Radiographic Techniques, Contrast, and Noise in X-Ray Imaging

Similar documents
X-Ray-Based Medical Imaging and Resolution

Kerma-Area Product in Diagnostic Radiology

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

The importance of radiation quality for optimisation in radiology

X-RAY IMAGING EE 472 F2017. Prof. Yasser Mostafa Kadah

X-ray Imaging. PHYS Lecture. Carlos Vinhais. Departamento de Física Instituto Superior de Engenharia do Porto

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Mammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over

Dose Reduction and Image Preservation After the Introduction of a 0.1 mm Cu Filter into the LODOX Statscan unit above 110 kvp

LECTURE 1 The Radiographic Image

While digital techniques have the potential to reduce patient doses, they also have the potential to significantly increase them.

Exposure Indices and Target Values in Radiography: What Are They and How Can You Use Them?

I. PERFORMANCE OF X-RAY PRODUCTION COMPONENTS FLUOROSCOPIC ACCEPTANCE TESTING: TEST PROCEDURES & PERFORMANCE CRITERIA

Published text: Institute of Cancer Research Repository Please direct all s to:

Studies on reduction of exposure dose using digital scattered X-ray removal processing

Studies on reduction of exposure dose using digital scattered X-ray removal processing

Effect of Backscattered Radiation on X-Ray Image Contrast

I. Introduction.

Digital Imaging started in the 1972 with Digital subtraction angiography Clinical digital imaging was employed from the 1980 ~ 37 years ago Amount of

Beam-Restricting Devices

The effect of compensating filter on image quality in lateral projection of thoraco lumbar radiography

Effect of patient support pads on image quality and dose in fluoroscopy a)

STEREOTACTIC BREAST BIOPSY EQUIPMENT SURVEYS

Digital radiography (DR) post processing techniques for pediatric radiology

Visibility of Detail

Comparison of computed radiography and filmõscreen combination using a contrast-detail phantom

Features and Weaknesses of Phantoms for CR/DR System Testing

PATIENT EFFECTIVE DOSES IN DIAGNOSTIC RADIOLOGY, NA

Seminar 8. Radiology S8 1

Test Equipment for Radiology and CT Quality Control Contents

- KiloVoltage. Technique 101: Getting Back to Basics

Ask EuroSafe Imaging Tips & Tricks. Paediatric Imaging Working Group. Dose Management in Digital Radiography

3/31/2011. Objectives. Emory University. Historical Development. Historical Development. Historical Development

Predicted image quality of a CMOS APS X-ray detector across a range of mammographic beam qualities

Joint ICTP/IAEA Advanced School on Dosimetry in Diagnostic Radiology and its Clinical Implementation May 2009

RAD 150 RADIOLOGIC EXPOSURE TECHNIQUE II

SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS

X-rays. X-rays are produced when electrons are accelerated and collide with a target. X-rays are sometimes characterized by the generating voltage

Image Quality Artifacts in Digital Imaging

Nuclear Associates

Management of pediatric radiation dose using Philips fluoroscopy systems DoseWise: perfect image, perfect sense

INTRODUCTION TO FLEXIBLE BRONCHOSCOPY. Fluoroscopy Synopsis HENRI G COLT MD SECOND EDITION THE BRONCHOSCOPY EDUCATION PROJECT SERIES

Mammography: Physics of Imaging

Y11-DR Digital Radiography (DR) Image Quality

RADIOGRAPHIC EXPOSURE

Veterinary Science Preparatory Training for the Veterinary Assistant. Floron C. Faries, Jr., DVM, MS

Investigation of the line-pair pattern method for evaluating mammographic focal spot performance

SYLLABUS. 1. Identification of Subject:

Learning Objectives: What s my motivation? (unknown screen actor) Workshop Overview

BASICS OF FLUOROSCOPY

10/15/2012 SECTION III - CHAPTER 6 DIGITAL FLUOROSCOPY RADT 3463 COMPUTERIZED IMAGING

Acquisition, Processing and Display

Acceptance Testing of a Digital Breast Tomosynthesis Unit

RaySafe X2. Effortless measurements of X-ray

7/24/2014. Image Quality for the Radiation Oncology Physicist: Review of the Fundamentals and Implementation. Disclosures. Outline

STUDENT REVIEW QUESTION SET K CR/DR CONTENT AREA

X-RAYS - NO UNAUTHORISED ENTRY

Overview. Professor Roentgen was a Physicist!!! The Physics of Radiation Oncology X-ray Imaging

Effect of pressure, temperature and humidity in air on photon fluence and air kerma values at low photon energies

Imaging Technique Optimization of Tungsten Anode FFDM System

Quality assurance: a comparison study of radiographic exposure for neonatal chest radiographs at 4 academic hospitals

radiography detector

PD233: Design of Biomedical Devices and Systems

Radiology Physics Lectures: Digital Radiography. Digital Radiography. D. J. Hall, Ph.D. x20893

COMPUTED RADIOGRAPHY CHAPTER 4 EFFECTIVE USE OF CR

MC SIMULATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kv X-RAY TUBE

Evaluation of X-Ray Beam Quality Based on Measurements and Estimations Using SpekCalc and Ipem78 Models

Do you have any other questions? Please call us at (Toll Free) or , or

1-1. GENERAL 1-2. DISCOVERY OF X-RAYS

Detector technology in simultaneous spectral imaging

HISTORY. CT Physics with an Emphasis on Application in Thoracic and Cardiac Imaging SUNDAY. Shawn D. Teague, MD

Advanced digital image processing for clinical excellence in fluoroscopy

Teaching Digital Radiography and Fluoroscopic Radiation Protection

Introduction. Sam R. Kottamasu Lawrence R. Kuhns

Practical Medical Physics Session: TG-151 Dose Monitoring. August 5, 2013 Katie Hulme, M.S.

Enhanced Functionality of High-Speed Image Processing Engine SUREengine PRO. Sharpness (spatial resolution) Graininess (noise intensity)

4. Contrast is the. There must The function of contrast is to:. The types of contrast are.

Outline. Digital Radiography. Understanding Digital Modalities: Image Quality and Dose. Image Quality. Dose Control

SECTION I - CHAPTER 1 DIGITAL RADIOGRAPHY: AN OVERVIEW OF THE TEXT. Exam Content Specifications 8/22/2012 RADT 3463 COMPUTERIZED IMAGING

DISC QC/QA Program for Digital Imaging Systems using the DR Radchex Plus Meter

Effects of Plastic Wedges on Whole Foot Radiograph in Anteroposterior and Oblique Positions

Essentials of Digital Imaging

X-rays in medical diagnostics

Half value layer and AEC receptor dose compliance survey in Estonia

Breast Tomosynthesis. Bob Liu, Ph.D. Department of Radiology Massachusetts General Hospital And Harvard Medical School

Digital Images & Image Quality

Radiology. Radiograph: Is the image of an object made with use of X- ray instead of light.

Visualization of sources of scattered radiation from x-ray equipment used for interventional radiology

Multi-Access Biplane Lab

Fluoroscopy - Chapter 9

X-ray Tube and Generator Basic principles and construction

CR Basics and FAQ. Overview. Historical Perspective

Optimization of Digital Mammography Resolution Using Magnification Technique in Computed Radiography 1

Nuclear Associates

Assessment of Beam Alignment, Collimation and Half Value Layer of Some Selected X-Ray Machines in Plateau State, Nigeria

Overview of Safety Code 35

ELECTRONIC CONTROL CONCEPTS 160 Partition Street Saugerties, NY or local phone

SPECIFICATION. Kilovoltage X-ray calibration system for protection and diagnostic level dosimetry. Prepared by

Estimation of signal transfer property for wireless digital detector in different measurement schemes

Amorphous Selenium Direct Radiography for Industrial Imaging

Transcription:

Residents Section Physics Minimodule Huda and Abrahams Techniques, Contrast, and Noise in Radiography Residents Section Physics Minimodule Residents inradiology Walter Huda 1 R. Brad Abrahams 2 Huda W, Abrahams RB Keywords: contrast, contrast-to-noise ratio, noise, tube output, tube voltage DOI:10.2214/AJR.14.13116 Received May 8, 2014; accepted after revision May 16, 2014. 1 Department of Radiology and Radiological Science, Medical University of South Carolina, 96 Jonathan Lucas St, MSC 323, Charleston, SC 29425. Address correspondence to W. Huda (Walterhuda@hotmail.com). 2 Department of Radiology and Imaging, Georgia Regents University, Augusta, GA. WEB This is a web exclusive article. AJR 2015; 204:W126 W131 0361 803X/15/2042 W126 American Roentgen Ray Society Radiographic Techniques, Contrast, and Noise in X-Ray Imaging R adiologists are responsible for the manner in which radiologic examinations, including radiographs, mammograms, and CT images, are obtained. Radiographic protocol parameters should be selected to ensure adequate diagnostic performance, and radiologists therefore need to understand the image creation process, in addition to interpreting radiologic examinations [1 4]. The choice of protocol parameter also affects the amount of radiation received by the patient, and radiologists need to ensure that patients are not being subjected to unnecessary radiation exposure. The most important aspect of the choice of protocol parameters is to ensure that the image quality will be sufficient for a given diagnostic imaging task [5]. It is therefore essential for radiologists to understand how choices for each protocol parameter will affect the resultant image being generated. Key x-ray choices include the voltage across the x-ray tube (kilovoltage), the size of the x-ray tube current (milliamperes), and the imaging exposure time (seconds) [6, 7]. Although artifacts in radiographic imaging are of obvious importance for image quality, these are beyond the scope of this article [8]. X-Ray Tube Output Quantity Important determinants of x-ray beam quantity are the choice of tube current (milliamperes) and the corresponding x-ray beam exposure times (seconds) [9 11]. The product of the tube current and exposure time, known as the milliampere-second value, is the primary indicator of the x-ray beam intensity. The milliampere-second value indicates the relative radiation output for a given x-ray tube when operated at a specified tube voltage, but does not account for differences between x- ray systems using a variety of tubes and filtration. For this reason, it is generally not very helpful or informative to describe any radiographic examination as being performed at a given milliampere-second value. The intensity of an x-ray beam is quantified by an air kerma, which relates to the kinetic energy released per unit mass when x- rays interact with air [12]. Air kerma is the energy transferred to electrons when normalized by the mass of air (energy/mass) and is measured using grays or milligrays. Air kerma can be thought of as the number of x-rays per unit area, with the photon energies of minimal concern. The air kerma in any x-ray beam is directly proportional to both the tube current and the corresponding exposure time. Because air kerma is well defined and universally understood, it is the metric of choice for specifying x-ray beam intensity. The higher the air kerma, the higher the x-ray beam s intensity, and the more photons will be incident on the patient. When air kerma is multiplied by the corresponding beam area, one obtains the kermaarea product in grays times square centimeters (Gy = cm 2 ), which is often referred to as the dose-area product [12]. The kerma-area product is the total amount of radiation incident on the patient and will affect the energy deposited into the patient. Air kerma is used to estimate the entrance skin dose and thereby the likelihood of a deterministic (skin) radiation risk. Kerma-area product quantifies the total amount of radiation incident on the patient and is most closely related to the total stochastic patient risk. For most patients, the stochastic risk can be taken as the carcinogenic risk. Table 1 shows representative values of kerma-area product for complete examinations in radiologic imaging [13]. Quality The quality of an x-ray beam refers to the penetrating power of the beam and is normally expressed as a half-value layer (HVL) W126 AJR:204, February 2015

Techniques, Contrast, and Noise in Radiography of aluminum (in millimeters). When a halfvalue layer thickness of aluminum is placed into the x-ray beam, it reduces the intensity (air kerma) by 50%. A typical x-ray beam used in abdominal radiography would likely have an HVL of 3 mm of aluminum. Figure 1 shows that 0.3 mm of copper (atomic number, 29), 3 mm of aluminum (atomic number, 13), or 30 mm of soft tissue (atomic number, 7.5) all attenuate half the x-ray beam, illustrating the paramount importance of the atomic number of the attenuator [14]. When the average x-ray beam energy increases, meaning the x-ray beam has increased penetrating power, the HVL also increases. In radiography, the two important determinants of x-ray beam quality are tube voltage and beam filtration. Increasing the tube voltage or the total amount of filtration or both will increase the average photon energy and thereby the x-ray beam penetrating power. It is important to note that adding filters always reduces the x-ray tube output (quantity) but increases x-ray beam penetrating power (quality). The most common filter material used in radiography is aluminum, with a typical filtration in routine radiography being about 3 mm of aluminum. Copper is also used in modalities for which dose issues are important, specifically in pediatrics and interventional radiology. In mammography, the most common filter materials are molybdenum, rhodium, and silver. CT makes use of relatively heavy filtration, with aluminum, copper, and titanium being the most frequently used materials. A typical radiographic x-ray beam in abdominal radiography will have an x-ray tube voltage of 80 kv and a total filtration of about 3 mm of aluminum. The x-ray beam quality is likely to be also 3 mm of aluminum, which is easily confused with the filtration because they are often quantitatively very similar. Fig. 2 Increasing milliampere-second (mas) value proportionally increases number of x-rays produced with no change in average photon energy (left). When tube voltage (kv) increases, more photons are produced, and average photon energy also increases (right). Increasing milliampere-second value only increases quantity, whereas increasing kilovoltage increases quantity and quality. (Illustrations by Abrahams RB) TABLE 1: Representative Values of Kerma-Area Product in Radiologic Imaging Type of Radiologic Examination Kerma-Area Product (Gy - cm 2 ) Radiography 1 Fluoroscopy (gastrointestinal and urologic) 20 Interventional radiology 100 300 Fig. 1 Material thickness (atomic number, Z) needed to attenuate x-ray beam (80 kv + 3 mm aluminum filtration) by 50%. Notice dramatic reduction in material thickness as atomic number increases. (Illustrations by Abrahams RB) Beam qualities in mammography are very low and of the order of 0.4 mm of aluminum. A typical CT x-ray tube voltage is 120 kv, and the filtration can consist of 2 mm of aluminum with an additional 0.1 of copper or 1 mm of titanium. The resultant HVLs will be of the order of 6 mm of aluminum or even higher, markedly greater than those encountered in radiography. Technique Selection When the amount of radiation needed to generate an image is to be increased, this will generally be achieved by increasing the milliampere-second value, as shown in Figure 2. It is important to note that changing the milliampere-second value does not modify the x-ray beam spectrum. The average photon energy remains constant, resulting in the same (percentage) transmission through the patient. When possible, increasing the milliampere-second value should be done by increasing the tube current (milliamperes). In practice, this may not be possible because of tube heating limitations or because the maximum tube current available is already being used. In such cases, increasing the milliampere-second value will generally require longer exposures, thereby increasing the likelihood of motion blur. Increasing the x-ray tube voltage will generate (many) more x-rays, as shown in Figure 2, but will also increase the beam energy (quality/hvl). In radiography, the x-ray tube output (air kerma) is generally taken to be proportional to kilovoltage squared, whereas in CT the x-ray tube output is taken to be proportional to kilovoltage to the 2.6th power [15]. However, the choice of x-ray tube voltage is generally determined by considering patient penetration, image contrast, and dynamic range requirements. Only very rarely, if ever, is the kilovoltage adjusted simply to change the amount of radiation in any x- ray examination. When kilovoltage is modified, it is always necessary to evaluate other factors, including patient penetration, scattered radiation intensities, x-ray transmission through a grid, and changes in photon absorption efficiencies in the x-ray detectors. Protocol design requires the initial selection of an appropriate x-ray tube voltage and a subsequent adjustment of the x-ray tube milliampere-second to ensure that the radiation intensity at the image receptor is the one that is desired for image quality. Figure 3 (left panel) shows a spine that is invisible (too white on the image), requiring the tube voltage to be increased to improve beam penetration (Fig. 3, middle panel). The increase in kilovoltage achieves the correct amount of penetration, but now the image is too dark (Fig. 3, middle panel), so the milliampere-second now needs to be reduced to ensure the appropriate amount of radiation AJR:204, February 2015 W127

Huda and Abrahams Fig. 3 36-year-old man with chest pain diagnosed as normal. Chest radiograph (left) is underpenetrated, requiring increase in x-ray tube voltage. After voltage (kv) has been increased (middle), radiograph is too dark. After x-ray tube output (milliampere-second [mas] value) has been reduced (right), radiograph has correct image density. (Illustrations by Abrahams RB) (air kerma) at the image receptor to achieve a satisfactory image density (Fig. 3, right panel). Because tube voltage affects output and penetration, as depicted in Figure 2, the x-ray tube current in any x-ray examination the x- ray intensity (milliampere-second) must always be adjusted when kilovoltage has been modified to ensure the appropriate amount of radiation at the image receptor. Image Quality Contrast Consider a lesion that appears in any radiologic image, where the lesion intensity is given by I lesion. If the intensity of the surrounding normal tissues is I tissue, then the lesion contrast is I lesion I tissue. Whether the contrast is positive or negative is determined by the lesion s characteristics and is not important from an image quality perspective. For example, adding iodine or carbon dioxide to a blood vessel will make the vasculature visible but of differing polarity because iodine absorbs more x-rays, whereas carbon dioxide will absorb fewer x-rays than adjacent tissues. Contrast is independent of the amount of radiation used to generate an image, as shown in Figure 4. If a lesion transmits 5% more photons than the surrounding normal tissues, this is always true regardless of whether the x-ray tube setting (and corresponding air kerma output) was 1, 10, or 100 mas. Images shown in Figure 4 illustrate the only effect of reducing the milliampere-second, is to increase the amount of image mottle. The most important factor affecting contrast is the average photon energy used to generate the image, which is determined by the choice of x-ray tube voltage and the amount of x-ray beam filtration. As the photon energy decreases, the differential attenuation between the lesion and surrounding tissues increases. Accordingly, low energy is usually associated with higher contrast and vice versa, as shown in Figure 5. Although this is generally true, it is important to note that the improvement in lesion contrast at low energies also depends on the lesion s atomic number. As the lesion s atomic number diverges from that of soft tissue (atomic number, 7.5), the contrast is affected much more. Reducing photon energy improves the contrast (i.e., visibility) of calcifications and tissues containing iodine much more than it improves the contrast of soft-tissue lesions. Two additional factors need to be considered regarding contrast relating to scatter and digital image display. Increased scatter will generally reduce contrast, which can be appreciated by looking at an abdominal radiograph obtained without the use of a scatter removal grid. Image manipulation in digital radiography can be used to modify both the brightness and contrast of any given feature. When the window width is increased, display contrast is reduced, and vice versa. Accordingly, it is possible to increase display contrast by use of narrow window widths. However, when narrow window widths are used, the range of pixel values (tissues) that are visible is also reduced. Therefore, there is a trade-off between display contrast and type of anatomy that is visible in the displayed image. A good example is the use of lung and mediastinum display settings while reading a chest CT. Fig. 4 Increasing x-ray tube output (i.e., milliampere-second [mas] value) has no effect on image contrast in digital images (left), but will require appropriate adjustment of digital display settings. When fewer photons are used to make image (right), contrast remains exactly the same, but image mottle increases. (Illustrations by Abrahams RB) Noise Consider a digital x-ray detector that is exposed to a uniform x-ray beam, with the aver- W128 AJR:204, February 2015

Techniques, Contrast, and Noise in Radiography Fig. 5 Reducing tube voltage (kv) increases image contrast (right) compared with higher tube voltage (left). In this example, automatic exposure control was used, so milliampere-second value will increase when selected kilovoltage is reduced. By keeping air kerma at image receptor same in both images, image mottle is unchanged. (Illustrations by Abrahams RB) age number of photons detected in a pixel being 100. The statistical nature of x-ray emission (and detection) means that not every pixel will detect exactly 100 photons. Some pixels have more x-rays and appear darker, whereas other pixels have fewer than 100 photons and will appear lighter. The distribution of these darker and lighter pixels is random, and the image will have a mottled appearance (salt-and-pepper distribution). Imaging scientists called this grainy appearance noise, which is synonymous with mottle. Figure 6 shows examples of chest x-ray images obtained at low and high x-ray tube output values, illustrating how image noise (mottle) decreases as the x-ray tube output (milliampere-second) increases. Because noise is random, the amount of noise does not increase in a linear manner when the amount of radiation used to generate an image increases. If the average number of photons per pixel is 100, the SD of this average value is 10, which is normally expressed as a relative SD (fluctuation) of 10%. When the number of photons increases by a factor of 4, the relative SD will be halved (i.e., 4 0.5 ) to only 5%. It is thus useful to always remember that quadrupling of the number of photons used to generate any radiographic image will halve the amount of image noise, and vice versa. Noise in virtually all x-ray imaging modalities is dominated by quantum mottle, where the latter relates to the total number of x-rays used to generate an image. Quantum mottle is dominant in all radiography, mammography, fluoroscopy, and CT examinations. This is important because the only technical way to reduce noise using any x-ray imaging modality is to use more x-rays. X-ray detection efficiencies in most x-ray imaging systems are relatively high, so improvements are not likely. In CT for example, current detectors generally absorb well over 90% of all incident photons. A corollary of the fact that virtually all of medical imaging is quantum mottle limited is that replacing components in the imaging chain, such as charge coupled device (CCD) for television camera in fluoroscopy, cannot result in dose reductions if image quality is to be maintained. Contrast-to-Noise Ratio When the contrast alone increases or noise alone is reduced, a lesion will clearly become more visible. However, the visibility of a lesion is not determined by just the noise or the lesion contrast alone. The visibility of any lesion in a radiologic image needs to take into account both the amount of lesion contrast and the corresponding amount of noise. The amount of lesion contrast relative to the amount of noise (mottle) is the key determinant of the visibility of a given lesion. The ratio of lesion contrast to image mottle is known as the contrast-to-noise ratio (CNR). This ratio is an indicator of the relative image quality of this lesion (i.e., visibility), as depicted by the images in Figure 7. Improving the visibility of any lesion will always require the lesion s CNR to be increased. This can be achieved by increasing lesion contrast or reducing the amount of noise or by a combination of these two methods. In digital subtraction angiography (DSA) imaging, one way to improve the contrast of an aneurysm (and thereby CNR) is to replace venous administration of iodinated contrast material with arterial administration of iodine. Similar results could be obtained by using more x-ray photons when creating an image, which would reduce the amount of image noise (mottle). From a lesion visibility perspective, it is only the CNR that has to be increased, and increasing contrast is equivalent to reducing noise. The optimal strategy, however, will generally depend on external factors, such as whether an x-ray system can offer more x-rays or whether the patient can tolerate such an increase in dose. Fig. 6 36-year-old man with chest pain diagnosed as normal. Image mottle is negligible in high milliamperesecond (mas) value image (left), but is very high in low milliampere-second value image (right). Because digital data in high milliampere-second value image will be much higher than low milliampere-second value image, adjustment of digital display settings (window and level) are always necessary. (Illustrations by Abrahams RB) Techniques and Image Quality Output For a single radiographic image, it is the choices of tube current (milliamperes) and exposure time (seconds) that determines the AJR:204, February 2015 W129

Huda and Abrahams total x-ray beam intensity (i.e., milliamperesecond). The maximum tube current for most radiographic units, when operated using a large focal spot, will be about 1000 ma, and the power loading will likely be about 100 kw. Small focal spot sizes may be used (e.g., to reduce blur in radiographs of the cervical spine and extremities). In these cases, the tube current and focal spot loadings are typically reduced fourfold because the focal spot area is now only a quarter of the size. In practice, an imaging system will select the largest possible tube current that can be tolerated by tube heating requirements because this will minimize the radiographic exposure time. For a given radiographic examination, the selected milliampere-second value will directly affect the amount of radiation transmitted through the patient and used to produce the resultant radiograph. For a chest x-ray, the required air kerma at the image receptor is currently about 3 μgy. If the amount of radiation at the image receptor were to be quadrupled (milliampere-second value), then the image noise (mottle) would be halved (Fig. 5). Conversely, using a quarter of the radiation (milliampere-second value) would double the amount of image noise (mottle). Patient dose is directly proportional to the milliampere-second value, and the radiologist needs to select this parameter with great care. When the choice of milliampere-second value is too low, diagnostic performance Fig. 7 Lower right image shows poor visibility of atomic pattern because of very low contrast and very high noise. Reducing noise (lower left) and increasing contrast (upper right) both improve atomic pattern visibility. Best image (upper left) is one where contrast has been increased and noise has been reduced. (Illustrations by Abrahams RB) could be compromised. Conversely, selecting a milliampere-second value that is too high results in patients being unnecessarily exposed to radiation and thus subjected to unnecessary radiation risks. TABLE 2: Penetration of Monoenergetic Photons Through Varying Patient Thicknesses (Water or Soft Tissue) Simulating Adult Patients Patient Tissue Thickness (cm) Patient Penetration (%), by Photon Energy Level 40 kev 50 kev 60 kev 18 0.82 1.7 2.5 23 0.22 0.54 0.88 28 0.06 0.17 0.31 33 0.01 0.06 0.11 TABLE 3: Penetration of Monoenergetic Photons Through Varying Patient Thicknesses (Water or Soft Tissue) Simulating Pediatric Patients Undergoing Imaging Patient Tissue Thickness (cm) Patient Penetration (%), by Photon Energy Level 30 kev 40 kev 8 5.2 12 10 2.5 6.9 12 1.2 4.1 15 0.39 1.8 18 0.13 0.82 Voltage When selecting the x-ray tube voltage in any radiographic examination, the first consideration is the issue of patient penetration (Fig. 3). Low x-ray tube voltages mean low photon energies that may not penetrate the patient and would be of little value in radiographic imaging. X-ray penetration and the appropriate x-ray tube voltage are also related to patient size. Data in Table 2 show how x-ray beam penetration varies with average photon energy for adult patients, and Table 3 shows similar data for pediatric patients. In general, reduced voltages can be used for small patients, whereas for larger patients, it is essential to increase patient penetration by increasing the tube voltage. Once adequate penetration has been achieved, it may nonetheless be advantageous to use even higher photon energies (i.e., increased kilovoltage). Although image contrast is generally reduced at high photon energies (as already discussed), so is the dynamic range of the resultant image data. The dynamic range is obtained by focusing on the air kerma values in the patient anatomic region and comparing the highest receptor air kerma to the lowest receptor air kerma. For examinations such as chest radiographs, where the intrinsic contrast is generally satisfactory, it is essential to reduce the image dynamic range. On radiographs, low voltages that produce very large dynamic ranges will result in the higher exposures in the lung appearing all black and the lower exposures in the mediastinum appearing all white. High voltages that reduce the im- W130 AJR:204, February 2015

Techniques, Contrast, and Noise in Radiography age dynamic range are therefore used when performing diagnostic chest radiographs on dedicated imaging systems located within the radiology department. Use of high x-ray tube voltages reduces patient doses when automatic exposure control is used. Higher voltages result in higher energies that increase patient penetration. When the radiation intensity at the image receptor is fixed, the radiation incident on the patient can be reduced. Most radiography and fluoroscopy systems use automatic exposure control; therefore, the use of high tube voltages is associated with lower patient doses [16, 17]. In CT, however, automatic exposure control systems only adjust the tube current (milliamperes) and do not currently modify the tube voltage. In CT, therefore, understanding of patient doses requires explicit information regarding the selected tube voltages (kilovoltage) and the corresponding tube currents (milliamperes). Increasing CT kilovoltage can result in higher patient doses when tube currents (milliamperes) are kept constant. Increasing CT kilovoltage, however, can lower patient doses when the tube currents (milliamperes) are (markedly) reduced to take advantage of the increased patient penetration. Contrast-To-Noise Ratio The two parameters that are easy to adjust in any radiographic imaging protocol are the x-ray tube voltage (kilovoltage) and the total radiation intensity (milliampere-second value) used to obtain the image. This is true in all x-ray-based imaging modalities, including radiography, mammography, fluoroscopy, and CT [18, 19]. It is the responsibility of the radiologist to adjust these key parameters, which affect image quality and the corresponding patient dose. The overall objective is to ensure that images are of diagnostic quality without exposing patients to unnecessary radiation. When a patient is exposed to an x-ray beam, there is a well-defined and quantifiable patient dose. The resultant image, however, does not have a corresponding welldefined image quality. The reason for this is that image quality is always task dependent. When a radiograph is obtained to detect a subtle soft-tissue lesion, minimizing the amount of mottle will be very important because the intrinsic lesion contrast is relatively low. On the other hand, a radiograph to identify the location of a swallowed coin would need much less radiation because the intrinsic contrast of the coin is so high. The amount of acceptable mottle in a diagnostic chest x-ray examination is likely to be low and requires an image receptor air kerma of about 5 µgy. A follow-up scoliosis examination, where the clinical question relates to any changes in spine curvature, could likely be obtained using 10 times less radiation [20]. Although the image mottle at such low doses would obviously be relatively high, the radiograph would nonetheless be adequate for answering the posed clinical question. The fact that image quality is always task dependent is perhaps the most important lesson that imaging scientists have to teach the radiologic imaging community. Conclusion Understanding the image creation process as it relates to the interplay of contrast, noise, patient dose, and diagnostic performance is vital in the practice of modern radiology. Tube voltage selection affects the amount of contrast in the resultant image, and the selected milliampere-second value affects the corresponding image mottle. The resultant CNR may be taken as a relative indicator of the visibility of a given lesion. When a lesion needs to be made more visible, this may be achieved by increasing the contrast, reducing the noise, or by a judicious combination of both aspects. The radiographic techniques that may be used to adjust a lesion s CNR are thus the kilovoltage and milliampere-second value. As in all radiographic imaging, the optimal values depend on the physical characteristics of the patient and the specific diagnostic imaging task. References 1. Bushberg JT, Seibert JA, Leidholdt EM, Boone JM. The essential physics of medical imaging, 3rd ed. Philadelphia, PA: Lippincott, Williams & Wilkins, 2012 2. Huda W. Review of radiologic physics, 3rd ed. Philadelphia, PA: Lippincott Williams & Wilkins, 2010 3. Nickoloff EL. Radiology review, radiological physics. Philadelphia, PA: Elsevier Saunders, 2005 4. Wolbarst AB. Physics of radiology, 2nd ed. Madison, WI: Medical Physics Publishing, 2005 5. Siegel MJ, Schmidt B, Bradley D, Suess C, Hildebolt C. Radiation dose and image quality in pediatric CT: effect of technical factors and phantom size and shape. Radiology 2004; 233:515 522 6. Gkanatsios NA, Huda W, Peters KR. Effect of radiographic techniques (kvp and mas) on image quality and patient doses in digital subtraction angiography. Med Phys 2002; 29:1643 1650 7. Huda W, Ravenel JG, Scalzetti EM. How do radiographic techniques affect image quality and patient doses in CT? Semin Ultrasound CT MR 2002; 23:411 422 8. Shetty CM, Barthur A, Kambadakone A, Narayanan N, Kv R. Computed radiography image artifacts revisited. AJR 2011; 196:[web]W37 W47 9. McCollough CH. The AAPM/RSNA physics tutorial for residents: X-ray production. Radio- Graphics 1997; 17:967 984 10. Seibert JA. The AAPM/RSNA physics tutorial for residents: X-ray generators. RadioGraphics 1997; 17:1533 1557 11. Zink FE. X-ray tubes. RadioGraphics 1997; 17:1259 1268 12. Huda W. Medical radiation dosimetry. In: Frush DP, Huda W, eds. RSNA categorical course in diagnostic radiology physics: from invisible to visible the science and practice of x-ray imaging and radiation dose optimization. Oak Brook, IL: Radiological Society of North America, 2006:29 39 13. Huda W. Kerma-area product in diagnostic radiology. AJR 2014; 203:W565-W569 14. McKetty MH. The AAPM/RSNA physics tutorial for residents: x-ray attenuation. RadioGraphics 1998; 18:151 163; quiz, 149 15. Elojeimy S, Tipnis S, Huda W. Relationship between radiographic techniques (kilovolt and milliampere-second) and CTDI VOL. Radiat Prot Dosimetry 2010; 141:43 49 16. Pooley RA, McKinney JM, Miller DA. The AAPM/RSNA physics tutorial for residents: digital fluoroscopy. RadioGraphics 2001; 21:521 534 17. Schueler BA. The AAPM/RSNA physics tutorial for residents: general overview of fluoroscopic imaging. RadioGraphics 2000; 20:1115 1126 18. Nickoloff EL. AAPM/RSNA physics tutorial for residents: physics of flat-panel fluoroscopy systems survey of modern fluoroscopy imaging; flat-panel detectors versus image intensifiers and more. RadioGraphics 2011; 31:591 602 19. Schueler BA. Clinical applications of basic x-ray physics principles. RadioGraphics 1998; 18:731 744; quiz, 729 20. Hansen J, Jurik AG, Fiirgaard B, Egund N. Optimisation of scoliosis examinations in children. Pediatr Radiol 2003; 33:752 765 AJR:204, February 2015 W131