TRAFO ELECTRIC P. LTD.

Similar documents
CAST RESIN DRY TRANSFORMER

Prolific Systems & Technologies Pvt. Ltd. CORE DETAILS. CENTRE Figure - II L-2 X Y Wt-2

Compact Substation or Prefabricated Substation Inside Totally Enclosed Weatherproof Enclosure COPYRIGHT REGISTERED

Transformer Winding Design. The Design and Performance of Circular Disc, Helical and Layer Windings for Power Transformer Applications

Transformer Technology Seminar What to consider at Design Reviews

COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3

Introduction. Centrado leading-edge transformer. Introduction

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

Arqrn{r$frqreffiffi. il il. ffirffiil,ilkffi*&ffiffixiil{tt. l{epal Hydro & Electric L,imited. cent. tso Regd No.: ISO 9001:2008

Power transformers for Network, Rectifiers, Furnace

Single & Three Phase Transformers SAMPLE. Learner Workbook. Version 1. Training and Education Support Industry Skills Unit Meadowbank

nical catalogue Tech

TIGHTENING TORQUE ON WOODEN CORE CLAMP (Nm) (STEEL FASTENER) 1 M M M M M

save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers

PURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS

(

INTERNATIONAL STANDARD

Liquid-Filled Transformers

A Review Comprehension: Guideline for Testing of HV, EHV and UHV Substation Equipment

TRANSFORMER TECHNOLOGY GPT

Federal Power Transformers LLC based in Abu Dhabi, UAE

K Factor Power Transformers

SHUNT REACTOR CORES Up to 765 kv MVAR

FASTENERS. Specialist in Hi-Tensile & Mild Steel

HOW TO SAFE GUARD THE TRANSFORMER..???

ON LOAD TAP CHANGERS RSV 5.3 TECHNICAL DATA

H C & Company.

PES & IAS NY Chapter And NY LMAG June 23 rd, 2015

Siemens Transformer Technology Seminar Insulation & Thermal Design

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

ON LOAD TAP CHANGERS RS 6.3 / RS 6 TECHNICAL DATA

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

Reactor and inductor are names used interchangeably for this circuit device.

APPENDIX 4 TYPICAL LAYOUT, VALUES AND CONSTANTS

REPORT OF PERFORMANCE TIC

TMC Transformers TMC

TRAFTOR WINDINGS CHANGING THE RULES TOROIDAL INDUCTORS & TRANSFORMERS SOLUTIONS PROVIDER AND MANUFACTURER

Shunt Reactors. Global Top Energy, Machinery & Plant Solution Provider

TECHNICAL SPECIFICATION FOR POWER TRANSFORMER

Electrical Design Process

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

On-Load Tap Changer Type M

TRANSFORMER OPERATIONAL. Principles, Selection & Troubleshooting

MODERN POWER TRANSFORMER PRACTICE BIBLIOGRAPHY

About us. Vision. To lead our field in innovation, quality and customer service.

EE059: Transformer Operation, Maintenance, Diagnosis & Testing

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers

INSTRUMENT TRANSFORMERS. Right Choice for Metering and Protection of Power. Electricfield

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

SHARDA Make Harmonics Filter

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

Power Transformers Basics

Arild Furnes,ATPA OGP/Petrobras workshop, Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems

and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads.

Discipline Electrical Testing Issue Date Certificate Number T-2837 Valid Until Last Amended on - Page 1 of 6 LOCATION 1

Basic Principles and Operation of Transformer

Underground System Design TADP 547

ON LOAD TAP CHANGERS RS 9.3 / RS 9 TECHNICAL DATA

Pomona, CA May 24 & 25, LTC Applications - Location, Series & Preventative Auto Transformers

CHAPTER 2 ELECTROMAGNETIC FORCE AND DEFORMATION

Efacec work every day to anticipate solutions for a sustainable world in the new energy era.

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

شركة الوقت للكهرباء والمقاوالت ذ.م.م.

Subject: Computer Aided Electrical drawing (CAED) Subject Code: 10EE65

Types CDG 11 and CDG 16 Inverse Time Overcurrent and Earth Fault Relay

VIRGINIA TRANSFORMER CORP. Drive & Rectifier. Transformersrs

Premium Quality Products Quick delivery within time Efficient After Sales Services

Subsidiary of ELSEWEDY ELECTRIC

Tougher than any challenge. Transformers for highcurrent. industrial applications. siemens.com/transformers

CHAPTER 3 SHORT CIRCUIT WITHSTAND CAPABILITY OF POWER TRANSFORMERS

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

AS/NZS :2013 (IEC , , MOD)

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

Design Comparison for Rectangular and Round Winding Distribution Transformer (1000kVA)

CONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS

AM SGB Sdn Bhd. Company Profile. Transformer First Class

Experimental Evaluation of Metal Composite Multi Bolt Radial Joint on Laminate Level, under uni Axial Tensile Loading

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

Reduction in Load (Copper) loss Due to Overhauling of Power Transformer or OLTC

TECHNICAL INFORMATION

POWER TRANSFORMER. Failure Analysis & Troubleshooting. H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

Western Mining Electric Association San Antonio TX Layer vs. Disk Windings Discussion NOVEMBER 15, SPX Transformer Solutions, Inc.

Ritz Instrument Transformers GmbH. Welcome

Processing guide for IMAGIN

UNIVERSITY OF TECHNOLOGY By: Fadhil A. Hasan ELECTRICAL MACHINES

Transformer Factory Testing

Training Fees 3,300$ per participant including Materials/Handouts, Tea/Coffee Refreshments & International Buffet Lunch.

This document is a preview generated by EVS

Kalpesh Synthetics Pvt. Ltd Supplier the Fabric for Industry

POWER TRANSFORMERS CATALOGUE

Benefits of SFRA - Case Studies

TECHNICAL SPECIFICATION

Specialists in HV and MV test and diagnostics. Testing in Substations

Induction heating of internal

SECTION TRANSFORMERS

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)

CONTENTS 2/ /7 8/9 10/11 12/13 14/15 16/17 18/19 20/21 22/23 24/25 26/27 28/29 30/31 32/ Contact Us 38

Transcription:

TRAFO ELECTRIC P. LTD.

About Us Trafo Electric P. Ltd. started manufacturing Power & Distribution Transformers in 1974. Originally known as J B Electricals, the unit s entire production was for BSES( Bombay Suburban Electric Supply, now Reliance Energy Ltd.) Trafo had entered into technical and marketing tie-up with M/s.Crompton Greaves In the year 1988. Trafo s transformers conform to the latest Indian Standard specification 2026, IEC-76 and BS-171. Trafo has been awarded ISO 9001: 2008 Quality Certificate. Trafo Electric P. Ltd. is a part of the 52 year old ALLSTATE Group.

Products & Services Trafo manufactures Power and Distribution Transformers with ratings from 25 KVA to 10000 KVA & up to 33 KV. Trafo also specializes in transformers for wind energy applications. Other transformers like Auto-Transformers, Lighting Transformers, Dry Type Transformers, Furnace Transformers, Wound Core Type Transformers are manufactured on demand. In addition to manufacturing transformer Trafo undertakes field work for the following services:- a) Inspection and testing of faulty / malfunctioning transformers at site to ascertain services necessary. b) Filtration of oil at site while the transformer is in running condition. c) Annual rate contract for repair / maintenance of transformers at site. Trafo s manufacturing and testing facilities are suitable for manufacture of transformers up to 10000 KVA, 33 KV.

Power & Distribution Transformers

Construction CORE: Core is built up from mitred low loss cold rolled, grain oriented steel laminations. Individual stampings are coated on both sides with an insulation material which is both oil and temperature resistant. The Core limbs are securely bound with heavy duty fibrous glass tapes and the yokes are firmly clamped between steel channels. All cores have mitred joints. Top & bottom clamps are secured to each other by means of tie rods which serve the dual purpose of securing the windings in place and of transferring the load from the bottom to the top clamps when the core and windings are lifted. This prevents tensile stresses being set up in the core legs which could adversely affect the iron losses.

Construction WINDINGS: Transformer windings are designed to meet three fundamental requirements such as mechanical, thermal and electrical. They are cylindrical in shape and are assembled concentrically. The low tension windings are of the helical type, single or multilayer, using flat copper strips, depending upon the size and current rating of the transformer. The high tension windings consist of paper covered round conductors. For higher KVA ratings continuous disc windings are used, for lower ratings cross-over type windings are used. The windings are rigidly supported by pre-compressed press board, dovetailed strips and spacers. Interlayer cooling ducts are provided to ensure that the temperature gradient between windings and oil are maintained and hence the hot spot temperature is minimized and a high life expectancy is achieved. Insulation between layers and turns is based upon the impulse test level of the voltage class of the winding as specified in IS 2026. Completed Core coil assemblies are dried and pressed to desired dimensions prior to impregnation with transformer oil under vacuum.

Standard Tests The following tests will be carried out on all Transformers. The numbers shown do not necessarily indicate the sequence in which the tests will be carried out. All tests will be in accordance with the. latest revision of IS 2026. 1. Measurement of resistances of all windings of each unit. 2. Ratio tests at all tap positions. 3. Polarity and Vector group tests at normal tap. 4. No load loss at rated voltage, rated frequency at normal tap. 5. Excitation current measurements at rated voltage, rated frequency at normal tap. 6. Impedance and load loss measurement at rated current, at normal tap of each unit. 7. Separate Source Voltage withstand test. 8. Induced over voltage withstand test. 9. Measurement of insulation resistance. 10. Dielectric capacity of the transformer oil.

Partial Client List Sr. No. Ratings (KVA) Transformer Voltage Ratio (KV) Name of the Customer Quantity (Nos) 1 63 11/.433 Hukeri Taluka Elec Soc Ltd., Belgaum 20 2 63 22/.433 BSNL (Telephone), Pune 2 3 100 22/.433 Cummmins India Ltd. Pune 1 4 200 33/.433 HEG Ltd., Bhopal 1 5 250 11/.433 Elegant Engineering, Madras 2 6 400 11/.416 Crompton Greaves Ltd. 1 7 500 11/.433 Thapar Dupont Limited, Goa. 1 8 500 11/.433 Dipak Vegetable Oil India Ltd, Gujarat 1 9 500 6.6/.433 Sunflag Iron & Steel Company 3 10 500 11/.433 T.I. DiamondChains, Madras 1

Partial Client List Sr. No. Ratings (KVA) Transformer Voltage Ratio (KV) Name of the Customer Quantity (Nos) 11 500 11/.433 Greaves Foseco, Jammu 1 12 500 11/.416 Didan Constructions, Shillong 1 13 500 11/.433 Lakme Ltd. 1 14 500 11/.433 Stated Vanaspati, Assam 1 15 500 11/.433 Indian Lead Ltd. Thane 1 16 500 11/.433 Baroda Dist. Co.op Milk Ltd, Baroda 1 17 500 11/.433 National Telecom of India Ltd., Nasik 1 18 630 11/.433 Samir Electricals, Pune 2 19 630 11/.433 Goeffrey Manner Co Ltd., Nasik 1 20 750 11/.433 Alfa Laval India Ltd., Pune 2

Partial Client List Sr. No. Ratings (KVA) Transformer Voltage Ratio (KV) Name of the Customer Quantity (Nos) 21 750 11/.433 Hyderabad Ind Ltd 1 22 750 11/.433 Delhi University 1 23 750 11/.433 Vijay Traders, Delhi 2 24 750 6.6/.433 Vindhya Builders, Calcutta 2 25 750 33/.415 Synthetics & Chemicals, U.P. 1 26 750 33/.433 Shogun Organics Limited, Pune 1 27 950 22/.69 -.400 NEG Micon (I) Pvt. Ltd., Chennai 27 28 1000 11/.433 Rawal Electricals, Delhi 3 29 1000 6.6/.433 Ballarpur Industries Limited 1 30 1000 22/.440 Zenith Tin Works Ltd 1

Partial Client List Sr. No. Ratings (KVA) Transformer Voltage Ratio (KV) Name of the Customer Quantity (Nos) 31 1000 11/.433 Ring Gears Limited, Nasik 3 32 1000 11/.433 Shrikrishna Petro Yarn Ltd, Silvassa 1 33 1000 6.6/.433 Continental Construction Co., Bombay 1 34 1000 11/.433 Kirti Dal Mills Ltd., Latur 1 35 1500 11/.433 Ugar Sugars Ltd., Hubli 1 36 1500 11/.433 Kirti Foods Ltd., Latur 1 37 1250 33/.69/.400 NEG Micon (I) Pvt. Ltd., Chennai 10 38 2500 33/.433 Kirti Oil Mill Ltd., Latur 1 39 3150 33/6.6(OLTC) Mahati Electrics, Pune 2

Certificates

Company Overview FACTORY Trafo s manufacturing facilities at MIDC, Chinchwad near Pune, spread across 30,000 sq.ft., is equipped with all modern manufacturing machinery s and testing instruments required for production of transformers under IS-2026/IEC-76. TRANSFORMERS Trafo s Transformers under-production at their factory at MIDC

Company Overview AN INSIDE VIEW An inside view of Trafo s manufacturing facilities at MIDC, Chinchwad near Pune, which is equipped with all modern manufacturing machineries and testing instruments. TESTING ROOM Trafo s Transformers gets tested in our fully equipped Testing Room, under different quality standards before delivering them to our clients.

Company Overview TRANSFORMERS UNDER-PRODUCTION Trafo s Transformers under-production at MIDC factory. TRANSFORMER INSTALLED One of Trafo s 315 KVA/ 11 KV Transformer has got successfully installed at our client's location

Factory

Corporate Office

Contact Us 901, Maker Chambers V, Nariman Point, Mumbai - 400 021, India. Telephone Nos.: 91-22- 6628 80 00-99 Fax : 91-22 - 2204 4944 Email: info@trafo.in or info@allstate.in Web Url : http://www.trafo.in Plot No. 34, D 11 Block, MIDC, Telco Road, Chinchwad, Pune - 411 019 Tel: (9520) 2747 0646, 2447 1542 Telefax: (9520) 2747 1552