CROSSBAR RAFTER ISOMETRIC

Similar documents
14000 I/O Series Flush Glaze. Fabrication and Installation Instructions

KS SERIES - VERTICAL INSTALLATION

Series Sloped glazed Curtain wall. Installation Instructions

GLOSSARY OF TERMS SECTION 8

KS42 MF SERIES - HORIZONTAL INSTALLATION

Door Canopy. PDL Building Products Industrial Parkway, N. Olmsted, OH Phone:

DW HORIZONTAL INSTALLATION

Illustration Part Description Base List Weight/ Ft./ Box Number Price/S.L. S.L. S.L. Qty.

GENERAL INSTALLATION GUIDELINES

YSG 40/50/50T Window Wall System Installation Manual

GENERAL INSTALLATION GUIDELINES

14000 Series. Fabrication and Installation Instructions

4500 Series. Fabrication and Installation Instructions

14000 Series. Fabrication and Installation Instructions

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL PIONEERING INSULATED METAL PANEL TECHNOLOGY

YWE 40 T Window Wall System Installation Manual

YES 600 Thermal Clip Storefront System Installation Manual

TABLE OF CONTENTS A-1

Installation Instructions

BuildingEnvelope Oldcastle ( ) -

Kocked Down with Ends Assembled

INSTALLATION INSTRUCTIONS

Storefront Installation Guide

900 SERIES WALL PANELS

YES 45 XT High Performance Thermal Storefront System

YCW 752 Outside Glazed Curtain Wall System Installation Manual

Flushglaze For Framed Openings and Horizontal Panels. Window System Installation Guide

40mm Thermoclick. Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial)

BuildingEnvelope Oldcastle ( ) -

BuildingEnvelope Oldcastle ( ) -

Single-Hung Windows Premium Atlantic Aluminum

YCW 750 OG Outside Glazed Curtain Wall System Installation Manual

SECTION SHEET METAL FLASHING AND TRIM

Extrusions POLYLOCK ATTACHING EXTRUSIONS

Series Advanced and alternate. Installation Instructions

INSTALLATION INSTRUCTIONS

VENTED GABLE DETAIL ROOF PANEL GABLE FLASHING 24" C/C MAX. BUTYL SEALANT TAPE ROOF PURLIN FLASH AB-1, AB-2, AB-3, OR AB-4


YES 45 TU Thermal Storefront System Installation Manual

STEVE ENNIS ARCHITECT 1108 EAST JACKSON STREET MEDFORD, OREGON 97504

400 SERIES VERTICAL INSTALLATION

BuildingEnvelope Oldcastle ( ) -

YES 40 FS/FI Storefront System Installation Manual

Ekoroof LiteTile Dimensions

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING

SEAL PLATE SP4413 VERTICAL SP4414 1"[25] VERT. PANEL JTS. 1/2"[13] INTERM. SPLICES DESIGN LOADS AND SLAB EDGE DISTANCES. 1 2 NOM.

DW VERTICAL INSTALLATION

Skypod. Pitched PVC-U skylights. Installation guide PITCHED PVC-U SKYLIGHTS ISSUE 1

Series Exterior glazed curtain wall. Installation Instructions

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

INSTALLATION INSTRUCTIONS 2 1/2 x 7 for 1 Glass

for Andersen 400 Series Woodwright Transom over 400 Series Woodwright Double-Hung or 400 Series Woodwright Picture Window

SERIES 4070-T GENERAL ASSEMBLY AND INSTALLATION INSTRUCTIONS

Skypod. Pitched PVC-U skylights. Installation guide PITCHED PVC-U SKYLIGHTS ISSUE 1

Skypod. Pitched PVC-U skylights. Installation guide PITCHED PVC-U SKYLIGHTS ISSUE 1

SolarMount (E)volution

Guardian ¾ Hip Ridge Skylight Installation Manual

YCW 750 OG Outside Glazed Curtain Wall System Installation Manual

INSTALLATION INSTRUCTIONS TRIFAB 451UT SCREW SPLINE ASSEMBLY TRIFAB 451UT. AUGUST, 2010 (Part No. 452T-CG-970) EC

SKIN SYSTEM ORDER FORM NOTES AND REQUIREMENTS

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! FEBRUARY 2012

Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.

NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING

INSTALLATION INSTRUCTIONS

YCW 750 IG Inside Glazed Curtain Wall System Installation Manual

Revision Date: April 01, Paramount Enclosure

SLATE & SHINGLE INSTALLATION

FG-5100T STORMMAX INSTALLATION AND GLAZING MANUAL NOTE:

WALL TO FABRICATED FLOOR

VENTED GABLE DETAIL ROOF PANEL GABLE FLASHING 24" C/C MAX. BUTYL SEALANT TAPE ROOF PURLIN FLASH AB-1, AB-2, AB-3, OR AB-4

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

BuildingEnvelope Oldcastle ( ) -

900 SERIES PANEL SHEET INDEX STAGGERED ENDLAP STAGGERED MALE LEG AT ENDLAP CONTINUOUS FEMALE ENDLAP INSTALLATION SEQUENCE CI-WR

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

Dear Contractor, I am glad that you are interested in our window rebate program.

TESTED FOR Report No. : A04H-009 Date : February 10, 2004 FLEETWOOD ALUMINUM PRODUCTS, INC. Page : 1 of Railroad Street Corona, CA 91720

Installation Guidelines

NEW skypod INSTALLATION GUIDE

INSTALLATION INSTRUCTIONS

Thermally Broken Framing and Door Installation

Installation Instructions

Pocket Door Installation Instructions

SHEET METAL FLASHING AND TRIM Christ on the Mountain

TIOGA Table of Contents

Table of Contents Light Gauge Metal Roof & Wall Panels

WINDOW REPLACEMENT INSTRUCTIONS FOR CASEMENT, DOUBLE-HUNG AND CLAD FRAME WINDOWS USING FRAME SCREWS

Installation Guide for Andersen Architectural Clad Inswing Entry and Patio Doors

INTEX Millwork Solutions SECTION EXTERIOR PVC PERGOLAS (IBC Compliant)

Vinyl Windows Manufactured by VPI Quality Windows

Architectural Testing AAMA 501 TEST REPORT. Report Number: C Rendered to: Tubelite, Inc. Walker, Michigan


GV Standard Sliding Over Roof Installation Instruction Manual

Installation Guide for Andersen 400 Series Tilt-Wash Transom and 200 Series Narroline Transom Windows

RELIANCE -LT INSTALLATION AND GLAZING MANUAL

PIVOT DOOR 3400P INSTALLATION INSTRUCTIONS

ULTRA WINDOW & DOOR EXPANDERS AND RECEIVERS INSTALLATION INSTRUCTIONS

ENGINEERING STRENGTH INSTAL L AT I O N M A NUAL OUR STRENGTH IS OUR STRENGTH

DESIGNER SERIES GUTTER SYSTEM INSTALLATION INSTRUCTIONS

UNIVERSAL BASES. #60UB - Universal Mounting Base. Same as above for 1/2 inside threads.

Vinyl Windows and Doors Manufactured by VPI Quality Windows

Transcription:

Super Sky Products' typical glazing system consists of glass panels or "lites" which are attached to the main framing members using extruded aluminum "retainers" or "pressure plates". These retainers are typically fastened to the main framing members with Torx fasteners, which are sealed with a vinyl washer and located at a maximum spacing of 12" on center. EPDM glazing gaskets separate the glass from the aluminum above and below. Retainers are then continuously wet-sealed in the field with high performance silicone sealant and covered with a finished aluminum "snap-on cap" extrusion to conceal the retainer fasteners. At horizontal framing members, the glass is retained to the frame by using structural silicone sealant joints between the glass edges and the crossrafter glass stop. This design creates a flush joint that eliminates water damming and debris build-up. A slide-in PVC glass stop is standard at this detail to reduce thermal transfer from exterior to interior. All crossrafter structural joints and continuous pressure plate weather seal joints are married together to create a complete water-tight installation. EXTR. ALUM. CAP EXTR. ALUM. RETAINER GLAZING STRIP FASTENERS SPACER BLOCK STRUCTURAL SEALANT BACKER ROD GLASS STOP SETTING BLOCK GLAZING STRIP RAFTER CROSSBAR EXTR. ALUM. CAP EXTR. ALUM. RETAINER GLAZING STRIP STRUCTURAL SEALANT GLASS STOP BACKER ROD GLAZING STRIP ISOMETRIC

Super Sky Products' total flush glazing system (TFG) is based on silicone sealant technology and uses unique continuous extruded aluminum retainers and intermittent hold-down clips for the attachment of the glass to the frame. The retainers are adhered to the glass using structural silicone sealant which is applied and cured in the glass fabricator's controlled factory environment. There are no exterior fasteners or aluminum caps beyond the glass surface, thereby providing a true thermal break system. Each lite is independent of its adjacent lites, and can be replaced without removal of others. The exterior weather seals are high performance silicone, which is applied after all lites have been secured. The entire exterior surface of the glass is one flat plane with no obstructions to dam water or cause dirt and debris build-up. SETTING BLOCK GLASS STOP RAFTER CROSSBAR 1 4" MACHINE SCREW EXTR. ALUM. RETAINER CLIP (SWIVEL) EXTR. ALUM. FACTORY APPLIED GLASS RETAINER CHANNEL EXTR. ALUM. FIELD INSTALLED RETAINER CLIP (SWIVEL) EXTR. ALUM. RAFTER ISOMETRIC EXTR. ALUM. CROSS RAFTER

SILL & HEADS assure proper perimeter interface with the adjacent construction, and are fitted with formed sheet metal flashing to provide a water tight condition between the skylight and the adjacent construction. Sill conditions are typically the low point for the skylight condensation guttering system and allow for evacuation of any potential condensation collection through the use of weep holes, which are shop located and drilled in the sill extrusion. Typically the weep holes are located at each rafter. GLASS EXTR. ALUM. SILL EXTR. ALUM. SELF- SILL BASE EXTR. ALUM. SILL WEEP HOLE SELF- SILL VARIABLE SILL GLASS STOP STRUCTURAL SEALANT EXTR. ALUM. CAP & RET. GLASS GLASS EXTR. ALUM. SILL WEEP HOLE EXTR. ALUM. SILL BASE ZEE-CLIP, IF REQ'D, BY ENGINEERING CROSS RAFTER SILL VARIABLE SILL w/ INSULATED CLOSURE

SILL & HEADS assure proper perimeter interface with the adjacent construction, and are fitted with formed sheet metal flashing to provide a water tight condition between the skylight and the adjacent construction. Sill conditions are typically the low point for the skylight condensation guttering system and allow for evacuation of any potential condensation collection through the use of weep holes, which are shop located and drilled in the curb extrusion. Typically the weep holes are located at each rafter. GLASS STRUCTURAL SEALANT FORMED ALUM. SILL EXTR. ALUM. ANGLE SETTING BLOCK LOW-PROFILE FORMED SILL ALUM. GLASS STOP SILL

SEALANT PRESSURE BAR FASTENER GLASS E5 BATT INSULATION E5 HEAD GLASS E5 HEAD GLASS E5 EXTR. ALUM. RAFTER SUPPORT HEAD

SUPPORT & MOUNTING methods are used to connect Super Sky extrusions to supporting structures when all aluminum structures may be impractical due to spanning length. Even with accurate support structures, the ability to level, adjust and permit thermal movement is important. Plate and fastener sizes are engineered for each particular project, based on project specific loading requirements. ALUM. SUPPORT POST ALUM. BASE PLATE ANCHORS RAFTER CROSS RAFTER EXTR. ALUM. RAFTER SUPPORT FASTENER STEEL FIN & C-CHANNEL BY OTHERS RAFTER CROSS RAFTER

THRU-BOLT THRU-BOLT EXTR. ALUM. RAFTER SADDLE SUPPORT ANCHORS EXTR. ALUM. RAFTER SADDLE SUPPORT ANCHORS RAFTER SUPPORT RAFTER SUPPORT

RIDGES & HIPS allow changes in the planes of the glass, often with single extruded members. Structural analysis governs the sizes. The shapes are governed by the skylight geometry and the angles of the intersecting rafters. EXTR. ALUM. HIP CAP & RETAINER EXTR. ALUM. HIP CAP & RETAINER EXPOSED TRUSSHEAD FASTENERS EXTR. ALUM. HIP TUBE INTERNAL GUSSET PLATE EXTR. ALUM. HIP TUBE HIP RIDGE

CONNECTIONS are as important as the size of spanning members to the skylight design. This section shows methods employed to join multiple members together. CLIPS, PLATES and FASTENERS are shown at standard configuration for detailing purposes, but all connections will vary according to the specific design loads & resultant calculations. INTERNAL ANGLE & CHANNEL CLIPS ANCHOR BLOCK ALUM. PIPE APEX (4 BARS) APEX (8 BARS) CROWN INTERNAL ANGLE & CHANNEL CLIPS HIP/RAFTER APEX (HIP END) RAFTER / CROSS RAFTER FORMED ALUM. ANGLE CLIPS RAFTER / SILL HIP / SILL

GUTTERS have many possible forms and are primarily detailed at the base of a skylight to quickly drain water to a discharge point. Eave gutters provide water and ice control at the transition from sloped to vertical glass planes over doors and walkways. Gutters are also used at skylight clusters with a built-in slope for quick discharge. Gutters can be formed or extruded, and contain pitched sheet metal or neoprene liners, sloped to scuppers or drain locations. Gutters are to be insulated to reduce formation of condensation on the interior and provide support for the pitched liners. Gutter details can be directly related to support details. FORMED ALUM. GUTTER FASTENERS 200RT2W/O CANTILEVERED GUTTER STRUCTURAL SEALANT EXTR. ALUM. SILL GUTTER HIGH POINT GUTTER LOW POINT INTERIOR GUTTER

GUTTERS have many possible forms and are primarily detailed at the base of a skylight to quickly drain water to a discharge point. Eave gutters provide water and ice control at the transition from sloped to vertical glass planes over doors and walkways. Gutters are also used at skylight clusters with a built-in slope for quick discharge. Gutters can be formed or extruded, and contain pitched sheet metal or neoprene liners, sloped to scuppers or drain locations. Gutters are to be insulated to reduce formation of condensation on the interior and provide support for the pitched liners. Gutter details can be directly related to support details. GRATING EXTR. ALUM. ANGLE FORMED ALUM. SUPPORT GUTTER FORMED GUTTER LINER ALUM. SUPPORT BRACKET GUTTER

THERMAL EXPANSION provisions are typically included in each horizontal crossrafter, so that thermal expansion is managed incrementally, not accumulated at one end. There are also expansion joints in the sills and heads every 10 to 20 feet, to accommodate movement yet maintain water-tightness. There are some combinations of size, geometry, and supporting structure which may require double members bridged by expansion materials. This condition will always occur when the skylight frame intersects building expansion joints, and the frame needs to be separated to accommodate movement of the building. Seismic activity in some areas requires specific engineering, using sliding connections and expansion type joints to avoid racking of the frame (not shown). ALUM. CLIP NEOPRENE EXPANDABLE ALUM. NEOPRENE EXPANSION JOINT END RAFTER w/ EXPANSION JOINT

SNOW GUARDS CONT. 1 4" ALUM. ANGLE FABRICATED TEE SUPPORT @ EA. RAFTER CONT. 1 4" ALUM. ANGLE FABRICATED TEE SUPPORT @ EA. RAFTER SNOW GUARD STAINLESS STEEL RETAINER PLATES 5 8" ST. STEEL TUBE 3 16" ALUM. TUBE STAINLESS STEEL RETAINER PLATES 3 8" SPLICE PIN 5 8" ST. STEEL TUBE SNOW GUARD SUNSCREEN SHADES EXTR. ALUM. RAFTER TUBE ALUMINUM SUNSCREEN SUNSCREEN

G1 VENTED RIDGES ALUM. VENTED RIDGE CABLES CLEVIS & CABLE CABLE BRACING FORMED ALUM. PLATE FORMED ALUM. PLATE CLEVIS & CABLE CABLE BRACING

L2 - L2 OPP. 350RT2 GS1.2* GS1.2* L2 - L2 OPP. 350RT2 GS1.2* GS1.2* 350RT2 350RT2 OPERABLE VENTS ALUM. VENT FRAME: OPERABLE SIDE ALUM. VENT FRAME: FIXED SIDE L2 - L2 OPP. 24V-DC LINEAR ACTUATORS OPERABLE VENT 24V-DC LINEAR ACTUATORS ALUM. VENT FRAME: OPERABLE SIDE ALUM. VENT FRAME: FIXED SIDE L2 - L2 OPP. OPERABLE VENT

ISOMETRIC TYPICAL SILL RETAINER (IF REQ'D) SECTION TYPICAL LAP JOINT (6" LAP & SEAL) RETAINER (IF REQ'D) AT STANDING SEAM ROOFS REGLET & COUNTER BY OTHERS REGLET DETAILS SILL BATTEN CLOSURE BY OTHERS SAW CUT SURFACE MOUNT SASH GABLE END ISOMETRIC: TRANSITION ISOMETRIC: GABLE END