OCS 500N6F SERIES SIMULATOR FOR FAST AND SLOW DAMPED OSCILLATORY WAVES AND RINGWAVE

Similar documents
CWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W

UCS 500N5T SERIES MULTIFUNCTIONAL TESTGENERATOR FOR CONDUCTED TRANSIENTS (EFT/BURST, SURGE, TELECOM-SURGE & POWER FAIL) UP TO 5.

CWS 500N1.3 CONTINUOUS WAVE SIMULATOR, 80W

CTR2 / CTR2-AD CALIBRATION TARGET AND VERIFICATION ADAPTER FOR ESD

CWS 500N4 SIMULATOR FOR CONDUCTED, COMMON-MODE DISTURBANCES, AS PER IEC , IEC ANNEX C, 0HZ (DC) TO 165KHZ

VDS 200Q SERIES 4-QUADRANT VOLTAGE DROP SIMULATOR - BATTERY SIMULATOR AND DC VOLTAGE SOURCE

LD 200N LOAD DUMP GENERATOR WITH CLIPPING-MODULE

TRANSIENT EMISSION SET AUTOMOTIVE TRANSIENT EMISSION MEASUREMENTS AS PER ISO

LD 200N200 LOAD DUMP GENERATOR WITH CLIPPING-MODULE AND BATTERY SWITCH

COMPACT NX5 MULTIFUNCTIONAL TEST GENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 5.5 KV

COMPACT NX5 SERIES MULTIFUNCTIONAL TEST GENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 5.5 KV

CNV 504 / 508 T-SERIES COUPLING/DECOUPLING NETWORK FOR UNSHIELDED SYMMETRICAL INTERCONNECTION LINES (COMMUNICATION LINES)

COMPACT NX5 FIRST OF ITS KIND. SHOWS ITS TRUE COLORS. THINKS FOR ITSELF.

UCS 500N7 MULTIFUNCTIONAL TESTGENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 7KV

UCS 500N7.2 MULTIFUNCTIONAL TRANSIENT SIMULATOR FOR RENEWABLE ENERGY

CWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W

LD 200N200 LOAD DUMP GENERATOR WITH CLIPPING-MODULE AND BATTERY SWITCH

LOAD DUMP GENERATOR WITH CLIPPING-MODULE AND BATTERY SWITCH

DCD SR - SERIES COUPLING/DECOUPLING NETWORKS FOR UNSHIELDED UNSYMMETRICAL INTERCONNECTION LINES

DCD ST - SERIES COUPLING/DECOUPLING NETWORK FOR UNSHIELDED SYMMETRICAL INTERCONNECTION LINES (COMMUNICATION LINES)

LD 200N GENERATOR LOAD DUMP Z FUNKCJĄ "CLIP" - LD 200N

NETWAVE SERIES (3-PHASE) THREE-PHASE MULTIFUNCTIONAL AC/DC POWER SOURCES

CTR2 / CTR2-AD CALIBRATION TARGET AND VERIFICATION ADAPTER FOR ESD

CWS 500N4 SIMULATOR FOR CONDUCTED, COMMON-MODE DISTURBANCES, AS PER IEC , IEC ANNEX C, 0HZ (DC) TO 165KHZ

VDS 200Q SERIES 4-QUADRANT VOLTAGE DROP SIMULATOR - BATTERY SIMULATOR AND DC VOLTAGE SOURCE

TRANSIENT EMISSION SET AUTOMOTIVE TRANSIENT EMISSION MEASUREMENTS AS PER ISO

NETWAVE SERIES (3-PHASE) THREE-PHASE MULTIFUNCTIONAL AC/DC POWER SOURCES

NETWAVE SERIES (3-PHASE) THREE-PHASE MULTIFUNCTIONAL AC/DC POWER SOURCES

COMPACT NX5 SERIES MULTIFUNCTIONAL TEST GENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 5.5 KV

LD 200N. Advanced Test Equipment Rentals ATEC (2832) LOAD DUMP GENERATOR FOR TESTS ACCORDING TO...

NETWAVE SERIES (1-PHASE) PROGRAMOWALNE WIELOFUNKCYJNE ŹRÓDŁO AC/DC

LD 200N GENERATOR LOAD DUMP Z FUNKCJĄ "CLIP" - LD 200N

AMP 200N1 LOW FREQUENCY SIGNAL SOURCE DC (0HZ) TO 250KHZ, 800W

LD 200N100 GENERATOR LOAD DUMP Z FUNKCJĄ "CLIP" I ELEKTRONICZNYM PRZEŁĄCZNIKIEM BATERII

IEC Electrical fast transient / Burst immunity test

PURCHASE DIVISION DEPARTMENT QUALITY MANUAL Revision No. : 02 Issue No: : 2 Dt of Revision : Issue Dt. :

AMP 200N2 LF SIGNAL & AMPLIFIER DC (0HZ) TO 250 KHZ (500 KHZ) WITH 1,000 W

Advanced Test Equipment Rentals ATEC (2832)

Combination Wave Test System

Fast transient burst simulator

CS114 + CS115 + CS116

EMC PARTNER. DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing

Overcurrent Protection / 7SJ45

MILITARY & AEROSPACE TESTING

Technical Specification

Technical Specification

Immunity Testing for the CE Mark

CONDUCTED IMMUNITY EMC TEST SYSTEM

5080A Multi-Product Calibrator

Insulation Test System

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AMETEK CO., LTD. NAGOYA OFFICE. (Main Laboratory) Onna, Atsugi-shi, Kanagawa-ken, Japan

Insulation Test System

2520 Pulsed Laser Diode Test System

EMC standards. Presented by: Karim Loukil & Kaïs Siala

Fast Transient / Burst Simulator

PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks

Fluke 5820A Oscilloscope Calibrator Specifications

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

THE MODULAR SOLUTION FOR 6 KV APPLICATIONS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Surge Generator for MIL-STD 1275

Programmable Pulse Generators PSPL10050A, PSPL10060A, PSPL10070A Datasheet

AC/DC Power Sources ACS Series

Power Analyser AM-10-PA2

Conducted Immunity Testing

AC/DC Power Sources ACS Series

Schlöder GmbH - EMC Test and Measurement Systems Model #

PRODUCT DATA. Sound Intensity Calibrator Type 4297

DATA SHEET A Multimeter 5.5 Digit Dual Display, Benchtop DMM

Model 310H Fast 800V Pulse Generator

CAR - TEST - SYSTEM 14

Arbitrary power supplies. 160 W to 5200 W

Tektronix: Products > AWG 2040 Arbitrary Waveform Generator

Moving Test - MT3000

Power Sensors Ltd. PQube 3 AC Analyzer IEC Class 0,2 S Accuracy Compliance Report

California Instruments BPS Series kva V A / Phase. Overview. High Power AC Source. Expandable Power Levels.

Voltage Transient Emission Test

Network Analyzer for Low-, Medium- and High-Voltage Networks

Voltage dips short interruptions with PFS and Netwave

8588A Reference Multimeter

DECLARATION OF CONFORMITY

Novità sulla IEC ; -10; -12

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

SECULIFE SR PC Controllable Instrument for Measuring Safety-Relevant Characteristic Values of Electrical Devices /2.

C.A Complete electrical network analysis at the tips of your fingers! Power Quality Monitor. Keeping up with the standards

NSG Hard keys for important functions. 5.7 color display, easy to use firmware. 3 power meter

RF Conducted Immunity and Automotive Transient Generator Test Systems

Agilent Technologies 8114A 100 V/2 A Programmable Pulse Generator

SWT 3000 Teleprotection technical data siemens.com

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price

Introduction EMC. Filter parameters. Definition of EMC / EMI. X-Capacitor. Sources of EMI. Coupling mechanism. Y-Capacitor.

LCR Meter. Product Specification

SDM3045X Digital Multimeter. DataSheet

AMP 200N2 LF SIGNAL & AMPLIFIER DC (0HZ) TO 500 KHZ WITH 1,000 W

TesT system for ConduCTed and radiated immunity

N. TEST TEST DESCRIPTION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Low Frequency Measuring System

Model 865 RF / Ultra Low Noise Microwave Signal Generator

8558A 8 1/2 Digit Multimeter

Transcription:

OCS 500N6F SERIES SIMULATOR FOR FAST AND SLOW DAMPED OSCILLATORY WAVES AND RINGWAVE FOR TESTS ACCORDING TO... > ANSI/IEEE C37.90 > ANSI/IEEE C62.41 > EN 61000-4-10 > EN 61000-4-12 > EN 61000-4-18 > IEC 60255-22-1 > IEC 60255-26 > IEC 61000-4-10 > IEC 61000-4-12 > IEC 61000-4-18 > IEC 61000-6-5 > IEC 61850-3 > IEC 62052-11 OCS 500N6FX - COMPACT TESTERS FOR FAST/SLOW DAMPED OSCILLATORY WAVES AND RINGWAVE The OCS 500N6F series includes the test capabilities for fast damped oscillatory waves at 3 MHz, 10 MHz and 30 MHz up to 4.4kV and is extendable for slow damped oscillatory waves at 100 khz / 1 MHz up to 3.0 kv (as per EN/IEC 61000-4-18) and for ringwave up to 6 kv as per EN/IEC 61000-4-12. Damped Oscillatory Waves are repetitive transients mainly occurring in power, control and signal cables installed in high voltage and medium voltage stations, divided into slow and fast damped oscillatory waves. The Ringwave is a non-repetitive damped oscillatory transient occurring in low-voltage power, control and signal lines supplied by public and non-public networks. HIGHLIGHTS > Fully automated single box test system APPLICATION AREAS INDUSTRY RESIDENTIAL > Fast Damped Oscillatory Waves up to 4.4 kv COMPONENTS RENEWABLE ENERGY > Slow Damped Oscillatory Waves up to 3 kv (option) MEDICAL > Single DUT port > Ringwave up to 6 kv (option) BROADCAST EM TEST > PAGE 1/8

MODEL SELECTION OPERATION THREE IN ONE - THE OCS 500N6F COMBINES DAMPED OSCILLATORY WAVES AND RINGWAVE EASY TO OPERATE The basic equipment includes the fast damped oscillatory generator with 3 MHz, 10 MHz and 30 MHz for up to 4.4 kv acc. IEC 61000-4-18. The OCS 500N6F comes with a built-in coupling/ decoupling network for either single phase or three-phase and is rated for currents of 16 A or 32 A per line. Optional Modules: Slow Damped Oscillatory Waves with 100 khz / 1 MHz reach up to 3kV. The module comply with EN/IEC 61000-4-18 and also with the requirements to test protective relays as per ANSI/IEEE C39.70. Ringwave Module with capability of up to 6 kv complies with the Ringwave requirements of IEC 61000-4-12 ANSI/IEEE C62.41 standard. Front panel menu and function keys enable the user to program his test routines quickly and accurately. The cursor allows fast control of all test parameters of the programmed routine, thus test procedures are simplified and confidence is generated that every step is carried out correctly. The operating concept em.flow distinguished by the following benefits: > Extremely easy to operate > Parameters can be set even during the test > Quick start > Standard programs > User programs > Select directly from standard test levels > Statistical test options > Predefined tests EM TEST > PAGE 2/8

SOFTWARE AUXILIARY DEVICES IEC.CONTROL SOFTWARE FOR CONTROL AND DOCUMENTATION CNV 504N4/N5 SERIE - COUPLING NETWORK FOR SIGNAL/DATA LINES Outstanding user convenience, clearly structured windows and operation features and the EM TEST standards library along with the flexibility to generate user specific test sequences very easily are the main features of iec.control software. The software is automatically configured according to the connected EM TEST generators. Extensive reporting capabilities help the user to create test reports that meet international requirements. iec.control is supported by Windows XP, Windows Vista, Windows 7 and Windows 8. Remote control is achieved either via opto-link or GPIB. iec.control supports a wide range of GPIB cards both of National Instruments. CNV 504N5.1 and CNV 504N5.3 The CNV 504N5-series coupling/decoupling networks are used to apply slow damped oscillatory waves with a frequency of 100 khz or 1 MHz onto signal/data lines in accordance to IEC/EN 61000-4-18. CNV 508N4 and CNV 508N4.1 The CNV 508N4 series are special coupling/decoupling networks being used to perform "Electrical disturbance tests for measuring relays and protection equipment" in accordance to IEC 60255-26. The coupling/decoupling network is equipped with 4-pairs (8 wires) for the application on to signal/data lines. EM TEST > PAGE 3/8

ACCESSORIES MS 100N - MAGNETIC FIELD COIL FOR DAMPED OSCILLATORY MAGNETIC FIELDS The MS 100N is a 1*1 sqm magnetic field coil as specified in IEC/EN 61000-4-10. Its design allows easy moving of the coil. The field coil is adjustable in height and allows for 360 degr rotation. The MS 100N is directly connected to the corresponding HV output of the OCS 500N6F to generate damped oscillatory magnetic fields as per IEC/EN 61000-4-10, up to level 5. MODEL OVERVIEW OCS 500N6F MAIN-UNIT MODELS OCS 500N6F AC 250 V / 16 A DC 250 V / 16 A OCS 500N6F.1 AC 250 V / 32 A DC 250 V / 32 A OCS 500N6F.2 AC 3x440 V / 16 A DC 250 V / 16 A OCS 500N6F.3 AC 3x440 V / 32 A DC 250 V / 32 A OCS 500N6F MODELS FOR RCCB TESTING OCS 500N6F.4 AC 3x440 V / 32 A DC 250 V / 32 A, calibration acc. IEC 61008-1 and IEC 61009-1 EM TEST > PAGE 4/8

FAST DAMPED OSCILLATORY MODULE SLOW DAMPED OSCILLATORY MODULE (OPTION) FAST DAMPED OSCILLATORY WAVES AS PER IEC/EN 61000-4-18 SLOW DAMPED OSCILLATORY WAVES AS PER IEC/EN 61000-4-18 (OPTION) Voltage (o.c.) at HV output 450 V - 4,400 V ±10% Voltage (o.c.) at HV output 250 V - 3,000 V ± 10% Rise time 5 ns ±30% 250 V - 2,500 V ± 10% Oscillation frequencies 3 MHz, 10 MHz and 30 MHz, ±10% Voltage (o.c) at line output Rise time 75 ns ± 20% Decaying Peak 5 to be > 50% of peak 1 value Peak 10 to be < 50% of peak 1 value Oscillation frequencies 100 khz and 1 MHz ± 10% Source impedance 50 ohm ±20% Decaying Coupling common mode Peak 5 to be > 50% of peak 1 value Peak 10 to be < 50% of peak 1 value Polarity Positive, negative Source impedance 200 ohm ± 20% Repetition rate Max. 5,000 /s ±10% Polarity Positive, negative Burst duration 50 ms ±20%, at 3 MHz 15 ms ±20%, at 10 MHz 5 ms ±20%, at 30 MHz Repetition rate Max. 50 /s for 100kHz and Max. 500 /s for 1MHz Burst duration At least 2 s Burst period 300 ms ±20% Short-circuit current 9 A - 88 A ±20% Rise time current waveform < 330 ns at 3 MHz < 100 ns at 10 MHz < 33 ns at 30 MHz RINGWAVE MODULE (OPTION) Decaying (current) Peak 5 to be > 25% of peak 1 value Peak 10 to be < 25% of peak 1 value RINGWAVE AS PER IEC/EN 61000-4-12 AND ANSI/IEEE C62.41 (OPTION) Voltage (o.c.) 250 V - 6,000 V ± 10% Rise time 0.5 us ± 30% Oscillation frequency 100 khz ± 10% Decaying Ratio of peak 2 to peak 1: 0.4-1.1 Ratio of peak 3 to peak 2: 0.4-0.8 Ratio of peak 4 to peak 3: 0.4-0.8 Source impedance 12 ohm and 30 ohm ± 20% Peak current (s.c.) Max. 500 A @ 12 ohm or Max. 200 A @ 30 ohm internally Rise time 0.2 us to 1.0 us Oscillation frequency 100 khz ± 10% Polarity Positive, negative Repetition rate 1 / min or faster EM TEST > PAGE 5/8

GENERAL SPECIFICATION GENERAL DATA TRIGGER CIRCUIT INTERFACE Release of pulses Automatic, manual, external Synchronization 0-360, resolution 1 Optical interface Opto link, 3 m cable USB A connector Parallel interface IEEE 488, addresses 1-30 OUTPUT Direct Via HV-safety lab connectors Coupling mode Line to line Line(s) to ground (PE) DUT supply OCS 500N6F AC: 250 V / 16 A; 50/60 Hz DC: 250 V / 16 A OCS 500N6F.1 AC: 250 V / 32 A; 50/60Hz DC: 250 V / 32 A OCS 500N6F.2 AC: 3x440 V / 16 A; 50/60 Hz DC: 250 V / 16 A OCS 500N6F.3 AC: 3x440 V / 32 A; 50/60 Hz DC: 250 V / 32 A OCS 500N6F.4 AC: 3x440 V / 32 A; 50/60 Hz DC: 250 V / 32 A CRO trigger 5V trigger signal for oscilloscope GENERAL DATA Dimensions, weight 19" / 9 HU, approx. 32 kg (1-phase) 19" / 9 HU, approx. 50 kg (3-phase) Supply voltage 115/230 V +10/-15% Fuses 2 x T2AT (230V); 2 x T4AT (115V) Temperature 10 C to 35 C Rel. humidity Max. 85%, non condensing Atmospheric pressure 86 kpa (860 mbar) to 106 kpa (1,060 mbar) MEASUREMENTS Ring wave Peak voltage and peak current in LCD TEST ROUTINES Quick Start Immediate start; easy-to-use and fast Standard Test routines As per IEC 61000-4-18 As per IEC 61000-4-12, Level 1-4 Manual Standard Test routine As per ANSI/IEEE C62.41 As per IEC 61000-4-10, Level 1-5 User Test routines Change polarity after n pulses Change coupling after n pulses Change voltage after n pulses Change phase angle after n pulses EM TEST > PAGE 6/8

OPTIONS ACCESSORIES COUPLING NETWORK CNV 504N5.1 Coupler for 4 signal/datalines for damped oscillatory waves 100kHz and 1MHz as per IEC 61000-4-18, 50 V/4A CNV 504N5.3 Coupler for 4 signal/datalines for damped oscillatory waves 100 khz and 1 MHz as per IEC 61000-4-18, 250 V / 4 A CNV 508N4 Coupler for 4 pairs (8 wires) as per IEC 60255-26, 250 V / 4 A CNV 508N4.1 Coupler for 4 pairs (8 wires) as per IEC 60255-26, 250 V / 16 A HFK Capacitive coupling clamp as per IEC 61000-4-4 MS 100N Magnetic Field coil for IEC/EN 61000-4-10 application ACCESSORIES SOFTWARE, VERIFICATION iec.control Remote control and documentation software with library of standards CA OCS F Kit Load resistor set for fast damped oscillatory wave verification, KW 0R1 load resistor 0.1ohm, KW 1000 load resistor 1000ohm, CA MC F Adapter to match KW 0R1 and KW 1000 to the supply output of the OCS 500N6F EM TEST > PAGE 7/8

COMPETENCE WHEREVER YOU ARE CONTACT EM TEST DIRECTLY Switzerland USA / Canada EM TEST (Switzerland) GmbH > Sternenhofstraße 15 > 4153 Reinach > Switzerland Phone +41 (0)61/7179191 > Fax +41 (0)61/7179199 Internet: www.emtest.ch > E-mail: sales.emtest@ametek.com AMETEK Compliance Test Solutions > 52 Mayfield Ave. > Edison > NJ 08837 Phone +1 (732) 417-0501 Internet: > E-mail: sales.emtest@ametek.com Germany AMETEK CTS Germany GmbH > Lünener Straße 211 > 59174 Kamen > Deutschland Phone +49 (0)2307/26070-0 > Fax +49 (0)2307/17050 Internet: > E-mail: info.cts@ametek.de France EM TEST FRANCE > Le Trident - Parc des Collines > Immeuble B1 - Etage 3 > 36, rue Paul Cézanne > 68200 Mulhouse > France Phone +33 (0)389 31 23 50 > Fax +33 (0)389 31 23 55 Internet: www.emtest.fr > E-mail: info@emtest.fr P.R. China E & S Test Technology Limited > Rm 913, Leftbank > No. 68 Bei Si Huan Xi Lu > Haidian District > Beijing 100080 > P.R. China Phone +86 (0)10 82 67 60 27 > Fax +86 (0)10 82 67 62 38 Internet: > E-mail: info@emtest.com.cn Republic of Korea EM TEST Korea Limited > #405 > WooYeon Plaza > #986-8 > YoungDeok-dong > Giheung-gu > Yongin-si > Gyeonggi-do > Korea Phone +82 (31) 216 8616 > Fax +82 (31) 216 8616 Internet: www.emtest.co.kr > E-mail: sales@emtest.co.kr Poland EM TEST Polska > ul. Ogrodowa 31/35, 00-893 Warszawa > Polska Phone +48 (0)518 64 35 12 Internet: /pl > E-mail: infopolska.emtest@ametek.com Information about scope of delivery, visual design and technical data correspond with the state of development at time of release. Subject to change without further notice. EM TEST > PAGE 8/8