Partial Discharge Detector and Radio Interference Voltage Testing

Similar documents
Spectrum Analyzer, Partial Discharge Detector, and RIV Meter

Three-Phase Transformer Test Systems

SIGNAL RECOVERY. Model 7265 DSP Lock-in Amplifier

The University of New South Wales. School of Electrical Engineering and Telecommunications. High Voltage Systems ELEC9712. Appendix Partial Discharge

AC Resonant Test Systems Tank Type Up to 150 kv

AC Resonant Test Systems Tank Type Up to 500 kv

Diagnosis Monitoring Quality Control Research and Development

AC Dielectric Test Systems

PD Power Diagnostix Systems GmbH

IRIS POWER TGA-B. Periodic Online Partial Discharge Monitoring Instrument for Turbine Generators and Motors

Advanced Test Equipment Rentals ATEC (2832)

MPD 500. Partial Discharge Measuring System for Routine Test Applications

Portable Multi-Channel Recorder Model DAS240-BAT

Modular Partial Discharge (PD) & Radio Interference Voltage (RIV) Detector

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

TD 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

PD Solutions. On-Line PD Measurement Devices

Arbitrary/Function Waveform Generators 4075B Series

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

Current sensor by IZM

IRIS POWER PDTracII. Continuous On-line Partial Discharge Monitoring for Motors, Generators, Dry Type Transformers, and Air-Insulated Switchgear.

DECLARATION OF CONFORMITY

Model 3102D 0-2 kv H.V. Power Supply

IRIS POWER PDTracII. Continuous On-line Partial Discharge Monitoring for Motors, Generators, Dry Type Transformers, and Air-Insulated Switchgear.

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

DOBLE F6150e TECHNICAL SPECIFICATIONS

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

U1571A Ni-MH Battery Pack for U1600A Handheld Oscilloscopes

TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR EXTENDED SPECIFICATIONS

MODEL 9050 EXTENDED SPECIFICATIONS. 50ppm TRANSPORTABLE CALIBRATOR

TLP/VF-TLP/HMM Test System TLP-3010C/3011C Advanced TLP/HMM/HBM Solutions

Fluke 5820A Oscilloscope Calibrator Specifications

Programmable AC Power Source Model 9801

Complimentary Reference Material

Specification for Conducted Emission Test

DOBLE F6150SV TECHNICAL SPECIFICATIONS

DSA700 Series Spectrum Analyzer

U1604A Handheld Oscilloscopes, 40 MHz

TD-106. HAEFELY HIPOTRONICS Technical Document. Partial Discharge Pulse Shape Analysis to Discriminate Near and Far End Failures for Cable Location

DATA SHEET A Multimeter 5.5 Digit Dual Display, Benchtop DMM

PHG 70 TD PD / PHG 80 TD PD

R&S ZNB Vector Network Analyzer Specifications

Model 310H Fast 800V Pulse Generator

Spectrum Analyzers R3132/3132N/3162 R3132/3132N/3162. Low cost, high performance. General-Purpose Spectrum Analyzer Adaptable to Various Applications

Partial Discharge Measurement and Monitoring on High Voltage XLPE Cables

Arbitrary/Function Generator AFG1000 Series Datasheet

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

R&S ZNC Vector Network Analyzer Specifications

EFFECT OF INTEGRATION ERROR ON PARTIAL DISCHARGE MEASUREMENTS ON CAST RESIN TRANSFORMERS. C. Ceretta, R. Gobbo, G. Pesavento

5500A. Multi-Product Calibrator. Extended Specifications 2005

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

Model 6517B Electrometer / High Resistance Meter Specifications

Vector Network Analyzers ZVB

D D X. Digital Partial Discharge Detector

Tektronix: Products > AWG 2040 Arbitrary Waveform Generator

MODEL 9041 EXTENDED SPECIFICATIONS. 25ppm TRANSPORTABLE CALIBRATOR

Exposure Level Tester ELT-400

MPD 600. High-end measurement and analysis system for partial discharges

Technical Specification

Current sensor demonstrator by IZM

HZJF-9007 Fully Functional Partial Discharge Inspector USER MANUAL. Huazheng Electric Manufacturing(Baoding) Co.,Ltd

MPD 600. High-end partial discharge measurement and analysis system

DC Electronic Loads 8500 Series

8558A 8 1/2 Digit Multimeter

Bipolar Output Working Standard

Output Impedance. Duty Cycle Range. Buffer Size Resolution. PROTECTION Input Over Voltage. Output Short Circuit. TRIGGERING Sources.

Moving Test - MT3000

HZ530 Near-Field Probe Set

R&S SMB100N SIGNAL GENERATOR

BENCH METER Model>9803. Wavecom Instruments

HAMEG Modular System Series 8000

Advanced Test Equipment Rentals ATEC (2832)

N432A Thermistor Power Meter DATA SHEET

Power Meter NRVS. Power, level and voltage measurements from DC to 40 GHz

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

The Meter Structure The Figure 2-1 shows the Meter structure.

Chapter 5 Specifications

Analog Digital Multimeter with Insulation Resistance Measurement

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

APPA 300 Series. The Most User-Friendly High Performance Multimeter

True RMS Bench Multimeter 5492B

ARCO 400. Technical Data

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

PM 6669 High-Precision Frequency Counter Specifications

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

GAMMA 10 DIGITAL MULTIMETER

M302RM OPERATING MANUAL

True RMS Bench Multimeter 5492B

WaveStation Function/Arbitrary Waveform Generators

WaveStation Function/Arbitrary Waveform Generators

R&S ZVT Vector Network Analyzer Specifications

1 INTRODUCTION ORDER CODE / INFORMATION

OCS 500N6F SERIES SIMULATOR FOR FAST AND SLOW DAMPED OSCILLATORY WAVES AND RINGWAVE

Voltage Sensors URV5-Z

Customer: Standard type Page 1 of 7 Description Fluxgate current sensor with toroidal core PCB mounting

2-channel models. 4-channel models

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

Current clamps for AC current

Transcription:

Partial Discharge Detector and adio Interference Voltage Testing Compact Design Easy to Use Precise esults Stand-alone or computer operated An economical PD testing solution Testing Applications Condition evaluation of insulation systems Quality assurance testing in manufacturing plants Partial Discharge Measuring Partial discharge (PD) measurements are a proven method for effective, non-destructive evaluation of electrical insulation. The PD2U provides a simple pushbutton interface with an LCD display. Display modes include a simple PD charge meter with adjustable needle sensitivity, monochrome phase-resolved PD patterns for characterization of defects, and a scope-like display showing phase-summed charge pulses superimposed with the applied voltage wave. High voltage is displayed showing the waveform and calculates Û, Û/ 2, Urms. Although the PD2U is a stand-alone unit, it can be connected to a computer to capture screenshots or to implement remote control of the unit. A wide range of accessories are offered adapting the PD2U to specific testing applications and noise conditions. Measured results are in compliance with IEC 60270. outine testing in a variety of applications Model PD2U CABLE GIS CICUIT TANSFOME MOTO GENEATO INSULATION ECLOSE POTECTIVE POTABLE SWITCHGEA BEAKE MATEIALS EQUIPMENT Specifications are subject to change without notice. Brochure No. 90503 G

features The PD2U offers convenient on-site testing of electrical equipment. The basic unit can be equipped with various options to suit special measurement requirements. This unit can be used with a full range of preamplifiers covering the IEC60270 standard and ultrasonic frequencies up to the UHF range (20 khz-2 GHz). Cable PD location (Option). Equipped with a DSO board, the PD2U can be used to locate partial discharge defects in power cable. Using time domain reflectometry, in which the PD and its echoes travel the length of the cable under test, the PD2U provides the proportional distance of the PD fault along the cable. The additional DSO board samples the PD signal at 100M sample rate. MUX4 (Option). 4-channel multiplexer for testing three-phase equipment such as power transformers. For each channel the unit maintains an individual set-up and calibration. Coupling Unit Coupling Capacitor + Quadrupole Specifications Test Object Bushing Cable Switchgear Capacitor GIS Transformer Motor Generator Other Preamplifier PA1 PD Detector PD2U Database Software Evaluation Data Files MS Excel Other Acquisition Unit Input 100-240 VAC, 50/60 Hz Power 25 VA Temperature ange 10 C 45 C Dimensions 9 ³/8 (236 mm) W 11½ (295 mm) D 5¼ (133 mm) H Weight 7 lbs. (3 kgs) eference Voltage Input (BNC) Input Impedance Input Voltage Frequency 1 MΩ / 200 pf Max. 120 V (rms) 20-510 Hz Description Desktop Acquisition and Display Unit (Single Channel) Voltage measurement Backlit LCD 240 x 128 dots Scope and meter display Auto-range function Automatic storage of current settings Internal (line 50/60 Hz) and external synchronization (15-510 Hz) Universal serial interface (USB, up to 921 kb) Partial Discharge Signals Coupling AC Input Impedance 50 Ω (without PA) Low Frequency Cutoff 40, 80, or 100 khz High Frequency Cutoff 250, 600, or 800 khz ENVIONMENTAL CONDITIONS 10-40 C, indoor/outdoor in fair weather Humidity <95% non-condensing Altitude <3300 ft (1000 meters) www.phenixtech.com

Description PA1 Preamplifiers The PA1 is the standard preamplifier for measurements in the low frequency range according to standards such as IEC60270. Frequency ange: 40-800 khz Input Impedance: 10 kω/50 pf Input Sensitivity: <200 µv oll-off: 40 db/dec Bipolar Preamplifiers serve to condition, filter, and amplify the partial discharge signal to be measured. Because the frequency range in which PD signals are measured is strongly dependent on the preamplifier used, proper selection of a preamplifier is an important part of noise mitigation and can have a strong effect on the appearance of the partial discharge pattern itself. All external signal conditioning modules and preamplifiers are remote supplied and remote controlled through a simple coaxial signal cable (G58). This technique allows placement of these units close to the sensor or signal source. Furthermore, as these modules act as an impedance converter and line driver, the weak signal source, such as voltage divider or coupling impedance, is not loaded by the cable capacitance or impedance. This technique also provides enhanced over-voltage protection. All preamplifiers can drive a 50 Ω cable up to 50 m long. Quadrupoles When a quadrupole and a coupling capacitor are used together as the coupling device, high voltage is applied both to a test object and to the coupling capacitor in parallel with the test object. A quadrupole (sometimes called a measuring impedance) can then be placed in series with either the coupling capacitor or in series with the test object. Some quadrupoles also output a low-voltage copy of the applied high-voltage wave for synchronizing with the PD detector. The CIL quadrupoles consist of an inductor in parallel with a damping resistor. The inductor and resistor are calculated to form, together with a high-voltage coupling capacitor, a second order high pass filter. Therefore, matching the range of the CIL with the size of the coupling capacitor with which it will be used is important. The CIL/V quadrupoles are similar to the CIL quadrupoles but also contain a capacitor acting as a voltage divider together with the high voltage coupling capacitor. This provides a low-voltage copy of the applied highvoltage wave that can be used through a HST to synchronize the PD detector and monitor the quality of the applied high-voltage wave. Optionally, the quadrupoles with built-in divider capacitor for voltage measurement can be supplied with a rotary switch to select the divider capacitor. When connected to the measurement tap of transformer bushings, the selectable capacitors expand the applicable voltage range. Model CIL4M/V1µ0 CIL4M/V2µ0 CIL4M/V3µ5 CIL4M/V4µ0 ange Designed for up to 100 kv, 1 nf Capacitor ange, 400 ma max Designed for up to 200 kv, 1 nf Capacitor ange, 400 ma max Designed for up to 350 kv, 1 nf Capacitor ange, 400 ma max Designed for up to 400 kv, 1 nf Capacitor ange, 400 ma max *Other quadrupoles are available +1.301.746.8118

Calibrators A calibration charge injector is suitable for use in calibrating partial discharge measurements. The appropriate choice of a calibration instrument depends on the range of typical charge values of the PDs being measured. Calibrators can also be used for time domain reflectometry in cables to determine cable length and location of joints. The calibrator is switched on with the pushbutton On/Off. Both amplitude (ange) and polarity (Pos/Neg) of the single charge pulse per cycle are displayed and can be adjusted by pressing the two buttons. Each calibrator is also available supplying two pulses per cycle, as well as with double impulse output with adjustable interval. The instrument automatically synchronizes to line frequency by a photo diode. In case of insufficient pick-up of power frequency light, the calibrator automatically selects the internal quartz oscillator. Calibration impulse generators are unique in that the charge pulse is generated by injecting a variable voltage step (correlated to an internal reference) via a fixed capacitor. This injection capacitor is relatively small, as the step voltage amounts up to 120 V for full range output. Therefore, calibrators offer excellent impulse properties. Further, calculation of the correction factor is usually not necessary (C I <<C S ). Model ange use CAL1A 1,2,5,10,20,50,100 pc Standard lab use CAL1B 100,200,500 pc, High output, mainly 1,2,5,10 nc suitable for rotating machine testing and recommended for transformer testing CAL1C 1,2,5,10,20,50,100 pc Can be used with HV at 100 pf with external Injection Capacitor high voltage capacitor CAL1D 10,20,50,100,200,500,1000 pc Transformer Testing Additional Specs: 50 Hz or 60 Hz light synchronization, IEC60270 compliant, 2 pulses/cycle option, BNC connection. Calibrators include a DKD calibration certificate to ensure the traceability to international standards. Connecting Cables A full set of high quality G58 cables with BNC connectors is supplied. 2 x 20 m Quadrupole Connection Set Power Lead www.phenixtech.com

Options Triggered Noise Cancellation GATE Software controlled gating from a signal connected to an auxiliary input. Gating threshold may be set manually or automatically. Includes the built-in logarithmic preamplifier PA6. Current Transformer Standard Control Software Software to remote control the PD2U and for data acquisition 3-D Phase esolved PD Pattern Acquisition ActiveX Driver License Supports fast USB communication Enhanced Cable Location Software Software to remotely control the PD2U with the PD fault location option. Offers automatic scanning, viewing, editing, re-playing, and printing of partial discharge signals. Zoom and cursor functions offer precise location results. Includes the standard control software. When a current transformer is used instead of a quadrupole, the current transformer can be placed around a coupling capacitor terminal or around a part of the test object itself. A current transformer has the advantage of providing galvanic isolation between the PD detector and the high voltage circuit. Current transformers are offered as separate modules or integrated with a coupling capacitor into a single unit. ack Mounting Kit 19, 3U standard rack mount for PD2U acquisition unit DSO, Cable PD Fault Location Digital Signal Processor Built-in digital scope (100M sample) DSO (TD) Display MUX4: 4 Channel Measurement Upgrade A built in multiplexer with four inputs for PD measurement and four inputs for voltage measurement. Firmware offers four individual setups and calibration factors. Additional line of pushbuttons for direct channel selection. Includes the following components: Voltage Measurement [3] additional sets of Connecting Leads [3] additional Quadrupoles [3] additional Pre-Amplifiers +1.301.746.8118

ADIO INTEFEENCE VOLTAGE (IV) TESTING MODEL IV-3 COMPONENTS Desktop Acquisition and Display Unit (Three Channel) Backlit LCD Display Meter display 0-2500 µv (@ k=1) Auto-range function Automatic storage of current settings IV bandwidth 9kHz (ANSI C63.3-1996) eference channel for IV calibration Center Frequency 100 khz 2MHz (10 khz steps) Serial Interface (USB, 57.6 Bit/s fixed) The IV meter is an instrument for the measurement of adio Influence Voltage according to NEMA 107-1987 and other relevant standards (ANSI 63-2-1996, VDE 876, DIN EN 55016-1-1). The instrument has a bandwidth of 9 khz and a tunable center frequency of 10 khz-10 MHz. Technically, the IV meter is a selective µv-meter. However, the meter reading is weighted according to the CISPE weighing curve, whereas the repetition rate has a strong impact on the reading. The IV meter is an ideal instrument to replace outdated IV measurement instruments in transformer testing labs. Some routine PD measurements are still done according to IEEE standards requiring the measurement of IV. The IV value is given in µv (interference voltage). A narrow band filter performs a quasi-integration of the PD pulses with a quasi-peak detection at the center frequency. This center frequency can be adjusted between 10 khz and10 MHz. Two factors determine the IV in µv: the transferred charge and the repetitive rate of the PD impulse (number of PD pulses per second). Because of this proceeding, a direct translation of the measured IV values (µv) into values of apparent charge in pc is not possible. Historically, the IV technique is based on measurement receivers to estimate the disturbance of communication lines. Thus, properties of those instruments then available became part of the NEMA standards. However, both the 9 khz bandwidth and the CISPE weighing curve put emphasis on some partial discharge activity while they tend hiding others. The calibration of the IV measurement is done using an IV calibrator, injecting a sine wave of typically 100 µv into the bushing. The multiplexer of the IV meter is used to conveniently determine the correction factor according to NEMA 107-1987 and other standards. Here, the unit compares the voltage injected (loaded by the bushing s impedance), with the voltage detected at the bushing tap to automatically determine the k-factor. This correction factor is then stored independently for each channel during calibration. The standard calibrator for IV calibration, CAL3A, offers a selectable frequency range of 600-1350 khz in steps of 50 khz. The output voltage covers 10 µv to 10 mv in 1-2-5 steps. Calibrator Model CAL3A Selectable level 10 µv (20dBµV) to 10 mv (80 dbµv) Available in steps of 1-2-5 Error rate of +/- 5% Adjustable Frequency between 600kHz & 1350kHz (50kHz steps) Comes with ISO17025 Calibration Certificate traceable to DKD 3 Channel Multiplexer Model MUX3 Built in multiplexer with three inputs for IV measurement and three inputs for voltage measurement Firmware offers individual setups and calibration factors Second line of push buttons for direct channel selection Note: Multiple channel IV systems require a coupling capacitor per channel. For a Coupling Capacitor to operate in the range of 50 to 500 Hz, it requires the next higher rated voltage capacitor. www.phenixtech.com

Partial Discharge Free Coupling Capacitors Model CC25-1, 25 kv 1 nf, 50-400 Hz with base Model CC50-1, 50 kv 1 nf, 50-400 Hz with base Model CC100-1, 100 kv 1 nf, 50-400 Hz with base Model CC200-1, 200 kv 1 nf, 50-60 Hz Model CC300-1, 300 kv, 1 nf, 50-60 Hz Model CC400-1, 400 kv, 1 nf, 50-60 Hz Model CC500-1, 500 kv, 1 nf, 50-60 Hz Model CC600-1, 600 kv, 1 nf, 50-60 Hz Partial Discharge Free Injection Capacitors Model IC100-0.1, 100 kv, 100 pf, 50-400 Hz with base Model IC200-0.1, 200 kv, 100 pf, 50-60 Hz Model IC300-0.1, 300 kv, 100 pf, 50-60 Hz Model IC400-0.1, 400 kv, 100 pf, 50-60 Hz Model IC500-0.1, 500 kv, 100 pf, 50-60 Hz NOTE: Injection capacitors require CAL1C PD Calibrator Multiple channel PD systems require multiple capacitors 400 Hz operation available only up to 200 kv on both Coupling and Injection Capacitors Model CC300-1 Model CC100-1 Model IC100-0.1 +1.301.746.8118

PHENIX Technologies is committed to providing leadership, innovation, technology, quality, and service in all areas of our business. Our 80,000 square-foot headquarters is a modern manufacturing facility. All aspects of electrical, mechanical, and software design and production are performed in this facility and controlled by an ISO9001 certified quality program. Our engineers offer a unique blend of theoretical knowledge and practical experience. Our Service and Calibration Department assists customers during and after installation to insure years of trouble free service. We carry our commitment into the future as we proudly continue to provide the best in high voltage, high current, high power test systems and components. High Voltage High Current High Power Test Systems and Components C E ISO 9001 TIFIED PHENIX TECHNOLOGIES World Headquarters Phenix Technologies, Inc. 75 Speicher Drive Accident, MD 21520 USA Ph: +1.301.746.8118 Fx: +1.301.895.5570 Info@phenixtech.com Branch Offices Phenix Systems AG iehenstrasse 62A, 4058 Basel, Switzerland Ph: +41.61.383.2770 Fx: +41.61.383.2771 Info@phenixsystems.com Phenix Asia Zhong Cheng d, Sec 1, No 177, 2F, Taipei 11148 Taiwan Ph: +886.2.2835.9738 Fx: +886.2.2835.9879 Info@phenixasia.com www.phenixtech.com Copyright Phenix Technologies, Inc. 1/2015