AIM & THURLBY THANDAR INSTRUMENTS

Similar documents
AIM & THURLBY THANDAR INSTRUMENTS

TG550 AIM & THURLBY THANDAR INSTRUMENTS. 5MHz function generator with sweep

AIM & THURLBY THANDAR INSTRUMENTS

AIM & THURLBY THANDAR INSTRUMENTS. DC Electronic Load, 80A, 80V, 300W

TG1010A AIM & THURLBY THANDAR INSTRUMENTS. 10MHz programmable DDS function generator. Direct Digital Synthesis

LFR: flexible, clip-around current probe for use in power measurements

AIM & THURLBY THANDAR INSTRUMENTS

Experiment 1: Instrument Familiarization (8/28/06)

Experiment 1: Instrument Familiarization

The practicalities of measuring fast switching currents in power electronics using Rogowski probes

FISCHER CUSTOM COMMUNICATIONS, INC.


Flexible AC current probes

DataSheet SIGLENT Series Probe

RCTrms Technical Notes

Improving the immunity of sensitive analogue electronics

1 Introduction. Webinar sponsored by: Cost-effective uses of close-field probing. Contents

PHV RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

Current Probes. User Manual

Implementing Automated Oscilloscope Calibration Systems

Signal and Noise Measurement Techniques Using Magnetic Field Probes

Design Engineering Notes and Tips

EE 241 Experiment #4: USE OF BASIC ELECTRONIC MEASURING INSTRUMENTS, Part III 1

Current clamps for AC current

Multi-function Gain-Phase Analyzer (Frequency Response Analyzer) Model 2505

P331-2 set ESD generator (IEC )

Current transducer FHS 40-P/SP600

BumbleBee. High Voltage Differential Probe Ord.-No: Features:

How to Select the Right Current Probe APPLICATION NOTE

PMT 221A. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design. Interchangeable Spring Contact Tip

World-Class Accuracy & Measurement Range (40 Conventional Models)

Operation Manual for. Mag585 and Mag592 Low Radiation Three-Axis Magnetic Field Sensors

Supplied in carry case with additional accessories The PHV 1000-RO is a 400 MHz, standard sized, 100:1 passive probe designed for instruments

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

CPCO Series (160mm) DC-AC Current Probe, Clamp On ±4000A, ±8000A, ±12000A,

PML 711A-RO High impedance passive probe Features:

CWT Ultra Mini Technical Notes

Cost-Effective Traceability for Oscilloscope Calibration. Author: Peter B. Crisp Head of Metrology Fluke Precision Instruments, Norwich, UK

INSTRUCTIONS FOR USE

AN-1011 APPLICATION NOTE

Data Sheet. Hall effect transducers, current and voltage

Explanation of options and accessories for the GP102 and GP102 -PAV

Trees, vegetation, buildings etc.

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

supplies and frequency converters. BumbleBee is also very effective in fast transient measurements

CPCO Series DC-AC Current Probe, Clamp On, 160mm, ±1000A ±2000A ±4000A ±8000A ±12000A, ±16000A

Measurement and Analysis for Switchmode Power Design

PMT 211A-RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

The design of Ruthroff broadband voltage transformers M. Ehrenfried G8JNJ

Voltage Transient Emission Test

TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD.

OPERATING AND MAINTENANCE MANUAL

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Appendix A: Specifications

Operation Manual for. Mag690 Three-Axis Fluxgate Magnetometer.

RCTi and RCTi-3ph Technical Notes

MODEL 9050 EXTENDED SPECIFICATIONS. 50ppm TRANSPORTABLE CALIBRATOR

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Voltage Probe Manual and Data North Star High Voltage, Inc. Rev January 2016

Voltage Sensors URV5-Z

Operation Manual for. Mag648 and Mag649 Low Power Three-Axis Magnetic Field Sensors

As all PMK probes the PML 751-RO features CeramCore TM technology. The entire probe

Current clamps for AC current

Probe Considerations for Low Voltage Measurements such as Ripple

Operator s Manual. PP022 Passive Probe

Wide-band Models from DC to 100 MHz

Techniques for Investigating the Effects of ESD on Electronic Equipment Douglas C. Smith

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

PHV 1000-RO. High impedance passive probe. Features: CeramCore TM hybrid probe. Modular construction. Coaxial design

Power Sensors Ltd. PQube 3 AC Analyzer IEC Class 0,2 S Accuracy Compliance Report

Wide-band Models from DC to 100 MHz

AC Current Probes CT1 CT2 CT6 Data Sheet

Integrated Inductive Component Reduces Radiated Emissions in Power Applications

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

ECE 2274 Lab 2 (Network Theorems)

Laplace Instruments Ltd LAPLACE INSTRUMENTS LTD RF300. Large Loop Antenna. (Van Leen Loop) 2 metre diameter. Mk II-A. USER MANUAL Ver 2.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Magnetic-Field Test System / Low-Frequency Test System for Emission and Immunity Tests / MTS-800

MG7095 Tunable S-Band Magnetron

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

ECE3204 D2015 Lab 1. See suggested breadboard configuration on following page!

MGA Magnetic field system. DC khz

DECLARATION OF CONFORMITY

Electro-Magnetic Interference and Electro-Magnetic Compatibility (EMI/EMC)

TIA-525 Optical/Electrical Converter Operating Instructions

Broadband Current Probe Series Operation Manual

AC/DC Resistance Standard DRR-112

LVDS Flow Through Evaluation Boards. LVDS47/48EVK Revision 1.0

Passive High Voltage Probes P5100A-TPP0850-P5122-P5150-P6015A Datasheet

NI PXI-2530 Specifications

Operation Manual for. Mag690 Three-Axis Fluxgate Magnetometer

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

Oscilloscope Probes and Accessories

9 Specifications. Specifications NOMINAL CHARACTERISTICS

User s Manual Current Probe. IM E 2nd Edition IM E

High Voltage Differential Probes HVD3605A, HVD3206A HVD310xA

VE7CNF - 630m Antenna Matching Measurements Using an Oscilloscope

400 MHz Passive High-Voltage Probe R&S RT-ZH

Transcription:

AIM & THURLBY THANDAR INSTRUMENTS I-prober 520 positional current probe Unique technology enabling current measurement in PCB tracks bandwidth of DC to 5MHz, dynamic range of 10mA to 20A pk-pk useable with any normal oscilloscope, safety rated to 300V Cat II investigates waveforms in any conductor including ground planes aimtti.com aimtti.co.uk aimtti.us

Aim I-prober 520 - a breakthrough in current measurement technology! A technology breakthrough The I-prober 520 achieves something radically new. It can observe and measure currents in PCB tracks and other conductors where conventional current probes can t be used. This includes captive wires into components, the legs of integrated circuits, and PCB ground planes. Conventionally, current can only be measured by either breaking the circuit to insert a shunt resistor, or by surrounding the conductor by a loop of magnetic material as in a standard current probe. The I-prober 520 enables currents, from dc up to 5MHz, to be observed and measured simply by placing its insulated tip onto the conductor. Key Features Current measurement from insulated probing of conductor Suitable for observation and measurement of current in PCB tracks, component leads and ground planes Wide dynamic range of 10mA to 20A peak to peak Wide bandwidth of DC to 5MHz Low noise figure equivalent to <6mA rms at full bandwidth Safety rated to 300V Cat II (600V Cat I) Suitable for connection to any oscilloscope High accuracy general purpose H-field probe Converts to standard closed magnetic circuit current probe Unique Capabilities No requirement to break or surround the conductor Observe and measure currents in PCB tracks directly Minimal disturbance to circuit conditions through very low insertion impedance and stray capacitance Useable in confined and difficult to access spaces Measures current into surface mount components, IC legs and short component leads Can observe currents flowing within ground planes Useable on high voltage conductors and in high temperature areas

Observe & measure currents in PCB tracks, captive component leads & ground planes Current measurement techniques True measurement of current requires the circuit to be broken and a current measurement device inserted (e.g. a shunt that converts current to voltage). However, breaking the circuit is impractical in many circumstances and, in the case of PCB tracks, may be impossible. Closed magnetic circuit current measurement DC capable current probes do not measure current, they measure field density. Current flowing through a conductor creates an H field which is directly proportional to the current. If a conductor is surrounded by a closed magnetic circuit of high Mu material the whole of the field is captured by the magnetic circuit and the field density can be scaled to represent current. Conventional current probes achieve this by concentrating the field into a gap within a loop of high Mu material. The field is then measured by a field sensor inserted into the gap, often a Hall effect device. Alternatively ac current can be measured by transformer action whereby the loop of magnetic material creates a one turn primary from the conductor that is enclosed. Hybrid devices typically use a field sensor for dc and low frequencies plus a transformer for higher frequencies. Normally the probe provides a method of mechanically splitting the magnetic circuit to enable the conductor to be inserted. The position of the conductor within the loop has relatively little effect upon the measurement. Illustration shows high performance current probes from Tektronix Inc. PCB track current measurement Measuring current in a PCB track presents particular difficulties because it normally not possible either to break the track or to enclose it within a magnetic circuit. Typically engineers have to guess at the current flowing in a track from voltage measurements made in other parts of the circuit.. As electronic design moves towards ever higher densities, development omits the bread board stage and goes straight to PCB design. The inability to observe and measure currents in a circuit under development can pose a serious problem for engineers. Engineering a Solution The only practical way to observe and measure the current in a PCB track is by sensing the field in very close proximity to the track. We refer to this type of current probe as a positional current probe. To achieve a calibrated measurement, the field sensor must be capable of maintaining a precise distance from the track. To achieve good sensitivity this distance must be very small because field reduces with the square of distance (to a first order approximation). To create a practical current measurement probe, a very special type of miniaturised sensor was needed. The requirements included very small size with precision dimensions, dc sensing capability, wide ac bandwidth, and low noise. None of the existing sensor technologies used within field and current probes was suitable for this. The Fluxgate Magnetometer - updating an established principle The I-prober 520 uses the well established principle of a fluxgate magnetometer to measure field. Conventional fluxgate magnetometers are relatively large with bandwidths limited to a few khz. They are typically used for precision measurement of fields within geophysics and bio-electromagnetics. By contrast, the sensor within the I-prober 520 uses a patented miniature fluxgate magnetometer of submillimetre size incorporating a highly advanced core material. This enables it to use an excitation frequency of several tens of MHz resulting in a sensor with a bandwidth of dc to 5MHz combined with low noise and wide dynamic range. The illustration shows the main part of the magnetometer. The field sensing element is of sub-millimetre dimensions and is placed at the tip of the sensor. Making PCB current measurement a reality The concept of a positional current probe is not entirely new. However, previous attempts have been physically large and suitable only for measuring high currents at low bandwidth. The high excitation frequency miniature sensor within the I-prober 520 provides it with levels of positional accuracy, sensitivity, bandwidth and dynamic range that are superior to anything previously achieved by several orders of magnitude. Modern high-density electronic PCB layouts make current observation and measurement increasingly difficult In consequence, the Aim I-prober 520 is the first and only probe that can be used to measure currents from amps down to milliamps at frequencies from DC up to MHz, making practical measurement of PCB track currents a reality.

Aim I-prober 520 - a innovative and flexible measurement tool The I-prober 520 in use The magnitude of the signal from a positional current probe is critically related to its position relative to the conductor. The size of the conductor (e.g. the width of a PCB track) also has a significant effect. This means that the sensitivity of the I-prober has to be adjusted to match the track width when quantitative measurements are required. A calibrator within the control box enables sensitivity adjustment in conjunction with a calibration graph. The measurement result will also include other field effects present at the tip of the probe and not just that coming from the current through the conductor. This may include DC effects from adjacent magnetised components and from the earths magnetic field, plus AC effects from transformers and other field radiating sources. Current in adjacent tracks, or tracks on the opposite side of the PCB will also affect the measurement. There are solutions to these potential problems. The unwanted DC can be nulled out by observing the measurement without power to the circuit, whilst AC interference can be attenuated using bandwidth filters. The I-prober control box includes a wide range DC offset control and switchable filters. Nevertheless, the use of the I-prober 520 requires interpretation based upon a proper understanding of circuits and systems. It is a tool for the professional engineer. Closed-loop current measurement Whereas the primary purpose of the I-prober 520 is as a positional current probe, the are many circumstances where current measurements can be made in the conventional way by enclosing the conductor. To increase its overall usefulness, the I-prober 520 is supplied with a clip-on toroid assembly which converts it into a closed magnetic circuit probe for measuring current in a wire. The toroid is open until the probe is attached, allowing insertion of the wire without disconnection. The wide bandwidth, dynamic range and low noise of the probe are retained but higher accuracy, repeatability and unwanted field rejection are achieved. Minimal circuit disturbance With many high frequency switching circuits and high bandwidth signal paths, inserting even a short loop of wire into the track path can change the inductance sufficiently to alter the circuit performance. Unlike a conventional current probe, the I-prober 520 has an extremely low insertion impedance and negligible stray capacitance. This enables current observations and measurements to be made without disturbance to the circuit. Safe for higher voltage use The I-prober 520 is safety rated to 300V CAT 11 (600V CAT 1). This enables it to be used on circuits with direct connection to AC line at up to 300V rms, and on isolated circuits at voltages up to 600V rms. A finger guard is incorporated to maintain user safety at higher voltages. The probe can be used to measure high temperature PCB tracks and component leads up to 120 o C continuous or 150 o C short term. Measurement of electromagnetic field The very small size of the field sensor within the I-prober 520 gives it some unique capabilities when used to measure magnetic fields. The variation of field with position can be accurately determined enabling the precise source of fields to be located and their variation in space measured. A switch on the control box re-scales the output voltage to measure in Teslas or in amps per metre.

Technical Specifications GENERAL SPECIFICATIONS (All Modes) Output Signal Maximum Output: ± 10V. Oscilloscope Input: Suitable for an input impedance of 1MW in parallel with < 30pF. Trace Position: Wide range DC offset control within control box. Safety Max. Circuit Voltage 300V Cat II (on AC line circuits). 600V (on uncategorised secondary circuits inside equipment). Max. Tip Temperature 150ºC maximum allowable temperature at probe tip. Conformance Complies with EN61010-1 & EN61010-031 Bandwidth Control Switch Position Full 500kHz 2Hz Nominal Bandwidth: DC to 5MHz DC to 500kHz DC to 2Hz Risetime: <70ns 700ns 175ms Aberrations: <±5% <±1% <±1%. Noise (Typical)*: 6mA rms 3mA rms 1.5mA rms * This is the noise level for current measurement using the Toroid attachment. For PCB track measurement the equivalent noise will depend upon the track width and gain setting but will be similar to the Toroid measurement figure for a track width of 0.5mm. HF Performance (bandwidth switch at Full) Propagation Delay 60ns typical (to 10%). Bandwidth: DC to 5MHz (small signal) Slew Rate: 15A/µs (equivalent). Overload Indication Indicator Threshold: Indicator LED within control box will light if output voltage exceeds ± 10V or if large magnetic fields cause the system to saturate. Power Source Power Supply: 5.2V at up to 5 watts from AC line adaptor (supplied). Mechanical Probe Dimensions 155mm x 38mm x 28mm max; 2.8mm x 1.8mm at tip Cable Length 2m from probe tip to output BNC EMC Conformance Complies with EN61326 MAGNETIC FIELD MEASUREMENT (Mode = Field) Scaling Factor: 250µT (or 200A/m) per Volt. Accuracy and Linearity: ±3% Maximum Field: ±2 5mT (2000A/m). CURRENT MEASUREMENT USING TOROID (Mode = Wire) Scaling Factor: 1 Amp per Volt. Accuracy and Linearity: ±5% Current Range: ±10mA to ±10A (DC + peak) Max. Wire Diameter: 3.5mm (unbroken) or 6mm (end fed) The I-prober 520 is supplied complete with a fitted carrying case which accommodates all of the items including the power supply, instruction manual and calibration graph. The power supply has a universal voltage input (100V to 240V) and has interchangeable plugs for UK, Europe, USA and Australia. CURRENT MEASUREMENT IN PCB TRACKS (Mode = PCB Track) Scaling Factor: Adjustable to 1 Amp per Volt for track widths 0 2mm to 3.5mm (0 007 to 0 14 ) and 2 Amp per volt for track widths 3mm to 6.5mm (0 125 to 0 25 ) using Calibrator and compensation graph. Sensor Spacing: 0.7mm distance from sensor to PCB track set by probe design. Calibrator: Built-in calibrator within the control box providing an AC or DC calibration current through a 0.5mm track. Accuracy specifications apply for the temperature range 18 o C to 28 o C after one hour warm-up. Thurlby Thandar Instruments Ltd. operates a policy of continuous development and reserves the right to alter specifications without prior notice. Designed and built in Europe by: Thurlby Thandar Instruments Ltd. Glebe Road, Huntingdon, Cambridgeshire. PE29 7DR United Kingdom Tel: +44 (0)1480 412451 Fax: +44 (0)1480 450409 Email: info@aimtti.com Web: www.aimtti.com Brochure Part No. 82100-1440 Iss. 1A

Product Summary Laboratory Power Supplies Bench and system power supplies from 30 watts up to 1200 watts using linear, mixed-mode and PowerFlex regulation technologies. Company name and product brands Thurlby Thandar Instruments Ltd. (TTi) is one of Europe s leading manufacturers of test and measurement instruments. Products have been sold under two brand names: TTi and Aim. Waveform Generators Analog and digital (DDS) function generators, true arbitrary generators, arbitrary/function generators and pulse generators. In the future, however, the full product range will be branded Aim-TTi. This changeover will be gradual and many products will continue to carry the TTi or Aim brands for some time to come. Precision Measurement Instruments Benchtop DMMs, frequency counters, component measurement instruments (LCR), electronic dc loads, current probes. RF and EMC Test Equipment Spectrum analyzers, signal generators, frequency counters, power meters, emc measurement instruments. Web Addresses (URLs) The preferred URL for obtaining information concerning Aim-TTi products is: www.aimtti.com (international customers) Customers in the UK should use the URL: www.aimtti.co.uk Customers in the USA should use the URL: www.aimtti.us Note that previous URLs such as www.tti-test.com will continue to operate for the time being. Designed and built in Europe by: Thurlby Thandar Instruments Ltd. Glebe Road, Huntingdon, Cambridgeshire PE29 7DR England (United Kingdom) Tel: +44 (0)1480 412451 Fax: +44 (0)1480 450409 Email: info@aimtti.com Web: www.aimtti.com