority loads with a Compact NSX circuit breaker?

Option T2 Digital AVR: DEIF DVC Leroy Somer D510C Description of option Functional description

This manual is to be given to the end user Installation and maintenance

AGN 005 Fault Currents and Short Circuit Decrement Curves

N. TEST TEST DESCRIPTION

PI144H - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

ZITARES ICD SELV constant current control gear, 2-channel, dimm- and programmable

SPPA-E3000 Brushless Excitation System (BES, Type RG3)

EMI Installation Guidelines

ZITARES NCD 2 nd Generation Non-SELV, constant current control gear, 1-channel, dimmable

NTG MULTIFUNCTON GENERATOR PROTECTION RELAY. NTG-Slide

ZITARES CC Constant current control gear, 2-channel, dimmable

Thyricon Excitation System

Impact of transient saturation of Current Transformer during cyclic operations Analysis and Diagnosis

ZITARES NCD FX-30 Non-SELV (isolated), constant current control gear, 1-channel, dimmable

State of North Dakota Engineering data submittal Page 1 For interconnection of distributed generation to Otter Tail Power Company

ZITARES CCD 2 nd Generation SELV constant current control gear, 1-channel, dimm- and adjustable

N. TEST TEST DESCRIPTION

Circuit breakers for direct current applications

Orbital GFI Inverter Series

EN 50178, IEC

IRT Mini Evo. Technical Manual. quality IN MOTION. quality IN MOTION

Substation applications

Generator Advanced Concepts

SPECIFICATION, CONTROLS AND ACCESSORIES

Power factor correction and harmonic filtering. Automatic power factor regulators

Technical catalogue. Emax Low voltage air circuit-breakers. Hotline:

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

Single Phase Soft Starters

Transcription:

Low Voltage Alternators Excitation and regulation systems SHUNT - PMG - AREP

Low Volta SHUNT excitation for basic applications - The AVR power supply voltage is shunted on the alternator output terminals. - The voltage reference is shunted on the same output terminals. - The AVR generates and regulates the excitation current as a function of the alternator output voltage. The SHUNT system is extremely simple in its design and is ideal for basic applications. It cannot tolerate high overloads and does not offer a short-circuit capability. PMG excitation for demanding applications The main alternator is the same design as that used with SHUNT excitation. - The AVR power supply voltage is generated by a permanent magnet generator (PMG) which is mounted on the shaft extension behind the alternator. The PMG delivers constant voltage which is independent of the main alternator winding. - The voltage reference is shunted on the alternator output terminals. Whatever the load, the AVR therefore delivers an excitation current suitable for this load, depending on how the voltage reference changes. The PMG system therefore has a high overload capacity (load impact or starting electric motors) which can short-circuit (300% - 10 s) in order to provide discriminating protection: Voltage build-up is intrinsic because of the permanent magnets. It is particularly suitable for demanding applications. The PMG system improves the performance of a SHUNT system. AREP excitation for demanding applications/patented by Leroy-Somer The AVR power supply voltage comes from 2 independent auxiliary windings located in the main stator: - The voltage delivered by the first auxiliary winding H1 is proportional to the alternator output voltage (shunt characteristic). - The voltage delivered by the second auxiliary winding H3 is proportional to the current drawn by the alternator and is a function of the applied load (compound characteristic booster effect). - The resulting phase-to-phase voltage supplies power to the AVR. This power supply to the AVR power circuit is independent of the voltage sensing measured on the alternator output terminals. Therefore, the excitation current delivered by the AVR to the alternator exciter is independent of any voltage distortions (harmonics) due to the load. The AREP system gives the alternator a high overload capacity (load impact or starting electric motors) and a short-circuit capability (300% - 10 s) in order to provide discriminating protection: the alternator with AREP excitation is shorter than the one with PMG excitation. It is particularly suitable for demanding applications.

ge Alternators - Excitation and regulation sys Excitation system selection chart SHUNT AREP SHUNT + PMG Motor starting capacity Basic High High Short-circuit capability No 300%/10 s 300%/10 s Susceptibility to non-linear loads Maximum Minimum Minimum Number of components Minimum Minimum Maximum Possibility of conversion Yes (PMG) Yes (PMG) Yes (Shunt) Alternator length Minimum Minimum Maximum Price Stator design Standard Special Standard Voltage build-up Applications Residual magnetism (remanent) Basic backup Telecom Lifetime Optimal Optimal Residual magnetism (remanent) Marine, industry, construction, hospitals, banks, standard production Permanent magnets Marine, industry, construction, hospitals, banks, standard production Reduced: an additional turning part Voltage U (%) Un Permanent voltage drop 90% SHUNT AREP PMG 100% 200% 250% 300% Load as a % 180% Low overload High overload - Short-circuit Excitation system varies depending on the type of alternator Type of excitation SHUNT AREP PMG PMI* option option option *For better voltage build-up, permanent magnets are inserted in the the exciter poles (standard in 50.2, 52.3, 53.1 and 54).

tems Analog or digital voltage AVRs depending on customer requirements Leroy-Somer AVRs benefit from all Leroy-Somer s experience in the electronics field. They have been designed to comply with market requirements in terms of characteristics, performance, conformity with standards and reliability. Their main characteristics are as follows: - Simple, user-friendly user interfaces - Power switching transistor offers an optimum response to interference generated by distorting loads - Voltage regulation ±0.5% in steady state with rapid response time (< 500 ms) - Optimised mechanical design for resistance to vibration and harsh environments, with coated electronic circuits - Conformity with IEC 60034-1 and UL 508 Analog AVRs with digital regulation function R200 range for SHUNT excitation: simplicity itself - Single-phase voltage sensing - Underspeed protection by U/f (R220) or U/f and (R250) function R400 range for SHUNT, PMG and AREP excitation types: performance - Single-phase voltage sensing - Excitation ceiling setting - Underspeed protection by U/f and function - Parallel operation between alternators with CT - Parallel operation with the mains with CT and R726 module - Three-phase sensing in R450T version or with R731 module - Overload protection with R450 version Digital AVRs D500 range for SHUNT, PMG and AREP excitation types: performance - communication - EASYREG TM parameter-setting and supervision program with user-friendly interface - Single-phase or three-phase voltage sensing - Adjustable underspeed protection by adjustable U/f and function - Stator overvoltage protection - Built-in parallel operation between alternators and with the mains - Communication : USB serial, proprietary CAN, J1939 CAN - Diodes detection fault Systems that help take account of load impact/load shedding are built into Leroy-Somer AVRs U/f function - Load impacts taken into account - Instant response from the AVR below the underspeed threshold - Gradual voltage return to rated voltage Voltage UN Underspeed and Voltage P2 function - Load Acceptance Module - Reduction in voltage drop and duration of speed variation of the diesel engine - Possible increase in the applied load for the same speed variation - Adaptive tuning for load impacts > 60% 0.85 UN 0 U/f 48 or 57.5 Hz 50 or 60 Hz fc fn UN 0.9 0.8 0 Transient voltage drop with (U/f) without 1 s 2 s 3 s Time fn 0.9 0.8 0 Max. speed drop with without 1 s 2 s 3 s Time Comparison of U/f and system performance Load on the shaft (kw) Load shedding due to Variation in the load Time 0 1 s 2 s 3 s

Excitation and Regulation matched for optimised performance AVRs for SHUNT excitation Type of AVR R220 R250 R450** option option option option Digital D510C*** option* option option option option AVRs for PMG excitation Type of AVR R438 R450** option R449 Digital D510C*** option* option option option option option option option option option AVRs for AREP excitation Type of AVR R438 R450** option R449 Digital D510C*** option* option option option option option option option option option *mounted externally ** R450T optional for three-phase sensing *** parallel operation with mains included

www.emersonindustrial.com Emerson 2014. The information contained in this brochure is for guidance only and does not form part of any contract. The accuracy cannot be guaranteed as Emerson have an ongoing process of development and reserve the right to change the specification of their products without notice. Moteurs Leroy-Somer SAS. Headquarters: Bd Marcellin Leroy, CS 10015, 16915 Angoulême Cedex 9, France. Share Capital: 65 800 512, RCS Angoulême 338 567 258. 4124 en - 2015.06 / d