Solid State Relays Zero Switching Types RGC Solid State Contactor 'U' Connection

Similar documents
Solid State Relay. Zero Switching Types RGC Solid State Contactor 'U' Connection. Product Description RGC 1 A 60 A 40 K G U _.

1-Phase Integrated Heatsink Zero Cross or Instant On Switching

Solid State Relay. Zero Switching Types RGC Solid State Contactor 'E' Connection. Product Description RGC 1 A 60 A 30 K K E _.

Solid State Relays Zero Switching Types RGC Solid State Contactor 'E' Connection

Solid State Relays Zero Switching Types Solid State Contactor

Solid State Relays 1-Phase Integrated Heatsink Zero Cross or Instant On Switching

Solid State Relays 1-Phase with Integrated Heatsink Zero Cross or Instant On Switching Types RGC Solid State Contactor 'E' Connection

Solid State Relays 1-Phase with Integrated Heatsink Soft Start Switching Types RGC1P..K..

Solid-state Contactor Specifications

Solid State Relays 1-Phase, Soft Start Switching Types RGS1P..K..

Solid-state Contactor Specifications

Solid State Relays 1-Phase, Zero Cross or Instant On Switching 25 AAC, 230 VAC with LED and Built-in Transil Types RF1A, RF1B

Solid State Relays 3-Phase with Integrated Heatsink Types 2 & 3 Pole

Solid State Relays 1-Phase with Integrated Heatsink Proportional Switching Controllers Types RGC1P..AA.., RGC1P..V..

Industrial, 2-Pole ZS Type RA2A

Solid State Relays 3-Phase with Integrated Heatsink Types RGC2, RGC3

Starting Torque Controller Technical Data

2PSS60A40 Solid State Relays 3-Phase with Integrated Heatsink

RP1A, RP1B. 1-phase PCB mount solid state relays. Main features. Description

RP1A, RP1B. 1-phase PCB mount solid state relays. Main features. Description

2-pole solid state relays

Solid State Relays 1-Phase, Proportional Switching Controllers Types RGS1P..AA.., RGS1P..V..

2-pole solid state relays

Solid State Relays 3-Phase with Integrated Heatsink Types RGC2, RGC3

Solid State Relays 1-Phase with Integrated Heatsink Zero Cross Switching, 1600 Vp Blocking Voltage Types RGH

08/07/2015

Type CP-S, CP-C & CP-A Switch mode

Solid State Relays SOLITRON MIDI Multi-Function Analog Switching Type RJ1P

Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink

08/07/2015

CP-T range Product group picture

05/09/2012

CP-T range Benefits and advantages

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT AC/DC Converter

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT12- AC/DC Converter

Electronic timer CT-TGD.22

SOLID STATE RELAY RATINGS

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

RN Thyristor Controllers

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Electronic timer CT-SDD.22

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Subject to changes 11/2003 Page 1/7

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Output Voltage* (nom.)(adjustable)

Power supply CP-E 24/20.0

38 Series - Relay interface modules A

38 Series - Relay interface modules A

02/11/2015

Zelio Control Measurement Relays

Power supply CP-E 24/2.5

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

Solid State Motor Contactor 3 Phase Motor Reversing Types REC2R

02/11/2015

celduc SILD Output : VAC 32A(*) Input : 3-32VDC - I<10mA Diagnostic : 30VDC - 100mA r e l a i s celpac P roud to serve you

02/11/2015

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

CP-E range Benefits and advantages

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

SELECTION GUIDE. BULLETIN 156 Solid-State Contactors

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

celduc SIM Phase angle controller Output : VAC 40A(*) Input : Analog 0-10V r e l a i s celpac

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Power supply CP-T 48/5.0 Primary switch mode power supply

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

77 Series - Modular Solid State Relay 5 A. Features. Timers and Monitoring relays

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

Power supply CP-T 48/20.0 Primary switch mode power supply

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

Electronic timer CT-SDS.22

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Semiconductor contactors, Solid-state relays

celduc SIL Phase angle controller Output : VAC 32A(*) Input : Analog 0-10V celpac r e l a i s Proud to serve you

Power supply CP-E 24/0.75

RE17LLBM asymmetrical flashing relay s V AC - solid state output

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

Power supply CP-D 24/1.3

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

Solid State Relays 3-Phase with Integrated Heatsink Proportional Switching Controllers

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Transcription:

Solid State Relays Zero Switching Types RGC Solid State Contactor 'U' Connection Product Width ranging from 17.mm up to 70mm Rated Operational voltage: Up to 600VAC Rated Operational current: Up to 8AAC @ 40 C Up to 6600A²s for I²t and 1200Vp blocking voltage Control voltages: 3-32 VDC, 20-27 VAC (24-1 VDC) IP20 protection Design according to EN/IEC60947-4-2, EN/IEC60947-4-3, EN/IEC62314, UL08, CSA 22-2 No. 14-10 Integrated voltage transient protection with varistor RoHS compliant Short circuit current rating: 100kA VDE approval Germanischer Lloyd approval 1 Product Description This new range of solid state contactors presents a unique opportunity to maximize efficiency in panel space and is an evolution of solid state switches for which Carlo Gavazzi is very well known. The nominal current ratings are at 40 C. The smallest width is 17.mm and is rated at 20 AAC. Power and control teminals allow for safe looping of cables. Voltage transient protection is standard across the output with a varistor. Specifications are stated at 2 C unless otherwise noted. 1. Germanischer Lloyd approval applicable only to models RGC...1KGU, RGC...20KGU and RGC...30KGU Ordering Key Solid State Relay Number of poles Switching Mode Rated Operational Voltage Control voltage Rated Operational current Connection type for control Connection type for power Connection configuration Option RGC 1 A 60 A 40 K G U _ Ordering Key 1Phase SSR Rated Voltage Control Voltage Rated Connection Connection Connection with heatsink Current 2 Control Power Configuration Option RGC1A: ZC 23: 230V +10% - 1%, 800Vp D: 3 or 4-32VDC 1: 20AAC K: Screw G: Box Clamp U: SSR P: Overtemperature RGC1B: IO 60: 600V +10% -1%, 1200Vp A: 20-27VAC, 24-1 VDC 20: 23AAC G: Box clamp protection 3 2. Refer to derating curves 3. Default control connection for RGC...P is Box Clamp. See connections specifications. 30: 30AAC 40: 40AAC 60: 60AAC : 8AAC Selection Guide (ZC= Zero Cross Switching, IO = Instant-On Switching, OTP= Over Temperature Protection ) Rated Output Blocking Connection Control Voltage Rated Operational Current @ 40 C Voltage Voltage Control/ Power 20 AAC 23 AAC 30 AAC 230VAC, ZC 800Vp Screw/Box Clamp 3-32VDC RGC1A23D1KGU RGC1A23D20KGU RGC1A23D30KGU Screw/Box Clamp 2-27VAC, 24-1VDC RGC1A23A1KGU RGC1A23A20KGU RGC1A23A30KGU 600VAC, ZC 1200Vp Screw/Box Clamp 4-32VDC RGC1A60D1KGU RGC1A60D20KGU RGC1A60D30KGU Screw/Box Clamp 20-27VAC, 24-1VDC RGC1A60A1KGU RGC1A60A20KGU RGC1A60A30KGU 600VAC, IO 1200Vp Screw/Box Clamp 4-32VDC RGC1B60D1KGU RGC1B60D20KGU RGC1B60D30KGU Rated Output Blocking Connection Control Voltage Rated Operational Current @ 40 C Voltage Voltage Control/ Power 40 AAC 40 AAC + OTP 60 AAC 60 AAC + OTP 230VAC, ZC 800Vp Screw/Box Clamp 3-32VDC RGC1A23D40KGU - RGC1A23D60KGU - Screw/Box Clamp 20-27VAC, 24-1VDC RGC1A23A40KGU - RGC1A23A60KGU - 600VAC, ZC 1200Vp Screw 3 /Box Clamp 4-32VDC 4 RGC1A60D40KGU RGC1A60D40GGUP RGC1A60D60KGU RGC1A60D60GGUP Screw 3 /Box Clamp 20-27VAC, 24-1VDC RGC1A60A40KGU RGC1A60A40GGUP RGC1A60A60KGU RGC1A60A60GGUP 600VAC, IO 1200Vp Screw/Box Clamp 4-32VDC RGC1B60D40KGU - RGC1B60D60KGU - Rated Output Blocking Connection Control Voltage Rated Operational Current @ 40 C Voltage Voltage Control/ Power 8 AAC + fan + OTP 230VAC, ZC 800Vp Box Clamp/Box Clamp -32VDC RGC1A23DGGUP 600VAC, ZC 1200Vp Box Clamp/Box Clamp -32VDC RGC1A60DGGUP Box Clamp/Box Clamp 20-27VAC, 24-1VDC RGC1A60AGGUP 600VAC, IO 1200Vp Box Clamp/Box Clamp -32VDC RGC1B60DGGUP 4. DC control voltage range for RGC..D..P is -32 VDC Specifications are subject to change without notice (07.06.2011) 1

Output Voltage Specifications RGC..23.. RGC..60.. Operational Voltage Range 24-240 VAC, 42-600 VAC, +10%, -1% on max +10% -1% on max Blocking Voltage 800Vp 1200 Vp Internal Varistor 27V 62V General Specifications Latching voltage (across L1-T1) Operational frequency range Power factor Finger Protection Control input status 20V 4 to 6Hz > 0. @ Vrated IP20 continuously Green LED, when control input is applied Pollution degree 2 (non-conductive pollution with possibilities of condensation) Over-voltage category III (fixed installations) Isolation Input to Output RGC... 4000 Vrms RGC...D..P 200 Vrms RGC...A..P 4000 Vrms Input and Output RGC... 4000 Vrms to case RGC...D..P 4000 Vrms RGC...A..P 4000 Vrms Input to Fan/ Alarm Output RGC...A..P 200 Vrms Output specifications (@ 2 C unless otherwise specified) RGC..1.. RGC..20.. RGC..30.. RGC..40.. RGC..60.. RGC... Rated operational current AC-1 rating @ Ta=2 C 20 AAC 2. AAC 30 AAC 47.4 AAC 70.4 AAC 8 AAC AC-1 rating @ Ta=40 C 20 AAC 23 AAC 30 AAC 40 AAC 60 AAC 8 AAC AC-3a rating @ Ta=40 C AAC AAC 8 AAC 13 AAC 14.8 AAC 18 AAC Number of motor starts (x:6, Tx:6s, F:0%) at 40 C 6 30 30 30 30 30 30 Min. operational current 10 maac 10 maac 20 maac 400 maac 400 maac 400 maac Rep. overload current - (Motor Rating) PF = 0.4-0. UL08: T AMB=40 C, t =1s, t OFF=9s, 0cycles 60 AAC 60 AAC 84 AAC 126 AAC 144 AAC 168 AAC Maximum transient surge current (I TSM) 32 Ap 32 Ap 600 Ap 800Ap 800Ap 110Ap Maximum off-state leakage current 3 ma 3 ma 3 ma 3 ma 3 ma 3 ma I²t (10ms) Minimum 2 A²s 2 A²s 1800 A²s 3200A²s 3200A²s 6600A²s Crititcal dv/dt (@ Tj init = 2 C) 1000 V/us 1000 V/us 1000 V/us 1000 V/us 1000 V/us 1000 V/us. See derating curves 6. Overload current profle definition: x: multiple of AC3a rating, Tx: duration of current surge, F: duty cycle Overtemperature alarm specifications for RGC...P RGC..D..P RGC..A..P Output type PNP open collector Potential Free Normal state Closed Closed Maximum current rating 0 madc 0 madc Rated voltage (EN61131-2: 2003) 7,8, Ua 24VDC -1%, +20% 24VDC -1%, +20% Rated voltage, Us RGC...DGGUP 24VDC ± 10% N/A Fan rating, Uf RGC...AGGUP N/A 24VDC ±10%, 0mA nominal Alarm voltage drop Typical 2.8VDC 1.8VDC Maximum 4VDC 3.VDC Visual Indication Continous Red LED Continous Red LED Reverse polarity protection 24VDC 24VDC 7: DC supply for alarm signal should be supplied from a Class 2 power source 8: Maximum voltage to be applied between 11+ and 12- (Ua) terminals should be 3VDC maximum with reference to A2-2 Specifications are subject to change without notice (07.06.2011)

Input specifications RGC..D.. 9 RGC..A.. Control voltage range 10 RGC..23.. 3-32 VDC 20-27 VAC, 24 (-10%) - 1 VDC RGC..60.. 4-32 VDC 20-27 VAC, 24 (-10%) - 1 VDC RGC...P (Uc) - 32 VDC 20-27 VAC, 24 (-10%) - 1 VDC Pick-up voltage RGC..23.. 3.0 VDC 20 VAC/DC RGC..60.. 3.8 VDC RGC...P VDC 20 VAC/ 24VDC Drop-out voltage 1 VDC VAC/DC Maximum Reverse voltage 32 VDC - Response time pick-up ZC (RGC1A..) 0. cycle + 00µs @ 24VDC 2 cycles @ 230VAC/110VDC Response time pick-up IO (RGC1B..) 30µs @ 24 VDC N/A Response time drop-out 0. cycle + 00µs @ 24VDC 0. cycle + 40ms @ 230VAC/ 110VDC Input current @ 40 C See diagrams below See diagrams below 9. DC control to be supplied by class 2 power source 10. For GL approved models control range for RGC1.23D.. is 4-32 VDC and for RGC1.60D.. -32 VDC RG..A.. 40mA RGC1.. A : input current vs input voltage 3mA 30mA 2mA 20mA RGC.. A 1mA 10mA ma RGC..A..P (Active Protection) RGC..A..P (Normal Operation) 0mA 0VAC 0VAC 100VAC 10VAC 200VAC 20VAC 300VAC RGC1.. A : input current vs input voltage 40mA 3mA RGC..A..P (Active Protection) 30mA 2mA 20mA 1mA RGC.. A 10mA ma RGC..A..P (Normal Operation) 0mA 0VDC 0VDC 100VDC 10VDC 200VDC 20VDC Specifications are subject to change without notice (07.06.2011) 3

Input specifications (cont.) RG..D.. 2.0mA RGC..D..P (Normal Operation) A1 Characteristics: DC input current vs Input voltage x 20.0mA 1.0mA RGC..D..P (Active Protection) 10.0mA.0mA 2V 4V 6V 8V 10V 12V 14V 16V 18V 20V 22V 24V 26V 28V 30V 32V 34V x: Input currents for RGC1..D1, RGC1..D20, RGC1..D30, RGC1..D40, RGC1..D60 20.0mA IN1 Characteristics: DC input current vs Input voltage y x 1.0mA RGC..DGGUP (Normal Operation) 10.0mA.0mA RGC..DGGUP (Active Protection) 0.0mA 2V 4V 6V 8V 10V 12V 14V 16V 18V 20V 22V 24V 26V 28V 30V 32V 34V y: input currents valid only for RGC1..DGGUP 4 Specifications are subject to change without notice (07.06.2011)

Motor Ratings: HP (UL08) / kw (IEC60947-4-2) @ 40 C 11 VAC 230 VAC 400 VAC 480 VAC 600 VAC RGC..1 ⅓HP / 0.18kW 1HP / 0.37kW 2HP / 0.7kW 3HP / 1.1kW 3HP / 1.kW RGC..20 ½HP / 0.18kW 1-½HP / 0.37kW 2HP / 0.7kW 3HP / 1.1kW 3HP / 1.kW RGC..30 ¾HP / 0.37kW 2HP / 1.1kW 3HP / 1.kW HP / 2.2kW HP / 3.7kW RGC..40 1HP / 0.6kW 3HP / 1.kW HP / 2.2kW HP / 3.7kW 7-½HP / 4kW RGC..60 1-½HP / 0.6kW 3HP / 1.kW HP / 3kW 7-½HP / 4kW 10HP / 4kW RGC..GGUP 2HP / 0.7kW HP / 1.kW 7-½HP / 4kW 10HP / 4kW 1HP /.kw Detailed Over temperature Alarm Procedure (for RGC...P) ALARM Signal and Fan (applicable ALARM to RGC..DGGUP) Signal and FAN ALARM Signal only ALARM Signal only START START Is Chip temperature > 11 C? N Chip temperature limit reached? N Y Y FAN: SSR output: Red LED: Alarm Signal: OFF Chip temperature < 8 C? N Chip temperature limit reached? N Chip temperature < 80 C? N Y FAN: OFF SSR output: Red LED: Alarm Signal: Y OFF Y SSR output: Red LED: OFF Alarm Signal: OFF Chip temperature < 80 C? N Y SSR output: Red LED: OFF Alarm Signal: OFF FAN: OFF CAUTI Alarm condition resets whenever the voltage signal is removed from terminal A1 (+) In the case of RGC...DGGUP, if the voltage signal is not applied across A1(+) and A2 (-) terminals, the overtemperature detection and functionality is lost (including fan operation and alarm signalling) In the case of RGC1A60AGGUP it is necessary to supply IN2 and IN3 with 24VDC for fan operation. Alarm procedure for RGC1A60AGGUP follows Alarm signal only flow since fan is continously operating. Alarm condition automatically resets LY when power semiconductor temperature < 80 C Temperatures indicated are typical figures. Specifications are subject to change without notice (07.06.2011)

Output Power Dissipation C WP 08 R G C 1xyyz. C WP 1R G C 1.. power C WP x dis s ipation C WP vs 2 load c urrent C WP 30 C WP 30 C WP 41 C urrent R G C 1..20 R G C 1..30 R G C 1..30 R G H1..20 R G C 1..40 R G C 1..60 R G C 1.. 100W 0 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1 0.64 0.624 0.624 0.6 0.630 0.630 0.78 2 1.411 1.347 1.347 1.23 1.342 RGC1..60 1.342 1.246 3W 2.216 2.111 2.111 1.91 2.0 2.0 1.91 4 3.08 2. 2. 2.700 2.862 2.862 2.682 R RGC1..GGUP G C. 80W 3.931 3.723 3.723 3.478 3.6 3.6 3.434 6 4.832 4.62 4.62 4.281 4.464 4.464 4.203 7.79.419.419.10.288.288 4.988 8 70W 6.710 6.293 6.293.91 6.127 6.127.787 9 7.684 7.183 7.183 6.816 6.978 6.978 6.600 10 60W 8.680 8.088 8.088 7.699 RGC1..40 R G C 1..40 7.841 7.841 7.424 11 9.697 9.008 9.008 8.600 8.71 8.71 8.261 12 10.736 9.940 9.940 9.18 9.601 9.601 9.108 0W 13 11.79 10.886 10.886 10.43 10.497 10.497 9.966 14 12.874 11.84 11.84 11.404 11.402 11.402 10.834 1 40W 13.973 12.816 12.816 12.371 12.318 12.318 11.711 16 1.091 13.799 13.799 13.33 13.243 13.243 12.99 17 16.229 14.793 RGC1..30 14.793 14.31 14.178 14.178 13.49 30W 18 17.38 RGC1..20 1.799 1.799 1.363 1.121 1.121 14.401 19 18.60 16.817 16.817 16.391 16.074 16.074 1.316 20W 19.74 RGC1..1 17.84 17.84 17.432 17.03 17.03 16.239 21 20.96 18.88 18.88 18.489 18.00 18.00 17.171 22 22.19 19.93 19.93 19.9 18.983 18.983 18.112 10W 23 23.444 20.996 20.996 20.643 19.969 19.969 19.060 24 24.710 22.067 22.067 21.742 20.964 20.964 20.017 20W 2.993 23.149 23.149 22.84 21.967 21.967 20.982 26 0A A27.29 10A 1A 20A 24.2402A 30A24.240 3A 40A 4A 23.980 0A A 22.978 60A 6A 70A 22.978 7A 80A 21.9 8A A 27 28.614 2.343 2.343 L oad c urrent 2.119 in A A C rms 23.997 23.997 22.93 28 29.91 26.4 26.4 26.272 2.024 2.024 23.924 Power dissiaption in W Current Derating (UL08) 80 RGC.. 70 Load Current in AAC 60 0 40 30 20 RGC.. 30 RGC.. 20 RGC.. 1 RGC.. 60 RGC.. 40 10 0 0 10 20 30 40 0 60 70 80 Surrounding Ambient Temperature in C RGC...P models max. operating temperature is + 70 C 6 Specifications are subject to change without notice (07.06.2011)

Derating vs. Spacing Curves RGC.. 1.. 2 Load Curre ent in AAC 20 1 10 0mm mm 0 0 10 20 30 40 0 60 70 80 Surrounding Ambient Temperature in C 10mm & over RGC.. 20.. 3 Load Curre ent in AAC 30 2 20 1 10 0 0 10 20 30 40 0 60 70 80 Surrounding Ambient Temperature in C 0mm mm 10mm 20mm & over RGC.. 30.. 3 Load Curren nt in AAC 30 2 20 0mm mm 1 10mm & over 10 0 10 20 30 40 0 60 70 80 Surrounding Ambient Temperature in C Stand alone unit Specifications are subject to change without notice (07.06.2011) 7

Derating vs. Spacing Curves (cont.) RGC.. 40.. 0 4 nt in AAC Load Curre 40 3 30 2 20 1 10 0 10 20 30 40 0 60 70 80 Surrounding Ambient Temperature in C 0mm 10mm & over Stand alone unit RGC.. 60.. 70 Load Curre ent in AAC 6 60 0 4 40 3 30 0 10 20 30 40 0 60 70 80 Surrounding Ambient Temperature in C 0mm 10mm & over Stand alone unit RGC.. GGUP Load Curre ent in AAC 8 80 7 70 6 60 0 0 10 20 30 40 0 60 70 Surrounding Ambient Temperature in C 0mm 10mm & over Stand alone unit 8 Specifications are subject to change without notice (07.06.2011)

Agency Approvals and Conformances Conformance IEC/EN 62314 IEC/EN 60947-4-2 IEC/EN 60947-4-3 Agency Approvals Short Circuit Current Rating UL08 Listed (E172877) cul Listed (E172877) VDE (0660-109) GL 12 100kA, UL08 Electromagnetic Compatibility EMC Immunity IEC/EN 61000-6-2 Electrostatic Discharge (ESD) Immunity IEC/EN 61000-4-2 Air discharge, 8kV Performance Criteria 1 Contact, 4kV Performance Criteria 1 Electrical Fast Transient (Burst) Immunity IEC/EN 61000-4-4 Output: 2kV, khz Performance Criteria 1 Input: 1kV, khz Performance Criteria 1 Electrical Surge Immunity IEC/EN 61000-4- (for RGC...U) Output, line to line, 1kV Performance Criteria 1 Output, line to earth, 2kV Performance Criteria 1 Input, line to line, 1kV Performance Criteria 2 Input, line to earth, 2kV Performance Criteria 2 Electrical Surge Immunity IEC/EN 61000-4- (for RGC...UP) Output, line to line, 1kV Performance Criteria 1 Output, line to earth, 2kV Performance Criteria 1 DC lines, line to line, 00V Performance Criteria 2 DC lines, line to earth, 00V Performance Criteria 2 Signal lines, line to earth, 1kV Performance Criteria 2 Radiated Radio Frequency Immunity IEC/EN 61000-4-3 10V/m, 80-1000 MHz Performance Criteria 1 10V/m, 1.4-2 GHz Performance Criteria 1 3V/m, 2-2.7 GHz Performance Criteria 1 Conducted Radio Frequency IEC/EN 61000-4-6 Immunity 10V/m, 0.1-80 MHz Performance Criteria 1 Voltage Dips Immunity IEC/EN 61000-4-11 0% for 10ms/20ms, Performance Criteria 2 40% for 200ms Performance Criteria 2 70% for 00ms Performance Criteria 2 Voltage Interruptions Immunity IEC/EN 61000-4-11 0% for 000ms Performance Criteria 2 EMC Emission IEC/EN 61000-6-4 Radio Interference Voltage Emission (Conducted) IEC/EN 011 0.1-30MHz Class A (industrial) with filters - see filter information IEC/EN 60947-4-2, 60947-4-3 Class A (no filtering needed) Radio Interference Field Emission (Radiated) IEC/EN 011 30-1000MHz Class A (industrial) Environmental Specifications Operating Temperature 11 Storage Temperature RoHS (2002/9/EC) Impact resistance (EN01, EN61373) Vibration resistance (2-100Hz, IEC60068-2-26, EN01, EN61373) Relative humidity UL flammability rating (housing) -40 C to 80 C (-40 F to +176 F) -40 C to 100 C (-40 F to +212 F) Compliant 1/11 g/ms 2g per axis 9% non-condensing @ 40 C UL 94 V0 11. Operating temperature range for RGC..P (overtemperature protection) is -30 C to 70 C (-22 F to 18 F) 12. Applicable to models RGC1...1KGU, RGC1...20KGU and RGC1...30KGU Specifications are subject to change without notice (07.06.2011) 9

Filtering - EN / IEC 011 Class A compliance (for class B compliance contact us) Part Number Suggested filter for compliance Maximum Heater current RGC1A23..1 68 nf / 27V / X1 20A RGC1A23..20 68 nf/ 27 V / X1 20A RGC1A23..30 220 nf / 27V / X1 30A RGC1A23..40 220 nf / 27V / X1 30A 330 nf / 27V / X1 4A RGC1A23..60 220 nf / 27V / X1 30A 330 nf / 27V / X1 4A RGC1A23..GGUP 330 nf / 27V / X1 3A 470 nf / 27V / X1 6A RGC1A60..1 100 nf / 760V / X1 20A RGC1A60..20 100 nf / 760V / X1 20A RGC1A60..30 220 nf / 760V / X1 30A RGC1A60..40 220 nf / 760V / X1 2A 330 nf / 760V / X1 4A RGC1A60..60 220 nf / 760V / X1 2A 330 nf / 760V / X1 4A RGC1A60..GGUP 330 nf / 760V / X1 40A 470 nf / 760V / X1 6A Note: Control input lines must be installed together to maintain products' susceptability to Radio Frequency interference. Use of AC solid state relays may, according to the application and the load current, cause conducted radio interferences. Use of mains filters may be necessary for cases where the user must meet E.M.C requirements. The capacitor values given inside the filtering specification tables should be taken only as indications, the filter attenuation will depend on the final application. Performance Criteria 1: No degradation of performance or loss of function is allowed when the product is operated as intended. Performance Criteria 2: During the test, degradation of performance or partial loss of function is allowed. However when the test is complete the product should return operating as intended by itself. Performance Criteria 3: Temporary loss of function is allowed, provided the function can be restored by manual operation of the controls. Filter Connection Diagrams 1 Phase 3 Phase L1 L2 L3 SSR SSR SSR LOAD N R d R d R d R d = 1MΩ, 0.W Filter has to be connected across both LOAD and SSR 10 Specifications are subject to change without notice (07.06.2011)

Connection Diagram (No OTP) AC Controlled DC Controlled A1 ~ 1 L1 A2-2 T1 In AC controlled types only (RG..A..) a varistor is placed across A1/A2 terminals. In DC controlled types only (RG..D..) a diode is placed in series with the control circuit for protection against reverse biased connection. Connection Diagram (with OTP) 0V A2-0V FAN- FAN+ (Black) (Red) A2- IN3 IN2 Uc A2- UC FAN- (Black) A2- IN3 IN2 FAN+ (Red) - Uf + A1+ 12- Uc Alarm Out. 11+ +Ua 0V A1+ IN1 OUT Us IN1 Uc Alarm Out. A1+ 12- Uc Alarm Out. 11+ +Ua -Ua A1+ 12- Uc Alarm Out. 11+ +Ua 0V -Ua RGC1...D40GGUP RGC1...D60GGUP Uc: - 32 VDC Ua: max. 3VDC Alarm Output: max. 0mA RGC1...DGGUP Uc: - 32 VDC Us: 24 VDC Alarm Output: max. 0mA RGC1...A40GGUP RGC1...A60GGUP Uc: 24-27 VAC 24-1 VDC Ua: max. 3 VDC Alarm Output: max. 0mA RGC1...AGGUP Uc: 24-27 VAC 24-1 VDC Ua: max. 3 VDC Alarm Output: max. 0mA Uf: 24 VDC Specifications are subject to change without notice (07.06.2011) 11

Terminal Layout and Dimensions RGC...1KGU 17.8 9. 98. 1 3. A2 A1 106 98 RG Solid State Switch 17.8 9. 136 1 3. 43.8 43.8 3.2 A1 L1 A2 T1 RGC...20KGU RG Solid State Switch A2 A1 A1 L1 A2 T1 106 98 3.2 RGC...30KGU 22. 9. 136 1 3. A2 A1 43.8 RG Solid State Switch A1 L1 A2 T1 106 98 3.2 1/L1: Supply connection 2/T1: Load connection A1 (+): Positive control signal A2 (-): Control ground * Housing width tolerance +0.mm, -0mm as per DIN43880 All dimensions in mm 12 Specifications are subject to change without notice (07.06.2011)

Terminal Layout and Dimensions RGC...40KGU 3.6 27.2 136 1 43.7 43.8 A2 A1 RG Solid State Switch A1 L1 A2 T1 106 98 3.2 RGC...60KGU 69.1 3.6 27.2 136 1 43.7 RG Solid State Switch A2 A1 A1 L1 A2 T1 106 98 43.8 3.2 140.38 1/L1: Supply connection 2/T1: Load connection A1 (+): Positive control signal (Positive supply in case of RGC1A..DGGUP) A2 (-): Control ground IN1: Control signal (only for RGC1A.. DGGUP) IN2: Fan + supply (only for RGC1A60AGGUP) IN3: Fan - supply (only for RGC1A60AGGUP) 11 + : Alarm output (+) OUT, 12 - : Alarm output (-) * Housing width tolerance +0.mm, -0mm as per DIN43880 All dimensions in mm Specifications are subject to change without notice (07.06.2011) 13

GND FAN - FAN + SUPPLY CTROL ALARM SUPPLY ALARM ALARM SUPPLY ALARM ALARM RGC...U Terminal Layout and Dimensions (cont.) RGC...40GGUP 3.6 27.2 163 78 43.7 GRD A2 FAULT 106 98 60. RG Solid State Switch CTROL A1+ 11+ RGC...60GGUP 69.1 3.6 27.2 163 78 43.7 GRD A2 FAULT 106 98 60. RG Solid State Switch CTROL A1+ 12-12- 11+ RGC...GGUP 69.1 3.6 27.2 163 73 73 43.6 A2 IN3 FAULT IN2 RG Solid State Switch CTROL 126 98 60. A1 IN1 OUT RGC..DGGUP RGC..AGGUP 89.8 1/L1: Supply connection 2/T1: Load connection A1 (+): Positive control signal (Positive supply in case of RGC1A..DGGUP) A2 (-): Control ground IN1: Control signal (only for RGC1A.. DGGUP) IN2: Fan + supply (only for RGC1A60AGGUP) IN3: Fan - supply (only for RGC1A60AGGUP) 11 + : Alarm output (+) OUT, 12 - : Alarm output (-) * Housing width tolerance +0.mm, -0mm as per DIN43880 All dimensions in mm 14 Specifications are subject to change without notice (07.06.2011)

Connection Specifications POWER CNECTIS: 1/L1, 2 /T1 Use 7 C copper (Cu) conductors RGC..1.KGU; RGC..20.KGU ; RGC..30.KGU RGC..40.GU.; RGC..60.GU.; RGC..GGUP Stripping Length (X) 12mm 11mm Connection type M3. screw with box clamp M screw with box clamp Rigid (Solid & Stranded) UL/ cul rated data X Flexible with end sleeve 1 x 1..6 mm 2 1 x 6..2mm 2 1 x 18.. 10 AWG 1 x 10...3 AWG 1 x 0...2.mm 2 1 x 2...16mm 2 1 x 20.. 14 AWG 1 x 14.. 6 AWG Flexible without end sleeve 1 x 1.. 4mm 2 1 x 4.. 2mm 2 1 x 18.. 12 AWG 1 x 12.. 3 AWG Torque specifications 2 Nm (17.7 in-lb). 2. Nm (22 in-lb). M3., Pozidriv 2 M, Pozidriv 2 Protective Earth Connection RGC..1, 20: M4, 1.Nm (13.3 in-lb) RGC..30, 40, 60, : M, 1.Nm (13.3 in-lb) Note: Protective Earth connection must be connected whenever the product is intended to be used in Class 1 applications according to EN/IEC 61140. CTROL CNECTIS: A1(+), A2(-) Use 60/7 C copper (Cu) conductors RGC..KGU Torque specifications 0. Nm (4.4 in-lb); M3, Pozidriv 1 Stripping Length (X) Rigid (Solid & Stranded) UL/ cul rated data Flexible with end sleeve X 8mm 2 x 0...2.mm 2 1 x 0...2.mm 2 2 x 18..12 AWG 1 x 18..12 AWG 2 x 0...2.mm 2 1 x 0...2.mm 2 2 x 18..12AWG 1 x 18..12AWG CTROL CNECTIS: A1(+), A2(-), IN1, IN2, IN3, 11 (+), 12(-), OUT Use 60/7 C copper (Cu) conductors RGC...GGUP Torque specifications 0. Nm (4.4 in-lb); M3, Pozidriv 1 Stripping Length (X) 6mm 13mm Rigid (Solid & Stranded) UL/ cul rated data X Flexible with end sleeve 2 x 0...2.mm 2 1 x 0.2..2.mm 2 2 x 18..12 AWG 1 x 24..12 AWG 2 x 0...2.mm 2 1 x 0.2..2.mm 2 2 x 18..12AWG 1 x 24..12AWG Specifications are subject to change without notice (07.06.2011) 1

Installation Instructions Y1 = mm X = X = Refer to product Derating vs. Spacing widthcurves Y2 = 100mm Short Circuit Protection Protection Co-ordination, Type 1 vs Type 2: Type 1 protection implies that after a short circuit, the device under test will no longer be in a functioning state. In type 2 co-ordination the device under test will still be functional after the short circuit. In both cases, however the short circuit has to be interrupted. The fuse between enclosure and supply shall not open. The door or cover of the enclosure shall not be blown open. There shall be no damage to conductors or terminals and the condcutors shall not separate from terminals. There shall be no breakage or cracking of insulating bases to the extent that the integrity of the mounting of live parts is impaired. Discharge of parts or any risk of fire shall not occur. The product variants listed in the table hereunder are suitable for use on a circuit capable of delivering not more than 100,000A rms Symmetrical Amperes, 600 Volts maximum when protected by fuses. Tests at 100,000A were performed with Class J fuses, fast acting; please refer to the table below for maximum allowed ampere rating of the fuse. Use fuses only. Co-ordination type 1 (UL08) Part No. Max. size [A] Class Current [ka] Voltage [VAC] RGC..1 30 J 100 Max. 600 RGC..20 30 J 100 Max. 600 RGC..30 30 J 100 Max. 600 RGC..40 30 J 100 Max. 600 RGC..60 30 J 100 Max. 600 RGC..GGUP 40 J 100 Max. 600 Co-ordination type 2 (IEC EN 60947-4-2/ -4-3) Part No. Ferraz Shawmut Siba Current [ka] Voltage [VAC] Max size [A] Part number Max size [A] Part number RGC..1 32 6.9xx CP URD 22x8/32 32 0 142 06.32 100 Max. 600 RGC..20 32 6.9xx CP URD 22x8/32, (xx=00 or 21) 32 0 142 06.32 100 Max. 600 RGC..30 40 A70QS40-4 32 0 142 06.2 100 Max. 600 RGC..40 70 A70QS70-4 63 0 194 20.63 100 Max. 600 RGC..60 A70QS-4 80 0 194 20.80 100 Max. 600 RGC..GGUP 100 A70Q100-4 100 0 194 20.100 100 Max. 600 16 Specifications are subject to change without notice (07.06.2011)

Protection with Miniature Circuit Breakers Solid State Relay Model no. for Model no. for Wire cross Minimum length of type Z - type M. C. B. B - type M. C. B. sectional area [mm2] Cu wire conductor [m] 13 (rated current) (rated current) RGC..1, RGC..20 S201 - Z4 (4A) S201 - B2 (2A) 1.0 21.0 S201 - Z6 UC (6A) S201 - B2 (2A) 1.0 21.0 1. 31. RGC..30 S201 - Z10 (10A) S201-B4 (4A) 1.0 7.6 1. 11.4 2. 19.0 S201 - Z16 (16A) S201-B6 (6A) 1.0.2 1. 7.8 2. 13.0 4.0 20.8 S201 - Z20 (20A) S201-B10 (10A) 1. 12.6 2. 21.0 S201 - Z2 (2A) S201-B13 (13A) 2. 2.0 4.0 40.0 S202 - Z2 (2A) S202-B13 (13A) 2. 19.0 4.0 30.4 RGC..40 S201 - Z2 (2A) S201-B13 (13A) 2. 7.0 4.0 11.2 6.0 16.8 RGC..60 S201 - Z2 (2A) S201-B13 (13A) 2. 7.0 4.0 11.2 6.0 16.8 RGC..GGUP S201 - Z20 (20A) S201-B10 (10A) 1. 4.2 2. 7.0 4.0 11.2 S202 - Z20 (20A) S202-B10 (10A) 1. 1.8 2. 3.0 4.0 4.8 S201 - Z32 (32A) S201-B16 (16A) 2. 13.0 4.0 20.8 6.0 31.2 S202 - Z32 (32A) S202-B16 (16A) 2..0 4.0 8.0 6.0 12.0 10.0 20.0 S202 - Z0 (0A) S202-B2 (2A) 4.0 14.8 6.0 22.2 10.0 37.0 13. between MCB and SSR Relay (including return path which goes back to the mains). Note: A prospective current of 6kA and a 230/400V power supply system is assumed for the above suggested specifications. For cables with different cross section than those mentioned above please consult Carlo Gavazzi's Technical Support Group. Specifications are subject to change without notice (07.06.2011) 17