AC axial compact fan

Similar documents
AC axial compact fan

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

AC axial fan. sickled blades (S series)

AC centrifugal fan. forward curved, dual inlet with housing (flange)

AC diagonal compact fan

AC axial compact fan

AC centrifugal fan - RadiCal

AC centrifugal fan. forward curved, single inlet with housing (flange)

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

AC axial compact fan

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

AC centrifugal fan. forward curved, single inlet with housing (flange)

onlinecomponents.com

AC centrifugal fan. backward curved

AC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

AC centrifugal fan. forward curved, dual inlet with housing (without flange)

EC centrifugal fan - RadiCal

EC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan. forward curved, dual inlet with housing (flange)

AC centrifugal fan. R2E180-AS backward curved, single inlet. Nominal data

EC centrifugal fan. forward curved, single inlet with housing (flange)

EC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan. forward curved, dual inlet with housing (large flange)

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

EC centrifugal fan. forward-curved, dual-intake with housing (flange)

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G3G250-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G3G200-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G3G200-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan. backward curved, single inlet

EC centrifugal fan - RadiCal

EC centrifugal fan. backward curved, single inlet

EC centrifugal fan. backward curved, single inlet

EC centrifugal fan. R3G175-AF25-02 backward curved, single inlet. Nominal data

Tangential Fans - Basic principles. Expertise, performance, innovation

DC axial compact fan

EC/AC axial fans - HyBlade Ø

Soğutmada büyük beden modası

Product Data Sheet RER190-39/14/2TDMO

Product Data Sheet RER220-43/18/2TDMO

Product Data Sheet RER225-63/18/2TDO- 406

Automotive BL-DC Fans for Commercial Vehicles. Edition

Product Data Sheet 3252J/2H3PU

Product Data Sheet RG160-28/18N/2TDPU-331

Product Data Sheet 6424/2HP-210

Tangential blowers with multiple housings. Optimized air flow steady distribution.

Product Data Sheet 3254 J/2H3P

Product Data Sheet 8452/2HHP. The engineer's choice

Cross Flow Fans. Additional Information. Cooling Fans. Introduction E-85 MF Series E-88 MFD Series E-92

Product Data Sheet 8214 J/2H4P. The engineer's choice

Specification For Approval

Product Data Sheet 6314/2TDHP. The engineer's choice

Product Data Sheet 8452/2 GHHP

SPECIFICATION FOR APPROVAL

Lowara. Centrifugal pumps with open impeller and flanged connections. SHO Series MARKET SECTORS CIVIL, INDUSTRIAL.

System protection by Vibration monitoring

Split case double suction centrifugal pump. Technical data Serie: DPAS C

ILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector

Product Data Sheet 622/2HHP-021

ACS600, ACS800. Installation Guide

Lexium integrated drives

Product Data Sheet DV4112/2NP-201

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

Product Data Sheet 8214 J/2H4P

Online data sheet MAX48N-31V10K12500 MAX48 LINEAR ENCODERS

Specification For Approval

Han High Temp. Description. Design overview. Han High Temp connectors remain robust and reliable for their entire lifespan!

Specification For Approval

Specification For Approval

C B. Models. Models 2MOPP

Explosion proof rotary actuator - On/Off or programmable regulating actuator

SPECIFICATION FOR APPROVAL

LSA R & LSA H 49.1 Low Voltage Alternators - 4 pole

IP65 Splash and Dust Proof Stepping Motors

Electrical height adjustment. ... easy & reliable. Multilift II telescope Multilift II. Synchron

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

14 mm sq inch sq.

CUSTOMER: ARCERA EU MODEL NO: 9225 (CeraDyna Fan) PART NO: FD1290-AP181E3AL DATE: CUSTOMER APPROVAL. Taiwan. Page 1 of 12 REV.

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

UPA 150C. 50 Hz. Applications. Submersible Borehole Pumps for Well Diameters of 150 mm (6 inches) Operating Data. Design. Designation (Example)

VFB40 Frequency inverters 004 to 016 (B1) VFX40 Frequency inverters 018 to 037 (S2)

MINI-PS AC/24DC/1.3

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

SPECIFICATION FOR APPROVAL

PARTNER ALTERNATORS LSA 40-4 Pole

847H. Description. Features. Specifications

LED Driver Linear / area fixed output

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Primary switch mode power supplies Product group picture

SPECIFICATION FOR APPROVAL

Transcription:

WE5-HL6- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HR 59 General partner Elektrobau Mulfingen GmbH Headquarters Mulfingen County court Stuttgart HRB 59 Nominal data Type Motor WE5-HL6- ME68-CF Phase ~ ~ Nominal voltage VC Frequency Hz 5 6 Type of data definition fa fa Valid for approval / standard CE CE Speed min - 55 7 Power input W 7 8 Current draw.56.79 Motor capacitor µf Capacitor voltage VDB Capacitor standard P (CE) P (CE) Max. back pressure Pa Min. ambient temperature C -5-5 Max. ambient temperature C 6 5 Starting current.88.87 ml = Max. load me = Max. efficiency fa = Running at free air cs = Customer specs cu = Customer unit Subject to alterations Data according to ErP directive Installation category Efficiency category Static Variable speed drive No Specific ratio *. * Specific ratio = + p fs / Pa ctual Request Request 5 Overall efficiency η es % 6.5. 8. Efficiency grade N 8. 6 Power input P e kw. ir flow q v m³/h 5 Pressure increase p fs Pa 5 Speed n min - 65 Data definition with optimum efficiency. LU-65 The ErP data is determined using a motor-impeller combination in a standardised measurement configuration. Item no. 76-5-998 Revision 8555 Release -5-8 Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com

WE5-HL6- Technical features Mass Size Surface of rotor Material of blades Material of wall ring Number of blades 7 Direction of air flow Direction of rotation.8 kg 5 mm Coated in black Sheet steel, coated in black Die-cast aluminium "V" Type of protection IP Insulation class Humidity class Max. permissible ambient motor temp. (transp./ storage) Min. permissible ambient motor temp. (transp./storage) Mounting position Condensate discharge holes Operation mode Motor bearing Touch current acc. IEC 699 (measuring network Fig., TN system) Electrical leads Motor protection Cable exit Protection class Product conforming to standard Counter-clockwise, seen on rotor "F" F + 8 C - C ny None S Ball bearing <.75 m Via terminal strips, integrated capacitor connected via terminal strips Thermal overload protector (TOP) wired internally Variable I (if protective earth is connected by customer) EN 65-; CE pproval CCC; CS C. Nr.77; EC; UL Item no. 76-5-998 Revision 8555 Release -5-8 Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com

WE5-HL6- Product drawing Direction of air flow "V" Connection screen U blue Z brown U black PE green/yellow Item no. 76-5-998 Revision 8555 Release -5-8 Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com

WE5-HL6- Charts: ir flow 5 Hz Druck p f s[pa]für Rho=,kg/m^ qv[cfm] 6 8..,9,85 9 8 7 6 5,8,75,7,65,6,55,5,5, pfs_e[in HO] ir performance measured as per ISO 58 Installation category. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: Lw measured as per ISO 7 / Lp measured with m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. 9 8 7 6,5,,5 5,,5, 6 8.. qv[m^/h]..6.8.,5. Measured values U V f Hz 5 5 5 5 n min - 55 85 85 P e W 7 6 6 I.56.59.6.6 qv m /h 865 69 5 75 p fs Pa 7 U = Supply voltage f = Frequency n = Speed P e = Power input I = Current draw qv = ir flow p fs = Pressure increase Item no. 76-5-998 Revision 8555 Release -5-8 Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com

WE5-HL6- Charts: ir flow 6 Hz Druck p f s[pa]für Rho=,kg/m^ qv[cfm] 6 8..,8 9,75 8 7 6 5 9,7,65,6,55,5,5,,5 pfs_e[in HO] ir performance measured as per ISO 58 Installation category. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: Lw measured as per ISO 7 / Lp measured with m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. 8 7, 6,5 5,,5,,5 6 8.. qv[m^/h]..6.8.. Measured values U V f Hz 6 6 6 6 n min - 7 575 85 7 P e W 8 86 89 9 I.79.8.8.8 qv m /h 97 755 56 5 p fs Pa 7 U = Supply voltage f = Frequency n = Speed P e = Power input I = Current draw qv = ir flow p fs = Pressure increase Item no. 76-5-998 Revision 8555 Release -5-8 Page 5 / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com