CEL63x Sound Level Meter CEL630, CEL631, CEL632, CEL633 Class 1 or Class 2. Integrating. Advanced Logging. Audio Recording

Similar documents
NoiseMeters. The Practical & Easy To Use Solution for Industrial & Environmental Noise Measurements.

NoiseMeters. Integrating Sound Level Meters Effective Solutions For Industrial Noise Management

A Guide to Noise Measurement Terminology

CEL 630 Series Full Color Real Time Analyzers

A Guide to Environmental Noise Measurement Terminology

CR:247 Invictus. Portable Noise Monitor. Features. Features. Applications

Think environment Think Casella

SC101. Class 1 integrating sound level meter with measurement. Applications Includes measurement protocols for: Noise generated by motor vehicles

CEL 200 Series Simple Sound Level Meters

Real time spectrum analyser sound level meters

Environmental Noise Measurement Kits

SoundExpert LxT Sound Level Meter:

SoundExpert TM LxT. Display Navigation. Dual Purpose Start/Stop Reset/Clear Memory. Recessed On/Off Button. USB Host (Thumb Drive Storage)

SoundExpert TM LxT. n Site Assessment Run/Pause Control. Display Navigation. Dual Purpose Start/Stop Reset/Clear Memory. Recessed On/Off Button

Progress driven by research

Fractional Octave Analysis and Acoustic Applications

CR:800C Sound Level Meters

SC160. Integrating Sound Level Meter Real time frequency Analyser* in Octave Band

English. Operating manual. Integrating Sound Level Meter Spectrum Analyzer HD2010UC/A. Keep for future reference.

Precision Integrating Sound Level Meter

NEW! XL2 EXELLINE HANDHELD AUDIO AND ACOUSTIC ANALYZER LESS NOISE. MORE SOUND. Sound Level Meter. Real Time Analyzer. FFT Analyzer.

NA-28. Top of the Rion Range of Sound Level Meters. Sound level meter and 1/3 octave band real-time analyzer

NEW! XL2 EXELLINE HANDHELD AUDIO AND ACOUSTIC ANALYZER LESS NOISE. MORE SOUND. Sound Level Meter. Real Time Analyzer. FFT Analyzer.

SC420. Class 1 sound level meter and spectrum analyser * by third octave bands DATASHEET

THE ANV MEASUREMENT SYSTEMS SOUND INSULATION TESTING SYSTEM INSTRUCTION MANUAL FOR FIELD TESTING OF WALLS, FLOORS & STAIRS

2260 INVESTIGATOR MODULAR PRECISION SOUND ANALYZER WITH APPLICATION SOFTWARE BZ 7210, BZ 7203, BZ 7204, BZ 7205, BZ 7206, BZ 7207, BZ 7208

DiGi++ Noise Meter. Main functions

Standalone High Accuracy Transformer Analysis. Basic 0.02dB with class leading high frequency performance. RS232, USB and LAN as standard

PRODUCT DATA. PULSE Multichannel Sound Power Type 7748 Version 1.2

USER MANUAL SVAN 971 POCKET-SIZE SOUND LEVEL METER & ANALYSER. Copyright 2018 SVANTEK. All rights reserved.

Testing Motorola P25 Conventional Radios Using the R8000 Communications System Analyzer

SC420. Sound Level Meter Spectrum Analyser USER MANUAL. M_SC420_v0014_ _ENG

TECHNICAL REPORT 2016 IEL ENVIRONMENTAL NOISE SURVEY OF THE DAIRYGOLD CASTLEFARM FACILITY, MITCHELSTOWN, CO. CORK.

Noise and Vibration Measurement Instruments. Product Guide

Airborne Sound Insulation

For Isotropic Measurement of Magnetic and Electric Fields

Application Note: Testing P25 Conventional Radios Using the Freedom Communications System Analyzers

Thank you for purchasing the Boogie sound level meter from SINUS Messtechnik GmbH.

Trunking Information Control Console

Nor150 Sound Intensity Option Sound intensity probe Nor1290

Black. LWECS Site Permit. Stearns County. Permit Section:

Click on the numbered steps below to learn how to record and save audio using Audacity.

Basic Transceiver tests with the 8800S

Technical Documentation

vscan Data Sheet V1.0

Advanced Test Equipment Rentals ATEC (2832)

We recommend you keep the following records for reference, as well as a copy of your sales receipt: Serial number: Date of purchase:

Protocol for Ambient Level Noise Monitoring

Environmental Noise Management Sofia December Brüel & Kjær S&V Torben Munk

WMC accesses your mobile device s microphone, speaker and location while signed in. All WMC data is deleted when you sign out.

SW Series Impedance Tube Solutions

The Nor121 Analyser. - for any Environmental or Building Acoustic measurement

PIPELINE DEFECT MAPPER

SC310. Integrating sound level meter real time spectrum analyser* in one third octave and octave bands

PRODUCT DATA. Sound Intensity Calibrator Type Uses and Features

OPERATING MANUAL HANDHELD AUDIO AND ACOUSTIC ANALYZER

Nor150 Sound Intensity Option Sound intensity probe Nor1290

C1.1 Specification of the SVAN 971 as SLM in the standard configuration

PRODUCT DATA. Noise Monitoring Terminal Plus Type 3639-E Noise Monitoring Terminal Advanced Type 3639-G. Uses and Features

Offaly County Council

Environmental Sound Monitor NA-37 E n v i r o n m e n t a l S o u n d M o n i t o r (For Environmental Measurement) NA-37

JD723A/JD724B/JD726A Cable and Antenna Analyzers

Seismograph Sales Options

21. Technical Data XL2

Measurement History. Run Control with Measurement History CHAPTER

SC260. Integrating sound level meter real time spectrum analyser* in one third octave and octave bands

Measuring procedures for the environmental parameters: Acoustic comfort

AMPLITUDE MODULATION CASE STUDY AT THE LEONARDS HILL WIND FARM, VICTORIA, AUSTRALIA

PERMANENT AND SEMI-PERMANENT NOISE MONITORING - FIRST RESULTS IN THE CITY OF NIS

TurboVUi Solo. User Guide. For Version 6 Software Document # S Please check the accompanying CD for a newer version of this document

The difference between hearing and hearing

Roche Ireland Limited

Product description: sp_walk400h_cardiolinespa_07_eng1.doc 1/2

Microphone Cartridge Model: MP201

Technical Data Measurement Microphones

ODEON APPLICATION NOTE Calculation of Speech Transmission Index in rooms

Portable Multi-Channel Recorder Model DAS240-BAT

BSWA SW420R Impedance Tube System

The ArtemiS multi-channel analysis software

Lesson 3 Measurement of sound

Programming Parameter Guide

Causes for Amplitude Compression AN 12

MIT400/2 CAT IV Insulation testers

Wireless Pressure Station with Backlight

3D Intermodulation Distortion Measurement AN 8

User Manual USB Condenser Microphone

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

Personal & Area Monitors

Owner s Manual PMR 446 Handheld transceiver G5

RD547 Intelligent Geophone. Multi-function leak detector

Arbitrary/Function Generators AFG3000C Series Datasheet

Exposure Level Tester ELT-400

FAST TRACK READ ME FIRST! FAST TRACK E300 A Quick-Start Guide to Installing and Using Your COOLPIX 300. Contents. Nikon View... 25

Acoustic Calibration Service in Automobile Field at NIM, China

Roche Ireland Limited

a Loop System LA240 User manual ACCESS TO SOUND

SVAN A DESCRIPTION OF GROUND VIBRATION FUNCTION. SVANTEK Sp. z o.o. WARSAW, July 2014 SVANTEK

SLM-52N INSTRUCTION MANUAL

SmartRig+ UC. Two-channel Mic & Guitar Interface. For USB Type-C Devices

Transcription:

CEL63x Sound Level Meter CEL630, CEL631, CEL632, CEL633 Class 1 or Class 2. Integrating. Advanced Logging. Audio Recording Environmental Noise Boundary noise assessments Noise nuisance complaints Measurements to ISO1996, BS4142 Short or long term assessments Noise source identification Occupational Noise Workplace noise assessments Selection of hearing protection Noise exposure calculations Compliance with international regulations Environmental and Occupational The CEL630 complies with the latest IEC and ANSI international standards for sound level meters, as required for both environmental and occupational noise measurement. By implementing the latest digital technology, the meter has a single measurement range so no range adjustment is required, ensuring the highest levels of performance with all noise sources. Models are available for both environmental and/or occupational noise with the availability of frequency analysis and advanced functions such as data markers, timers and the logging of time history data. Key Features Easy to use Preconfigured setups Audio recording Single range Level triggered events Real-time 1/3 octave More than 1 year storage All models have a voice notes capability, allowing you to speak into the microphone before or after a measurement in order to annotate the result, so you don t need to write things down. Data can also be marked during a measurement to signify either an anomalous or significant event and can be recorded for later noise source identification. If the instrument is used for unattended measurements, audio recording can be triggered by a condition such as a given level being exceeded for a period of time.

Environmental Noise NoiseMeters Simultaneous broadband and frequency measurement Automatic repeating measurements Daily timers Data markers Real-time frequency analysis Single measurement range (no range selection needed) Triggered event capture Up to 60 hours of audio files can be stored, commonly used for noise source identification. Stored audio can be played back on the instrument using headphones or downloaded to the Insight software for playback over the computer s speakers. For unattended monitoring, event mode (CEL633) allows trigger levels (db) to be set, so additional data (e.g. Leq, Lmax) is stored together with the audio file for later analysis, as well as an additional time history profile down to 10ms intervals. Outdoor Kit Option An environmental noise monitoring kit is available to protect the instrument and microphone from the weather and allowing unattended monitoring for up 10 days. Marking significant noise events Listen to audio recordings Real-time 1/3 octave Single Range Three simultaneous storage rates The models for Environmental Noise are the CEL631 and CEL633 as these include the environmental parameters (L10, L90, etc.). We recommend the CEL633 model as it includes the advanced timers and the Time History Noise Profile, providing a detailed graph of sound level over time.

Occupational Noise NoiseMeters Simultaneous measurement of all parameters Standard setups for workplace noise legislation ISO (EU), OSHA, CGIH, DOD, Environmental User custom setups saved Measures parameters for hearing protection selection by the SNR, HML and octave band method Analyse time history of noise levels (CEL632 and CEL633) Optional high range microphone, up to 165dB The CEL630 Series is designed to make workplace noise measurements as quick and simple as possible. The displayed information can be made as simple or comprehensive as required and all measurement parameters are stored simultaneously, so nothing gets missed. When the unit is calibrated with the CEL120 calibrator, the calibration dates and times are stored and downloaded to the Insight software, validating the accuracy of measurements. Average, peak, and octave band measurements are performed at the same time, so only one measurement needs to be made for all workplace noise applications. Record voice notes to identify measurements Icon based user interface Octave measurements for selection of PPE Time history of the noise levels The models for Occupational Noise are the CEL630 and CEL632. If you intend leaving the meter monitoring unattended (on a tripod in a workshop for example) then we recommend the CEL632 model as it includes the Time History Noise Profile, providing a detailed graph of sound level over time.

Four Easy Steps Using the CEL630 series meter is as easy as switching on and pressing Run. Sometimes you may need to change the viewed parameters so this is included here. Of course there are more advanced settings in the meter s menu for setting up automatic measurements times, repeating measurements, audio recording triggers, and so on. But for a quick hand-held measurement there is little to do as the meter stores all parameters (no matter what is displayed on screen) and has a single measurement range covering 20 to 140 db. Step 1 Select the measurements you want to see. Only necessary if you want to change - as it remembers your last settings. This only changes what is displayed on screen, all other measurements are still stored. Step 2 Calibration is important to validate your measurement. The CEL630 detects the calibration tone and automatically switches into calibration mode. The Calibration result is stored in the meter. Step 3 Record Voice Notes so that you can identify the measurement after download to a computer - or even directly from the meter using headphones. Step 4 Start the measurement. The status bar turns green to show the meter is running. Press the View key to cycle through the different display screens. This helps if writing down details of the measurement is not convenient.

Model Selection There are four models available: CEL630 Occupational Noise CEL631 Environmental Noise CEL632 Advanced Occupational Noise CEL633 Advanced Environmental Noise These models have the features shown below: Class and Filters To the CEL63x order code, add A for standard version, B for Octaves and C for 1/3 Octaves. For Class 1 add 1 and for Class 2 add 2. E.g. The CEL633C1 is the advanced environmental meter, Class 1 with octave and 1/3 octave band filters. Typical environmental noise measurements: L10, L90, etc. Overall measurement results after Run/Stop, such as Lmax, Leq. Periodic measurements and detailed time history graph. Model 630 631 632 633 Cumulative Results Y Y Y Y Period & Profile Y Y Statistical Values (Ln%) Y Y Audio Voice Notes Y Y Y Y Audio Recording Y Y Marker Events Y Y Level Events Y Record notes about the measurement for later identification. Press a button to mark a noise event - e.g. car, bus, motorcycle. Automatic event detection based on sound level. Record the audio during measurement to identify sources later. Accessories CEL6840 Standard Case (included with meter) 196030C Executive Case (included with kit) CEL251 Microphone Class 1 CEL252 Microphone Class 2 CEL120/1 Calibrator Class 1 CEL120/2 Calibrator Class 2 PC18 Power Supply MIC1 High Range Microphone (to 165dB) MPA1 High Range adapter (use with MIC1) Noise Measurement Kits The Noise Measurement Kits include the following items: Sound Level Meter Calibrator Carrying Case Add K to the order code for a kit. For example, CEL633C1-K.

Insight Data Management Software Analysis of noise level time history Replay voice notes and event audio Intuitive user interface Remove anomalous data from results Analysis of time history Generate comprehensive reports Store data by, person, place, location Manage multiple instruments and calibration Manage data or instruments Tree structure to manage the data Time history may be viewed, analysed and annotated Sort data by person, process, place, etc. Multiple parameters displayed and sorted simultaneously Data can be dragged and dropped to the tree structure Data is graphed and can be copied to other applications The Insight software is a powerful yet simple tool to download, analyse and generate reports. The software automatically recognises that the meter is connected and downloads and saves the data. Noise exceedance levels can be colour coded by a simple traffic light system, it is easy to see which measurements have exceeded specific levels. For the CEL632 and CEL633, the stored data can be graphed and zoomed in to look at specific times. These graphs can be further analysed by recalculating levels inside and outside defined zones, to investigate what if scenarios. Data can be managed by person, place or process by dragging and dropping to the relevant tree location. Templates are provided to view data for local legislation or can be customised, Reports can be stored in multiple formats (e.g.pdf,.jpg, or.csv) allowing them to be shared and viewed easily, as well as exported to other applications. The report wizard allows creation of a report for people, processes etc. It allows measurement parameters to be selected as required and report settings are retained for the next time it is used. Written notes can be added to data (on top of any audio notes recorded when taking a measurement), to appear on the reports.

Technical Specifications Standards IEC61672: 2002 Class 1 and 2 ANSI S1.4: Type 1 and 2 (1983) Filters: IEC61260: Class 0, ANSI S1.43: (1996) Note: IEC61672 replaces 2 obsolete standards IEC60651 and IEC60804 General Range: 20-140dB RMS (143.3dB peak) Noise floor: 19dB(A) Class 1 25dB(A) Class 2 Time wgts: Fast, Slow and Impulse simultaneously Frequency wgts: A, C and Z (un-weighted) simultaneously Frequency bands: 11 Octave bands 16Hz-16kHz (B&C models) 33 Octave bands 12.5Hz-20kHz (C models) Amplitude wgt (Q): 3, 4 and 5 simultaneously Back erase: Last 10s in cumulative mode Timers: Duration 1s-24h, On/Off timers: 6 sets with selectable times and a repeat function Physical Tripod mount: Batteries: External power: Weight: Size: Environmental 1/4 Whitworth socket 3x AA Alkaline, 10-15 hours dependent on back light 9-14V DC at 150mA 332g including batteries 230x72x31mm inc preamp and microphone Memory Memory: 2GB (>1 year logging when set to 1 second interval). All parameters stored and accessible via Casella insight. Total measurement runs: 999. Events: 999 events/run. 10 hours of audio recording in high quality mode, 60 hours in low quality mode. For long term unattended monitoring the CEL-630 takes a new run daily for up to a total of 400 days. Audio Recording Low Quality: 8,000 samples/s @ 8bit (64kb/s) High Quality: 24,000 samples/s @ 8 bit (192kb/s) Languages User interface can be changed via the menu: English, French, German, Spanish, Italian, Portuguese, Chinese. Measured Parameters Broadband: LXY, LXYmax, LXYmin, LXeq, LXpeak, Lavg, LC-LA, LXIeq, LTM3, LTM5, LAE. Workplace dose values are calculated within Insight software. Octaves & 1/3 octaves: LXY, LXeq, LXYmax, 5x Ln% (on CEL631 and CEL633). Where X is the frequency weighting A, C or Z and Y represents time weighting Fast (F), Slow (S) or Impulse (I). All weightings simultaneously measured where appropriate. CEL631 and CEL633 models additionally store 5x Ln values in broadband and octave modes. Relative humidity: Temp: Atmos. pressure: 5 to 90% (non condensing) Class 1: -10 to +50 C Class 2: 0 to 40 C 65 to 108kPa CEL632 and CEL633 models additionally stores time history data, all parameters are logged for period times plus 6 selectable profile parameters (plus 5x Ln values on CEL633). NoiseMeters in the UK NoiseMeters in the USA NoiseMeters Ltd 97 Brighton Road Surbiton KT6 5NF United Kingdom NoiseMeters Ltd West End Muston YO14 0ES United Kingdom NoiseMeters Inc 3233 Coolidge Hwy Berkley MI 48072 USA Texas Warehouse 1321 Upland Dr, #2174 Houston TX 77043 USA Tel: 0845 680 0312 info@noisemeters.co.uk Tel: 888 206 4377 info@noisemeters.com